TECHNICAL PRODUCT DATASHEET

Similar documents
Premium Desoldering station with Electric Pump Ref. DIS-D

Hot Air Station without Extractor desk Ref. JTSE-QA

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

MicroCoat Flow Guard Operating Manual

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

YVP110 Advanced Valve Positioner. Please use the attached sheets for the pages listed below in the following manuals. IM 21B04C01-01E (10th)

Living Space Sensor Touchscreen Covers SXWSCDXSELXX (Touchscreen Display) SXWSCDPSELXX (Touchscreen Display with Occupancy Sensor)

MicroCoat Flow Guard. MC480M Series. Operating Manual. IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors

Model 685B1001A10. Electronic Vibration Switch. Installation and Operating Manual

MultiTemp IV Thermostatic Circulator

Micro800 Programmable Controller External AC Power Supply

User Manual. OCTAVIUS Detector 729 (T10040) and Detector Interface 4000 (T16039)

Tokyo Gas Engineering Solutions Corporation

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

Q-SERIES DI WATER HEATER

Dual SDI Optical to Electrical Converter

Wideband Optical Couplers

Ultimus I II High Precision Fluid Dispensers

ETH1000-MKII. User manual

Installation Guide (English) for other languages see

Tokyo Gas Engineering Solutions Corporation

ETH1000-D. User manual

L100 Classic. Iconic 3-Way Bookshelf Loudspeaker OWNER S MANUAL

MODEL 4312SE. 12-Inch (300mm), 3-Way Studio Monitor OWNER S MANUAL

说明书 澳大利亚 ARTUSI KH90A-F1N160 薛孝田 印刷说明 : 2.. 此印刷品自 起开始实施 3. 此印刷品最终成品大小为 A4 纸一半大小 4. 此印刷品黑白印刷 5. 此印刷品要求字迹清晰 不能有漏印 错印 模糊现象 客户名称 产品型号 会签 型号经理

Model 685B0001C14. Electronic Vibration Switch. Installation and Operating Manual

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

所有的资料是按最新出版的产品资料编写而成遥科勒公司保留任何时候不经通知即可改变产品特性尧包装或产品可供类型的权利遥 说明书包括重要的安装内容袁请把这些资料交给用户阅读遥

Shaking Peltier Device

CONTENTS. I Description II Specification III Structure IV Mounting and Wiring V Application VI Troubleshooting...

Contents. Precision Lead-free Reflow Oven. Model: AT-R3028

Portable Ionizing Air Gun PIA 型离子风枪 型号 : 94101

Operating Instructions

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Rosemount 214C Sensor. Quick Start Guide , Rev BB March 2019

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

A New Generation of Active Intrusion Detection System for Physical Protection

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

KMART Corrective Action Plan

LEC TF55207W(CE-BCD275WM-SQ) 重量 (g) WEIGHT. 比例 scale 第页 NO. OF SHEETS

VuPoint M-Series Touchcomputer User Guide

Carbon Monoxide Transmitter

LEVEL SENSORS & FLOAT SWITCHES

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Analog Room Pressure Monitor RPC Series

2012 Toolbar & NH3 Operators Manual

Operator Manual HIAC HRLD

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

Tachometer/Hourmeter/Trip. Installation and Operation Manual

GETTING STARTED GUIDE NI NI-XNET Hardware Selectable Interface. Français Deutsch 日本語한국어简体中文. ni.com/manuals

CLEANROOM MONITOR CR3A Network - Installation Instructions

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

PolyBox TM. Edition II. Operation Manual

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

HC1089 HC Koninklijke Philips N.V. All rights reserved 保留所有权利 (25/9/2017) > 75% 循环再造纸

美的吸尘器 使用说明书 VACUUM CLEANER OPERATION INSTRUCTIONS MANUAL C5 PRO (C5-L121D) 使用产品前请仔细阅读本说明书 并请妥善保管

DC200 Digital Dispenser Operating Manual

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

HRX3000. Technical Manual

1. These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do not re

Indesit,CVTAA 55 NF UK, CVTAA 55 NF UK S( CE-BCD275W-S, ) 英文说明书 版本号 REV.NO. 重量 (g) WEIGHT

