Two-Channel Gas Controller

Similar documents
Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Combustible Gas Detection and Control System

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Multi-Gas-Controller MGC2

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard 2-channel Gas Controller MGC-03

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

User Manual. PolyGard Single Point Controller SPC3-11XX. Single Point Gas Controller Serial Number _E_1007. May 2009

Danfoss gas detection units

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Warranty Registration

Danfoss gas detection units

User Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_.

Carbon Monoxide CO Transmitter ADT-X3-1110

Carbon Monoxide Transmitter

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Model D12-IR. Digital Gas Transmitter...

Gas Controller Module GC-06

User Manual. PolyGard Single Point Controller SPC Single Point Gas Controller for Combustible Gases Serial Number _E_1008.

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

Danfoss gas detection Controller unit

Inc Series Digital Gas Detector/Controller. Operation Manual

ALTAIR 5X Multigas Detector Product Specification

Macurco DVP-120 Detection and Ventilation Control Panel

GLD-30 Gas Leak Detector

Toxic Gas Detection. Model F12. Toxic Gas Detection

Danfoss gas detection unit Type GD Heavy Duty

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Analog Room Pressure Monitor RPC Series

Model D12. Digital Gas Transmitter

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

SIL 2. Ultima X Series Gas Monitors CERTIFIED

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

Controllers. Instruction Manual WARNING

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

CLEANROOM MONITOR CR3A Network - Installation Instructions

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Version Inc Series Digital Gas Detector/Controller. Operation Manual

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Instruction Manual WARNING

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

Product Manual SZ1145

Product Manual SZ1144

CN7232 Advanced Garage Ventilation Controller

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

Stand Alone DYNAGARD SP Operation Manual

Process & TeMPerATUre UniversAl input DigiTAl MeTers

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

INSTALLATION AND OPERATING INSTRUCTIONS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Universal Gas Detector

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

GAS PLUS ALARM SYSTEM

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

S5000 Gas Monitor. GMS5000.com

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

User Manual. PolyGard AT-3300 V3. Transmitter for Combustible Gases. Serial No. ET April 2009

Sensor unit MC2 with analog output for Freon gases and refrigerants

21-light Remote Annunciator. Owner s Manual

Process Alarm Module RTA 421

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Temperature Controllers

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

DTA. Motor thermistor relay. Benefits. Description

Pioneer-R16 Gas Monitor Operator s Manual

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

EXAMPLES OF HOW TO ORDER

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

incontrol Systems Inc. Flame and Gas Detection

EXAMPLES OF HOW TO ORDER

IGD.CO.UK

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

PureAire Combo O 2 / CO 2 Monitor

Air Check O 2 Deficiency Monitor 0-25%

APPLICATION DATA SHEET

OPERATION AND MAINTENANCE MANUAL CONTROLLER 8000 ENVIRONMENTAL MONITORING AND CONTROL SYSTEM INDUSTRIAL SCIENTIFIC

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Gas Detection System TOX ALARM DG2000-Garage

Beacon 110 Gas Monitor Operator s Manual

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Transcription:

Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously compares measured inputs to pre-defined alarm thresholds and activates internal switches/relays when thresholds are breached. Includes inputs for two external -0 ma analog sensor/transmitters, one binary input, two alarm relays, two open collector outputs and one analog output. Up to four thresholds can be defined for each input. Controller also includes a large, -line, -character LCD and four pushbuttons for an easy system configuration (with password protection) and continuous real-time measurement value display. Four faceplate LEDs indicate power, alarms, manual relay override and sensor fault conditions. Programmable service date alarm ensures reliable long-term operation. APPLICATION To detect and control levels of toxic and combustible gases in a wide variety of commercial and industrial applications; for example, carbon monoxide (CO) and nitrogen dioxide (NO) levels in parking structures, warehouses and repair shops, methane in boiler rooms, hydrogen in battery charging rooms, refrigerant leaks in chiller rooms, and more using INTEC AT-Series gas transmitters. Analog input channels can also measure/monitor any other environmental conditions (such as temperature, relative humidity, static pressure, etc.) using industry-standard -wire or -wire -0 ma transmitters. Setup options provide for selectable latching or non-latching alarms, time delays and threshold hysteresis to eliminate false trips and resets, as well as minimum relay on/off times to prevent harmful fan cycling. The controller can communicate with most building automation, DDC, PLC or analog control systems, either via serial Modbus communications (optional) or binary/analog output signals. PolyGard NRTL Performance Tested & Certified Conforms to STD UL 0 FEATURES Continuous monitoring and four-stage control Two () remote analog inputs, -0 ma, overload & short-circuit protected One () analog output, (0)-0 ma / (0)-0 VDC - Selectable for lowest, highest, or average of the two analog inputs One () digital input Two () relay outputs: - () SPDT, () SPST-NO/NC One () VDC switched output, 0 ma max. Audible Alarm Liquid Crystal Display (LCD) LED status indicators Keypad user interface Simple menu-driven programming Modular technology for easy installation & maintenance NEMA X (IP) enclosure Optional Modbus Comms. (replaces analog output)

