Wideband Optical Couplers
|
|
- Harry Robinson
- 5 years ago
- Views:
Transcription
1 Flashlink User Manual WOC WOC WOC WOC-4-25 Wideband Optical Couplers network-electronics.com Rev. 3
2 Network Electronics ASA Thorøya P.O. Box 1020 N-3204 Sandefjord, Norway Phone: Fax: Support Phone: Revision history Current revision of this document is the uppermost in the table below. Rev. Repl. Date Sign Change description RS Added WOC-4-25, applied new template, added new EC Declaration of Conformity, and added Appendix A Materials declaration and recycling information RS Added specification on multi mode coupler RS Changed Laser Safety Precaution description 0 A NBS Renamed Optronics to Electronics & Rev. Control A RS Initial revision network-electronics.com 2
3 Contents Revision history Product overview Specifications WOC-2-xx-xx Single mode fibre (9/125 um) Multi mode fibre (62.5/125um) WOC Single mode fibre (9/125um) Connections Mounting the connector module Preparation of module Applying signals to the WOC-2-xx-xx connector module Application examples Module status Front Panel - Status Monitoring Laser safety precautions...11 General environmental requirements for Network Electronics equipment...12 Product Warranty...13 Appendix A Materials declaration and recycling information...14 A.1 Materials declaration A.2 Recycling information EC Declaration of Conformity...15 network-electronics.com 3
4 1 Product overview The Wideband Optical Couplers (WOC) in the Flashlink range are all-optical power splitters or combiners. One or multiple wavelengths can be used on the fibres. Today the product offering consists of WOC-2-xx-xx which is a 1:2 optical coupler available with different coupling ratios. The WOC-4-25 is a 1:4 optical coupler, where the optical power is divided and distributed equally to the four output ports. Figure 1: Block diagram of the WOC-2 module operation. The Flashlink 1:2 Wideband Optical Coupler is a fibre optical splitter/combiner module for use together with the W03-C1 connector module. A typical application for these units is multiple distribution and linear, tapped fibre optic bus structures. The unit is passive and there is no need for power or control. The WOC-2 optical coupler is made for the 2nd and 3rd optical window (1310nm and 1550nm) and is available with three different split ratios: WOC %-50% split ratio WOC %-10% split ratio WOC %-05% split ratio The WOC-2 has two input/output ports and one common port. The product is also available with multi mode fibre on request. Figure 2: Block diagram of the WOC-4-25 module operation. A typical application for the WOC-4-25 is distribution to multiple locations of single or multiple signals using WDM. The WOC-4-25 optical coupler is made for wavelengths from 1260 up to 1620nm thus covering the whole CWDM band. network-electronics.com 4
5 2 Specifications 2.1 WOC-2-xx-xx Single mode fibre (9/125 um) Optical wavelength: 2nd & 3rd opt. window (1310 nm & 1550 nm) Optical bandpass: nm & nm Return loss: Better than 40 db w/sm fibre Directivity: Better than 55 db Transmission circuit fibre: Single Mode Connector: SC/UPC Split ratios and corresponding maximum insertion loss (incl. connectors): WOC : 50 % / 50 % 4.3 db / 4.3 db WOC : 90 % / 10 % 1.33 db / 11.7 db WOC : 95 % / 05 % 1.1 db / 15.3 db Multi mode fibre (62.5/125um) Optical wavelength: 2nd opt. window (1310nm) Directivity: better than 40dB Transmission circuit fibre: Multi Mode Connector: SC/UPC Split ratios and corresponding maximum insertion loss (incl. connectors): WOC : 50 % / 50 % 4.8 db / 4.8 db 2.2 WOC Single mode fibre (9/125um) Optical passband: nm Return loss: Better than 40 db typ w/sm fibre Directivity: Better than 55 db typ Transmission circuit fibre: Single Mode Connector: SC/UPC Split ratio: 25%/25%/25%/25% Insertion loss with connectors: Max 9dB over passband. network-electronics.com 5
