Certificate of Compliance

Similar documents
Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certification Supplement Manual

Certificate of Compliance

Certificate of Compliance

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certification Supplement Manual

Certificate of Compliance

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Annubar Flowmeter Series

Field Certification Certificate of Compliance

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Certification Supplement Manual

User s Manual YTA610 and YTA710 NEPSI Certification

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 752 Fieldbus Remote Indicator

Technical Data. Dimensions

UL HAZARDOUS LOCATIONS SERVICES

IECEx Certificate of Conformity

Model 144H. Product Data Sheet , Rev DB February Content

Guide for hazardous areas

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 3051CFC Compact Flowmeter

Rosemount 644 Temperature Transmitter

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Ar-Mite TM Low Flow Armored Flowmeter

Technical Data. Dimensions

OPTIBAR DP 7060 Supplementary Instructions

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Rosemount 248 Temperature Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Inductive slot sensor

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

An Urgent Bulletin from CSA Group

Rosemount 2051T In-Line Pressure Transmitter

INSTRUCTION & SERVICE MANUAL

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Absolute and Gage Pressure Transmitter

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Quick Start Guide For the

Rosemount 248 Temperature Transmitter

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Quick Start Guide , Rev HA January Rosemount 248 Temperature Transmitter

standards: standards:

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Rosemount 2090P Pulp and Paper Pressure Transmitter

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Rosemount 3095MFC Compact Orifice Mass Flowmeter

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Tank Gauging System Special Safety Instruction

CERTIFICATE OF COMPLIANCE

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Technical Specification VFD

Rosemount 644H Temperature Transmitters

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Certificate of Compliance

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 702 Wireless Discrete Transmitter

Rosemount 3144P Rosemount 3144P Temperature Transmitter

IECEx Certificate of Conformity

PEPPERL+FUCHS GmbH

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Rosemount 3144P Temperature Transmitter

Rosemount 2051T In-line Pressure Transmitter

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Rosemount 3051L Level Transmitter

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Brooks MT3750 Low Flow Armored Flowmeter

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Transcription:

Certificate of Compliance Certificate: 70000097 Project: 70125347 Issued to: Thermo Engineering S.r.l Via Giuseppina, 19 26030 Malagnino (CR) Italy Attention: Mr. BOZZETTI The products listed below are eligible to bear the CSA Mark shown Issued by: E. Giusti E.Giusti PRODUCTS CLASS 2258 02 PROCESS CONTROL EQUIPMENT For Hazardous Locations CLASS 2258 82 PROCESS CONTROL EQUIPMENT For Hazardous Locations certified to U.S. standards Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx na IIC, T6, T5, T4 Ex na IIC T6, T5, T4 Temperature Sensor Probe models 215TE --/ExnA: Models 215TE02/ExnA, 215TE03/ExnA, 215TE04/ExnA, 215TE05/ExnA, 215TE06/ExnA, 215TE07/ExnA, 215TE08/ExnA, 215TE09/ExnA, 215TE10/ExnA and 215TE11/ExnA. Temperature Sensor Probe models 215TE02/ExnA to 215TE11/ExnA are rated 30VDC, 100mA max. Note: -Probes model 215TE02 and 215TE03 are certified as Component Type when delivered with flying leads in hazardous locations Class I, Division / Zone 2: they shall be protected integrally by suitable mechanical means (i.e. rigid conduit, certified liquid tight conduit, etc ). Suitability of the final assembly is determined by Local Authorities having jurisdiction. DQD 507 Rev. 2016-02-18 Page 1

-Probes provided with flying leads shall be connected either in safe area or in an enclosure suitably certified for the hazardous area. Class I, Division 1, Groups B, C, D Ex d IIC, T6, T5, T4 or T3 Class I, Zone 1, AEx d IIC, T6, T5, T4 or T3 Temperature Sensor Probe models 111TE---/Exd, rated 20 Vdc, 50 ma, 135 mw (per temperature sensing element) equipped with connection head model TST series and model TE-00041 series, ambient temperature from -60 C. Max.Ambient Temp. T-code Cable Temperature 70 C T6 70 C 85 C T5 80 C 120 C T4 120 C 180 C T3 180 C Model code: 111TE _/Exd 1st digit : process coupling 2nd digit : connection head material 3rd digit : output signal 4th digit : ambient temperature 5th digit : certified 6th digit : cable/conduit entry 0 : without thermowell 1 : threaded thermowell 2 : flanged thermowell 3 : skin-point assembly 4 : soldered thermowell 0 : Light alloy UNI 3049 1 : AISI 303 / 304 / 316 stainless steel 0 : without transmitter 1 : with transmitter Always 0 (Tamb.is written specially on the marking label) 2 : ATEX and CSA certified 3 : ATEX & IECEx and CSA certified 0 : 3/4 NPT 1 : 1/2 NPT 2 : 3/4 GK UNI6125 3 : 1/2 GK UNI6125 4 : 3/4 ISO228 5 : 1/2 ISO228 6 : M25x1,5 ISO 262 7 : M20x1,5 ISO 262 DQD 507 Rev. 2016-02-18 Page 2

