Programmable Temperature Controller (Digital Controller)

Similar documents
Infrared port USB. Control Output 2. (built-in) SSR outputs

E5CN/E5CN-U (48 x 48 mm)

E5AN/E5EN (96 x 96 mm and 48 x 96 mm)

E5CN/E5CN-U (48 x 48 mm)

E5CN/E5CN-U (48 x 48 mm)

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

E5AN-H/E5EN-H. Advanced Digital Temperature Controller

A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function.

Ultrasonic Reflective Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

E5CN/E5CN-U (48 x 48 mm)

onlinecomponents.com

Model Number Structure

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Ultrasonic Reflective Sensor

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Series Temperature Controller Instruction Sheet

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Bulletin 900-TC. Bulletin 900 TC Temperature/Process Controllers. Certifications. Bulletin 900-TC8 Controller Models

Digital Heater Element Burnout Detector K8AC-H

Temperature Controllers

Temperature Controller

02/11/2015

TEMPERATURE CONTROLLER

Series Digital Controller Instruction Sheet

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Temperature Controllers E5CSV

02/11/2015

Ultrasonic Proximity Sensor

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

INSTRUCTION MANUAL Micro-computer based digital indicating controller

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Instruction manual Micro-computer based digital indicating controller

Nov 08 PRODUCT SPECIFICATION SHEET

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Scale 0: 10 k Scale 50: 10 k (see note 2)

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

SHIMADEN DIGITAL INDICATORS

F4 Process Controller Installation and Operation Guide

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Instruction manual Temperature Controller KT7

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Digital Temperature Controllers

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

DIGITAL INDICATOR JIR-301-M

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

RS485 MODBUS Module 8AI

GCS-300 No.GCS31E

E5CN Temperature Controller User s Manual

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

Digital Temperature Controller E5AZ

E5CN-FR Limit Controller USER S MANUAL

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

UDC 700 Universal Digital Controllers and Indicator Specifications

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL

DIGITAL INDICATOR DI25

General Specifications

UDC100 Universal Digital Controller Specifications

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

Series Temperature Controller Instruction Sheet

7EF/7HF/7EC/7ES Temperature Controllers

I/A Series 716C 1/16 DIN Temperature Controller

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

TEMPERATURE CONTROL MODULE MODEL R3-TC2

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

MICROJET RECORDER (180mm)

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

CN4800 Series CONTROLLER

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Transcription:

Programmable Temperature Controller (Digital Controller) E5AN-HT/ (96 x 96 mm and 48 x 96 mm) _ E Programmable Controllers Join the Series! Program up to 56 segments and take advantage of the high cost performance of the new LCD that improves both the field of view and contrast. Set up to 8 programmed patterns with up to 3 segments (steps) each. High-resolution display with 5 digits/. C display. High-speed sampling cycle of 6 ms. High Accuracy Thermocouple/Pt : ±.% of PV Analog : ±.% FS Universal s on all models (thermocouple, PT, or analog ) to handle various sensors with one Controller. s also available with Remote. A PV/SV-status display function can be set to automatically alternate between displaying the status of the Temperature Controller (auto/ manual, RUN/RESET, and alarms) and the PV or SV. Flexible contact s with logic operations (AND, OR, and delays) set from the Support Software (C-Thermo version 4.3). Program settings can be managed. An infrared ports enables communications from the front panel. Preventive maintenance for relays in the Temperature Controller using a Control Output / Counter. available with position-proportional control. * Refer to Safety Precautions for E5@N/E5@N-H/ E5@N-HT. 96 96 mm E5AN-HT 48 96 mm For the most recent information on models that have been certified for safety standards, refer to your OMR website. E5AN-HTPRRB@-5, PRRB@-5 in this catalog have been discontinued at the end of March 8. Refer to Operation for E5@N/E5@N-H/E5@N-HT for operating procedures. Main I/O Functions * Orders will not be accepted after March 3, 8. Remote Input One Event Inputs None Two Four E5AN-HT Three displays for simultaneous display of the PV, SV, program, and segment. 5-digit Display with high resolution of. C Universal Sensor Inputs Universal thermocouple/ Pt/analog (current/voltage) s. Indication Accuracy Thermocouple/Pt : ±.% of PV Analog : ±.% FS Sampling Period 6 ms PF Key (Programmable key function) Infrared port USB Control Output Output Unit Relay Voltage (for driving SSR) Current Linear voltage Control Output Output Unit Relay Voltage (for driving SSR) Current Linear voltage Auxiliary Outputs Two Three Computer Support Software C-Thermo Programmable function 8 programs 3 segments Auto/manual switching Temperature Controller status display Simple program function Logic operations Control / count alarm PV change rate alarm s available with RS-485, RS-4, or RS-3C communications

