Spectrolink Comfort Controller. Home Owner's Manual Heating. baby, outside. Come home to ECOST R

Similar documents
Spectrolink Comfort Control. Home Owner's Manual Heating

HOME OWNER S MANUAL. Spectrolink Comfort Control - Heating

OWNER S MANUAL. CPL Evaporative Cooler. (English) (CPL) ILL1456-A

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

REMOTE CONTROL FAN SPEED ECONOMY BATTERY LOW. owner s manual

OWNER S. m a n u a l C P L S E R I E S

OWNER S MANUAL. Evaporative Cooler. (English) (EA, EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English)

GAS DUCTED HEATER TB SERIES

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller)

Important safety information

LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATED AIR OUTLET HEATER CONTROL PANEL

OWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS

Elegance. SMT-700 User manual. Ver

Using the. Ducted Gas Central Heating Dual Cycle Refrigerated Air Conditioning Ducted Evaporative Air Conditioning. with your.

Safety / Kit Components 1

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Wall Controller & Thermostat

Model: Slimline-N. 1 Slimline Series

Auto Drain Installation Instructions.

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

Model: Slimline-B. Battery Series

Underfloor Heating Programmable Thermostat

OPERATING INSTRUCTIONS

Owner s Manual MODEL 8555

Owner s Manual. Using the Ducted Gas Central Heating Dual Cycle Refrigerated Air Conditioning Ducted Evaporative Air Conditioning.

Auto Drain Installation Instructions.

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Model: Slimline-RF. 1 Slimline Series

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

INSTALLATION MANUAL. TBA Evaporative Cooler. (English) (TBA) ILL1456-A

ELECTRONIC THERMOSTAT

Model : PRT-EN Model: PRT-EN1

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

Rapid Response Series (RR e & RR i) OPERATING MANUAL

Model: Touch-RF. 1 Wireless Series

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

SAT-3 Room Temperature Controller

: PRT / PRT PRT / PRT-N1

Portable Air Conditioner Instruction Manual

INSTALLATION MANUAL TBA Evaporative Cooler

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

OWNER S MANUAL. SACC Series Add-On Cooling Unit. (English) (SACC)

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English) ILL1672-A

AC500T, AC1000T, AC1500T, AC2000T

Dual-Hose Portable Air Conditioner User Manual

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Model: PRT-TS / PRT-NTS

1F97-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 7-Day Programmable Electronic Digital Thermostat

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

GAS FIRE USER GUIDE IB600 IB850 IB G8861_5 Userguide NZ/AUS

Table 1. Serie of Digital Room Thermostats.

Model: Touch-RS. 1 Touch-RS

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

MPS OWNERS MANUAL. To all new customers buying a Brivis product for the first time, welcome!

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

SKOPE PEGASUS PG Vertical Series. Chillers and Freezers PG600VC PG1300VC. User Manual

VF Series. User Manual. SKOPE Vertical Freezer. MAN10521 Rev. 3.3 Jun VF1000

CS027 User Instructions

USER'S OPERATING INSTRUCTIONS

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

DYGIZONE GJD910 Lighting Controller & Enunciator

OWNER S MANUAL LCQ / LCS / LCQI / BMQ / CPQ TBQ / TBS / TBQI / TBSI Evaporative Cooler

C-Stat 17-ZW User Instructions

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Uponor Comfort-E Thermostat Dig. Prog Set T-86 INSTALLATION AND OPERATION MANUAL

SC Installation, Operation & Application Guide

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

Evolution Control. Zone Control Homeowner s Guide

OWNER S MANUAL IMPORTANT - INSTALLER MUST COMPLETE FOR WARRANTY PURPOSES. Made in Western Australia by:

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

VIGÖR HRV PLUS AND VIGÖR ERV

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

INITIALIZATION / INSTALLATION

SPA-QUIP LTD 3 BUTTON ELECTRONIC STANDARD SPA POOL CONTROLLER DEALER STAMP: DATE INSTALLED SERIAL NUMBER SOLD BY INSTALLED BY STARTUP TESTING