6 3 Connections The WOC-2 has the same connector module as thewdm-2: W03-C1. This module is mounted at the rear of the sub-rack. The module is shown in Figure 3. Figure 3: Overview of the W03-C1 connector module. Figure 4: Overview of the WOC-4-25 connector module network-electronics.com 6
7 The WOC-4-25 is a self contained box similar to the CWDM filters that is mounted permanently in the Flashlink FR-2RU-10-2 from the rear. Figure 5: The WOC-4-25 The WOC-4-25 can also be delivered in the N-BOX, which is used for stand alone applications. 3.1 Mounting the connector module This section only applies to the WOC-2-xx-xx if the module is not purchased pre-mounted in a sub-rack. The details of how the connector module is mounted, is found in the user manual for the sub-rack frame FR-2RU This manual is also available from our web site: Preparation of module Just before the module and the connector module are put together, the dust caps should be removed and stored in the enclosed plastic bag. The dust caps are removed from the connector module and the module card as we see in Figure 6 and Figure 7. Figure 6: Removal of the dust caps from the WOC connector module. network-electronics.com 7
8 Figure 7: Removal of plastic dust caps from WOC module. 3.3 Applying signals to the WOC-2-xx-xx connector module Optical 1 is always the common port (orange lead). Optical 2 has largest 1 coupling ratio (blue lead) Optical 3 has lowest coupling ratio (natural lead). 3.4 Application examples We show some examples of how a WOC can be used for different applications. Tx 50 / 50 WOC Rx 1 Rx 2 Figure 8: Redundant solution Same signal on two different fibres. In Figure 8 we have a solution where the signal path from transmitter (Tx) to the receiver (Rx) is redundant. Since both Rx1 and Rx2 are located at the same place, the signal is divided into two equal parts and transmitted over two different fibres. At the receiver end the same signal is present from different receiver cards, a redundant solution. This solution is also suitable for transmitting the same signal to two different locations; each located approximately the same distance from the transmitter. If the distances from the two different receiver-locations to the transmitter are very different a WOC or a WOC is more suitable. Which WOC to use in which case can be found by calculating the optical transmission budgets for the involved links, or by calling your Network Electronics representative. More information on transmission budgets can be 1 A WOC has the same coupling ratio for both Optical 2 and Optical 3. network-electronics.com 8
9 found in the user manual for the sub-rack frame, and on our web site Tx 90 / 10 WOC Rx 2 Rx 1 Figure 9: Signal tapping / monitoring / distribution with a WOC If one of the Rxs for some reason is not connected, we recommend bypassing the WOC module until the Rx is in operation again. This is to avoid back-reflections degrading the signal. network-electronics.com 9
10 4 Module status The WOC-2-xx-xx and the WOC-4-25 are all-optical modules with no electrical connections; hence there will be no on-board processing or monitoring. If the module is faulty this can be monitored on the receiver end. The only possibilities for the module to fail are if either te fibre is broken, or the fibre connections at the rear are bad. Then no signal will pass the module. 4.1 Front Panel - Status Monitoring The WOC-2-xx-xx and the WOC-4-25 are all-optical modules, so there are no LEDs on the module. network-electronics.com 10