Lineup E5AN-HT/ Programmable Type Terminal block Fully universal control auxiliary s control s auxiliary s Note: The Controller can be used for heating/cooling control even if only control is used. Number Structure Number Legend Controllers E5AN/E5EN-@@@@@@@M@-@-5 3 4 5 6 7 8 9. Type HT: Programmable. Control Mode Blank: Standard or heating/cooling control P: Position-proportional control * 3. Control Output A: Control Output Unit R: Relay * 4. Control Output A: Control Output Unit R: Relay * 5. Auxiliary Outputs : Two s 3: Three s 6. Option Blank: None H: Heater burnout/ssr failure/heater overcurrent detection (CT) HH: Heater burnout/ssr failure/heater overcurrent detection (CT) 7. Option B: Two event s BF: Event + Transfer Option Units E53-@. Function EN: RS-3C communications EN: RS-4 communications EN3: RS-485 communications AKB: Event Output Units E53-@@. Control Output R: Relay Q: Voltage (for driving SSR) Q3: Voltage (for driving SSR) + 4 VDC (NPN) Q4: Voltage (for driving SSR) + 4 VDC (PNP) C3: Current + 4 to ma DC C3D: Current + to ma DC V34: Linear voltage + to VDC V35: Linear voltage + to 5 VDC. Version Blank: Available for E5AN-H/E5EN-H/E5AN-HT/. N: Available only for E5AN-H/E5EN-H and E5AN-HT/. 8. Option 3 M: Option Unit can be mounted. 9. Power Supply Voltage Blank: to 4 VAC D: 4 VAC/VDC.Case Color Blank: Black.Terminal Cover -5: With Terminal Cover * Orders will not be accepted after March 3, 8. Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMR representative for details. This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN-HT/E5AN-HT/ Digital Controllers User's Manual Programmable Type (Cat. No. H69) E5CN-HT/E5AN-HT/ Digital Controllers Communications Manual Programmable Type (Cat. No. H7)

Ordering Information E5AN-HT Size /4 DIN 96 96 78 (W H D) Case color Black Power supply voltage to 4 VAC 4 VAC/ VDC Control method Basic Auxiliary * Orders will not be accepted after March 3, 8. Valve Basic Control / Heater burnout Control Output Unit Control Output Unit 3 Control Output Unit Valve Relay s Relay s Control Output Unit Control Output Unit 3 Control Output Unit Relay s Relay s Event s Optional functions Transfer R E5AN-HT/ E5AN-HTAAHBM-5 E5AN-HTAAHHBFM-5 E5AN-HTAA3BFM-5 E5AN-HTPRRBM-5 * E5AN-HTPRRBFM-5 * E5AN-HTAAHBMD-5 E5AN-HTAAHHBFMD-5 E5AN-HTAA3BFMD-5 E5AN-HTPRRBMD-5 * E5AN-HTPRRBFMD-5 * Size /8 DIN 48 96 78 (W H D) Case color Black Power supply voltage to 4 VAC 4 VAC/VDC Control method Basic * Orders will not be accepted after March 3, 8. Auxiliary Valve Basic Control / Control Output Unit Control Output Unit 3 Control Output Unit Valve Relay s Relay s Control Output Unit Control Output Unit 3 Control Output Unit Relay s Relay s Event s Optional Functions Transfer R AAHBM-5 AAHHBFM-5 AA3BFM-5 PRRBM-5 * PRRBFM-5 * AAHBMD-5 Heater burnout AAHHBFMD- 5 AA3BFMD-5 PRRBMD-5 * PRRBFMD-5 * 3

