Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

Similar documents
Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

THE SAFE USE OF ELECTRICITY

Electrical Safety Policy

HEALTH & SAFETY ARRANGEMENTS FOR PORTABLE APPLIANCE INSPECTION & TESTING

Managing Ex Asset Integrity

Guide to Membership Assessments

Your specialist partner for total electrical compliance. Electrical Testing

Risk Control Guide ELECTRICAL EQUIPMENT

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

Understanding and implementing an electrical safety regime in your organisation. Dispelling the myths and promoting a risk-based approach

User Information Sheet 008 : 2010

POLICY FOR THE SAFE WORKING WITH ELECTRICITY

Periodic Electrical Testing Policy

Legislation & Standards

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

ATEX 137. What it means for motor users

Training, Assessment, Consultants for Hazardous & Industrial Areas

Electrical Management

PERIODIC ELECTRICAL TESTING POLICY

The Facilities Manager s Guide to: Electrical Testing, Fire Alarms and Emergency Lighting Regulations. Updated May 2016

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

BSc MBA EngD DMS PGCE CEng CSci CEnv FIMMM MIET MCMI. Confined Spaces. Mining. Rope Cableways

A BARBOUR GUIDE. Fire Precautions and Fire Protection

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Guidance on Safe Operation of Boilers Ref: BG01

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

Electrical Safety Policy and Management System

Sip Vacuum Cleaner 1400/35 Wet & Dry

Electrical Safety Requirements

DEVIL CERAMIC SPACE HEATERS

Whole Room Dryer WRD, WRD/110

ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR. FOX Model F50-843

ENVIROPRESS CAN CRUSHER Model : EP005 / EP005HD

Services. Monitoring. t f e. w.

Electrical Safety The Hidden Perils

ASSEMBLY AND OPERATING INSTRUCTIONS 1HP DUST EXTRACTOR. FOX Model F50-841

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Fire Safety Policy Date: 0

Insight a closer look at Classroom safety

16 Ultiflame Inset Electric Fire

200W Frostwatch Radiant Heater Operation Manual

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa

5KW ELECTRIC FAN HEATER

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

CRU-S Series Stainless Steel Condensate Recovery Unit

DISTRIBUTION LIST. Pre-Construction Safety Report Chapter 25 Conventional Safety and Fire Safety UK HPR1000 GDA. GNS Executive.

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Presentation to. IOSH Food and Drink Group. Danny McDougall Richard Perkin

Project Briefing Document. Section 3 Electrical Services design guide and specifications

Electrical connections for gas metering equipment

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

The new fire regulations - more demands on the employer? The Regulatory Reform (Fire Safety) Order 2005

Important Notes: Please read carefully before installing your refrigerator.

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

3KW ELECTRIC FAN HEATER

FEATHERWEIGHT PRO USER GUIDE 1703 SERIES

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Installation Instructions & Operating Manual IMPORTANT

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

HazLoc Essential Guides:

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

H&S Forum. Fire Safety Policy Glascote Academy

Alan Wells Technical and Standards Director Certsure LLP trading as NICEIC

15KW ELECTRIC FAN HEATER

16 XD Mk2 Inset Electric Fire

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

ASSEMBLY AND OPERATING INSTRUCTIONS PADDLE MIXER. FOX Model F V / 110V

CONSULTING Training Courses

30KW ELECTRIC FAN HEATER

Level 2 Award in Fire Safety (QCF) (SCQF Level 5 in Scotland) Unit 1 title: Fire safety principles

Instructions for Use. Electric Pole Hedge Trimmer Input Power Tooth gap of cutter blade 16mm

Training Standard. Draft

ORIGINAL INSTRUCTIONS

domnick hunter PNEUDRI DME012-RX - DME080-RX USER GUIDE Original Language

Testing and Calibration Report

If there are more than ten people working other than on the ground floor,

Cross Cut Shredder UAV 380 A1

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

Qualification Specification Highfield Level 1 Award in the Principles of Fire Safety Awareness (RQF)

Consumer unit replacement in domestic and similar premises

Fire Safety. A TUC guide for trade union activists

RC11 First published 1979 Version 05 Risk Control Recommendations for fire safety in the use of lift trucks

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

INDEX INDEX 2 FOREWARD 3 SECTION 1 COMPANY INFORMATION 4 SECTION 2 GRADING AND CERTIFICATION 5 SECTION 3: ADDITIONAL REQUIREMENTS 6 7

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

POWER CUT Hedge Trimmer 46 Model No. 101HT450

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

INSTALLATION & USER INSTRUCTIONS

ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS (EEHA) TESTING STANDARD

Electrical Safety Policy

Beamex. Calibration White Paper. Calibration in hazardous areas

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Transcription:

Risk Management Services Electrical Safety Inspection and Testing We can show you more.

