Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Similar documents
Wiring Instructions (01-09)

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

TS93 EMR WITH SMOKE DETECTOR

Installation Instructions

7200 Series. Electromechanical Closer/Holder Releasing Devices

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

DH400 Air Duct Smoke Detector

INSTALLATION AND MAINTENANCE

DH500ACDC Intelligent Air Duct Smoke Detector Housing

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

4100U City and Relay Cards Installation Instructions

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

E-PDD Duct Smoke Detector Installation Sheet

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

DH100ACDCI Ionization Air Duct Smoke Detector

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

1400 Direct Wire Ionization Smoke Detector

Duct smoke housings, 4-wire D341/D341P and D342/D342P

DH100ACDCI Ionization Air Duct Smoke Detector

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Instructions

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Addressable Detectors & Bases

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

RELEASE DEVICE CONTROLS

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

MODEL B2 INSTALLATION MANUAL

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

An ASSA ABLOY Group brand Series. Electromechanical Closer-Holder Releasing Device

ISIMET Series Shop Controller

TECHNICAL DATA OBSOLETE

MANUAL RESET ALARM RELEASE

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

DH500 Intelligent Air Duct Smoke Detector Housing

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

CommStat 4 Controller

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Analog Room Pressure Monitor RPC Series

FX-PDD Duct Smoke Detector Installation Sheet

Model 17A00 Expansion Enclosure

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ISIMET Utility Controller

Duct smoke housing, 2-wire D340/D340P

DH100LP Air Duct Smoke Detector with Extended Air Speed Range

2408/2900. Fire Guard

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

Series. Access Power Controllers. Installation Guide

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

IDP-Zone-6 Six Zone Interface Module

2409/2900. Fire Guard

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Installation Guide for models:

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Installation Guide for models:

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Electric Release Panel Wiring Tips

Conventional Releasing Control Panel

PO Box 827 Hawley, MN (218) Fax (218)

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Operator: Save these instructions for future use!

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Operation & Maintenance Manual

MANUAL RESET ALARM RELEASE

7251DH Intelligent Air Duct Smoke Detector

DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range

/9308 External Battery Chargers Installation Instructions

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

Transcription:

CAUTION Hinge Edge of Door Wiring Instructions Checkmate Series with Single Point Hold-Open Combination Door Closer-Holder and Releasing Device with or without Integral Smoke Detector INSTALLER: LEAVE INSTRUCTIONS WITH BUILDING OWNER TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT DAMAGE, DISCONNECT ALL POWER BEFORE BEGINNING. MAXIMUM WIRE SIZE IS AWG. ALL WIRING MUST COMPLY WITH APPLICABLE LOCAL ELECTRICAL CODES, ORDINANCES, AND REGULATIONS. CAUTION Checkmate Series Master Unit - - / - Support Unit - - / - Single Doors Checkmate Series Use one - or - Master Unit each door or one - or - Support unit each door Pairs of Doors Checkmate Series Use one - or - Master Unit and one - or - Support Unit for each door leaf (VDC -/- Support Unit must be used with -/- Master Unit) - Master Unit shown VDC - Support Unit shown VDC - Support Unit shown Hinge Edge of Door Hinge Edge of Door - Master Unit shown. Failure to install or adjust properly may result in injury or damage.. Disconnect all power before beginning installation to prevent electrical shock and equipment damage. CAUTION: REQUIREMENT:. All wiring must comply with applicable local electrical codes, ordinances, and regulations.. Maximum wire size is AWG.. These units are not to be used in limited open area applications. Power input to unit must be of the same voltage as that listed on the product label: VDC for systems where the power input to both the integral smoke detector and the door holder solenoid is supplied from the same circuit (see Pages and thru of these instructions). Copyright 00, 0 Yale Security Inc., an Group company. All rights reserved. 0--00-0 (0-)

Unit Examples: Checkmate Series: Smoke Detector Opening for Surface Wiring Red LED / Reset Switch Test Switch 0VAC - / - Master Unit shown Opening for Concealed Wiring Test Switch 0VAC -/- Support Unit shown WARNING: Life safety devices require correct positioning and appropriate selection for the required task. It is the responsibility of the purchaser to select appropriate hardware and provide professional installation. It is the responsibility of the purchaser to insure that NFPA and other applicable fire codes are met. Door release devices function properly only if the door is free to close and is installed correctly. Smoke detectors will not work without power. AC or DC powered smoke detectors will not work if the power supply is cut off for any reason. These fire protection devices require correct wiring to function. Devices wired incorrectly may be damaged and therefore not covered under warranty. All high voltage wiring should be undertaken by a qualified professional licensed electrician. It is the responsibility of the purchaser to insure that installation meets all applicable local and national electrical codes. A detector may not detect a fire developing on another level of a building. For this reason, detectors should be located on every level of the building. Smoke detectors will not sense fires which start where smoke does not reach the detectors. Smoke from fires in chimneys, in walls, on roofs, or on the other side of a closed door may not reach the smoke detector and activate it. Smoke detectors cannot last forever. Smoke detectors contain electronic parts. Even though detectors are made to last over 0 years, any of these parts could fail at any time. Therefore, test your smoke detector system per NFPA Chapter 0 at least semiannually. Clean and take care of your smoke detectors regularly. Refer to Page of these instructions for Smoke Detector Cleaning and Testing. Taking care if the fire detection system you have installed will maintain the reliability of the system. Smoke detectors have sensing limitations. Smoke detectors used in high air velocity conditions may fail to alarm due to dilution of smoke densities created by such frequent and rapid air exchanges. Additionally, high air velocity environments may create increased dust contamination, demanding more frequent maintenance. Copyright 00, 0 Yale Security Inc., an Group company. All rights reserved. 0--00-0 (0-)