Accessories (Order Separately) Output unit Specifications Relay Voltage (for driving SSR) Current Linear voltage USB-infrared Conversion Cable USB-Serial Conversion Cable Terminal Cover E53-RN E53-QN E53-Q3 E53-Q4 E53-C3N E53-C3DN E53-V34N E53-V35N Connectable models E5AN-HT E53-COV6 Note: The Terminal Cover comes with the E5AN/E5EN-@@@-5 models. Mounting Brackets Y9H-9 Note: These Mounting Brackets are provided with the Digital Controller. Waterproof Packing Connectable models E5AN-HT Y9S-P5 Note: The Waterproof Packing is included with the Controller. Current Transformers (CTs) C-Thermo Support Software ST-NO, 5 VAC, 5 A (resistive load), electrical life:, operations VDC (PNP), max. load current: 4-mA, with short-circuit protection 4 VDC (NPN), max. load current: -ma, with short-circuit protection 4 VDC (PNP), max. load current: -ma, with short-circuit protection DC, load: 6 Ω max., resolution: approx., to -ma DC, load: 6 Ω max., resolution: approx., to VDC, load: kω min., resolution: approx., to 5 VDC, load: kω min., resolution: approx., E58-CIFIR E58-CIFQ Y9S-P4 Hole diameter 5.8 dia. E54-CT. dia. E54-CT3 EST-C-MV4 4

Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor Input impedance Control method Relay Control Voltage (for driving SSR) Current Linear voltage Number of s E5AN-HT/ No D in model number: to 4 VAC, 5/6 Hz D in model number: 4 VAC, 5/6 Hz; 4 VDC 85% to % of rated supply voltage to 4 VAC: VA 4 VAC/VDC: 8.5 VA (4 VAC)/5.5 W (4 VDC) Any of the following can be selected. Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt or JPt Current : 4 to ma or to ma Voltage : to 5 V, to 5 V, or to V Current : 5 Ω max., Voltage : MΩ min. (Use a : connection when connecting the ES-HB-N.) / control or -PID control (with auto-tuning) Output Unit (Install the Output Unit (sold separately).) or 3 max. Auxiliary Relay : ST-NO, 5 VAC, 3 A (resistive load), electrical life:, operations, minimum applicable load: 5 V, Output specifications ma Number of s or 4 (with an E53-AKB) Event Contact : : kω max., : kω min. External contact specifications Non-contact : : Residual voltage:.5 V max., : Leakage current:. ma max. Current flow: Approx. 7 ma per contact Number of operations 8 max. Logic operation: Any of the following four patterns can be selected. The status may be inverted. (A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B, C, and D are four s.) Operations Delay: delay or delay for the results of the logic operation given above. Logic Setting time: to 9999 s or to 9999 min operations Output inversion: Possible Output One work bit per operation Any of The following can be assigned to up to eight work bits (logic operation results): operation commands (assigned to event Work bit s) *, auxiliary s, or control s. assignment * Application is possible with models that do not have event s by using an internal assignment. Transfer Number of s max. (Depends on model. s with transfer (F in model number) s Output specifications Current : 4 to ma DC, Load: 6 Ω max., Resolution at 4 to ma: Approx., Number of s Signal type Current : 4 to ma ( impedance: 5 Ω ±%) R Analog scaling Accuracy Input sampling period Setting method Indication method Other functions Scaling of signal to engineering units (EU) 9,999 to 3, (display: 3, max.) (±.% of FS) ± digit max. 6 ms Set digitally using keys on the front panel or by using the R. -segment digital display and individual indicators (7-segments displays also possible) Character height: E5AN-HT: PV: 5.8 mm, SV: 9.5 mm, MV: 6.8 mm; : PV:.8 mm, SV: 8. mm, MV: 5.8 mm Three displays: PV/SV/Program number/segment number, PV/SV/MV, or PV/SV/Remaining segment time. Number of digits: 5 for PV and SV, 4 for MV Manual, heating/cooling control, loop burnout alarm, other alarm functions, heater burnout detection (including SSR failure and heater overcurrent detection), 4% AT, % AT, MV limiter, digital filter, temperature shift, run/reset, protection functions, control / counter, extraction of square root, MV change rate limit, PV/SV status display, automatic cooling coefficient adjustment, program control functions, etc. Ambient operating temperature to 55 C (with no condensation or icing), for 3-year warranty: to 5 C Ambient operating humidity 5% to 85% Storage temperature 5 to 65 C (with no condensation or icing) 5