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller or Manual Thermostat)

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Programmable Thermostat

1F90W-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat WHITE-RODGERS

1F90-71 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat

Model: Edge-HC. 1 edge-hc

Read all instructions before proceeding. Store this manual for future reference

AUTO CM CM USER GUIDE

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

INSTALLATION MANUAL. CPL CPS LCB BM Evaporative Cooler. (English) (CPL CPS LCB BM) (Original English Instructions) ILL1456-A

User manual AG-WT10. Indoor unit air/air heat pump UHB GB LEK

Owners Manual. HTC621W 7-Day Programmable Thermostat 3600W. HTC625W 7-Day Programmable Thermostat 4000W

Transcription:

baby, cold i s t outside Spectrolink Comfort Controller Home Owner's Manual Heating 2006 Come home to ECOST R

SERVICE: 1300 650 644 For all your Braemar warranty and service needs. Or Contact your local Braemar direct dealer. SALES: 1300 650 141 For all your sales enquiries Seeley International Pty Ltd has a policy of continuous product development and therefore reserves the right to make changes to these specifications without notice. Whilst every care has been taken to assure accuracy of the data compiled in the document, Seeley International Pty Ltd does not assume any liability for errors and/or omissions. Braemar is a registered trademark of Braemar Industries Pty Ltd. Seeley International Pty Ltd ACN 23 054 687 035 Albury Manufacturing 77 North Street Albury, NSW 2640 www.seeley.com.au Manufacturers and Designers of Technically Advanced Quality Heating and Cooling Products 623528 / d Jan 06

IMPORTANT Record Model, Model No. & Serial No. of the heater here. LABEL Model, Model No. & Serial No. Date of Installation: / / Installer: Phone No: SERVICE Before calling for service have you: 1. Checked through the trouble shooting guide. (page 16) 2. Noted the Model,Model No. & Serial No. of the heater (if they are not recorded above, the numbers are located on the end of the heater) 3. Spoken to your Braemar Dealer / Installer. FOR SERVICE CALL: 1 300 650 644

Index T opic Page General 1 Setting the Time & Day 2 Turning the Heater On 3 The Spectrolink Comfort Controller 4 Button Functions 5 Display Functions 6-9 Special Features 10-11 Stored Auto Program 12 Changing the Auto Program 13-15 Trouble Shooting 16 Designed and manufactured in Australia to exacting standards.

General This Manual details the operation and set-up of the Braemar Comfort Controller when used to operate Braemar 3 Star, 4 Star and 5 Star Gas Ducted Heaters. Detail is provided for Comfort Controller operation of the Breezair, Braemar and Coolair range of Evaporative Airconditioners. The Spectrolink Comfort Controller will also operate Add-On Refrigeration systems.! DO NOT Operate this appliance before reading the instruction booklet. DO NOT Place articles on or against this Appliance. DO NOT Use or Store flammable materials near this Appliance. DO NOT Operate with panels, covers or guards removed from this Appliance. DO NOT Spray aerosols in the vicinity of this Appliance while it is in operation. TO BE INSTALLED BY AN AUTHORISED PERSON ONLY DELIVERY CHECKS The customer or installer, upon delivery of the heater should ensure that the model number and gas type is as requested. A data label on the end of the heater details both the model number and gas type. Please check the heater and report any freight damage. 1

Setting / Adjusting Clock If the time on the Comfort Controller is incorrect and needs adjusting, simply Turn the Comfort Controller to OFF, Open the door and Press and hold the button for 3 seconds. Use the UP/DOWN buttons to set the TIME - Press Use the UP/DOWN buttons to set the DAY - Press. Clock Setting Complete. If the power is ON and the time has been set, go to the next page. If the power to the heater has been OFF you will need to set the time and day. 1. Turn on the power to the heater The display flashes and 12:00 pm. 2. Open the front door WED AC MODE COOL/VENT 3. Use the UP/DOWN buttons to set the time. Hold down button for rapid adjustment. 4. Press the button to set the current time The display shows and WED flashing. 5. Use the UP/DOWN buttons to set the day 6. Press the button to set the current day WED OFF 7. Close the door Clock setting is complete. 2

