Spark Holland introduces

Similar documents
300 series HPLC autosamplers

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

Online SPE-UHPLC-MS. CHRONOS for Control & System Integration. Flexible autosampler for sample preparation. Superior UHPLC system for analysis

Agilent 1290 Infinity II Vialsampler Data Sheet

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Systems. Visit us at

Customised HPLC Systems for Highest Performance

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

EC 160 CO 2. Incubator

Evaporators, Sealers and other Equipment

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

The KingFisher Family

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

CALIDUS tm the Modular micro Gas Chromatograph

Tool-free LC connections for HPLC, UHPLC and nano LC systems

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

How Important is Performance to your SPE Method Development?

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Agilent 1290 Infinity II Online SPE Solution

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

MultiPurpose Sampler MPS robotic series

SCION 436-GC. Dimensions and Weights

Integrated Process Solutions. Series 49. Thermal Management System

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D*

Methods of solid phase extraction. Methods of solid phase extraction

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

DENTAL TABLE TOP STERILIZER SERIES S CLASS MODEL : MO-MOST-T24/45/80.

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

Bionics Instrument. Alarm Handling. Gas Alarm Systems

HydroSpeed plate washer for 96- and 384-well formats

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

STRIKE GUARD DELIVERS:

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

Agilent InfinityLab Online SPE Solution

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

Use of Automation to Achieve

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Thermo Scientific Dionex SolEx SPE Cartridges

detectors UltiMate 3000 Variable Wavelength Detectors

Sensitive Determination of Microcystins from Environmental Waters Using On-Line SPE

Waters 2767 Sample Manager, Injector, and Collector Installation and Maintenance Guide

Nexera-i Specifications Prominence-i Specifications

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

HISTORY OF VARIAN CAPILLARY INJECTORS

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Automated Fractionation System that Increases Recovery and Optimize Precision of Solid Phase Extraction Methodology

Explore the future of flow measurement. SITRANS FC430 - the most compact NTEP approved Coriolis flow meter. Process Instrumentation

FREESTYLE QUATTRO ACCECLEAN ELUVAC GPC COLUMNS IMMUNOAFFINITY COLUMNS SAMPLE SAMPLE PREPARATION PRODUCTS PREP

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

HPLC Column Ovens and Temperature Controllers

Soxtec 200 series Solvent Extraction Solution

HydroSpeed plate washer for 96- and 384-well formats

Solvent Evaporation. Fast, Reliable and Affordable

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

On Line SPE LC/MS/MS Applications

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

Heidolph Vacuum System. Heidolph Vacuum System. Vacuum pumps. Vacuum accessories. ROTAVAC valve control. VAC control automatic. ROTAVAC vario control

Order by phone Order on-line Order by fax Website

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

FIXED GAS ANALYZER (FGA)

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

New Designs and Formats in Solid-Phase Extraction Sample Preparation

ELISA NIMBUS. Automated ELISA Processing System

Sample Preparation Solid Phase Extraction Disks Cartridges. Horizon Technology, Inc. Salem, NH USA

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

SmartPrep Automated SPE Cartridge Extractor II Module

VHP ARD BIODECONTAMINATION SYSTEM

G-TECTA TM. Portable Gas Detection Instruments

1,000W (DAP-60K: 100 W per digestion vessel)

FREESTYLE always ready

Purge and Trap Troubleshooting Made Easy?