Input Ranges Thermocouple/Platinum Resistance Thermometer/Analog Input (Fully Universal Inputs) Temperature range ( C) Input type Platinum resistance thermometer Thermocouple Name Pt JPt K J T E L U N R S B W PL II 3. 3 8. 8 7.7. 7 6 5 4 3. 3. 3. 3 85. 85. 85. 9 8 7 6. 6 5. 5. 5. 5 4. 4. 4. 4. 4. 4 3.............. 5.. 5... 5. 5... Setting number. 99.9 99.9.. 99.9.. 99.9. 4 to m A Analog to m A to 5V to 5V Usable in the following ranges by scaling: 9999 to 34, 999.9 to 34., 99.99 to 34., or 9.999 to 3.4 4 3 4 5 6 7 8 9 3 3 4 5 6 7 8 9 5 6 7 8 9 to V Shaded settings are the default settings. The applicable standards for the types are as follows: K, J, T, E, N, R, S, B: JIS C 6-995, IEC 584- L: Fe-CuNi, DIN 437-985 U: Cu-CuNi, DIN 437-985 W: W5Re/W6Re, ASTM E988-99 JPt: JIS C 64-989, JIS C 66-989 Pt: JIS C 64-997, IEC 75 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard) 6

Alarm Outputs Each alarm can be independently set to one of the following 5 alarm types. The default is : Upper limit. Auxiliary s are allocated for alarms. delays and delays ( to 999 s) can also be specified. Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm will be an OR of the alarm selected from the following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To only a heater burnout alarm, SSR failure alarm, and heater overcurrent alarm for alarm, set the alarm type to (i.e., no alarm function). Set value Alarm type *. With set values, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as L and H. *. Set value:, Upper- and lower-limit alarm *3. Set value: 4, Upper- and lower-limit range H >, L < H L H L *4. Set value: 5, Upper- and lower-limit with standby sequence For Upper- and Lower-Limit Alarm Described Above Case and Always when the upper-limit and lower-limit hysteresis overlaps. Case 3: Always Alarm operation When alarm value is positive When alarm value is negative Description of function Alarm function Output No alarm L H Set the deviation in the set point by setting the alarm Upper- and lower-limit * * upper limit (H) and alarm lower limit (L). Upper-limit 3 Lower-limit 4 Upper- and lower-limit range * *3 5 Upper- and lower-limit with standby sequence * 6 Upper-limit with standby sequence 7 Lower-limit with standby sequence 8 Absolute-value upper-limit 9 Absolute-value lower-limit Absolute-value upper-limit with standby sequence Absolute-value lower-limit with standby sequence LBA (alarm type only) --- *8 3 PV change rate alarm --- *9 4 R absolute value upper limit *6 5 R absolute value lower limit *6 Case L H H <, L > H < L Case L H H <, L > H < L Case L H H >, L < H > L Case L H H >, L < H > L *5 Case 3 (Always ) H H L H L L Case 3 (Always ) H H L L L L H H H <, L < H <, L > H L H >, L < H L H <, L < H <, L > H L *4 Set the upward deviation in the set point by setting the alarm value (). Set the downward deviation in the set point by setting the alarm value (). Set the deviation in the set point by setting the alarm upper limit (H) and alarm lower limit (L). A standby sequence is added to the upper- and lower-limit alarm (). *7 A standby sequence is added to the upper-limit alarm (). *7 A standby sequence is added to the lower-limit alarm (3). *7 The alarm will turn if the process value is larger than the alarm value () regardless of the set point. The alarm will turn if the process value is smaller than the alarm value () regardless of the set point. A standby sequence is added to the absolute-value upper-limit alarm (8). *7 A standby sequence is added to the absolute-value lower-limit alarm (9). *7 The alarm turns when the remote (R) is larger than the alarm value (). This alarm functions in both Local and Remote Modes. The alarm turns when the remote (R) is smaller than the alarm value (). This alarm functions in both Local and Remote Modes. *5. Set value: 5, Upper- and lower-limit with standby sequence Always when the upper-limit and lower-limit hysteresis overlaps. *6. Displayed when there is a remote. *7. Refer to the E5CN-HT/E5AN-HT/ Digital Controllers User's Manual (Cat. No. H69) for information on the operation of the standby sequence. *8. Refer to the E5CN-HT/E5AN-HT/ Digital Controllers User's Manual (Cat. No. H69) for information on the loop burnout alarm (LBA). *9. Refer to the E5CN-HT/E5AN-HT/ Digital Controllers User's Manual (Cat. No. H69) for information on the PV change rate alarm. 7