Turning ON the Heater Simply follow the steps below : 1. Ensure the gas and power at the heater is turned on. 2. Check that the Comfort Controller is in mode. (Open the door and press the AC MODE button). 3. With the Door Closed turn the Comfort Controller ON. THU Press the ON / OFF button. 4. The heater will restart in the mode of operation in which it was last turned off. 5. Manual Mode - Press UP button until the desired set temperature is displayed. The heater will continue to operate at this setting until switched off or switched to Auto mode. HOME WED MAN NOTE - With Door Open - Set Temperature Displayed With Door Closed - Room Temperature Displayed 6. Automatic Mode - In the heater will operate according to the programed settings. HOME WED ON 3

Spectrolink Comfort Controller Below is an explanation of the stages the display of the Comfort Controller will show during normal heater operation. 1. The Comfort Controller is OFF. When the heater is not in use the Comfort Controller displays as shown. The heater is OFF. OFF WED Press the ON / OFF button. WED SLEEP 2. The Comfort Controller is in standby Auto mode. The heater is waiting for the room temperature to fall below the set temperature. 3. Comfort Controller is calling for. Heater is in start up mode. ON & WAIT are flashing. ON WAIT WED 4. Heater has Lit (Gas Burning). Pre fan period. WAIT & Flame symbol flashing. 5. The Comfort Controller is ON. The Fan symbol & Speed appear. Normal operation ON WAIT WED WED ON ZONE 4

COOL/VENT Button Functions WITH DOOR CLOSED ON / OFF Button. Turns the Comfort Controller ON or OF F. Temporarily Increase Set Temperature. Home / Away Button. Press to switch between Home operation and Away operation. Temporarily Decrease Set Temperature. Reset Button If RE is shown on the display Open the door and press the RE button. Auto/ Manual Button Press to switch between Automatic and Manual heater control. Set Button Press to enter the Clock or Program setting mode. AC Mode Button Press to set Comfort Controller to control heater or cooler. WITH DOOR OPEN AC MODE 5 Up Button Press to make adjustments in setting mode. Down Button Press to make adjustments in setting mode. Fan Button * Press to override the set fan speed. Cool / Vent Button Press to turn PUMP on or off in Evap Cool mode Zone Buttons * Press to turn heating or refrigerated cooling to a Zone on or off. * 4 & 5 Star heaters only

Display Functions MAN ON COOL WAIT REDOOROFF MONTUEWEDTHUFRISATSUN ZONE 1 2 PUMP 3 4 HOME AWAY SLEEP FLAME. Shows mode is selected and gas is burning Full Flame - High Gas Small Flame - Low Gas SNOW FLAKE In EVAPORATIVE COOLING mode the PUMP is on. In REFRIGERATED COOLING mode COOLING is on. MAN MAN Man displayed when Comfort Controller is in Manual mode. Auto displayed when operating the Automatic program. TEMPERATURE Displays the room temperature with door closed. Displays programmed temperature with the door open. 6

Display Functions WAIT COOL RE MONTUEWEDTHUFRISATSUN WAIT In mode, WAIT and ON are displayed flashing at the start of a heating cycle. In COOL mode, WAIT is displayed flashing at the start of a cooling cycle. Heat is displayed when the heater is set for mode. COOL Cool is displayed when set for COOL mode. Displayed flashing together with another segment (ie. time) to indicate other function must be set. RE Is displayed flashing if a fault occurs. Press the RE button to restart the heater. DAYS of WEEK The current day is displayed. Day must be set by home owner. TIME The current time is displayed. Time must be set by home owner. 7