Risk Management Services Electricity is a potential hazard that impacts both personal safety and property. Adequate training, supervision, and risk assessment is critical to avoid electrical accidents. Guidance on safe working practices Install a management system to ensure that the electrical systems and equipment are installed, operated and maintained in a safe manner. Record findings of any hazards with the level of danger and steps taken to control the risks. Carry out a risk assessment to identify potential hazards as well as cost, effort, time, and difficulty in eliminating or significantly reducing any risk. Fixed installations testing and maintenance Fixed equipment, wiring and switchgear should be tested and maintained regularly. Inspection and testing should be carried out to identify and prioritise the maintenance requirements of the fixed electrical installation. Testing should be completed by an electrical contractor registered with the National Inspection Council for Electrical Installation Contracting (NICEIC) or the Electrical Contractors Association (ECA). The dangers of voltage Low voltage is commonly defined as up to 600V ac (Alternating Current) between conductors and earth or 1,000V ac between phases. The common mains voltage is within this category at 220-240V, 50Hz (where Hz = Hertz or cycles per second) Electrical injuries are caused by a wide range of voltages but the risk of injury is generally greater with higher voltages, but even a low voltage (such as that produced by a single battery) can produce a spark powerful enough to ignite an explosion If a person comes into contact with a voltage as low as 50 volts, they can suffer injuries, such as breathing or heart problems or indirect effects (e.g: falling from height or coming into contact with moving machinery) Environments with dampness or metalwork increase the risk of injury from electric shock Therefore, it is imperative that no work such as inspections, testing, and maintenance is carried out on or near any live electrical conductor unless: it is suitably covered with insulating material so as to prevent danger suitable precautions are taken including training, qualification, experience, and protective gear it is unreasonable in all circumstances for it to be isolated; or it is unreasonable in all circumstances for the person to be at work on or near it whilst its live.

Portable Electrical Equipment All systems and auxiliary equipment (e.g. extension leads, plugs, and sockets) should be maintained to prevent danger. Employees should be trained to carry out tests and use appropriate equipment to complete inspections. Inspections and maintenance logs should be updated to assist in scheduling future inspections and to demonstrate that an effective inspection and testing regime is in place. Portable Electrical Equipment should be subject to three levels of inspection: 1) A user check where the equipment is subjected to heavy work or used in harsh environmental conditions. These visual inspections should be more frequent by the user, e.g. at start of every shift. 2) A formal visual inspection, which may include: removing the plug cover and ensuring that a fuse is being used (e.g. it is a fuse of correct rating, correctly installed etc.) checking that the cord grip is effective checking that the cable terminations are secure and correct, including an earth where appropriate, and there is no sign of internal damage, overheating or ingress of liquid or foreign matter. This formal visual inspection may not include taking the equipment apart 3) A combined inspection and test should be carried out by a competent person with appropriate equipment. This may involve stripping the equipment down. The HSE publication HSG 107 Maintaining Portable and Transportable Electrical Equipment, provides a table of guidance on suggested initial maintenance intervals. However, the following factors should be considered before determining a suitable inspection and testing frequency: Type of equipment and whether it is hand-held or not Manufacturer s recommendations Initial integrity and soundness of equipment Age of the equipment Working environment in which the equipment is used (e.g. wet or dusty) or likelihood of mechanical damage Frequency of use and the duty cycle of the equipment Foreseeable abuse of the equipment Effects of any modifications or repairs to the equipment Analysis of previous records of maintenance, including both formal inspection and combined inspection and testing.