8 : PG 16 DIN40430 9 : PG 13,5 DIN40430 Notes: - Probes provided with flying leads shall be connected either in safe area or in an enclosure suitably certified for the hazardous area. - gap and diametral clearance of the different flamepath is longer than the values specified in the table 1 of CAN/CSA C22.2 / ANSI/UL 60079-1. - length of the different flamepath are lower than the values specified in the table 1 of CAN/CSA C22.2 / ANSI/UL 60079-1. - As an option, CSA certified Temperature transmitter manufacturer by PR Electronics, model PR 5335D (T.E. code 00967) may be installed inside the connection head. In this case intrinsically safe parameters of the transmitter shall be taken from PR Electronics certificate and documentation. Class I, Zone 0, AEx ma IIC T6, T5, T4 Ex ma IIC T6, T5, T4 Temperature Sensor Probe models 113TE---/Exm, rated 1 Vdc, 3 ma (per temperature sensing element). Ambient temperature is as follows: - 50 C or -60 C + 70 C (T6) - 50 C or -60 C + 85 C (T5) - 50 C or -60 C + 120 C (T4) Model code: 113TE _/Exm 1st digit : probe type 0 : with connection head (see dwg 113TE03) 1 : with nipple (see drawing 113TE04) 3 : without sleeve (see drawing 113TE06) 2nd digit : thermowell 0 : without thermowell 1 : with thermowell 3rd digit : probe type 0 : simple RTD 1 : double RTD 2 : simple TC 3 : double TC CLASS 2258 04 PROCESS CONTROL EQUIPMENT Intrinsically safe entity-for Hazardous Locations CLASS 2258 84 PROCESS CONTROL EQUIPMENT Intrinsically safe entity For Hazardous Locations certified to U.S DQD 507 Rev. 2016-02-18 Page 3

Class I, Division 1, Groups A, B, C and D Class I, Zone 0, AEx ia IIC T6, T5, T4 Ex ia IIC T6, T5, T4 Temperature Sensor Probe models 215TE02/Ex ia to 215TE11/Exia, intrinsically safe with Entity parameters as per table below: IIC 30 100 5* 30* IIB 30 250 5* 30* IIA 30 340 5* 30* For dual probes product where the separation distance is below 0.5mm (resp.0.7mm) through the solid insulation (resp.through resin/compound), the entity parameters, for each probe are IIC 20 50 5* 30* IIB 20 130 5* 30* IIA 20 190 5* 30* Temperature probe models 215TE02/Ex ia, 215TE03/Ex ia, 215TE04/Ex ia, 215TE05/Ex ia, 215TE06/Ex ia, 215TE07/Ex ia and 215TE10/Ex ia are equipped with an integral cable when 215TE08/Exia, 215TE09/Exia and 215TE11/Exia are provided with cylindrical or conical threaded cable entry. Temperature probe model 215TE06 is insulated in Teflon or epoxy resin in order to be installed within slots of insulating material of stator windings. Thermal data for all probes: The temperature class of the probe models 215TExx/Ex ia and 215TExx/Ex na depend on the ambient and process temperatures as listed in the table below Temperature class of the Ambient temperature [ C] probes T6-50 / +70 T5-50 / +85 T4-50 / +120 Temperature probe models 112TE /Exia, intrinsically safe with entity parameters as per table below: DQD 507 Rev. 2016-02-18 Page 4

IIC 30 100 5* 30* IIB 30 250 5* 30* IIA 30 340 5* 30* Relation between T-code and Max Ambient Temp. is as follows, for Pi < 0.13W: Max.Ambient Temp. T-code Cable Temperature 70 C T6 80 C 85 C T5 95 C 120 C T4 130 C 180 C T3 190 C For dual probes product where the separation distance is below 0.5mm (resp.0.7mm) through the solid insulation (resp.through resin/compound), the entity parameters, for each probe are IIC 20 50 5* 30* IIB 20 130 5* 30* IIA 20 190 5* 30* Relation between T-code and Max Ambient Temp. is as follows, for Pi < 0.06W: Max.Ambient Temp. T-code Cable Temperature 70 C T6 80 C 85 C T5 95 C 120 C T4 130 C 180 C T3 190 C Output signals being 4 to 20 ma, 0 to 10 V, profi-bus or hart protocol (when transmitter is integrated in connection head.) As an option, CSA certified Temperature transmitter manufacturer by PR Electronics, model PR 5335D (T.E. code 00967) may be installed inside the connection head. In this case intrinsically safe parameters of the transmitter shall be taken from PR Electronics certificate and documentation. Model Code: 112TE _/Exia 1st digit : process coupling 0 : without thermowell DQD 507 Rev. 2016-02-18 Page 5