Display Functions AWAY AWAY Displayed when the Comfort Controller is in Auto or Manual Mode. In Auto, the time is typically between 8.30am and 5.00pm. In Manual the heater will run at the set temperature. HOME HOME Displayed when the Comfort Controller is in Auto or Manual Mode. In Auto, the time is typically between 5.00pm and 10.30pm. In Manual the heater will run at the set temperature. SLEEP SLEEP Displayed when the Comfort Controller is in Auto Mode. The time is typically between 10.30pm and 6.00am, and a temperature of 12-16 degrees programmed. Displayed when the Comfort Controller is in Auto Mode. In Auto, the time is typically between 6.00am and 8.30am, and a temperature of 18-22 degrees programmed. FAN SPEED In heat mode, fan symbol rotates and fan speed is displayed. In cool mode, fan symbol rotates. 8

Display Functions ZONE 1 2 3 4 ZONE The word ZONE and 1, 2, 3, 4 are displayed in Heat and Refrigerated Cooling mode when zones are present & set. A number displayed indicates the ZONE is active. Zones are not displayed unless set by the installer. Zones are only available on 4 & 5 Star heaters. BATTERY Battery symbol is displayed when the power supply to the heater is off. Comfort Controller will hold current settings for up to one hour, and retain program indefinitely DOOR DOOR DOOR is displayed flashing when the door is open for more than 30 seconds. Symbol will disappear after any button press. Heater will not turn off if door is open. SPANNER Displayed when heater requires attention from a Braemar Service technician ON ON is displayed when the Heater is ON ON will be flashing at heater start. Steady ON when gas is burning. Steady ON in cool. OFF OFF is displayed when the Heater is Off 9

Special Features Home / Away Function. Use the HOME / AWAY button when you have an unscheduled change to your daily routine. If you arrive home early from work and your heater is not yet operating, pressing the HOME / AWAY button will bring forward the next scheduled time period. Example: HOME period is set to change at 5:00pm, but you arrive home at 4:30pm. Pressing the HOME / AWAY button will bring forward the Home period settings. Example: AWAY period is set to change at 9:00am, but you leave home early at 8:00am. Pressing the HOME / AWAY button will bring forward the AWAY period settings. With the Comfort Controller in Manual mode, the heater will operate according to the Home or Away settings. Pressing the HOME / AWAY button while the heater is operating shifts the operation between the Home and Away settings. The default settings for HOME / AWAY are set during auto programming. 10

Overriding the Set Temperatures. Special Features When the Comfort Controller is in Auto mode, the temperature settings can be temporarily overridden by pressing the UP/DOWN buttons. At the next time period the temperature will revert to the programmed value. In Manual mode, when the set temperature is overridden, the new setting becomes the default temperature. Zoning Braemar 4 & 5 Star heaters can be zoned. Zoning allows you to heat individual areas of your home to meet your specific requirements. If your heating system has been installed with one zone, the display will show the word ZONE and "1". If more zones are installed, numbers corresponding to the zones will be displayed. Your heating system can have to 4 zones. TUE ZONE 1 2 3 4 11

Stored Auto Programs The table below lists all the default values in the Automatic Default Program. When you first power up the Comfort Controller, the default program will run with the values shown. Changes can be made to any times, temperatures, zones or fan speeds. Refer to the set program function detailed in this manual. If changes are made to the auto program record them here for future reference. Time Period Time ON Temp 0 C Setting Zone ON Fan ON AWAY HOME SLEEP Heat Cool Your Settings Heat Cool Your Settings Heat Cool Your Settings Heat Cool Your Settings 6:00 20 1-2-3-4 10 6:00 20 1-2-3-4 10 8:30 14 1-2-3-4 10 8:30 14 1-2-3-4 10 5:00 21 1-2-3-4 10 5:00 21 1-2-3-4 10 10:30 14 1-2-3-4 10 10:30 14 1-2-3-4 10 12

Changing Program The Comfort Controller has a built in program that can be used to operate the heater Automatically. The program will turn the heater ON and OFF a number of times a day, at different temperatures and allow different zones to be heated. The program can be changed to suit your own personal needs. The default values for the program are shown on page 12. To change the program the Comfort Controller must be in Standby Mode. Press the / COOL button for Heat or Cool program setting. / COOL TUE Press to enter program setting Press the UP / DOWN buttons to select the individual DAY or GROUP of DAYS you want to Program MON Press the button to accept the DAYS option you require. The Comfort Controller is now ready to have the. default Auto program changed to suit you requirements. Record your changes in the Table on page 12 You can exit the program changes at any time by simply pressing the RE button Any changes you have made will be saved in memory. 13

