FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Similar documents
OPERATION AND INSTALLATION MANUAL

Application, Installation, Operation & Maintenance Manual

The EN54 Part 2 and 4 Fire System

Installation, Operating and Maintenance Manual

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

Reliably Advanced Extinguishing Control

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Precept Marine Control Panel Application Guide

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The EN54 Part 2 & 4 Fire System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Reliably Advanced Extinguishing Control

Intelligent Security & Fire Ltd

Excel-EN Conventional Fire Control Panel

General Routing Interface

System 800 Addressable Fire Detection & Alarm System

Product Data Sheet. Remote Terminals. Features:

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Conventional & Twin-wire Fire System

GAS SUPRESSION CONTROL PANEL:

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

An introduction to... Sigma

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

The EN54 Part 2, 4 and 13 Fire System

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

ALARMLINE ANALOGUE Linear Heat Detection System

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Doc. No.: OMPII.DOC Rev. 2 Written By: Raj Patel Checked By: AJC Approved By: JBJ Date: 03/05/05

Door Release Power Supply

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Intelligent Security & Fire Ltd

Operation and Maintenance Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Control Panel Engineering and Commissioning Instructions

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

CARBON DIOXIDE CO 2 Industrial fire suppression systems

User Operation Manual

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Conventional Leaflets

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

FireBeta A-XT UL Approved Extinguishant Control Panel

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

Intelligent addressable fire alarm control panel

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

SALES SUPPORT DOCUMENT

EXTINGUISHING AGENT RELEASE MODULE

Installation and user manual for the BiWire / Conventional Repeater Panel

SOUNDER CONTROL MODULE SCM-AS4

5000 INSTALLATION GUIDE

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Conventional Fire Control Panel

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Fire Alarm Control Panel Installation, Commissioning & Operation MAN

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

INPUT / OUTPUT MINI MODULES

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Specification/ Data Sheet

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

SECURIT 700L PLUS ENGINEERING MANUAL

Technical Data Sheet

Conventional Fire Control Panel with Extinguishant Control Unit. Operation and Maintenance Manual SIGMA-2-M3-ECU SIGMA-4-M3-ECU SIGMA-8-M3-ECU

FEC403EN Installation Manual

EP203. Manual. Approved Document No. DFU Rev 2

ZXSe Range Data Sheet

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

EP203. Manual. Approved Document No. DFU Rev 4

FEC400 Series. Installation Manual

5000 Series Rack Panels

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Interface Modules for SENTRI

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Surveyor Envoy-MINI 4

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Conventional Fire Detection

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

RE 25AR. Agent Release Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual

Transcription:

F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas of detection and 2 areas extinguishing Robust in construction, with precise information and simple operation Designed to comply with BS EN54 Parts 2 and 4 and BS7273 Part 1 Microprocessor based system providing flexibility and reliability 10 levels of programming via membrane Integral power supply Supports remote status indicators The ECP range of control panels is microprocessor based to provide the reliability and flexibility required to meet today s stringent requirements. The control panels have conventional detection zones and output circuit(s) with extinguishing release capability. Designed, manufactured and tested under the stringent requirements of BS EN ISO9001, the ECP complements Kidde Fire Protection extensive range of fire extinguishing systems. Ten levels of user definable programming provide complete flexibility of operation, ensuring that the ECP will more than adequately meet the demands of both simple and complex systems. The ECP is housed in a high quality, mild steel enclosure designed to ensure ease of installation, accommodating all external cables without the need for drilling. All versions incorporate a membrane fascia as the user interface; this provides precise information using LED indications and user control switches. The panels have three access levels to restrict operation to the appropriate authority level (user, operator and engineering level). The ECP design incorporates various safety features including: Critical circuit faults inhibit agent release Earth fault detection One man test mode Hold circuits Abort circuits The integral power supply is rated at 3.1 amps and has temperature compensated charging circuitry to ensure that the standby batteries maintain their correct charging voltage.

2 General Mains supply input 220/240v AC 50 Hz +10% - 15% 1st Stage VFCO 30v dc rated at 1 amp (1 per release area) 2nd Stage VFCO 30v dc rated at 1 amp (1 per release area) Actuator circuit 1 A 24v dc (1 per release area) 1st Stage open collector 45 ma at 24v dc (1 per release area) 2nd Stage open collector 45 ma at 24v dc (1 per release area) Fail safe fault relay 30v dc rated at 1 A Beam reset facility 30v dc rated at 1 amp Common sounder 500 ma (1 per panel) 1st Stage sounder circuit(s) 500 ma (1 per release area) 2nd Stage sounder circuit(s) 500 ma (1 per release area) Quiescent Current (no devices) 77 ma 2+1, 84 ma 4+1, 93 ma 4+2 Alarm Current 250 ma 2+1, 260 ma 4+1, 300 ma 4+2 (no sounder load) Power supply capacity 3.1 Amp Detection compatability Apollo and Hochiki detectors with standard bases, 32 detectors per zone Battery capacity 2 x 7 A/Hr sealed lead acid cells Weight 8 kg excluding batteries 438mm w x 128mm d x 298mm h Ingress protection IP31 (BS/EN60529) Monitored Circuits Detection zone A Detection zone B Detection zone C * Detection zone D * Hold per release area Abort per release area per release area Discharged per release area Auto/manual key switch per release area Low Pressure per release area Common Sounder 1st Stage Sounder per release area 2nd Stage Sounder per release area * 4+1 and 4+2 panels only External Controls Auto/Manual keyswitch (per extinguishing area) (per extinguishing area) Silence Buzzer Reset Evacuate Programme Silence Alarms Isolate Test Spare Internal Controls (on pcb) SW1 Common sounders constant/pulsed SW1 Access level 4 enabled/disabled SW2 Hardware reset SW3 Processor reset LK1 Internal/external power supply select R6 Battery charger output adjustment Unmonitored Circuits Disabled input 1st Stage open collector output per release area 2nd Stage open collector output per release area Access Level 2 input Beam reset output Failsafe Fault output Internal Indications (on pcb) Hold Abort Low Pressure Discharge Actuator Disable

