Report No CRT-414

Similar documents
TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Variable Speed Convertible Air Handler 5 Ton

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

16 SEER TWO-STAGE AIR CONDITIONERS

36,000-62,000 BTUH Nominal Capacity

Variable Speed Convertible Air Handler 4 Ton

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Commercial High-Efficiency Condensing Units

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh


CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Models 566D 569C,576B with 524A 6to30Tons

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Variable Speed Convertible Air Handler 2 1/2 Ton

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

INSTALLATION INSTRUCTIONS

ELECTRICAL QUANTITY WEIGHT (LB)

Vertical Upflow Horizontal Left Air Handlers

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Cooling/Heat Pump Convertible Air Handlers

13 SEER CONDENSING UNITS

Cooling/Heat Pump Convertible Air Handlers

TECHNICAL SPECIFICATIONS

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

PACKAGE AIR CONDITIONER

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Modular Multi-position Air Handler

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

R4H4. Product Specifications

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Corp L2 Revised

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

TECHNICAL SPECIFICATIONS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

MACH N-407 Heat Pump Air-Cooled Chiller

PAJ3. Product Specifications

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Product Data. Convertible Air Handlers 1 1/2 5Ton

N4A6. Product Specifications

4YCC3048A3096A /3/ /

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Cooling/Heat Pump Convertible Air Handlers

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp.

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

13 SEER CONDENSING UNITS & AIR HANDLERS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

N4H4. Product Specifications

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

C22FC Bulletin # October 1993 Supersedes May 1993

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

City of Duluth Festival Center 04/25

Transcription:

Unit Nameplate Manufacturer: Available upon request form XDX Model No.YSC120E3RHAOWJX Serial No. 807103096L Volts: 208/230 Hertz: 60 Phase: 3 Refrigerant Type: R-410A Indoor Fan Motor Manufacturer: G. E. Model No.: 5K49VN4673X Volts: 208/230/460 Amps: Phase: 3 Hertz: 60 HP: 3 RPM: 1725 Compressor #1 Manufacture: Available upon request form XDX Model: SPA044B3BPA Serial No.: 08AF0435N Volts: 200/230 Amps: 13.5 Phase: 3 Hertz: 60 Compressor #2 Manufacture: Available upon request form XDX Model: SPA057A3BPA Serial No.: 07KF4243N Volts: 200/230 Amps: 13.5 Phase: 3 Hertz: 60 Outdoor Fan Motor Manufacture: Emerson Model No.: K55HXKGF-9531 Serial No.: N/A Volts: 208/230/460 Amps: Phase: 3 Hertz: 60/50 RPM: HP: N/A

Description of Coils Indoor Outdoor Number of Coils 1 2 Fin Material Aluminum Aluminum Tubing Material Copper Copper Style Staggered Staggered Type of Fins Lanced Lanced Number of Fins per Inch 16 16 Diameter of tubing (O.D.), in. 3/8 3/8 Number of Tubes per Row 40 42 Center-to-Center Distance Between 1 x 1 1 x 1 Tubes in inches* Number of Rows Deep 5 3 Coil Height, in.* 40 40 Coil Length, in.* 46 60 Face Area (Total), sq. ft.* 12.78 33.3 * Accuracy to these values is not implied; as shown, they are translated from lineal fractional dimensions measured, and only for comparison with decimal equivalents. - 3 -