1 : threaded thermowell 2 : flanged thermowell 3 : skin-point assembly 4 : soldered thermowell 2nd digit : connection head material 0 : Light alloy UNI 3049 1 : AISI 303 / 304 / 316 stainless steel 3rd digit : output signal 0 : without transmitter 1 : with transmitter 4th digit : ambient temperature Always 0 (Tamb.is written specially on the marking label) Note: - Documentation for 112TE---/Exia includes the fact that the probes shall be supplied by galvanically isolated associated apparatus. Temperature probe models 114TE _ /Exia, intrinsically safe with entity parameters as per table below: IIC 30 100 5* 30* IIB 30 250 5* 30* IIA 30 340 5* 30* For dual probes product where the separation distance is below 0.5mm (resp.0.7mm) through the solid insulation (resp.through resin/compound), the entity parameters, for each probe are IIC 20 50 5* 30* IIB 20 130 5* 30* IIA 20 190 5* 30* Model code: 114TE _/Exia 1st digit : probe type 1 : with nipple (see drawing 114TE04) 3 : without sleeve (see drawing 114TE06) 4 : with stainless steel connection head (see drawing 114TE03) 2nd digit : thermowell 0 : without thermowell 1 : with thermowell DQD 507 Rev. 2016-02-18 Page 6

3rd digit : probe type 0 : simple RTD 1 : double RTD 2 : simple TC 3 : double TC The temperature class of the probe models 114TE---/Exia depends on the ambient and process temperatures as listed in the table below Temperature class of the probes Ambient temperature [ C] T6-50 or -60 / +70 T5-50 or -60 / +85 T4-50 or -60 / +120 APPLICABLE REQUIREMENTS CSA C22.2 No. 0-M91 -General Requirements - Canadian Electrical Code, Part II CAN/CSA C22.2 No. 142-M1987 (R2009) Process Control Equipments CSA C22.2 No. 157-M1992 - Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations CSA C22.2 No. 213-M2016 - Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations CSA C22.2 No 60079-0:15 - Explosive atmospheres - Part 0: Equipment - General requirements CSA C22.2 No 60079-1:16 - Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" CSA C22.2 No 60079-11:14 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety i CSA C22.2 No 60079-15:16- Electrical apparatus for explosive gas atmospheres - Part 15: Construction, test and marking of type of protection n electrical apparatus CSA C22.2 No 60079-18: 09 - Explosive atmospheres - Part 18: Encapsulation "m"; CSA C22.2 No. 30-M1986 (R2012) Explosion-Proof Enclosures for Use in Class I Hazardous Locations UL916: 2007 - Energy Management Equipment ISA 60079-0 (12.00.01): 2013 - Electrical Apparatus for Use in Class I, Zone 0, 1 & 2 Hazardous (Classified) Locations: General requirements ISA-60079-1 (12.22.01): 2009 R2013 - Electrical Apparatus for Use in Class I, Zone 1 Hazardous (Classified) Locations: Type of Protection Flameproof d ISA 60079-11 (12.02.01): 2014 - Electrical Apparatus for Use in Class I, Zone 0, 1 & 2 Hazardous (Classified) Locations - Intrinsic Safety i ISA 60079-15 (12.12.02): 2012 - Electrical Apparatus for Use in Class I, Zone 2 Hazardous (Classified) Locations: Type of protection n ANSI/ISA 60079-18 (12.23.01): 2009 - Explosive atmospheres - Part 18: Encapsulation "m"; FM3600 : 2011 - Electrical Apparatus for Use in Hazardous (Classified) Locations General Requirements FM3615 : 2006 - Explosionproof Electrical Equipment General Requirements DQD 507 Rev. 2016-02-18 Page 7

MARKINGS The manufacturer is required to apply the following markings: Products shall be marked with the markings specified by the particular product standard. Products certified for Canada shall have all Caution and Warning markings in both English and French. Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities. The products listed are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US (indicating that products have been manufactured to the requirements of both Canadian and U.S. Standards) or with adjacent indicator 'US' for US only or without either indicator for Canada only. Markings etched on metallic nameplates attached to temperature probes. 1. Submittor's identification (company name and/or file number and/or registered tradename); 2. Model designation; 3. Date of manufacture (or traceable serial number); 4. The CCSA US Monogram 5. Hazardous area; 6. Ambient temperature range; 7. Electrical ratings; 8. CSA Certificate number CSA.13. 70000097 9. Warning: DO NOT OPEN WHILE ENERGIZED/NE PAS OUVRIR SOUS TENSION on Ex d/flameproof connection head Markings are presented in drawings 111TE01, 112TE01, 113TE01, 114TE01, 215TE01. Note: the marking shown on drawing 215TE01 is also representative for 215TE02 and 03. Nameplate adhesive label material approval information: NA DQD 507 Rev. 2016-02-18 Page 8

Supplement to Certificate of Compliance Certificate: 70000097 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 70125347 November 16, 2017 Update to report 70000097 to include new options on existing models and to modify existing Ex ia parameters 70007567 October 30, 2014 Update to report 70000097 to include new options on existing models and to modify existing Ex ia 70000097 October 10, 2013 Original Certification DQD 507 Rev. 2016-02-18 Page 1