Smoke Detector Terminal Inputs and Outputs V input power is applied to terminals and from the circuit board. The red LED flashes every seconds. Terminals and provide a normally open (alarm) contact. This contact closes when smoke is detected. The red LED illuminates continuously. Terminals and provide a normally closed supervisory (trouble) contact. This contact opens when power is lost to the detector circuitry. The red LED stops flashing and does not illuminate. Terminals and, if used, provide rectified, unfiltered VDC power to an additional door holder solenoid. In an alarm condition, power is removed and the door closes. Terminals and, if used, provide rectified, unfiltered VDC power to auxiliary devices when the detector alarms. Terminal 0 is VDC Positive output. It is continuous, rectified, unfiltered VDC power used for remote detector interconnect applications. Terminals and provide interconnections to other detectors (see diagram on Page ). Up to five smoke detectors may be interconnected. When a single detector alarms, terminal goes high and all interconnected smoke detectors will release their doors. The unit that initiated the alarm will have its LED on. The LED on the other interconnected units will flash as normal. Refer to Interconnection Wiring Diagram for connections. CONNECTION LIST FUNCTION TERMINAL VDC input, Alarm Contacts, Latch Latch Aux Aux Interconnect Interconnect SOLENOID Trouble contacts, +VDC output (unfiltered) 0 NOTE: Terminals,, and are same point 0 LED / Reset Detector Specifications: Type: Photo-Electric Smoke Detector complies with UL and UL standards. Power Requirements: VDC +/- 0%. Normal Sensitivity:. +/-.0% / FT. Contact Ratings: Alarm and / or accessories (Resistive Load):.0 Amps Max @ VDC 0. Amps Max @ 0VAC Trouble Contact (Resistive Load): 0. Amps Max @ VDC VAC VDC 0 VAC Max / Min Voltage Current - Detector. VAC Max. VAC Min. VDC Max. VDC Min VAC Max 0 VAC Min 0.0 A Standby 0.0 A Alarm 0.0 A Standby 0.0 A Alarm 0.0 A Standby 0.0 A Alarm Copyright 00, 0 Yale Security Inc., an Group company. All rights reserved. 0--00-0 (0-)

V AC/DC INPUT CIRCUIT BOARD (shown with -pin jumper for non-detectored units) Fuse (V / /A) V AC/DC POWER INPUT Support Unit Single Station Wiring Diagram (VAC/DC Input) TEST SWITCH VAC/DC Board -PIN JUMPER SOLENOID CONNECTION -PIN JUMPER -Pin Jumper 0V AC INPUT CIRCUIT BOARD Fuse (V / /A) (shown with Wiring Harness detectored units) TEST SWITCH -PIN JUMPER 0V AC POWER INPUT Support Unit Single Station Wiring Diagram (0VAC Input) 0VAC Board WIRING HARNESS SEE PAGES - FOR ADDITIONAL WIRING OPTIONS SOLENOID CONNECTION -Pin Jumper SHO * SOL SHO * SOL * Replaced By -Pin Jumper * Replaced By -Pin Jumper Mastert Unit Single Station Wiring Diagram (VAC/DC Input) VAC/DC Board SHO * SOL 0 Smoke Detector Master Unit Single Station Wiring Diagram (0VAC Input) 0VAC Board SHO * SOL Smoke Detector 0 * Replaced By -Pin Jumper * Replaced By -Pin Jumper All wiring diagrams are shown with circuits energized in stand by mode. Once alarmed, detector remains in alarm until reset by turning the reset switch on the detector. Refer to ANSI NFPA for recommended smoke detector applications. Environmental limits: 00 F( C); % relative humidity; not for use where high concentrations of corrosive vapors exist. Do not install where air velocity exceeds 0 ft. per minute. Copyright 00, 0 Yale Security Inc., an Group company. All rights reserved. 0--00-0 (0-)