11 5 Laser safety precautions These are guidelines to limit hazards from laser exposure. All the available EO units in the Flashlink range include a laser. Therefore this note on laser safety should be read thoroughly even though there is no laser onboard this product. The lasers emit light at 1310 nm or 1550 nm. This means that the human eye cannot see the beam, and the blink reflex cannot protect the eye. (The human eye can see light between 400 nm to 700 nm). A laser beam can be harmful to the human eye (depending on laser power and exposure time). Therefore: Be careful when connecting / disconnecting fibre pigtails (ends). Never look directly into the pigtail of the laser/fibre. Never use microscopes, magnifying glasses or eye loupes to look into a fibre end. Use laser safety goggles blocking light at 1310 nm and at 1550 nm Instruments exist to verify light output power: Power meters, IR-cards etc. Flashlink features: The FR-2RU-10-2 is classified as Class 1 laser product according to EN :94/A11:96, and CFR Ch1 (1997) Part If the front panel is removed, the FR-2RU-10-2 is classified as Class 1 laser product according to EN :94/A11:96, and class IIIb according to CFR Ch1 (1997) Part Maximum output power 2 : Operating wavelengths: 5 mw > 1260 nm 2 Max power is for safety analysis only and does not represent device performance. network-electronics.com 11
12 General environmental requirements for Network Electronics equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: - Operating room temperature range: 0 C to 50 C - Operating relative humidity range: Up to 90 % (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: - Temperature range: -10 C to 55 C - Relative humidity range: Up to 95 % (non-condensing) network-electronics.com 12
13 Product Warranty The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Network Electronics ASA. These conditions are available on the company web site of Network Electronics ASA: network-electronics.com 13
14 Appendix A Materials declaration and recycling information A.1 Materials declaration For product sold into China after 1st March 2007, we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products. In the first stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information. 組成名稱 Part Name 鉛 Lead (Pb) 汞 Mercury (Hg) Toxic or hazardous substances and elements 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr(VI)) 多溴联苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) WOC / / WOC-4-25 O O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T This is indicated by the product marking: A.2 Recycling information Network Electronics provides assistance to customers and recyclers through our web site Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require. Where it is not possible to return the product to Network Electronics or its agents for recycling, the following general information may be of assistance: Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. All major parts are marked or labelled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices. network-electronics.com 14
15 EC Declaration of Conformity MANUFACTURER AUTHORISED REPRESENTATIVE (Established within the EEA) MODEL NUMBER(S) DESCRIPTION DIRECTIVES this equipment complies with HARMONISED STANDARDS applied in order to verify compliance with Directive(s) Network Electronics ASA P.B. 1020, N-3204 SANDEFJORD, Norway Not applicable WOC /-90-10/ WOC-4-25 Wideband Optical Coupler LVD 73/23/EEC EMC 89/336/EEC EN :1996 EN :1996 EN :2006 TEST REPORTS ISSUED BY Notified/Competent Body Report no: TECHNICAL CONSTRUCTION FILE NO YEAR WHICH THE CE-MARK WAS AFFIXED TEST AUTHORIZED SIGNATORY MANUFACTURER Name Position Nils B. Sannes Quality Manager (authorised signature) Nemko Not applicable 2000 AUTHORISED REPRESENTATIVE (Established within EEA) Not applicable Date of Issue Place of Issue Sandefjord, Norway network-electronics.com 15
CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L
CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L 9-channel CWDM multiplexer and demultiplexer / multi mode (-M) / -low-loss (-L) User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway
More informationCWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.