Specifications subject to change without notice. USA 09 Page of SPECIFICATIONS Electric Power supply VAC/VDC, -0%/+% 0/0 Hz, reverse polarity protected Power consumption. VA (0. A) Type of Control General Stage level / setpoint Four-stage (S to S) control, assignable up to two () binary/ relay and VDC / 0 ma switched outputs, i.e. low-high stage for relay output and switched VDC at any stage for remote alarming Field adjustable over full range, four () stages (S to S) per analog input, assignable to current or mean (average) value - each stage level (S-S) Assignable to any relay - sensor fail-safe Assignable to any stage level - hysteresis/ switching differential Selectable for each sensor point Inputs/Outputs Gas / Input types - CO Carbon Monoxide - EX Explosive (%LEL) - NO Nitrogen Oxide - NO Nitrogen Dioxide - O Oxygen (low alarms) - O Oxygen (high alarms) - NH Ammonia - CO Carbon Dioxide - SO Sulfur Dioxide - HS Hydrogen Sulfide - CL Chlorine - ETO Ethyl Alcohol - VOC Vol. Organic Compounds - RXX Refrigerants - RXX Refrigerants - R Refrigerants - RA Refrigerants - R Refrigerants - TEM Temperature (low alarms) - TEM Temperature (high alarms) - RHY Relative Humidity - PCT Percent (low alarms) - PCT Percent (high alarms) Analog input () -0 ma, 00 Ω load, overload and short-circuit protected Analog reading Current and mean (average) value Digital input One (); for remote audio/visual alarm reset or relay override Relay outputs (R, R) () SPDT (R), and () SPST-NC w/ status LEDs or SPST-NO (R), jumper selectable Contact rating 0 VAC/VDC, 0. A, max. Time delay switching Selectable for make and break of each sensor point (SP to SP) 0 9,999 seconds Analog output One (), (0) 0 ma, load 00 Ω; (0) -0 VDC, load 0K Ω; jumper selectable; polarity protected, assignable to low, high or averaging of sensor inputs Modbus output (opt.) -wire; RTU protocol VDC switched output One () VDC, 0 ma max Alarm acknowledgment Menu-driven and system reset function for latched relays Audible Alarm 8 db (A) (@ 0. ft), 00 Hz User Interface Keypad type Refer to section User Interface & Controller Touch buttons Four () Status LEDs Four (), for system on, alarm-, alarm-, and sensor fault Digital display Liquid Crystal Display (LCD), two lines, characters per line - unit display Menu selectable, per sensor; ppm, %v/v, %LEL, F or %RH Environmental Permissible ambient - working temperature F to F (-0 C to 0 C) - storage temperature F to 8 F ( C to 0 C) - humidity to 9% RH, non-condensing - working pressure Atmospheric ± 0% Physical Enclosure - material Polycarbonate, UL 9 V, fire-retardant - conformity UL 0 standards - color Light gray - protection NEMA X (IP) - installation Wall (surface) mounted, or single gang electrical box Dimensions (H x W x D). x. x.9 in. (0 x 0 x mm) Cable entry holes for / in. conduit for wall (surface) mounting and hole on back side of base plate for single gang electrical box mounting Wire connection Terminal blocks, screw type for lead wire Wire size Min. AWG (0. mm ) Max. AWG (. mm ) Wire distance Max. loop resistance 0 Ω (= wire distance plus controller input resistance) Weight 0. lb (0. kg)

Specifications subject to change without notice. USA 09 Page of SPECIFICATIONS Approvals / Listings - unit rating NRTL Perf. Tested & Certified Conforms to STD ANSI/UL 0 CE VDI 0, C-No. 89 EMC-Compliance 00/08/EEC LVD //EEC - relays (R-R) UL Recognized, E CSA, C. No. 0, No. (File No. LR98) - enclosure UL Listed, E080 CSA Certified, E080 Warranty Two years material and workmanship OPTIONS Heater - temperature control 8 F ±. F ( C ± C) - ambient temperature -0 F/ C - humidity to 9% RH, non-condensing - working pressure Atmospheric - power consumption 0. A; 8 VA Modbus Communications Interface Serial RS-8; 900 Baud Protocol Modbus RTU ORDERING INFORMATION -0-XX US 0 M Output -0 ma Modbus 0 = Standard 0 Options None Heater 0 = Standard Example: - 0-00 US, configuration includes: Digital, -channel programmable gas controller with menu-driven keypad user interface, LCD & LEDs, VAC/VDC, 0/0 Hz NEMA X enclosure Output: () -0 ma, () relays, () open collector Input: () -0 ma sensor inputs; standard setup and configuration

