Blower-YEFB-020-3R-1maxVel

SIGMA PRISMA LOW BODY CONCEALED

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

UCS UCS/M UCS/H UCS900

FAN COIL UNITS LASER / LOW BODY / CONCEALED

PRODUCTS GUIDE INTEGRATED COMFORT SYSTEMS

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

NEW GREEN TECHNOLOGY

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Conditioning your ambient, maximising your comfort.

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

QTS SELECTION TECHNICAL BOOKLET

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

YFCN Fan Coil Unit centrifugal fan

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

FAN COIL UNITS. The optimal solution for limited space

Conditioning your ambient, maximising your comfort.

QZB "Standard" comfort fan coil

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Energy. The Energy ducted units have been designed. Heat Recovery Unit

Fan Coil Range HYDRONIC TERMINALS

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

The Sabiana. of Fan Coil

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

next p dw next p dw rcgroupairconditioning

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Fan coils with Inverter Brushless motor (EC) Universal and floor installation FCZI_U

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

EHH SERIES DRAW THROUGH FAN COILS CFM

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

Cassette type FCU TFP-KM4. Water terminal units. available configurations. accessories. Indoor installation Capacity from 1.8 to 12.

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

next evo cw next evo cw rcgroupairconditioning

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

PRODUCT GUIDE

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

Air Conditioning Carisma CRS High Pressure Fan Coil Units.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

CASSETTE UNIT. Comfort Circle

NEXT DL NEXT DL. rcgroupairconditioning

UniTrane Ductable Units D-line and B-Line

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

EC Motor Fan Coil Units. IMD-Y Series l/s

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

TopVent Design Handbook

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

CLIMACIAT AIR COMPACT

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

QZHW Fan Coil Unit. Key features. Specifications

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

technical data Fan coil unit FWB small duct unit

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

NEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Transcription:

EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy every request of heating and cooling applications in big environments, where ducted air distribution is requested. They are suitable for horizontal installation. These are units for COOLING and HEATING applications; they are fed with cold and hot water and used according to their relevant performance features. EBH and EDS units are components of cooling and/or heating systems; consequently, they are without any safety devices on the water circuit. These units have been designed for temperatures up to 100 C. When you want to connect this high pressure unit to a condensing unit in COOLING mode, it must be ordered with a direct expansion coil (optional upon request, except for sizes 060-070). EDS HIGH PRESSURE UNIT EBH HIGH PRESSURE UNIT

DUCTED UNITS EBH EDS EBH features 6 SIZES for horizontal ducted installation, 2 and 4 pipe system. HIGH PRESSURE: they are designed for ducted installation with external static pressure up to 300 Pa. STRUCTURE is realized in galvanized metal sheet, insulated internally; in order to facilitate all maintenance operations, the structure is divided in three separate and independent sections (condensate tray, fan deck, air filter). HEAT EXCHANGERS can have 2, 3 or 4 rows, made by copper pipes and aluminium fin pack; 5-row coils are available for sizes 060 and 070. Up to size 050 all coils are provided with air vent valves. For sizes 060 and 070, the air vent valve is supplied only with the valve kit (optional). REVERSIBLE WATER CONNECTIONS: these high-pressure units can be ordered with right (standard) or left water connections; it is possible to reverse the water connections on site, if necessary. FAN DECK is composed by a 3 speed motor and two centrifugal galvanized steel scrolls. All motors are Class F and IP44 protected; they are provided with a permanently connected capacitor and thermal protection of the windings with automatic reset. CONDENSATE TRAY is realized in galvanized steel with water discharge pipes on both sides. AIR FILTER consists of a washable polyester acrylic fibre, pleated and protected by a metal frame. The filter section can be easily removed for cleaning and maintenance. Filtration class G3. ELECTRIC PANEL is composed by a terminal board with screw terminals contained in an ABS plastic box (IP30). A supporting relay is supplied as standard starting from size 040. 4 BRACKETS are supplied along with the unit, to fix it to the ceiling. EBH UNIT WITH AIR SUPPLY PLENUM