Changing Program The program has 4 separate time periods of, AWAY, HOME and SLEEP. Programming follows the sequence below. AWAY HOME SLEEP TIME TEMPERATURE ZONES FAN SPEED Note: If no Zones are fitted to the heating system, the zone setting step will not appear. Setting of the period is shown in detail below; AWAY, HOME and SLEEP follow the same routine. The display shows the default settings for the period. ( no Zones ) In the following example, Monday thru Friday are to be. MONTUEWEDTHUFRI After the DAYS have been set, the display shows and TIME flashing. Press the UP / DOWN buttons to change the TIME. Press the button to accept the new TIME. MONTUEWEDTHUFRI The period will commence at the TIME you have set. 14

Changing Program and TEMPERATURE are now flashing MONTUEWEDTHUFRI Press the UP/ DOWN buttons to change the TEMPERATURE. Press the button to accept the new TEMPERATURE During the period, your home will be heated to the TEMPERATURE you have set. If your heating system has no zones, zone setting will not appear. and ZONE are now flashing MONTUEWEDTHUFRI ZONE 1 2 The display shows a heating system with 2 zones Press a Zone button to turn OFF the heating to that Zone ZONE 2 Press the button to accept the zone heating and FAN are now flashing. MONTUEWEDTHUFRI ZONE 1 2 Press the UP / DOWN buttons to adjust the amount of heating to the Zones. Press the button to accept the new fan speed. Setting of the period is now complete AWAY, HOME and SLEEP can now be set following the procedure above 15

If you have difficulty operating your Heater check the trouble shooting guide before calling for service. Problem? RE flashing with a number displayed in-place of the time. Open the front door on the control, press the RE button. The heater should operate after about 20 seconds. RE If RE reappears, wait 10 minutes, press the RE button. The heater should now start. MAN / If heater fails to start contact your service agent. Problem? Home is not heating effectively. Check that there are enough outlets opened for the fan speed selected. Open more outlets or another Zone to correct the problem. Is the return air filter blocked? We recommend cleaning every fortnight. Check the program running on the Comfort Controller is correct. Is the Comfort Controller located in the common area as recommended. (refer to Installation Manual Part No.623467 for more information) Increase the temperature. Problem? Heater comes on at wrong time. Check the time AM or PM. Check the Heater is in mode (not cool). Check the temperature is correct. Check the programmed "ON" times. Problem? Spanner Displayed When the spanner is displayed, call a service agent to look at the heater Trouble Shooting MAINTENANCE SCHEDULE Periodic maintenance of the heater will ensure a long and satisfactory service life with the heater operating at optimum performance. Maintenance should be performed on a regular basis (start of each heating season) by an Authorised person trained in the service of Braemar Heaters. CLEAN FILTERS EVERY 2 WEEKS AND REPLACE ANNUALLY 16 WED WED ON ON

Spectrolink Comfort Controller Home Owner's Manual Cooling Come home to ECOST R

Index Topic Page General 1 Setting the Time 2 Turning On the Cooler 3 Button Functions 4 Cooler Operation 5 Timed Start and Stop 6 Drain Valve - Bleed System 7 Maintenance 8-9 Troubleshooting 10 Designed and manufactured in Australia to exacting standards.