Characteristics Indication accuracy Transfer accuracy Thermocouple: (±.% of indicated value or ± C, whichever is greater) ± digit max. * Platinum resistance thermometer: (±.% of indicated value or ±.5 C, whichever is greater) ± digit max. Analog : ±.% FS ± digit max. CT : ±5% FS ± digit max. ±.3% FS max. Influence of temperature * Thermocouple (R, S, B, W, PL II): (±% of PV or ± C, whichever is greater) ± digit max. Other thermocouple : (±% of PV or ±4 C, whichever is greater) ± digit max. *3 Platinum resistance thermometer: (±% of PV or ± C, whichever is greater) ± digit max. Analog : (±%FS) ± digit max. Influence of voltage * Influence of EMS. (at EN 636-) Input sampling period 6 ms Hysteresis Temperature :. to 34. C or F (in units of. C or F) Analog :.% to 99.99% FS (in units of.% FS) Proportional band (P) Temperature :. to 34. C or F (in units of. C or F) Analog :.% to 999.9% FS (in units of.% FS) Integral time (I). to 34. s (in units of. s) Derivative time (D). to 34. s (in units of. s) Control period.5, to 99 s (in units of s) Manual reset value. to.% (in units of.%) Alarm setting range 9999 to 34 (decimal point position depends on type) Affect of signal source resistance Insulation resistance Dielectric strength Vibration Malfunction resistance Destruction Shock Malfunction resistance Destruction E5AN-HT Weight Degree of protection Memory protection Setup Tool Setup Tool port Standards Approved standards Conformed standards Thermocouple:. C/Ω max. ( Ω max.) Platinum resistance thermometer:. C/Ω max. ( Ω max.) MΩ min. (at 5 VDC),3 VAC, 5 or 6 Hz for min (between terminals with different charge) to 55 Hz, m/s for min each in, Y, and Z directions to 55 Hz,.75-mm single amplitude for hrs each in, Y, and Z directions m/s, 3 times each in, Y, and Z directions 3 m/s, 3 times each in, Y, and Z directions Controller: Approx. 3 g, Mounting Bracket: Approx. g Controller: Approx. 6 g, Mounting Bracket: Approx. g Front panel: IP66, Rear case: IP, Terminals: IP Non-volatile memory (number of writes:,, times) C-Thermo version 4. or higher Provided on the bottom of the E5AN-HT and. An E58-CIFQ USB-Serial Conversion Cable is required to connect the computer to the E5AN-HT and. Provided on the front of the E5AN-HT and. An E58-CIFIR USB-infrared Conversion Cable is required to connect the computer to the E5AN-HT or. *4 UL 6-, CSA C. No. - EN 6- (IEC 6-): Pollution level, overcurrent category II EMI: EN 636- *5 Radiated Interference Electromagnetic Field Strength: EN 55 Group, class A Noise Terminal Voltage: EN 55 Group, class A EMS: EN 636- *5 ESD Immunity: EN 6-4- EMC Electromagnetic Field Immunity: EN 6-4-3 Burst Noise Immunity: EN 6-4-4 Conducted Disturbance Immunity: EN 6-4-6 Surge Immunity: EN 6-4-5 Power Frequency Magnetic Field Immunity: EN 6-4-8 Voltage Dip/Interrupting Immunity: EN 6-4- *. The indication accuracy of K thermocouples in the to 3 C range, T and N thermocouples at a temperature of C max., and U and L thermocouples at any temperatures is ± C ± digit max. The indication accuracy of the B thermocouple at a temperature of 4 C max. is not specified. The indication accuracy of B thermocouples in the 4 to 8 C range is ±3 C max. The indication accuracy of the R and S thermocouples at a temperature of C max. is ±3 C ± digit max. The indication accuracy of W thermocouples is ±.3% of PV or ±3 C, whichever is greater, ± digit max. The indication accuracy of PL II thermocouples is ±.3% of PV or ± C, whichever is greater, ± digit max. *. Ambient temperature: C to 3 C to 55 C, Voltage range: 5% to % of rated voltage *3. K thermocouple at C max.: ± C max. *4. External communications (RS-3C, RS-485, or RS-4) and cable communications for the Setup Tool can be used at the same time. *5. Industrial electromagnetic environment (EN/IEC 636- Table ) 8