Rosemount 848T High Density Temperature Measurement Family

Register your product and get support at 在以下网站注册并获得支持

Question? 有疑问? Contact Philips 请联系飞利浦 FC6132 FC6130

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

RAS-DX18HDK/RAC-DX18HDK

HRX Technical Manual. Version 1.2

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Fortimo LED Line High Flux Module

2 / These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do

Preparation. Name of Each Part. Safety Precautions (Be sure to always follow these precautions) ECLEAR MIST. HCE-HU03 Series. Turning the power on

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

SOLARBOX Models 1500e RH and 3000eRH Accelerated xenon light fastness and weathering test chambers

Use & Care Manual Inset Electric Fires

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

GB Translated English of Chinese Standard: GB

WPHO - LED HIGH OUTPUT WALL PACKS

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

UNC100 Integra Manual

General Purpose IO Technical Manual

PQS performance specification

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Use & Care Manual Contemporary Electric Fires

Fortimo LED Line Gen2 Module

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

GPS Evaluation Kit EVA1037/1080

20 Light Remote Annunciator

DC MOTOR FAN COIL UNIT 直驅無刷电机风机盤管

Pump-Up Controller MODEL 4062

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

HEP Tech Co., Ltd. Company Profile

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

DMFPM-2R MULTIFUNCTIONAL

Transcription:

ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR EXTERNAL DISTRIBUTION ENFO IV P/N 108661 P/N 112600 (metric) P/N 112600-03 (metric, Chinese)

PAGE 1 of 12 1. REVISION LOG... 2 2. SYSTEM OVERVIEW... 3 2.1. 2.2. SCOPE... 3 PART NUMBERS... 3 3. OPERATION... 4 3.1. DISPLAY... 4 3.1.1. ENGINE RPM display window... 4 3.1.2. VOLTAGE display window... 4 3.1.3. OIL PRESSURE display window... 4 3.1.4. ENGINE TEMP display window... 4 3.2. DEFINED ALARM CONDITIONS... 4 3.2.1. Audible alarm and alarm silence switch... 4 3.3. INITIALIZATION... 5 4. MENU... 6 4.1. 4.2. ENTERING THE MENU... 6 MENU ITEMS... 6 5. INSTALLATION... 9 5.1. 5.2. CUTOUT DIMENSIONS... 9 OUTER BEZEL DIMENSIONS... 9 6. WIRING... 10 7. ACRONYM LIST... 10 8. TECHNICAL DETAILS... 11 8.1. ELECTRICAL AND PHYSICAL SPECIFICATIONS... 11 9. 产品中有毒和有害的物质或成份的名称和含量 (NAMES AND CONTENTS OF THE TOXIC AND HAZARDOUS SUBSTANCES OR ELEMENTS IN THE PRODUCTS)... 12

PAGE 2 of 12 1. Revision Log Rev Date Approved Changes 1.10 6-2-2008 AGK Initial requirements 1.20 1-3-2013 MH Corrected typo in section 4.2 regarding menu items being displayed in OIL PRESSURE window 1.30 5-27-2016 GMC Added CAN Auto Baud Information