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

MICROPLATE EVAPORATORS

Parker icount Oil Sampler (IOS)

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

Chromatography. Research Supplies. 2014/2015 Catalog

Rotavapor R-220 Pro Technical data sheet

Turbimax CUE21 / CUE22

B/R 9600 Packed Column Distillation Systems. Fractional Distillation for the Laboratory and Industry

Environmental Chambers

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

Agilent 1260 Infinity Multi-Detector Suite

Varian 356-LC RI Detector

Transcription:

BETTER SAMPLE CARE Spark Holland introduces ACE Absolutely unique: on-line SPE with Automated Cartridge Exchange

Spark Holland introduces ACE Absolutely unique: on-line SPE with Automated Cartridge Exchange ACE Absolutely unique: on-line SPE with Automated Cartridge Exchange

Combining the best of the on-line and off-line SPE worlds Off-line SPE (Solid Phase Extraction) provides cartridge refreshment for every sample, avoiding the risk of retention change and carryover. However, limited pressure resistance prohibits the use of small sorbent particles. Off-line elution of the sample requires collection and reformatting (often including evaporation and reconstitution) into autosampler vials or wells. And finally injection into the LC system! It also requires at least one manual transfer of collected samples from the SPE robot to the LC system. On-line SPE (or column switching, or 2D LC) permits use of small sorbent particles for efficient SPE plus elution of the sample directly into the LC system by the mobile phase. Maximum SPE efficiency plus maximum SPE-LC automation. But column switching does not allow frequent automated refreshment of the SPE column or cartridge. The Spark ACE TM eliminates this shortcoming. It selects a fresh cartridge as often as you want and seals it against the pressure of your LC system for on-line elution. ACE TM combines the flexibility of off-line SPE with the performance and automation of on-line SPE. Dual cartridge clamps and extra valves for unlimited SPE capability ACE TM can be equipped with an extra cartridge clamp and as many as three extra high pressure switching valves. Such a fully loaded system enables sophisticated SPE applications like parallel SPE for high throughput or 2D SPE for enhanced clean-up. For high-throughput applications, extended cartridge tray capacity is provided with the tray feeder, which brings the total SPE cartridge capacity to 960! TASPE TM Temperature Assisted SPE ACE TM provides the option to use temperature as a parameter to enhance and control your SPE method! This unique and patented feature helps to reduce organic content in SPE solvents, enables on-cartridge protein precipitation, provides extra options to optimize selectivity and clean up, etc. It also helps to maintain constant temperature for SPE, improving reproducibility of the assay. And it is such an easy parameter to use! Just program the temperature for any of the solvent delivery steps in the SPE procedure. Find out what temperature control can do for your application. - Disposable SPE cartridges sealed up to 300 bar - Single use or re-use of SPE cartridge your choice - Wide range of SPE chemistries - Standard two trays of 96 cartridges each - Optional tray feeder for 10 trays - TASPE TM Temperature controlled SPE - Dual clamp option for parallel SPE and 2D-SPE

SPE Cartridges: optimized dimensions and unlimited sorbent range ACE TM on-line SPE cartridges have been designed to combine the option of single use with highly efficient extraction. With 10 mm length and 2 or 1 mm internal diameter, the cartridge contains only 5-25 mg of sorbent. Particle size is typically under 10 µm for regular sorbents, providing chromatography-like separation efficiency. While off-line SPE is typically an on-off mechanism with less than 10 theoretical plates, plate numbers up to 250 are not unusual for our C18 cartridges. This allows for small elution volumes and heart-cut type of SPE, washing away both early and late eluting matrix components from the SPE cartridge. All common sorbent chemistries are available in our cartridge format. And if you need your own material packed into our cartridges: ask us about the options! We can even provide immunoaffinity chemistries on pressure stable supports with low nonspecific binding. Tailor the on-line SPE system to your application ACE TM is the heart of an on-line SPE system, but it cannot provide on-line SPE on its own. An autosampler is required to introduce the untreated samples into the system and an additional solvent pump is needed to load the samples on the SPE cartridges and deliver solvents for conditioning, and washing of the SPE cartridge. Spark provides a high pressure solvent dispenser (HPD TM ), designed especially for accurate flow and volume based delivery of SPE solvents up to 4300 psi. It can select multiple solvents and can even mix solvents for automated SPE method development. See the Spark Holland HPD TM brochure for more information. SparkLink TM PC control software After configuring a system, you need full control of every component to obtain maximum flexibility in assay development. Our SparkLink TM software provides just that. That does not mean that you can t use any third party instruments for your on-line SPE system; you may select a different autosampler or SPE pump. Just be aware that it will provide limited control options as compared to Spark instruments. A special Easy Access control level allows for rapid start-up of method development with pre-programmed system parameters. No worry OEM partnering Spark is recognized for its OEM service and capabilities and for ACE TM we make no exception! We are open to discuss any customization of hard- and software. We provide a range of communication interfaces and comprehensive software integration support. Test us! Reassuring reliability Spark has more than 27 years of experience in development and innovation of sample handling technology. The robustness of our instruments has been proven in more than 25,000 autosamplers and over 1,000 systems for on-line SPE: reassuring numbers if you demand a reliable partner in HPLC.