Results of s s Run # 1 Airflow, Air Temperature, Capacity Unit with no modifications 75% IEER 50% IEER 65º Barometer 28.9920 28.9615 28.9629 28.9680 Airflow, CFM 3,611 3,603 3,626 3,627 Airflow, SCFM 3,498 3,495 3,462 3,465 Indoor Static Pressure, In. W.G. 1.11 1.10 1.10 1.10 Outdoor Air Inlet, dry-bulb F 94.74 81.39 68.08 65.07 Indoor Air Inlet, dry-bulb F 79.69 79.64 79.65 79.67 Indoor Air Inlet, wet-bulb F 67.25 67.23 67.19 67.23 Indoor Air Outlet, dry-bulb F 60.41 59.31 66.52 66.80 Indoor Air Outlet, wet-bulb F 58.17 57.27 61.01 60.97 Total Indoor Sensible Capacity, Btu/hr 74,407 78,378 50,213 49,272 Total Net Cooling Indoor Side, Btu/hr 104,786 113,990 72,800 73,780 Voltage, Volts Phase A-B 208.4 208.6 209.0 208.9 Phase B-C 209.2 209.3 209.7 209.8 Phase A-C 209.8 209.9 210.3 210.3 Amperage, Amps Phase A 37.8 34.1 21.9 21.6 Phase B 34.4 30.8 18.6 18.3 Phase C 35.3 31.6 19.9 19.6 Power Total Power Input, Watts (kw) 11.47 10.05 6.11 5.99 Energy Efficiency Ratio, (EER) 9.14 11.35 11.92 12.33 Pressures Compressor Suction A, Psig 147.2 144.7 140.3 139.0 Compressor Discharge A, Psig 418.8 349.5 286.1 274.7 Condenser Liquid A, Psig 371.0 303.6 242.4 230.2 Compressor Suction B, Psig 143.9 141.1 189.9 181.0 Compressor Discharge B, Psig 443.9 377.1 190.6 181.7 Condenser Liquid B, Psig 410.4 342.0 190.1 181.0-4 -

s Run # 1 Unit with no modifications 75% IEER 50% IEER 65º Temperatures Compressor Suction A, ºF 68.09 68.55 68.45 68.48 Compressor Discharge A, ºF 173.72 156.57 139.98 137.17 Condenser Liquid A, ºF 101.09 87.94 71.47 68.31 Compressor Sump A, ºF 105.61 99.06 90.85 89.63 Compressor Suction B, ºF 72.36 71.95 74.24 70.01 Compressor Discharge B, ºF 178.30 160.95 70.27 67.71 Condenser Liquid B, ºF 108.50 97.99 67.66 65.11 Compressor Sump B, ºF 104.51 96.96 82.86 77.48-5 -

s Run # 2 Airflow, Air Temperature, Capacity Unit with XDX and larger TXV s 75% IEER 50% IEER 65º Barometer 29.0256 29.019 29.0329 29.0491 Airflow, CFM 3,619 3,622 3,647 3,651 Airflow, SCFM 3,514 3,528 3,496 3,502 Indoor Static Pressure, In. W.G. 1.14 1.14 1.15 1.16 Outdoor Air Inlet, dry-bulb F 94.9 81.72 68.25 65.27 Indoor Air Inlet, dry-bulb F 76.66 79.66 79.67 79.66 Indoor Air Inlet, wet-bulb F 67.23 67.25 67.23 67.22 Indoor Air Outlet, dry-bulb F 59.80 58.50 66.05 66.27 Indoor Air Outlet, wet-bulb F 57.59 56.50 60.39 60.28 Total Indoor Sensible Capacity, Btu/hr 76,976 82,301 52,581 51,785 Total Net Cooling Indoor Side, Btu/hr 111,116 123,125 80,730 82,044 Voltage, Volts Phase A-B 208.2 208.5 208.9 208.9 Phase B-C 209.0 209.2 209.6 209.5 Phase A-C 209.5 209.7 210.1 210.1 Amperage, Amps Phase A 37.5 33.9 21.6 21.4 Phase B 33.9 30.4 18.3 18.0 Phase C 35.1 31.6 19.7 19.4 Power Total Power Input, Watts (kw) 11.32 9.97 5.99 5.88 Energy Efficiency Ratio, (EER) 9.82 12.35 13.48 13.96 Pressures Compressor Suction A, Psig 149.1 146.6 141.8 141.3 Compressor Discharge A, Psig 425.7 356.1 290.5 279.2 Condenser Liquid A, Psig 373.4 303.7 239.1 227.4 Compressor Suction B, Psig 146.2 142.7 191.6 183.1 Compressor Discharge B, Psig 450.8 386.8 192.4 183.8 Condenser Liquid B, Psig 407.4 345.9 191.1 183.1-6 -

s Run # 2 Unit with XDX and larger TXV s 75% IEER 50% IEER 65º Temperatures Compressor Suction A, ºF 62.47 58.72 55.28 54.93 Compressor Discharge A, ºF 166.73 144.89 125.62 122.2 Condenser Liquid A, ºF 101.67 89.07 72.90 70.05 Compressor Sump A, ºF 95.93 84.90 76.15 74.87 Compressor Suction B, ºF 53.37 52.73 67.81 65.09 Compressor Discharge B, ºF 152.52 142.49 68.14 66.05 Condenser Liquid B, ºF 111.40 99.62 68.01 65.02 Compressor Sump B, ºF 74.60 76.46 73.47 71.7-7 -