Program Control Number of programs (patterns) 8 Number of segments (steps) 3 Segment setting method Segment times Alarm setting Reset operation Startup operation PID sets Alarm function Program status control Wait operation Time signals Program status Program startup operation Operation end operation Program shift Time setting (Segment set with set point and time.) Gradient setting (Segment type with set point, gradient, and time.) h min to 99 h 59 min min s to 99 min 59 s Set separately for each program. Select either stopping control or fixed operation. Select continuing, resetting, manual operation, or run mode. Number of sets 8 Setting method Set separately for each program (automatic PID group selection also supported). Select from ramp and target. Segment operation Advance, hold Program operation Program repetitions and program links Wait method Waiting at segment ends Wait width setting Same wait width setting for all programs Number of s Number of / each per Operations Setting method Set separately for each program. Program end (pulse width can be set), run, stage PV start Select from segment set point, slope-priority PV start h min to 99 h 59 min Standby day h to 99 day 3h Select from resetting, continuing control at final set point, and fixed control. Same program shift for all programs 9

USB-Serial Conversion Cable Applicable OS Windows P/Vista/7/8 Applicable software C-Thermo version 4 or higher E5AN/E5EN/E5CN/E5CN-U/E5AN-H/ Applicable models E5EN-H/E5CN-H/E5AN-HT// E5CN-HT USB interface standard Conforms to USB Specification.. DTE speed 384 bps Computer: USB (type A plug) Connector specifications Temperature Controller: Setup Tool port (on bottom of Controller) Power supply Bus power (Supplied from USB host controller.) Power supply voltage 5 VDC Current consumption 7 ma Ambient operating temperature to 55 C (with no condensation or icing) Ambient operating humidity % to 8% Storage temperature to 6 C (with no condensation or icing) Storage humidity % to 8% Altitude, m max. Weight Approx. g Note: A driver must be installed in the personal computer. Refer to installation information in the operation manual for the Conversion Cable. Communications Specifications Transmission line connection method Communications Synchronization method Protocol Baud rate Transmission code Data bit length * Stop bit length * Error detection Flow control Interface Retry function Communications buffer Communications response wait time RS-485, RS-4: Multipoint RS-3C: Point-to-point RS-485 (two-wire, half duplex) RS-4 (four-wire, half duplex) or RS-3C Start-stop synchronization CompoWay/F or Modbus, 4, 48, 96, 9, 384, or 576 bps ASCII (CompoWay/F) RTU (Modbus) 7 or 8 bits or bits Vertical parity (none, even, odd) Block check character (BCC) with CompoWay/F or CRC-6 Modbus None RS-485, RS-4, or RS-3C None 7 bytes to 99 ms Default: ms * The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the Communications Setting Level. Current Transformer (Order Separately) Ratings USB-Infrared Conversion Cable Applicable OS Windows P/Vista/7/8 Applicable software C-Thermo version 4. or higher Applicable models E5AN-H/E5EN-H/E5AN-HT/ USB interface standard Conforms to USB Specification.. DTE speed 384 bps Computer: USB (type A plug) Connector specifications Temperature Controller: Infrared port (on front of Controller) Power supply Bus power (Supplied from USB host controller.) Power supply voltage 5 VDC Current consumption 8 ma Ambient operating temperature to 55 C (with no condensation or icing) Ambient operating humidity % to 8% Storage temperature to 6 C (with no condensation or icing) Storage humidity % to 8% Altitude, m max. Weight Approx. 3 g (with mounting adaptor) Note: A driver must be installed in the personal computer. Refer to installation information in the operation manual for the Conversion Cable. Heater Burnout Alarms, SSR Failure Alarms, and Heater Overcurrent Alarms CT (for heater current detection) Maximum heater current Input current indication accuracy Heater burnout alarm setting range * SSR failure alarm setting range * Heater overcurrent alarm setting range *3 s with detection for single-phase heaters: One s with detection for single-phase or three-phase heaters: Two s 5 A AC ±5% FS ± digit max.. to 49.9 A (in units of. A) Minimum detection time: ms. to 49.9 A (in units of. A) Minimum detection time: ms. to 49.9 A (in units of. A) Minimum detection time: ms *. For heater burnout alarms, the heater current will be measured when the control is, and the assigned to the alarm function will turn if the heater current is lower than the set value (i.e., heater burnout detection current value). *. For SSR failure alarms, the heater current will be measured when the control is, and the assigned to the alarm function will turn if the heater current is higher than the set value (i.e., SSR failure detection current value). *3. For heater overcurrent alarms, the heater current will be measured when the control is, and the assigned to the alarm function will turn if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical Life Expectancy Curve for Relays (Reference Values) Dielectric strength, VAC for min Vibration resistance 5 Hz, 98 m/s Weight Accessories (E54-CT3 only) E54-CT: Approx..5 g, E54-CT3: Approx. 5 g Armatures () Plugs () No. of operations ( 4 ) 5 3 5 3 E5AN-HT/ 5 VAC, 3 VDC (resistive load) cosφ = 5 3 3 4 5 6 Switching current (A)