18 channel CWDM mux/demux User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1:
More informationETH1000-MKII. User manual
ETH1000-MKII Gigabit Ethernet Media Converter User manual Rev. 1 1 Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion
More informationETH1000-D. User manual
ETH1000-D Gigabit Ethernet Media Converter with DWDM laser User manual Rev. 2 Nevion Europe P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www. Nevion Support Nevion Europe
More informationDual SDI Optical to Electrical Converter
Flashlink User Manual SDI-OE-2 Dual SDI Optical to Electrical Converter network-electronics.com Rev. 3 Network Electronics ASA Thorøya P.O. Box 1020 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33
More informationUSER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM
Rev. 0 USER MANUAL WDM-D15xx.xx Single Wavelength Add/Drop Module for DWDM Network Electronics ASA Thorøya 3204 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 e-mail: support@network-electronics.com
More informationMicroCoat Flow Guard Operating Manual
A NORDSON COMPANY MicroCoat Flow Guard Operating Manual MC480M Series Electronic pdf files of EFD manuals are also available at www.efd-inc.com/manuals.html Contents Introduction...3 Specifications...4
More informationMicroCoat Flow Guard. MC480M Series. Operating Manual. IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors
MicroCoat Flow Guard Operating Manual MC480M Series IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors Electronic pdf files of EFD manuals are also available at www.nordsonefd.com
More informationOperating Instructions
Operating Instructions ProVicom MT-65, MT-125 R. STAHL HMI Systems GMBH Im Gewerbegebiet Pesch 14 50767 Köln Version 1.7 Issue: 21.07.2008 R. STAHL HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc
More informationImportant Safety Notice
Date: 27 th April 2015 Page 1 of 12 SPI Lasers UK Limited Safety Information High Power OEM Fibre Lasers Important Safety Notice This notice outlines important safety related information and must be read
More informationProduct Specification
Product Specification R9400SA UltraSpan ROPA Pump Unit 1600 mw Output Power, 3U PN: FOA-R9400SA-RPA6C-AA017 Document No.: 1215607 Revision: A00 Date: 16-Jun-14 Customer: General Product Features Fully
More informationOTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL
OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS
More informationPD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.
PD100MF0MPx Surface Mount Type, Opaque Resin Photodiode Features 1. Compact and thin SMD package 2. Top view and side view mountable 3. Plastic mold with visible light cut-off black resin lens 4. Peak
More informationTECHNICAL PRODUCT DATASHEET
ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR EXTERNAL DISTRIBUTION ENFO IV P/N 108661 P/N 112600 (metric) P/N 112600-03 (metric, Chinese) PAGE 1 of 12 1. REVISION
More informationProduct Specification
Product Specification R9300TH Hybrid Raman-EDFA, Dual Raman Pump PN: FOA-R9300TH-HBR3C-AA001 Document No.: 1213710 Revision:A0 0 Date: 18-May-14 Customer: General Product Features Integrated Raman and
More informationMobrey MCU900 Series 4 20 ma + HART Compatible Controller
IP2030/QS, Rev AB Mobrey MCU900 Series 4 20 ma + HART Compatible Controller Quick Start Guide for Installation Failure to follow safe installation guidelines could result in death or serious injury The
More informationDescription. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1
Description The DFB-1XXX-BF-XX-CW-Fx-Hx-N127 series of Multi-Quantum Well (MQW) Distributed Feedback (DFB) lasers have been designed specifically to satisfy the requirements of the sensor application.
More informationDescription. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications
Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially
More informationIron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.
USER GUIDE TB-9022 Iron Man Plus Workstation Monitor Installation, Operation and Maintenance Features and Components Made in the United States of America A B C D Figure 1. Iron Man Plus Workstation Monitor
More informationPremium Desoldering station with Electric Pump Ref. DIS-D
www.jbctools.com Premium Desoldering station with Electric Pump Ref. DIS-D Packing List The following items should be included: DI Control Unit... 1 unit Ref. DI-1D (120V) DI-2D (230V) DI-9D (100V) Electric
More informationRosemount 3490 Series 4 20 ma + HART Compatible Controller
00825-0200-4841, Rev AB Rosemount 3490 Series 4 20 ma + HART Compatible Controller Failure to follow safe installation guidelines could result in death or serious injury The Rosemount 3490 Series Control
More informationRecord of Amendments. Version Date Amendment Section/page affected
Industry support for effective compliance BTHA Guidance on The Restriction Of The Use Of Certain Hazardous Substances In Electrical and Electronic Equipment (recast) (RoHS) Directive 2011/65/EU Comparison
More informationDescription. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications
Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially
More informationGuidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012
Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012 Two Parts: 1. Products first placed on the market between 1 July 2006
More informationRosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016
Rosemount 0085 Pipe Clamp Sensor Assembly 00825-0100-4952, Rev CA NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide instructions for configuration, diagnostics,
More informationQ-SERIES DI WATER HEATER
Phone: 800-669-1303 or 801-561-0303 Fax: 801-255-2312 e-mail: treborservice@idexcorp.com Q-SERIES DI WATER HEATER Operation / Maintenance Manual SERIAL NUMBER: PATENTS: U.S. 5971402, U.S. 6433319, U.S.