PAGE 3 of 12 2. System Overview 2.1. Scope The ENFO IV is an engine monitoring device that reads and displays: engine RPM, engine coolant temperature, and engine oil pressure via SAE J1939 CAN messages from the engine Electronic Control Unit (ECU). The ENFO IV also displays vehicle voltage but this is independent of SAE J1939 CAN operation. The ENFO IV can be used on both 12 and 24 Volt systems. The ENFO IV uses an automatic voltage detection system to determine the low voltage point for alarm activation. The ENFO IV can be connected to an external alarm and external alarm silence switch. High engine temperature (250 F / 120 C), low oil pressure (10 PSI / 70 kpa / 0.70 Bar), or low voltage (11.9V or 23.8V) will cause the ENFO IV to activate the external alarm. 2.2. Part numbers ENFO IV (English units) C1 P/N 108661 12V and 24V ENFO IV (Metric units) C1 P/N 112600 12V and 24V ENFO IV (Metric units) C1 P/N 112600-03 12V and 24V Colored corner tags Beige C1 P/N 106669 Black C1 P/N 106030 Blue C1 P/N 106023 Brown C1 P/N 106025 Burgundy C1 P/N 106667 Gray C1 P/N 106668 Green C1 P/N 106022 Lime C1 P/N 106670 Light Blue C1 P/N 106671 Orange C1 P/N 106028 Pink C1 P/N 106024 Purple C1 P/N 106666 Red C1 P/N 106029 Rust C1 P/N 106027 Silver C1 P/N 106026 White C1 P/N 106665 Yellow C1 P/N 106664 Installation Harness C1 P/N 110346 10 feet Terminating resistor (CAN) C1 P/N DT06-3S-P006 Y connector (CAN) C1 P/N DT04-3P-P007

PAGE 4 of 12 3. Operation 3.1. Display The ENFO IV has 4 display windows which use 7-segment LEDs to show information and warnings received from the engine ECU (source address 0). For applications where the engine ECU address is not 0 (or the SAE J1939 CAN data is not transmitted from a device with the source address of 0) the ENFO IV can be set-up to mask the source address to ensure that the data will be received regardless of the transmitting devices source address number (see section 4.1). 3.1.1. ENGINE RPM display window The engine RPM is received from the engine ECU via J1939 CAN message PGN 61444 (bytes 4 and 5) and displayed in this window. Dashes will be displayed when PGN 61444 is not received. 3.1.2. VOLTAGE display window The vehicle voltage information is calculated within the ENFO IV based on the voltage present at pin 4 (supply voltage +) referenced to the ground potential present at pin 5 (supply voltage -). 3.1.3. OIL PRESSURE display window The oil pressure is received from the engine ECU via J1939 CAN message PGN 65263 (byte 3) and displayed in this window. Dashes will be displayed when PGN 65253 is not received. 3.1.4. ENGINE TEMP display window The engine (coolant) temperature is received from the engine ECU via J1939 CAN message PGN 65252 (byte 0) and displayed in this window. Dashes will be displayed when PGN 65252 is not received. 3.2. Defined alarm conditions The ENFO IV sounds the external alarm and alternately displays a warning in the associated display window when any of the following conditions is true. Display window Condition Description Oil pressure 10 PSI (70 kpa / 0.70 Bar) or less Display alternately shows the pressure and LO Engine temp 250ºF (120 ºC) or greater Display alternately shows the temperature and HI Voltage 11.9V or less (12V system) 23.8V or less (24V system) Display alternately shows the voltage and LO 3.2.1. Audible alarm and alarm silence switch The ENFO IV can be connected to an external audible alarm (250mA maximum) and alarm silence switch. When the ENFO IV activates the alarm it will remain ON until the alarm condition is no longer present or the alarm silence button has been pressed. The alarm will remain OFF for 5 minutes after which time the alarm will again activate (if the alarm condition is still present).

PAGE 5 of 12 3.3. Initialization The ENFO IV s initialization sequence is listed in the table below. This initialization sequence is designed to test the display LED segments and alert the observer to the voltage range detected and CAN status. Description Displayed data Auto Baud Selection will run on the first power up or if the Auto Baud reset has been activated. Once the baud rate has been determined it will save it to memory and no longer display this screen on power up. Each display lights all of the LED segments for one second. The software revision is shown in the VOLTAGE display for one second. The CAN status is shown in the ENGINE RPM and OIL PRESSURE displays. CAN GOOD indicates that at least one CAN message is being received and the physical CAN connections are good. NO CAN indicates that no CAN messages are being received and that there may be an issue with the physical CAN connections. The voltage range is shown in the ENGINE TEMP display. =12 indicates that the voltage range is detected between 9V and 17.5V. =24 indicates that the voltage range is detected between 17.6V and 32V. The ENFO IV then begins normal operation by displaying received data.