3 SYSTEM CONFIGURATION Typical system configuration for a 4+2 ECP AREA 1 COMMON AREA 2 2nd STAGE SOUNDER 1st STAGE SOUNDER HOLD ABORT ZONE B ZONE A COMMON SOUNDERS COMMON FAULT BEAM RESET STATUS INDICATORS ACCESS ZONE A ZONE B HOLD ABORT 1st STAGE SOUNDER 2nd STAGE SOUNDER ECP AUTO/MANUAL KEY SWITCH MANUAL RELEASE 4 + 2 AUTO/MANUAL KEY SWITCH MANUAL RELEASE 1st STAGE VFCO 1st STAGE VFCO 2nd STAGE VFCO NOZZLES 2nd STAGE VFCO NOZZLES EXTINGUISHANT CYLINDERS EXTINGUISHANT CYLINDERS

4 HOLD AND ABORT SWITCHES The Hold and Abort Switches are housed in light grey RAL 7035 GW plastic enclosures incorporating a smooth anti static, self adhesive identification membrane and removeable lid, secured by 4 captive screws. The units are rated IP56 in accordance with IEC 529:1989. The rear of the enclosure has four 4 mm diameter fixing centres accessed by removing the plastic knockouts. The units can be semi flush mounted, in a 104mm x 104mm x 70mm recess. INTERMEDIATE HOLD/ABORT SWITCH HOLD SWITCH The Hold Switch will delay the release of extinguishant whilst held in the on position. When released, the hold switch will reset the extinguishing system to alarm stage 1. The switch should be located within the risk area. Audible and visual confirmation of the operation of the switch will be indicated on the ECP. If the switch is operated in any other condition than alarm stage 2, a fault condition will be initiated for out of sequence operation. ABORT SWITCH Operation of the abort switch will cancel release of extinguishant, which can then only be discharged by resetting the panel or performing a mechanical discharge. The abort switch should be located within the risk area. Audible and visual confirmation of the operation of the switch will be indicated on the ECP. If the switch is operated in any other condition than alarm stage 2, a fault condition will be initiated for out of sequence operation. 100 ALARM RESISTOR LAST HOLD/ABORT SWITCH 100 ALARM RESISTOR 3K6 END OF LINE RESISTOR Hold Switch 35 mm red, mushroom type, configured as a non latching switch with two sets of single pole single throw contacts rated 5A @ 30 vdc. The screw type terminals can accept conductors up to 4 mm 2. The contacts house a 100 ohm alarm resistor which is introduced into the circuit when the switch is operated. 108 (w) x 108 (h) x 85 (d) mm to the top of the switch. (59 mm deep to the top of the enclosure) Hold Switch Kidde Fire Protection Part No 53836-K179 Abort Switch 40 mm red, mushroom type switch, configured as a latching switch, twist to release, with two sets of single pole single throw contacts, rated 5A @ 30 vdc. The terminals are screw type and can accept conductors up to 4 mm 2. The contacts house a 100 ohm alarm resistor which is introduced into the circuit when the switch is operated. 108 (w) x 108 (h) x 85 (d) mm to the top of the switch, (59 mm to the top of the enclosure) Abort Switch Kidde Fire Protection Part No 53836-K180

5 STATUS INDICATORS The status indicators are housed in mild steel enclosures, painted ash grey. External dimensions are 123 x 123 x 46mm. (143 x 143mm for flush mounted units). Each unit comprises a back box, detachable lid with membrane fascia and internal pcb. There are 3 types of status indicators: Type 1: Indication only Part No 53836 K178/01 Type 2: LED indication and auto/manual keyswitch Part No 53836 K178/02 Type 3: LED indication, manual release and auto/manual keyswitch Part No 53836 K178/03 A maximum of six status indicator units can be connected to an ECP over a maximum distance of 1km. Connection Terminals Receive RS 485 communications from ECP and out to next Status Indicator 0v/24v dc Power supply from external source Input and OutputTerminals Auto/Manual keyswitch Input and Output Terminals LED indications RED Discharged YELLOW Auto/Manual mode GREEN Manual only Open collector outputs are also provided, for internal use only (0v dc at 60mA). All outputs operate in constant mode. Open Collector Outputs 1 Discharged 2 1st Stage 3 2nd Stage 4 Disabled 5 Abort 6 Hold 7 Auto/Manual 8 Manual only E9832-327 01/02 Kidde Fire Protection UK Sales Office Head Office Thame Park Road, Thame, Oxfordshire OX9 3RT, UK Tel: +44 (0)1844 265003. Fax: +44 (0)1844 256156 E-mail: info@kfp.co.uk Web: www.kfp.co.uk UK Sales Office Unit 12, Atley Way, North Nelson Industrial Estate, Cramlington, Northumberland NE23 1WA UK Tel: +44 (0)1670 713455. Fax: +44 (0)1670 735553 International Offices Dubai: Tel: +971 4 337 2498. Fax: +971 4 337 5088 Hong Kong: Tel: +852 2195 3688. Fax: +852 2743 7477 Singapore: Tel: +65 424 7979. Fax: +65 424 7978 Australia: Tel: +61 3 9765 3850. Fax: +61 3 9765 3800