EBH EDS EDS features 9 SIZES for horizontal ducted installation, 2 pipe system. HIGH PRESSURE: they are designed for ducted installation with external static pressure up to 300 Pa. DOUBLE SKIN STRUCTURE is composed by insulated 25 mm thick panels, colour RAL9002, and aluminium supporting frame. HEAT EXCHANGERS can have 2, 3 or 4 rows, made by copper pipes and aluminium fin pack; 5-row coils are available for sizes 060 and 070. Up to size 050 all coils are provided with air vent valves. For sizes 060 and 070 of the EBH model, the air vent valve is supplied only with the valve kit (optional). NOT REVERSIBLE WATER CONNECTIONS: EDS units can be ordered with right (standard) or left water connections. FAN DECK is composed by a 3 speed motor and two centrifugal galvanized steel scrolls. All motors are Class F and IP44 protected; they are provided with a permanently connected capacitor and thermal protection of the windings with automatic reset. CONDENSATE TRAY is realized in galvanized steel with water discharge pipe located on the water connections side. AIR FILTER consists of a washable polyester acrylic fibre, pleated and protected by a metal frame. The filter section can be easily removed for cleaning and maintenance. Filtration class G3. ELECTRIC PANEL is composed by a terminal board with screw terminals contained in a high protection box (IP55). A supporting relay is supplied as standard starting from size 040. 4 BRACKETS are supplied along with the unit, to fix it to the ceiling. EDS HIGH PRESSURE UNIT

HIGH PRESSURE UNIT EDS The big advantages of the EURAPO high pressure units are: quiet operation reliability excellent quality/price ratio high coefficient of performance sturdiness and solid construction accurate choice of each single component environmentally friendly sandwich panels (EDS model) high protection electric panel (IP55), available also on EBH models class F fan motors with high protection grade (IP44) easy installation and maintenance operations EBH WITH VALVE

EBH EDS Accessories for EBH units: VALVE KIT 3 way 4-port regulating valves with ON/OFF or modulating actuators, provided with copper connection kit and insulation shell (supplied loose). CONDENSATE PUMP with 6 m maximum head. CONDENSATE TRAY in stainless steel. SPECIAL FILTER made of washable polyester acrylic fibre, filtration class F5. ADDITIONAL COILS for hot water with 2 or 3 rows, for units to be installed in 4-pipe systems. DISTRICT COOLING COILS: Heat exchangers with a reduced number of circuits, suitable for applications where the water thermal head is about 9 C. ELECTRIC HEATER it is an additional section to be mounted on the air outlet, provided with all necessary safety thermostats. The heating capacity is different from size to size, up to 9 kw. AIR DELIVERY/AIR INTAKE PLENUM with several frontal spigots. RAL 9001 PAINTING with oven dried epoxy powders. All RAL colours are available. REGULATING SYSTEMS: the whole range of EURAPO regulators is available: fan speed selectors, electro-mechanical controllers, electronic controllers with microprocessor, digital regulators with a centralized supervision system communicating via Bus based on standard protocols. For more information, please either refer to the specific EURAPO technical literature or visit the official web site www.eurapo.it. ADDITIONAL COILS ELECTRIC HEATER VALVE KIT CONDENSATE PUMP AIR DELIVERY/AIR INTAKE PLENUM RAL 9001 PAINTING

Accessories for EDS units: VALVE KIT 3 way 4-port regulating valves with ON/OFF or modulating actuators, provided with copper connection kit. CONDENSATE PUMP with 6 m maximum head. SPECIAL FILTER made of washable polyester acrylic fibre, filtration class F5. DISTRICT COOLING COILS: Heat exchangers with a reduced number of circuits, suitable for applications where the water thermal head is about 9 C. ELECTRIC HEATER it is an additional section to be mounted on the air outlet, provided with all necessary safety thermostats. The heating capacity is different from size to size, up to 9 kw. AIR DELIVERY/AIR INTAKE PLENUM with several frontal spigots. REGULATING SYSTEMS: the whole range of EURAPO regulators is available: fan speed selectors, electro-mechanical controllers, electronic controllers with microprocessor, digital regulators with a centralized supervision system communicating via Bus based on standard protocols. For more information, please either refer to the specific EURAPO technical literature or visit the official web site www.eurapo.it. VALVE KIT SPECIAL FILTER ELECTRIC HEATER AIR DELIVERY/AIR INTAKE PLENUM DISPLAY CONSOLE ANALOGUE PLUS CONSOLE