PAGE 6 of 12 4. Menu 4.1. Entering the menu Press and hold the external silence switch until the ENGINE RPM display shows SEL (approximately 5 seconds). Release the external silence switch. Press the silence switch to cycle through the menu items (see section 4.2). 4.2. Menu items Menu selection is handled by pressing the external silence switch to select the desired menu item (shown in the OIL PRESSURE window) and then allow the time remaining indicator (time in seconds shown in the ENGINE TEMP window) to count down to 0. Each activation of the silence switch resets the time remaining indicator back to 5 seconds. Menu item Description Secondary menu item Description Exit menu Allow the timer to time-out to exit the menu. NONE NONE Note 4 Unit of measure Select the unit of measure for the temperature display (English or metric). Use the silence switch to toggle the unit of measure shown in the VOLTAGE window (ENG = English, INT = metric). When the desired selection is shown allow the timer to count down to 0 to save to memory. Test displays Turn all LED segments and alarm output ON for 3 seconds. NONE NONE View the battery range View the auto-selected battery voltage range. =12 indicates the ENFO IV has auto-detected 12 Volt range. =24 indicates the ENFO IV has auto-detected 24 Volt range. NONE NONE Show alarm point Show the alarm trip points for the VOLTAGE, OIL PRESSURE, and ENGINE TEMP displays. NONE NONE

PAGE 7 of 12 Menu item Description Secondary menu item Description Source address selection Note 2 Allows selection of source address for the three SAE J1939 CAN messages. Either the normal engine ECU address (0) or any address may be selected. The menu goes through each CAN message individually beginning with OIL PRESSURE, then ENGINE TEMPERATURE, and finally ENGINE RPM. Use the silence switch to toggle the source address shown in the VOLTAGE window (nor = normal address 0, Any = any address is allowed). When the desired selection is shown allow the timer to count down to 0 to save to memory. Low Voltage Alarm Enable Allows the low voltage alarm to be enabled or disabled. Use the silence switch to toggle the unit shown in the VOLTAGE window (ON, OFF). When the desired selection is shown allow the timer to count down to 0 to save to memory.. Voltage accuracy tune Allows tuning the voltage accuracy. Due to minor differences in the protection components within the ENFO IV the voltage accuracy may be slightly inaccurate (low) and this menu item allows adding tenths of volts to correct the inaccuracy. Use the silence switch to toggle the tenths of volts shown in the VOLTAGE window. When the desired selection is shown allow the timer to count down to 0 to save to memory. CAN Baud Rate Selection The ENFO IV can be set to work with either 250k or 500k baud rate. Use the silence switch to toggle the unit shown in the VOLTAGE window (250, 500). When the desired selection is shown allow the timer to count down to 0 to save to memory. Note 5 Note 6 Auto Baud Reset Selection The Auto Baud Selection on power up can be reset. When the timer counts down to 0 the selection will be save to memory. Then the display will direct the user to power the unit down. On the next power cycle it will auto detect the CAN baud rate if the unit is connected to the CAN network.

PAGE 8 of 12 Menu item Description Secondary menu item Description Show mode The ENFO IV can be set to show mode. This mode is useful as a show display when CAN data is not present. This mode is not intended as a functional mode. Use the silence switch to toggle the show mode (ON or OFF) shown in the VOLTAGE window. Show mode only lasts for the current power cycle. Alarm silence input verification Allows verification of the ground input for alarm silence operation. The OIL PRESSURE window shows the current state of the input in number of bits (0 to 1023). When the alarm silence input is activated with a ground the number will be closer to 0. Note 3 Bootload Enter the firmware upgrade mode (bootloader). The unit is now in firmware upgrade mode. The new firmware must be loaded for the unit to function. This will disable the unit if not reprogrammed! : These items are only available within the first 60 seconds after power-up. Note 2: This item is only available for software version 1.5 and later. Note 3: This item is only available for software version 1.4 and later. Note 4: This item is only available for software version 1.3 and later. Note 5: This item is only available for software version 1.6 and later. Note 6: This item is only available for software version 1.7 and later.