s Run # 3 Airflow, Air Temperature, Capacity Unit with out XDX and with larger TXV s 75% IEER 50% IEER 65º Barometer 28.5709 28.5968 28.6250 28.6216 Airflow, CFM 3,659 3,650 3,681 3,679 Airflow, SCFM 3,496 3,501 3,474 3,473 Indoor Static Pressure, In. W.G. 1.12 1.12 1.13 1.13 Outdoor Air Inlet, dry-bulb F 94.96 81.68 68.10 64.99 Indoor Air Inlet, dry-bulb F 79.83 79.82 79.77 79.77 Indoor Air Inlet, wet-bulb F 66.85 66.85 66.89 66.89 Indoor Air Outlet, dry-bulb F 60.08 58.76 66.64 66.60 Indoor Air Outlet, wet-bulb F 57.72 56.68 60.63 60.47 Total Indoor Sensible Capacity, Btu/hr 76,173 81,334 50,370 50,500 Total Net Cooling Indoor Side, Btu/hr 105,377 116,409 74,011 75,840 Voltage, Volts Phase A-B 207.8 207.8 208.2 208.1 Phase B-C 208.4 208.3 208.7 208.7 Phase A-C 208.9 208.9 209.3 209.3 Amperage, Amps Phase A 38.1 34.4 21.8 21.5 Phase B 34.7 31.0 18.5 18.1 Phase C 35.4 31.8 19.7 19.4 Power Total Power Input, Watts (kw) 11.52 10.14 6.03 5.91 Energy Efficiency Ratio, (EER) 9.14 11.48 12.27 12.83 Pressures Compressor Suction A, Psig 151.9 148.9 143.1 142.4 Compressor Discharge A, Psig 428.2 359.3 292.8 281.3 Condenser Liquid A, Psig 369.7 301.9 237.7 223.9 Compressor Suction B, Psig 145.1 142.1 187.4 181.2 Compressor Discharge B, Psig 460.9 395.0 192.3 182.1 Condenser Liquid B, Psig 422.6 355.8 191.6 182.0-8 -

s Run # 3 Unit with out XDX and with larger TXV s 75% IEER 50% IEER 65º Temperatures Compressor Suction A, ºF 59.05 57.60 53.77 53.47 Compressor Discharge A, ºF 161.95 142.32 123.29 119.79 Condenser Liquid A, ºF 99.43 87.27 72.05 69.01 Compressor Sump A, ºF 91.86 83.14 74.28 72.97 Compressor Suction B, ºF 54.33 53.81 68.70 66.45 Compressor Discharge B, ºF 161.36 145.62 68.25 65.22 Condenser Liquid B, ºF 111.64 99.80 68.17 65.60 Compressor Sump B, ºF 84.07 78.41 73.32 71.24-9 -

Summary Total Capacity Full Load 75% Load 50% Load 55º Standard OEM TXV 104,786 113,990 72,800 73,780 With XDX MystiCool & larger TXV 111,116 123,125 80,730 82,044 Utilizing just the larger TXV 105,377 116,409 74,011 75,840 Total EER Full Load 75% Load 50% Load 55º Standard OEM TXV 9.14 11.35 11.92 12.33 With XDX MystiCool & larger TXV 9.82 12.35 13.48 13.96 Utilizing just the larger TXV 9.14 11.48 12.27 12.83 Remarks In this specific test and specimen, the total power in each test segment was lower with XDX than without XDX ; the capacity was higher with XDX than without XDX ; and the total EER was when compared to the original OEM design operation was improved by 7.4%, 8.8%, 13.1%, and 13.2% through use of XDX technology. Notes: (1) The results contained in the report are for technical evaluation only and are applicable only to the specific test specimen referenced within the report. (2) The tests reported have not been performed at the request of the Air-Conditioning and Refrigeration Institute, and use of these findings by XDX Innovative Refrigeration. in any advertising or other literature shall state that the test is not part of the ARI Certification Program. Dates of s: April 22-28, 2008 by: Report Approved by: John Rowe Technician Gary Stout Technician Team Leader - 10 -