General Congratulations on choosing a new Evaporative Cooler for your home. Your cooler is built from the highest quality materials and engineered to provide many years of economical, trouble free cooling. Please take a few minutes to read these instructions so you have a full understanding of how to operate your cooler. Your installer should demonstrate the features and procedures set out in these instructions. The installer should also provide you with a Model and Serial number which can be filled out below. EFFECTIVE COOLING To provide efficient cooling or ventilation the building must have sufficient exhaust openings to the outdoors in the form of doors, windows or other vents. To assist air circulation, open windows or doors that are furthest from the outlet vent in each room. In every room that has an outlet vent, provide an exhaust opening 2 to 2.5 times the vent size of the room. Where the design of the building prevents adequate exhaust, consideration should be given to the provision of mechanical extraction such as an exhaust fan. Model No. Serial No. 1

Setting / Adjusting Clock.1. Turn on the power to the cooler. The display shows and 12:00pm flashing. WED 2. Open the front door. AC MODE COOL/VENT 3. Use the UP/DOWN buttons to set the time. Hold down button for rapid adjustment. 4. Press the button to set the current time. The display shows and WED flashing. 5. Use the UP/DOWN buttons to select current day. 6. Press the button to set current day. WED 7. Close the door. Clock setting is complete. If you have set the TIME or DAY incorrectly, open the door and hold down the button to start again. OFF Adjusting the Time - Turn the Comfort Control OFF, open the door, press and hold the button for 3 seconds and go to Step 3 2

Turning ON the Cooler Simply follow the steps below:. 1. Ensure the water and power at the cooler is turned on. 2. Check that the Confort Control is in COOL mode. (Open the door and press the AC MODE button). COOL THU With the Door Closed turn the Comfort Control ON. Press the ON / OFF. 4. The cooler will restart in the mode of operation in which it was last turned off. 5. Manual Mode - Press the UP button until the desired fan speed is displayed. If the cooler has been off for more than 10 minutes,wait, and FAN speed will flash indicating filter pad pre-wet cycle (2 minutes). MAN COOLWAIT WED 6. Automatic Mode - In the cooler will operate according to the ambient temperature sensed by the Comfort Control. As the ambient temperature varies up and down the the Comfort Control will adjust the fan speed to suit. 3

Button Functions WITH DOOR CLOSED ON/OFF Button Turns the comfort control On or OFF. UP Button Decreases Fan speed in Manual. Decreases Cooling in Automatic. HOME/AWAY Button! Not used for Evaporative cooler operation. DOWN Button Decreases Fan. speed in Manual. Decreases Cooling in Automatic. RE Button! Not used for Evaporative cooler operation. / MANUAL Button Press to switch between Automatic and Manual cooler control. Button Press to enter the Clock or Auto Timer setting mode. AC MODE Button Press to set Comfort Control to Heater or Cooler operation. WITH DOOR OPEN UP Button Press to make adjustments in time setting mode. DOWN Button Press to make adjustments in time setting mode. COOL / VENT Press to turn Pump On and OFF. ZONE Buttons! Not used for Evaporative cooler control.. FAN Button! Not used for Evaporative cooler operation. 4

COOL/VENT Cooler Operation Automatic and Manual Mode - To switch between Automatic and Manual operation open the Comfort Controller door and Press the MAN/ button. The display will change to indicate the mode of operation. COOL WED MAN COOL WED AC MODE Automatic - In Automatic mode the Comfort Control will set the Pump function and Fan speed according to the ambient temperature sensed by the Comfort Control. As the ambient temperature increases or decreases the Comfort Control will adjust the Cooler accordingly. If the automatic setting is not cold enough or too cold the automatic level can be overridden. Press the UP or Down button to override the Automatic cooling level to your comfort level. Any changes to the automatic setting will revert to the default setting when the cooler is turned off and then restarted. Manual - In Manual mode the Fan speed and Pump operation are both controlled by the home owner. Press the UP or Down button to set the fan speed. By pressing the COOL/VENT button the home owner can choose between cooled air (pump on) or ventilation (pump off). Pump On Pump Off MAN MAN COOL WED COOL WED AC MODE COOL/VENT In manual mode the cooler will continue to operated in the selected options until changed or turned off. 5