EBH EDS Technical data EBH UNIT: STANDARD TECHNICAL DATA 50 Pa EXTERNAL STATIC PRESSURE-ASYNCHRONOUS (1) Air temperature: 27 C d.b., 48% rel. humidity - Water temperature: 7/12 C (2) Air temperature: 20 C, 50% rel. humidity - Water inlet temperature: 50 C - Water flow value as cooling, according to EUROVENT standards and UNI ENV 1397 Norm. (3) Pressure level in open field at 1,5 m distance and reverberating time of 0,3 s. (4) Performances are out of scope Eurovent FCP. In order to select the EBH or EDS ducted fancoil with District Cooling coils, please use the EURAPO software for selection. Models EBH EBH EBH EBH EBH EBH 020 030 040 050 060 070 (4) MAX External static pressure [Pa] 125 175 200 250 300 300 Total cooling capacity [kw] (1) Heating capacity [kw] (2) Air volume [m 3 /h] Sound pressure level [db(a)] (3) Absorbed current [A] Power input [W] Technical data EDS UNIT: MAX 6,95 9,49 12,17 14,34 23,69 29,07 MED 5,90 8,23 10,78 12,77 21,78 27,23 MIN 4,30 7,11 9,18 11,59 17,23 25,00 MAX 8,68 12,70 16,70 21,26 31,56 41,71 MED 7,33 10,70 14,10 18,65 28,60 38,93 MIN 5,40 9,20 12,20 16,70 21,06 35,33 MAX 1156 2092 2662 3189 4116 5552 MED 922 1558 2083 2769 3610 5075 MIN 617 1329 1621 2398 2575 4521 MAX 49 52 54 56 61 64 MED 43 45 47 52 58 62 MIN 33 42 42 49 50 60 MAX 0,75 1,55 2,08 2,84 4,47 7,64 MED 0,52 1,21 1,68 2,47 4,03 7,30 MIN 0,33 1,11 1,30 2,25 2,85 6,81 MAX 171 338 467 620 956 1701 MED 120 256 368 534 872 1601 MIN 72 227 276 474 600 1453 N rows (standard) 4 4 4 4 4 4 Fan deck features Class F (155 C) - IP44 Power supply [V-ph-Hz] 230-1-50 STANDARD TECHNICAL DATA 50 Pa EXTERNAL STATIC PRESSURE-ASYNCHRONOUS Models EDS EDS EDS EDS EDS EDS EDS EDS EDS 004 006 008 020 030 040 050 060 070 MAX External static pressure [Pa] 50 50 50 125 175 200 250 300 300 Total cooling capacity [kw] (1) Heating capacity [kw] (2) Air volume [m3/h] Sound pressure level [db(a)] (3) Absorbed current [A] Power input [W] MAX 2,42 3,26 4,50 6,94 8,79 10,00 11,62 21,02 24,68 MED 1,69 2,56 3,86 5,21 7,25 8,76 10,83 18,69 22,53 MIN - 1,87 2,88 2,94 6,04 7,39 9,59 14,60 20,65 MAX 3,18 4,26 5,50 9,15 12,35 14,72 17,74 29,43 36,91 MED 2,27 3,38 4,87 6,87 9,88 12,34 17,10 25,94 33,75 MIN - 2,41 3,84 3,88 8,21 10,70 15,08 18,91 30,54 MAX 401 596 794 1396 2347 2652 3356 4335 5496 MED 272 428 658 943 1600 2039 2809 3644 4867 MIN - 270 472 480 1297 1575 2357 2529 4303 MAX 43 39 43 60 55 53 57 62 64 MED 33 36 39 41 46 47 53 58 62 MIN - 21 30 27 41 41 49 49 59 MAX 0,26 0,35 0,42 0,79 1,65 1,79 2,90 4,79 7,85 MED 0,20 0,27 0,35 0,51 1,17 1,32 2,41 4,03 7,40 MIN - 0,20 0,28 0,30 1,03 1,03 2,05 2,72 6,69 MAX 59 79 97 183 358 406 623 1037 1784 MED 46 61 81 117 246 292 521 874 1610 MIN - 46 64 69 212 225 436 573 1411 N rows (standard) 4 4 4 4 4 4 4 4 4 Fan deck features Class F (155 C) - IP44 Power supply [V-ph-Hz] 230-1-50

Dimensions [mm] EBH UNIT Model A B C D E F G H I Connections Spigots 020 030 990 902 408 927 366 634 963 307 404 G 1/2 F 3 040 050 1240 902 408 1177 366 634 1213 300 404 G 1/2 F 4 060 070 1635 1160 518 1572 476 892 1608 311 514 G 1 M 5 350 G A B I C 134 F 134 E 21 H 91,5 D 78,2 200 31,5 OPTIONAL PLENUM Dimensions [mm] EDS UNIT Model A B C D E F G H I Connections 004 882 742 924 390 799 250 855 306 798 G 3/4 M 006 008 1007 867 1049 390 924 250 855 306 798 G 3/4 M 020 030 1132 992 1174 440 1049 300 855 357 798 G 3/4 M 040 050 1382 1242 1424 440 1299 300 855 357 798 G 3/4 M 060 070 1777 1637 1819 550 1694 410 1030 467 978 G 1 M

EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous modulation of the air flow, constantly related to the concrete need of energy in the room. EST technology is composed by a brushless motor combined to a dedicated electronic device (inverter), managed by specific regulators developed by EURAPO. In comparison to the traditional units equipped with asynchronous three-speed-motors, the fan coil and cassette units with brushless motors can obtain a considerable energy saving, by reducing the power consumption up to 70%. 80% 70% W speed 1 60% speed 2 50% 40% 30% speed 3 speed 4 speed 5 speed 6 20% 10% 0% m 3 /h m 3 /h 6 5 speed 4 speed 3 speed 2 speed 1 Asynchronous fan coil absorption (W) Energy saving with EST fancoil EST fan coil absorption EST (W) Thanks to the step-less modulation of the fan speeds it is possible to accurately regulate the air volume in a very precise way, in strict relation to the real need of air conditioning in the room. Oscillations in the temperature and relative humidity are reduced at lowest level: a guarantee for the highest comfort in the room. The possibility to reach very low air volumes makes the units extremely quiet at the lowest motor revolutions.est technology is designed in particular for offices, hospitals, nursing homes and hotels. It is available for the EURAPO range of fan coil units, cassette units and ducted units.

Technical data HIGH PRESSURE UNIT EBH STANDARD TECHNICAL DATA 50 Pa EXTERNAL STATIC PRESSURE-EST Models ESTEBH ESTEBH ESTEBH ESTEBH ESTEBH 020 030 040 050 060 MAX External static pressure [Pa] 125 175 200 250 300 Total cooling capacity [kw] (1) 9 V 7,93 9,50 12,35 16,00 24,51 Heating capacity [kw] (2) 9 V 10,96 13,52 16,94 23,94 36,88 Air volume [m3/h] 9 V 1430 1981 2712 3772 4306 Sound pressure level [db(a)] (3) 9 V 53 51 56 56 69 Absorbed current [A] 9 V 1,38 1,04 1,32 2,74 3,37 Power input [W] 9 V 185 232 296 617 762 N rows (standard) 4 4 4 4 4 Fan deck features Class F (155 C) - IP44 Power supply [V-ph-Hz] 230-1-50 (1) Air temperature: 27 C d.b., 48% rel. humidity - Water temperature: 7/12 C (2) Air temperature: 20 C, 50% rel. humidity Water inlet temperature: 50 C (3) Pressure level in open field at 1,5 m distance and reverberating time of 0,3 s. In order to select the EBH or EDS ducted fancoil with District Cooling coils, please use the EURAPO software for selection.. Technical data HIGH PRESSURE UNIT EDS STANDARD TECHNICAL DATA 50 Pa EXTERNAL STATIC PRESSURE-EST Models ESTEDS ESTEDS ESTEDS ESTEDS ESTEDS ESTEDS ESTEDS 004 006 020 030 040 050 060 MAX External static pressure MAX [Pa] 50 50 125 175 200 250 300 Total cooling capacity [kw] (1) 9 V 3,45 5,25 7,49 8,77 9,86 12,21 22,47 Air volume [m 3 /h] 9 V 624 1040 1554 2191 2611 3354 4769 Sound pressure level [db(a)] (3) 9 V 41 40 51 53 54 57 65 Absorbed current [A] 9 V 0,53 0,95 1,38 1,24 1,23 2,18 3,83 Power input [W] 9 V 60 114 186 279 275 488 870 N rows (standard) 4 4 4 4 4 4 4 Fan deck features Classe F (155 C) - IP44 Power supply [V-ph-Hz] 230-1-50 ESTEDS unit is available for cooling operation only.

Eurapo Srl Via A. Malignani, 12 33170 Pordenone - Italy T +39 0434 572552 F +39 0434 28667 info@eurapo.it www.eurapo.it District COOLING by EURAPO www.eurovent-certification.com www.certiflash.com As programs and technologies are always improving, description, data and drawings must be intended as merely indicative and can be modified without any notice. 6DC0302 - EN1600