External Connections Control and control are functionally isolated from the internal circuits. Controllers Option Units The Temperature Controller is set for a K-type thermocouple ( type = 5) by default. An error (s.err) will occur if the type setting does not agree with the temperature sensor. Check the type. E53-EN RS-3C SD 3 RD SG E53-EN RS-4 3 Communications RDB RDA SG E53-EN3 RS-485 B (+) 3 A ( ) DO NOT USE E53-AKB Event Inputs EV EV 3 DO NOT USE SDB B (+) to 4 VAC 4 VAC/VDC (no polarity) DO NOT USE SDA A ( ) Input power supply Event Inputs * EV EV Control Control 3 4 5 6 3 4 5 6 3 4 5 6 CT CT CT Potentiometer *3 O W C 4 5 6 Auxiliary 3 Auxiliary 3 Relay DT, 5 VAC, 3 A (resistive load) Auxiliary Auxiliary 7 8 9 7 8 9 3 7 8 9 DO NOT USE DO NOT USE DO NOT USE A B B DO NOT USE DO NOT USE V DO NOT USE ma DO NOT USE A heater burnout alarm, SSR failure, heater overcurrent alarm, alarm, or Remote Input Error is sent to the to which the alarm function is assigned. Control Output Unit s with Positionproportional Control *3 Event */ Transfer / Remote * Control s, Control Output Unit Control s, Refer to page 4 s with Positionproportional Control Relay *3 5 VAC, A (including inrush current) Auxiliary s,, 3 Relay ST-NO, 5 VAC, 3 A (resistive load) Input power supply + 3 Output unit 4 + 5 Output unit 6 7 Auxiliary 8 9 Auxiliary Input power supply Open Closed 3 4 5 6 7 Auxiliary 8 9 Auxiliary EV3 DO NOT USE EV4 3 4 5 6 + 7 4 to ma DC Transfer (Load: 6 Ω max.) 8 + 9 Remote 4 to ma DC 3 Note: Wire all voltage terminals correctly. The Controller may fail if voltage terminals are wired incorrectly. *. EV3 and EV4 are assigned to event s in controllers with two event s. *. Terminals to 3 exist only on the following models. s with four event s (E5@N-@BB@) s with a transfer (E5@N-@F@) *3. Orders will not be accepted after March 3, 8.