PAGE 9 of 12 5. Installation 5.1. Cutout dimensions The display requires a cutout as shown. The display is water tight and may be mounted in any location on the operator s panel. Unit of scale: inches [millimeters] 5.2. Outer bezel dimensions Unit of scale: inches [millimeters]

PAGE 10 of 12 6. Wiring Mating connector: Amp P/N 776286-1 C1 P/N 106297 Mating sockets: Amp P/N 770520-3 C1 P/N 106298 Recommended wire gage: 14-18 AWG PIN CIRCUIT DESCRIPTION 1 CAN High CAN communication (SAE J1939, 250KB/s) 2 CAN Low CAN communication (SAE J1939, 250KB/s) 3 CAN Shield CAN communication (SAE J1939, 250KB/s) 4 Supply + Module supply (+9VDC +32VDC) 5 Supply - Module supply (ground) 6 Silence input Alarm silence input (ground polarity) 7 Alarm + Alarm output supply (positive supply voltage) 8 Alarm - Alarm output (ground, switched output) 7. Acronym list LED Light Emitting Diode. The lights on the display used to show tank level and information PSI Pounds per Square Inch. Pressure measurement kpa kilo Pascal. Pressure measurement CAN Controller Area Network. SAE J1939 communication method SAE Society of Automotive Engineers TBD To Be Developed ESD ElectroStatic Discharge IP Ingress Protection (IP 67, etc) P/N Part Number C1 Class 1 ECU Electronic Control Unit PGN Parameter Group Number ma milli Amps AWG American Wire Gauge

PAGE 11 of 12 8. Technical details 8.1. Electrical and physical specifications Product category ENFO IV Voltage range +9VDC +32VDC Power consumption @13.8VDC @27.6VDC 185 ma 115 ma Operational temperature range -40ºC +85ºC Alarm output 250 ma maximum (ground polarity) Environmental range IP 67 CAN specification SAE J1939 proprietary, 250 Kbits/second Protection Internal thermal fuse Reverse voltage protection (pins 1 and 2 of connector) CAN buses protected to 24V ESD voltage protected to SAE J1113 specification for heavy duty trucks Transient voltage protected to SAE J1113 specification for heavy duty trucks Dimensions (W x H x D) in inches 5.635 [143.12] x 2.830 [71.88] x 2.060 [52.32] Weight in ounces [grams] 6.7 [189.94]

PAGE 12 of 12 9. 产品中有毒和有害的物质或成份的名称和含量 (NAMES AND CONTENTS OF THE TOXIC AND HAZARDOUS SUBSTANCES OR ELEMENTS IN THE PRODUCTS) Class1 is committed to comply with the Management Methods on Control of Pollution from Electronic Information Products of China (China RoHS). The RoHS Directive restricts substances including lead (Pb), mercury (Hg), Cadmium (Cd), hexavalent chromium (CrVI) and certain halogenated flame retardants such as polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) in electrical and electronic equipment. 零件名称 Parts 铅 (Pb) 有毒和有害的物质或成份 TOXIC AND HAZARDOUS SUBSTANCES OR ELEMENTS 汞 (Hg) 六价铬 (CrVI) 多溴联苯 (PBBs) 多溴二苯醚 (PBDEs) 镉 (Cd) 盒子 Box 面板 Faceplate 标签 Label 元器件 Components 连接器 Connector 基准 Base 螺钉 Screw 印制电路 PCB 镀层 Coating X O O O O O X O O O O O : 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T 11363-2006 标准规定的限量要求以下 :Indicates that this hazardous substance contained in all homogeneous materials of this part is below the limit requirement in SJ/T 11363-2006. : 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T 11363-2006 标准规定的限量要求 :Indicates that this hazardous substance contained in at least one of the homogeneous materials of this part is above the limit requirement in SJ/T 11363-2006. 除非另外特别的标注, 此标志为针对所涉及产品的环保使用期限标志. 此环保使用期限只适用于产品在产品手册中所规定的条件下工作. The Environment-Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here, unless otherwise marked. The Environment-Friendly Use Period is valid only when the product is operated under the conditions defined in the product manual.