USER INTERFACE & CONTROLLER Specifications subject to change without notice. USA 09 Page of Keypad User Interface Alarm Orange LED Alarm Red LED Failure Yellow LED Power Green LED Alarm Alarm INTEC Controls Flashes when any stage level setpoint is exceeded; steady when any relay output is in manual override operation Flashes when high alarm stage or multiple alarm stage level setpoints are exceeded; steady when any relay output is in manual override operation Flashes when system or sensor fails Steady when power is ON Exit programming mode and saves settings; return to previous level or menu Enter Main Menus; scrolls through Main Menus and Sub Menus; increase or decrease a value Navigates through menus on the same level; moves cursor when inputing data Enter Sub Menus; accepts and stores data; silence horn (if assigned) Main Page & Main Menu INTEC Controls System Errors Stage Status Relay Status Sensor Readings Relay Setup SP Setup System Operation All programming is made via the keypad user interface in combination with the display screen. Security is provided via two password levels. The lower level password () allows to override or to reset system status functions. The upper level password (900) allows all programming and override functions. Main Page Display After powered on, displays INTEC and part number and changes to sensor reading display unless a system error occurs; then the error is displayed. Main Menu Displays headings of System Errors, Stage Status Relay Status, Sensor Readings, Relay Setup, SP (Sensor Point) Setup, and System Setup. Sub Menu System Errors Displays errors, reset corrected errors, and historical error summary. Sub Menu Stage Status Displays status of each SP sensor point, stage level/setpoint exceeded. Sub Menu Relay Status Displays status and manual control of each output relay. Sub Menu Sensor Readings The current and mean/average values are displayed for each SP sensor point with sensing type and engineering unit (ppm, %v/v, %LEL, F, %RH). Sub Menu Relay Setup Enter and/or change parameters of each relay. - Assign de-energized or energized normal operation - Select steady or flashing function - Select horn function - Select latching or non-latching mode - Select digital input usage, and assign to any output relay - Set delay ON/OFF time Sub Menu SP Setup Enter and/or change parameters of each sensor point. - Activate sensor point - Select sensor point type (gas, temperature, humidity) - Select measuring range - Select sensor signal - Select stage/setpoint to - Select hysteresis - Set delay ON/OFF time - Select current or mean/average value - Assign sensor point fault to stage level setpoint - Assign setpoint to to any output relay - Assign to analog output Sub Menu System Setup Enter and/or change system parameters. - Select service mode - Display software version - Set next maintenance date - Select service phone number - Select averaging function, time and overlay, of any SP - Set date, time and time format - Change customer password - Set failure relay - Select power ON time - Select analog output function System Setup

Specifications subject to change without notice. USA 09 Page of WIRING CONFIGURATION Analog Inputs MP0 / MP0 without Modbus -0 ma, -wire sensor/transmitter -0 ma (MP0) -0 ma (MP0) VAC or VDC** -0 ma, -wire loop-powered sensor/transmitter VAC/VDC Input Power Supply, without Modbus ***Jumper output signal AO0 range selectors: 0-0% V-A -0 ma (MP0) -0 ma (MP0) VDC** Over both pins Pins not covered Over both pins Pins not covered (0) -0 ma, or (0) -0 VDC*** VAC/VDC** -0%/%, 0/0 Hz = VDC = ma = -0 ma / -0 VDC = 0-0 ma / 0-0 VDC Binary-Relay Outputs R0 and R0, VDC switched Output R and R, and Digital Input R 0 V R R R DIO + V NO NC X 8 9 0 Digital Input NO NC NC/NO** Int. Buzzer R = SPDT, 0 VAC/DC, 0. A R = NO/NC, 0 VAC/DC, 0. A R/R = Open Collector, 0...0 VDC, 0 ma VAC/VDC Input Power Supply, with Modbus Communications BUS_B BUS_A -0 ma (MP0) -0 ma (MP0) VAC or VDC** Twisted, shielded wire is recommended for - or - wire configurations. **/*** Caution: Only the same type of power, VAC or VDC, as supplied to the unit, is available for the remote transmitter. i.e. When VDC transmitter power is required, the unit must be powered with VDC. -wire loop-powered transmitter can use the internal power. -wire transmitters that allow power common to DC common can use the same power supply to power the and the transmitter. -wire transmitters that require separate power common from DC common must use a separate power source.