More informationT3/E3 Fiber Optic Line Drivers
MT618A-ST-R3 January 2004 MT619A-ST-R2 MT620AE-R2 T3/E3 Fiber Optic Line Drivers CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical
More informationHD IR Vari-focal Dome Network Camera. Quick Start Guide. Version 1.0.0
HD IR Vari-focal Dome Network Camera Quick Start Guide Version 1.0.0 Welcome Thank you for purchasing our network camera! This quick start guide is designed to be a reference tool for your system. Please
More informationPortable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.
Belonging Portable Gas Detector RP110 The RP110 portable gas detector is an electronic instrument manufactured by BEINAT S.r.l. to help technicians during testing or to search for and locate leaks in gas
More information2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base
USER MANUAL 2 WOW MOP COMPONENTS Spray Button Power Button Nozzle Pad Attach (Shadowed Area) Handle Reservoir Base CARTON CONTENTS 3 Measuring Cup WOW Wet Floor Pads WOW Dry Floor Pads Adapter User Manual
More informationLaserPlus Model LP-OA EDFA OPERATING MANUAL
LaserPlus Model LP-OA EDFA OPERATING MANUAL 24926 Highway 108 Sierra Village, CA 95346 Phone: (800) 545-1022 Fax: (209 586-1022 025-370571 Rev. X1 E-Mail: sales@olsontech.com 04/13/11 TABLE OF CONTENTS
More informationEVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector
EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR instruction manual Ref No: NISM/EVC-P/03 Date: Jan 2010 Issue: 3 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2000 NITTAN (UK) LTD. Hipley
More informationIllustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide
Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide 8200-1102-10 B0 Notice Please read this manual thoroughly and save it for future use before attempting to connect or operate this
More informationG4 Pulsed Fiber Laser
G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types C1 and C2 Module type C1 - fitted with IBeam1 delivery optic Module type C2 - fitted with IBeam2 delivery optic 1 1 Preface Definition
More informationThis is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)
QC 080000 Edition 3.0 2012-05 IECQ PUBLICATION IEC Quality Assessment System for Electronic Components (IECQ System) Hazardous Substance Process Management System Requirements (HSPM) INTERNATIONAL ELECTROTECHNICAL
More informationFortimo LED Line High Flux Module
Fortimo LED Line High Flux Module Fortimo LED line 2ft 4000lm 1R LV1 The Fortimo LED Line high flux systems consist of linear white light LED modules with high flux, high energy efficiency, and high quality
More informationGP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)
GPY00AU0F Compact Optical Dust Sensor Description GPY00AU0F is a dust sensor by optical sensing system. An infrared emitting diode (IRED) and an phototransistor are diagonally arranged into this device.
More informationInstallation Manual. Premier IXP-W INS538
Installation Manual Premier IXP-W INS538 1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview... 5 Mounting the
More informationErbium-Doped Fiber Amplifier (EDFA) - MW Series
Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available
More informationSmart BUS (S-BUS) Home Automation System Simplified Specification
Smart BUS (S-BUS) Home Automation System Simplified Specification I - Introduction: This Document is constructed to assist Consultant and Designer in specifying latest Home Automation Technology Standards
More informationRosemount 214C Sensor. Quick Start Guide , Rev AF August 2017
Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationHot Air Station without Extractor desk Ref. JTSE-QA
www.jbctools.com Hot Air Station without Extractor desk Ref. JTSE-QA Packing List The following items should be included: JTSE Control Unit...1 unit Ref. JTSE-1A (100V / 120V) JTSE-2A (230V) Stand...1
More informationInstallation Manual Premier Elite IXP-W
Installation Manual Premier Elite IXP-W INS538-2 1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier Elite 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview...