Copyright 00, 0 Yale Security Inc., an Group company. All rights reserved. Slot for screwdriver to remove cover RP Test Point RP Test Point Checking Procedures: Turn the power to the unit On. Red LED light should illuminate at second intervals. Open the door to the hold open point. The door should hold open. Manually pull door out of hold open and release. The door should close. Open the door to the hold open position. Press the Test / Reset Switch button on the power supply board. Door should close. Press the Test / Reset Switch button again. Open the door to the hold open position. Inducing smoke into the smoke detector chamber assembly will bring the unit into alarm. The red LED will be continuously illuminated and the door will close. After clearing the smoke chamber, reset the unit as described below. Resetting Instructions: Remote Reset: Cycle main power by turning the facility main power supply OFF then ON. NOTE: If there are other units connected to the same power supply, those doors will close. They will have to be reopened returning them to the hold open position. Local Reset: Insert a small flat head screwdriver through the cover and into the slotted light tube on the smoke detector as shown. Turn screwdriver slightly (about / turn) clockwise until hitting stop and hold for seconds until the Red LED turns OFF. WARNING: Do not force past the stop. Doing so may damage the smoke detector. Once the detector is reset and the smoke has cleared, the detector s Red LED should flash once every seconds. The door(s) should hold open now. Maintenance of Smoke Detectors: It is recommended to clean smoke detectors at least every six months. The frequency of cleaning will depend upon local ambient conditions. The smoke detector in this door closer-holder has been enhanced with a feature that detects when a smoke-sensing chamber requires cleaning due to dirt and dust. The need for cleaning is indicated by the flashing of the Red LED once per second. Normal Supervisory Operation - Red LED flashes once every seconds. Dirty Chamber needs cleaning - Red LED flashes once every second. Smoke Detection - Red LED is continuously illuminated. To clean the smoke detector assembly, follow these instructions: (NOTE: Before servicing the system, notify the proper authorities that the smoke detector system is undergoing maintenance and will be temporarily out of service. Disable the zone undergoing maintenance to prevent unwanted alarms.) Remove detector cover and screen assembly using a standard screwdriver. Turn the screwdriver in the cover slot to loosen the cover and carefully rock the cover back and forth until it snaps out of place. See slot location below. Inspect chamber for particles and dust. Vacuum the screen, cover, and photo chamber. Then use clean, compressed air to loosen and blow out any remaining debris. Before reassembling the detector, be sure all parts are free of dust and debris. Replace cover and screen, aligning cover snaps. Press cover onto chamber until it snaps into place. Measure and record the test voltage at test points RP and RP (see below). If the smoke detector is operating normally and was cleaned effectively, the test voltage will be greater than.0vdc and less than.vdc. The test voltage will increase with dust accumulation in the smoke sensing chamber. A difference in test voltages over time will provide and indication of dust accumulation. Enable the system and inform proper authorities that system is operational. Cover and Screen Chamber 0--00-0 (0-)

MASTER WIRING DIAGRAM FOR -WIRE (CLASS A) SYSTEM WITH ALARM PANEL MONITORING The alarm circuit monitors if smoke is detected The detector trouble circuit monitors if power is lost to the detector. VDC Output Board VDC @ 0.A Max. P P V AC/DC or 0V AC Input (MPS0 or equiv.) 0 VDC Alarm Alarm Panel EOL Res Trouble VDC Output V DC @ 0.A Max. Board P P V AC/DC or 0V AC Input (MPS0 or equiv.) 0 VDC V DC @ 0.A Max. VDC Output Board P P V AC/DC or 0V AC Input (MPS0 or equiv.) 0 VDC Notes: End of Line (EOL) resistor determined and supplied by others. Terminal numbers shown correspond to position numbers of terminal strips on detector. Additional units may be added as required based on this schematic. See electrical data sheet. Do not overload circuits. All wiring connections use standard wiring practice conforming to local wiring codes. Copyright 00, 0 Yale Security Inc., an Group company. All rights reserved. 0--00-0 (0-)

MASTER WIRING DIAGRAM FOR -WIRE (CLASS B) SYSTEM WITH ALARM PANEL MONITORING The alarm circuit and trouble circuit monitor if smoke is detected VDC Output VDC @ 0.A Max. Board P P V AC/DC or 0V AC Input (MPS0 or equiv.) 0 VDC UL Listed Fire Alarm Panel Alarm & Trouble To Terminal 0 & On Additional Units or To EOL Resister on Last Unit VDC @ 0.A Max. VDC Output Board P P V AC/DC or 0V AC Input (MPS0 or equiv.) 0 VDC Notes: End of Line (EOL) resistor determined and supplied by others. Terminal numbers shown correspond to position numbers of terminal strips on detector. Additional units may be added as required based on this schematic. See electrical data sheet. Do not overload circuits. All wiring connections use standard wiring practice conforming to local wiring codes. Copyright 00, 0 Yale Security Inc., an Group company. All rights reserved. 0--00-0 (0-)

Wiring Diagram for Master to Slave / Companion To Companion Unit - v ONLY (-, -) Master Unit - 0v or v Input (-, -) Field Wiring Provided by Others Wire Nut or Splice Connector (Provided) To 0 Board Detector Board Connector (Red -Pin) Connector (White - & -Pin) (Factory Wired) Copyright 00, 0 Yale Security Inc., an Group company. All rights reserved. 000 Highway East Monroe, NC Tel: (00)--0 www.rixson.com 0--00-0 (0-)