Specifications Automated Cartridge Exchange (ACE TM ): Cartridge capacity Cartridge capacity ACE TM with tray feeder Cartridge tray 2 cartridge trays of 96 SPE cartridges each 10 cartridge trays of 96 SPE cartridges each 8 x 12 well plate format (96 x 128 mm) 192 SPE cartridges 960 SPE cartridges with built-in RF-transponder for: cartridge ID and usage cartridge type, batch number, production number (unique), expiry date Cartridge clamp Leak-tight up to max. 300 bar ~4300 psi High-pressure valves Valco 6 port valve (C2-2006) Removable with bayonet fitting. One valve is standard, three additional valves are optional (SSM). Cycle time Parallel mode: cartridge exchange 13 seconds Communication Inputs: 4 programmable TTL conditional digital inputs Outputs: 4 programmable contact closures max. 28 V 1A). PC interface RS 232C is standard Control software SparkLink TM 4.0 PC control Power requirements 115/230 Vac -20%/+15%. 50/60 Hz, max. 200 VA Dimensions 300x470x240 mm (WxDxH) Size top cover area: 300x280 mm (WxD) Weight ACE TM 14 kg ACE TM -dual 300x640x360 mm (WxDxH) ACE TM -dual 19 kg (2 cartridge clamps and 2 valves) ACE TM -dual with tray feeder 24 kg Working environment 5-40 C, 20-80% RH Storage temperature: -25-60 C Option TASPE TM Temperature Assisted Solid Phase Extraction Temperature range: 20 C - 80 C

Specifications Compliances Safety Installation category Pollution degree Quality CE; CSA (UL) EN61010-1 Machine safety: 2006/42/EC EMC requirements: 2004/108/EC Low voltage safety: 2006/95/EC II (according to IEC-1010) 2 (according IEC-664) ISO 9001 certified

Specifications SPE Cartridge Cartridge dimensions 10 x 2 mm (l x ID) - 8 mm OD Option: 10 x 1 mm (l x ID). Internal volume 31 µl Option: 8 µl Maximum pressure 300 bar ~4300 psi Sieve pore size 1 µm Wetted materials PVDF (body) and stainless steel sieve SPE sorbents HySphere TM BondElute TM range (Trademark of Varian SPP) OASIS TM (Trademark of Waters) Custom packing and proprietary range of sorbents on special order. Bio-affinity sorbents: contact us to discuss options.

Ordering information ACE TM versions ACE ACE 2 x ISS ACE dual 2 x ISS ACE dual with tray feeder, 2 x ISS ACE with TASPE TM ACE 2 x ISS with TASPE TM ACE dual 2 x ISS with TASPE TM ACE dual with tray feeder, 2 x ISS with TASPE TM SP725.300 SP725.320 SP725.520 SP725.523 SP725.301 SP725.321 SP725.521 SP725.524 For more information: Spark Holland B.V. P.O. box 388 7800 AJ Emmen The Netherlands P. +31 591 631 700 F. +31 591 630 035 E. info@sparkholland.com www.sparkholland.com Head Office: P. de Keyserstraat 8 7825 VE Emmen The Netherlands BETTER SAMPLE CARE 0051.990.10 Specifications are subject to change