More informationFortimo LED Line Gen2 Module
Fortimo LED Line Gen2 Module Fortimo LED Line 1ft 650lm 3R LV2 Fortimo LED Line systems are designed to replace fluorescent lighting in new luminaires. Fortimo LED Line Gen 2 systems are designed to replace
More informationElo Touch Solutions 15.6 Widescreen E-Series RevC All-in-One Touchcomputer
USER MANUAL Elo Touch Solutions 15.6 Widescreen E-Series RevC All-in-One Touchcomputer SW602266 Rev B Copyright 2017 Elo Touch Solutions, Inc. All Rights Reserved. No part of this publication may be reproduced,
More informationSURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE
SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE SM1206UV-405-IL Industry Standard 1206 Package RoHS Compliant UV Emitting LED Water Clear Lens Narrow Viewing Angle Ideal for Curing, Detection, and Medical
More informationMINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR
Inno Mini 2 Specs Provided by www.aaatesters.com MOST ACCURATE COMPACT OTDR SOLA (Smart Optical Link Analyzer) 5 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory
More informationFTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD
FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD 157 APPLICATION NOTE Mario Simard, Product Manager, Optical Business Unit The purpose of any fiber-optic network is to perform high-speed,
More informationFour channel video link For low cost video transmission
User Manual Four channel video link For low cost video transmission CFO First Mile series consist of fi bre optic modems which provide a high quality and losless video transmission for variety of CCTV
More informationOP+DWDM8+1D OP+DWDM8+2D / OP+DWDM40 Fiber Optic DWDM Multiplexers and Demultiplexers
Installation and Operation Manual OP+DWDM8+1D OP+DWDM8+2D / OP+DWDM40 Fiber Optic DWDM Multiplexers and Demultiplexers Edition A 175-100110-00 Delivering the Moment Publication Information 2014 Imagine
More informationRosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016
Rosemount 148 Temperature Transmitter 00825-0100-4148, Rev GA NOTICE This guide provides basic guidelines for the Rosemount 148. It does not provide instructions for detailed configuration, diagnostics,
More information760nm Single mode VCSEL with Peltier Element and Thermistor in TO510
760nm Single mode VCSEL with Peltier Element and Thermistor in TO510 APC11010108xy Features: Laser Enterprise s 760nm VCSELs are designed to meet the requirements for the optical measurement of oxygen
More informationCopyright 2017 by Lasermate Group, Inc.. All rights reserved.
Copyright 2017 by Lasermate Group, Inc.. All rights reserved. Table of Contents Laser Safety Eyewear Overview 2 How to Choose Your Laser Safety Eyewear...3 How to Read...4 Filter Flashlamp/IPL...5 Frames
More informationHEP Tech Co., Ltd. Company Profile
HEP Tech Co., Ltd. Company Profile HEP Group Structure 1. HEP Tech Co., Ltd. Head office / Global sales team / R&D center 2. HEP GmbH Europe sales office / Warehouse / Europe R&D center & DEKRA certified
More informationLASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed
LASER SAFETY Laser is an acronym for light amplification by stimulated emission of radiation. Radiation in this case occurs in the portions of the electromagnetic field with insufficient energy to induce
More informationVIEW500 USER-FRIENDLY STANDARD OTDR
USER-FRIENDLY STANDARD OTDR SOLA (Smart Optical Link Analyzer) 7 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL, Light Source and OPM Fast Booting
More informationRice University Laser Safety Manual