Electrical Safety - Inspection and Testing Thermographic surveillance Thermographic surveillance is recommended for fixed wiring of electrical installations. Handheld and/or fixed mounted infrared cameras are used to take images of both electrical installations and mechanical equipment. From the images or thermograms obtained, engineers can determine the operating conditions of electrical and mechanical equipment. The advantages of infrared thermography include minimising: business interruptions by: eliminating the need for scaffolding access facilitating scheduled downtime for repairs energy losses by identifying: energy inefficient machines breaches in thermal seals/insulation Electricity in potentially explosive locations Dangerous substances can put peoples safety at risk from fire and explosion. Employers and the self-employed have a duty to protect people from risks to their safety from fires, explosions and similar events in the workplace. This includes members of the public who may be put at risk by work activity A complete assessment is required to identify and classify areas of the workplace where explosive atmospheres may occur and avoid ignition sources in those areas Both fixed and portable specific electrical precautions are required in some circumstances. E.g. Explosion proof lighting for hazardous areas. Remember, any repair to electrical equipment within EPS (Equipment and Protective Systems intended for use in potentially explosive atmospheres) which affects any essential health and safety requirements, could be considered a substantial modification and therefore may require the equipment to be re-assessed.

Electrical Safety - Inspection and Testing Further Guidance: Memorandum of guidance on the Electricity at Work Regulations 1989. Guidance on Regulations HSR25 HSE - Electricity at work. Safe working practices HSE - Maintaining Portable and Transportable Electrical Equipment - HSG 107 HSE - Electrical safety and you - A brief guide - INDG231 HSE - Safety in electrical testing: - Switchgear and control gear - EIS37 BS7671: 2008 Amendment No.1: 2011 Requirements for Electrical Installations, IET Wiring Regulations 17th Edition. Inspection and Testing Guidance Notes 3 RISCAuthority RC30 - Selection of electrical and non-electrical equipment for use in atmospheres containing flammable and explosive gases or vapours BSI report PD CLC/TR 50404:2003 Electrostatics - Code of Practice for the avoidance of hazards due to static electricity Dangerous substances and Explosives Atmospheres Regulations 2002 (DSEAR) ATEX Directive 99/92/EC (ATEX Workplace Directive) ATEX Directive 94/9/EC (ATEX Equipment Directive)

About CNA Hardy CNA Hardy is a leading specialist commercial insurance provider for clients within the Lloyd s and company markets. CNA Hardy is part of CNA Financial Corp, one of the largest U.S. commercial property and casualty insurance companies. Established in 1897, CNA has approximately 7,000 employees, serving businesses and professionals in the U.S., Canada, Europe and Asia. CNA Hardy Dedicated to Risk Management Services At CNA Hardy, our Risk Management Services offering is aligned to the same four principles which drive our Winning Proposition: we offer more than just a policy - we deliver distinctive insurance solutions and we promise a superior customer service. People Supported by a team of over 300 risk management specialists globally. Our European Team are NEBOSH and UL Recognised Risk Engineers certified with specialist qualifications in the areas they assess. Product and service Our Risk Management Consultants arrange site visits to advise on the complex range of risks facing all businesses from manufacturing & construction to healthcare providers. Partnership We build collaborative relationships to compliment your existing resources to help you manage and identify risk across your business. Proven Track Record Our expertise allows us to identify and manage risks economically in order to protect lives, assets and profitability. 20 Fenchurch Street London EC3M 3BY United Kingdom Tel +44 (0)20 7743 6800 cnahardy.com The information contained in this document does not represent a complete analysis of the topics presented and is provided for information purposes only. It is not intended as legal advice and no responsibility can be accepted by CNA Hardy for any reliance placed upon it. Legal advice should always be obtained before applying any information to the particular circumstances. Please remember that only the relevant insurance policy can provide the actual terms, coverages, amounts, conditions and exclusions for an insured. All products may not be available in all countries. CNA Hardy is a trading name of CNA Insurance Company Limited ( CICL, company registration number 950) and/or Hardy (Underwriting Agencies) Limited ( HUAL, company registration number 1264271) and/or CNA Services (UK) Limited ( CNASL, company registration number 8836589) and/or CNA Hardy International Services Limited ( CHISL, company registration number 9849484) and/or CNA Insurance Company (Europe) S.A., UK Branch ( CICE UK, company registration number FC035780). CICL, HUAL and CICE UK are authorised by the Prudential Regulation Authority and regulated by the Financial Conduct Authority and the Prudential Regulation Authority (firm reference numbers 202777, 204843 and 822283 respectively). The above entities are all registered in England with their registered office at 20 Fenchurch Street, London, EC3M 3BY. VAT number 667557779. 30643/1218