Isolation/Insulation Block Diagrams E5AN-HT/ Nomenclature E5AN-HT Temperature unit Operation indicators Operation indicators No. display Temperature unit No. display No. display No. display No.3 display Operation indicators No.3 display Programmable Function Key/ Auto/Manual Key Up Key Down Key Mode Key Level Key Up Key Programmable Function Key/ Auto/Manual Key Level Key Mode Key Infrared communications reception port Down Key Infrared communications reception port

Dimensions E5AN-HT E5AN-HT/ Mounted Separately Group Mounted * 9 +.8 (96 number of units 3.5) +. (Unit: mm) 9 +.8 6 79. 96 96 9 min. 9 +.8 Group mounting does not allow waterproofing. Recommended panel thickness is to 8mm. Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.) To mount the Controller so that it is waterproof, insert the waterproof packing onto the Controller. When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. * Group mounting is not possible if an E53-C3N or E53-C3DN Output Unit is used for control or. For these combinations, maintain the following mounting space between Controllers. 9 +.8 min. Waterproof Packing (Accessory, Y9S-P4 (also available for ordering separately)) Mounting Bracket (Accessory, Y9H-9 (also available for ordering separately)) Terminal Cover (E53-COV6) (Accessory) Crimp terminal size: M3.5 9 +.8 min. 3

Mounted Separately Group Mounted * (48 number of units.5) +. 45 +.6 9 +.8 min. Group mounting does not allow waterproofing. 48 6 79. 9 +.8 Recommended panel thickness is to 8 mm. Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.) When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. 96 9 * Group mounting is not possible if an E53-C3N or E53-C3DN Output Unit is used for control or. For these combinations, maintain the following mounting space between Controllers. 45 +.6 6 min. Waterproof Packing (Accessory, Y9S-P5 (also available for ordering separately)) Mounting Bracket (Accessory, Y9H-9 (also available for ordering separately)) Terminal Cover (E53-COV6) (Accessory) Crimp terminal size: M3.5 9 +.8 min. 4

Accessories (Order Separately) USB-Infrared Conversion Cable E58-CIFIR USB-Infrared Conversion Cable (,) 54 35.8 USB connector (type A plug) 4.6 dia. LED indicator: RD LED indicator: SD 7.8 With Mounting Adapter Connected Mounting Adapter 39 6 8.5 Mounting Adapter (Accessory) 99..8 (75) 3. USB-Serial Conversion Cable E58-CIFQ (,) 5 LED indicator: SD,765 USB connector (type A plug) LED indicator: RD Serial connector Terminal Covers E53-COV6 (Six Covers provided.). 3. Mounting Brackets Y9H-9 (pcs) 67 8.5 44.8 4. One set is packaged with the product. Order Mounting Brackets separately if yours are lost or damaged. 5

Waterproof Packing Y9S-P4 (for DIN 96 96) Y9S-P5 (for DIN 48 96) Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection. (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMR shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required. Current Transformers E54-CT 5 3 5 5.8 dia..8 7.5 E54-CT Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current: 5 A (5/6 Hz) Number of windings: 4± Winding resistance: 8± Ω E54-CT3 4 3 3.5 Two, 3.5 dia..36 dia. dia. 9 Output voltage (Eo) V (r.m.s.) V 5 Hz mv μv kω Ω RL = Ω 3% % Distortion factor % E54-CT3 Accessory Armature Approx. 3 dia. Plug 8 4 4 Two, M3 (depth 4) 5 3 Connection Example Armature Plug Lead ma, A Thru-current (Io) A (r.m.s.) E54-CT3 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current: A (5/6 Hz) (Maximum continuous heater current for an OMR Temperature Controller is 5 A.) Number of windings: 4± Winding resistance: 8±.8 Ω Output voltage (Eo) V (r.m.s.) V 5 Hz mv kω 5 Ω Ω 5 Ω RL = Ω Distortion factor % 3% % Approx. 6 dia. μv () ma, A Thru-current (Io) A (r.m.s.) 6

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMR representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMR MAKES NO WARRANTY OR REPRESENTATI, EPRESS OR IMPLIED, ABOUT N-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMR COMPANIES SHALL NOT BE LIABLE FOR ECIAL, INDIRECT, INCIDENTAL, OR CSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTI OR COMMERCIAL LOSS IN ANY WAY CNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATI INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMR PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMR Corporation Industrial Automation Company http://www.ia.omron.com/ 9. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMR Corporation 9 All Right Reserved.