Rice University Laser Safety Manual Environmental Health and Safety MS 123 P.O. Box 1892 Houston, TX 77251-1892 January 2014 RICE UNIVERSITY 1 Introduction The objective of the Rice University Laser Safety
More informationMicrOTDR. Optical Fault Locator. User Manual
Optical Fault Locator Datacom Textron 11001 31 st Place West Everett, WA 98204 TEL: 425-355-0590 Toll Free: 800-468-5557 FAX: 425-290-1600 Internet: www.datacom.textron.com Warranty The MicrOTDR Optical
More informationRosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017
Rosemount 0085 Pipe Clamp Sensor Assembly Quick Start Guide 00825-0100-4952, Rev DC Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide
More informationBose Virtually Invisible 891 and 691 in-wall speakers
Bose Virtually Invisible 891 and 691 in-wall speakers Owner s Guide Brugervejledning Bedienungsanleitung Gebruikershandleiding Guía del usuario Käyttöohje Notice d utilisation Manuale di istruzioni Kezelési
More informationSelf-Leveling Five-Beam Laser Pointer Model No Instruction Manual
40-6680 English 5/23/05 9:24 AM Page 1 Self-Leveling Five-Beam Laser Pointer Model No. 40-6680 Instruction Manual Congratulations on your choice of this Self-Leveling Five-Beam Laser Pointer. We suggest
More informationLiving Space Sensor Touchscreen Covers SXWSCDXSELXX (Touchscreen Display) SXWSCDPSELXX (Touchscreen Display with Occupancy Sensor)
schneider-electric.com 1 SmartX TM Living Space Sensor screen Covers SXWSCDXSELXX (screen Display) SXWSCDPSELXX (screen Display with Occupancy Sensor) Product Description SmartX sensors are a family of
More informationIFS SFP Tranceivers User Manual
IFS SFP Tranceivers User Manual P/N 1069181 REV 02.00 ISS 22AUG11 Copyright Trademarks and patents Manufacturer 2011 UTC Fire & Security. All rights reserved. Interlogix, IFS SFP Tranceivers Brand and
More informationQuick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly
Quick Start Guide 00825-0300-2654, Rev DA Rosemount Volume 1 Sensor Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0068, 0078, and 0183 Sensor models. It does not
More informationNorth Dakota State University Laser Safety
North Dakota State University Laser Safety I. Introduction The laser represents a class of light emitting devices with unique characteristics. Some of these characteristics can result in significant hazards.
More informationElectronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual
1467H-English 8/6/08 10:07 AM Page 1 Electronic Self-Leveling Horizontal Rotary Laser Level Model No. 40-6537 Instruction Manual Congratulations on your choice of this Electronic Self-Leveling Horizontal
More informationXGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more
EN XGUARD-0/-5 LASER SCANNERS for industrial doors XGUARD-0: max. detection range of 9.9 m x 9.9 m XGUARD-5: max. detection range of 5.0 m x 5.0 m User s Guide for product version 0600 and more SAFETY
More informationSYNRAD Laser Safety 101
SYNRAD Laser Safety 101 Version 2.1 Released June 2018 SYNRAD is a registered trademark of Novanta Corporation. Novanta Corporation 2018. All Rights Reserved. No reproduction without written authorization.
More informationClass 1 laser beam sensor safe for your eyes
113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global
More informationOPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB
92-3031 OPERATOR S MANUAL Infinity Series Ceramic CO2 Laser: Models 15XXSB www.iradionlaser.com Table of Contents Table of Contents... 2 Hazard Information... 3 Terms... 3 General Hazards... 4 Label Locations...