COOL/VENT Timed Start and Stop A feature of the Comfort Control is the option for the home owner to program a start and stop time. 1. With the Comfort Control turned off open the door and press the button. AC MODE 2. Press the MAN/ button to select mode of operation. ( The last mode of operation will be displayed first). AC MODE COOL/VENT 3. If Auto is selected go to step 4*. For manual mode press the UP or DOWN button to select Fan speed and the COOL/VENT button for Cold Air or Ventilation. AC MODE COOL/VENT 4. To set the start time press and then the UP or Down button to set the ON time. 5. To set the stop time press and then the UP or DOWN button to set the OFF time. AC MODE COOL/VENT 7. The Start and Stop times will remain for each day until the stop button is pressed. *If Automatic is selected fan speed and pump operation will be determined by the ambient temperature sensed by the Comfort Control at time of starting. 6

Automatic Drain - Bleed System Automatic Drain - If an automatic drain valve system has been installed into your cooler, the cooler will automatically drain the water, if water salinity becomes too high or when the pre-set time period has expired. This ensures the water is always fresh and helps maintain your cooler in good condition to ensure optimum cooling performance. The drain will be activated by 1 of 4 conditions: 1. Water salinity is too high 2. Pre-set time period expires (can be adjusted by your installer). 3. If the cooler is turned off for a continuous 72 hours. 4. Manually by pressing the UP and Down buttons simultaneously with the Comfort Control off and door closed. The display will show "dr" to confirm the operation has activated. During a drain operation all buttons are in-operable and on restarting your cooler a delay will be experienced while the tank refills with fresh water. Bleed System - During operation the bleed system will drain a small amount of water from the cooler to ensure fresh water is continually added. The amount of bleed will depend on local conditions and will set by your installer. 7

Maintenance Draining water from your cooler at the end of the summer season is not required if your cooler is fitted with an automatic drain valve system. However it is a requirement to check the cooler, it's operation, the pump, drain valve, solenoid and fan motor after the first year and then every two (2) years as routine maintenance. If the bleed system is fitted then maintenance should be conducted before and after every summer season as outlined below. WARNING: Seeley International recommends that is carried out by an authorised service agent. Climbing onto the roof is hazardous and could result in personal injury or property damaged. Failure to carry out maintenance will affect your warranty coverage. End of Season Maintenance 1. Turn off power to cooler. 2. Turn off water to cooler. 3. Remove the pad frame assemblies - insert a flat screwdriver tip into the slot (A) and lever until disengagement occurs. Take hold of the pad frame and pull it towards you (B) until the internal side clips disengage. Pivot the pad frame outward and lift up (C). Take care not to damage the pad. Repeat for all pad frames. A B C 8

Maintenance 4. Turn off power switch inside the cooler A. 5. Check and clean the lid water channels B. A 6. If fitted, unclip and remove the bleed system. Allow water to drain, take care not to lose the o-ring C. VE PAD AD-FRAMES B C 7. Thoroughly clean the tank and pump filter, DO NOT replace the bleed system. 8. Refit the pad frames. Preseason Maintenance 1. Turn off power to the cooler. Caution : Do not run the cooler with the pad frames removed. 2. Remove the pad frames. 3. Ensure power switch in cooler is off. 4. Gently wash the pads to remove any dust build up during winter. If pads are poor condition, replace them. CAUTION : Do not damage the pads with high pressure water spray. 5. If removed replace bleed system and ensure the o-ring is fitted. 6. Turn on power switch in cooler. 7. Turn on water, power, refit pad frames and run the cooler. 9

Trouble Shooting If you have difficulty operating your Cooler or consider that the cooler requires service check the trouble shooting guide before calling the service agent. Problem? Unpleasant Odour. Odour from new pads - Allow time to condition by running the cooler. Problem? Inadequate Cooling. Dry Pads - Check water flow to pads. - Ensure water supply is turned on. Insufficient exhaust openings - Ensure sufficient openings for conditioned air. Excessive ambient humidity - On days during summer when the ambient humidity is high, the cooler will not cool as effectively as on dry days. Problem? Wall Control Flashes " " An operational fault has been - Ensure the water and power supply detected. has been turned on. Check that the cooler drain pipe is not blocked. Turn off wall control and record the number displayed on the screen. Call a service agent quote the displayed number and the cooler serial number shown on page 1. 10