More information43PFL6572/V7 39PFL6572/V7 32PFL6572/V7
43PFL6572/V7 39PFL6572/V7 32PFL6572/V7 2 Page Blank Product disposal Guidelines: return this product to a nearby authorized collection center, registered dismantler, recycler, service center when disposing
More informationXiaomi Roborock 2. Robot Hoover USER MANUAL
Xiaomi Roborock 2 Robot Hoover u USER MANUAL Thanks for purchasing Roborock Robotic Vacuum Robot hoover. Please read this user manual carefully before using and keep it properly for future use. CONTENTS
More informationInstruction Manual. Self-Leveling Laser Level Model No
Self-Leveling Laser Level Model No. 40-0912 Instruction Manual Congratulations on your choice of this Self-Leveling Laser Level. We suggest you read this instruction manual thoroughly before using the
More informationCM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications
Cooled 980nm Pump Laser Module Features High output power, >1.0W kink free Fiber Bragg grating stabilization for wavelength locking over the entire operating conditions Hermetically sealed 10pin mini-butterfly
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING MITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 240 2017 SCTE Test Procedures for Testing CWDM Systems in Cable Telecommunications Access Networks NOTICE The Society
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60825-1 1993 AMENDMENT 2 2001-01 PUBLICATION GROUPÉE DE SÉCURITÉ GROUP SAFETY PUBLICATION Amendment 2 Safety of laser products Part 1: Equipment classification, requirements
More informationOWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015
Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical
More informationMINI2 MOST ACCURATE COMPACT OTDR
MOST ACCURATE COMPACT OTDR SOLA, Simplify The OTDR Test Process 5 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL and Light Source Fast Booting
More informationClass 1 laser beam sensor safe for your eyes
13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming
More informationLASER SAFETY BARRIER
LASER SAFETY BARRIER 5' x 6' Portable Laser Barrier No-Trip Base Design High CW and Pulsed Damage Thresholds SB5X6 All Contents Stored In Base OVERVIEW Features Portable 5' x 6' (1.5 m x 1.8 m) Barrier
More informationInstruction Manual. Self-Leveling Rotary Laser Level Model Nos and
Self-Leveling Rotary Laser Level Model Nos. 40-6515 and 40-6516 Instruction Manual Congratulations on your choice of this Self-Leveling Rotary Laser Level. We suggest you read this instruction manual thoroughly
More information64 Max IR Thermometer
64 Max IR Thermometer Instructions PN 4861406 January 2017 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective
More informationRoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS
RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS TITLE: NUMBER: REVISION: RoHS Certificate of Compliance for IntelliTouch Super Flat Profile Screens ES500345 B Sheet 1 of 6 Change
More informationField Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks
Field Testing and Troubleshooting of PON LAN Networks per IEC 61280-4 Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning APC vs UPC PON basics Wavelengths Architecture
More informationLaser Safety Citations
General 1. Lasers are classified appropriately Classify lasers and laser systems according to their relative hazards MSU Laser Safety Manual - Laser Classification, pg 9 2. Beam attenuator present A beam
More informationPremier External TD. Installation Manual INS352-3
Premier External TD Installation Manual INS352-3 1. Accessing the Unit 1 2 Remove the top cap and loosen screw (screw retained in wall plate). Push up head unit and remove. 3 Use a flat head screwdriver
More informationThis second part of the lesson & is dedicated to EMC legal aspect and standards.
This second part of the lesson & is dedicated to EMC legal aspect and standards. We should begin by a first part on the last version of the European directive 2014/30/UE which concerns electronic products
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F
LD-64F INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG 6073-2011 Westermo Teleindustri AB 2001 REV. C Galvanic Isolation Transient Protection Balanced Transmission CE Approved Redundant linjedelare
More informationUser Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)
User s Fiberprime, Inc. Portable 4-Channel Laser Source Instrument www.fiberprime.com Tel: 1-613-5964030 Email: info@fiberprime.com Fax: 1-613-8289398 Portable 4-Channel Laser Source Instrument in Small
More informationFTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION
C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD NEW OTDR GENERATION Tunable DWDM OTDR for testing through MUX/DEMUX channels to provide
More informationProduct Specification
Product Specification M7300CD Variable Gain EDFA, 17 dbm OP, 15-30 db Gain PN: FOA-M7300CD-EVG1C-AA002 Document No.: 1213704 Revision: A00 Date: 01-Apr-14 Customer: General Product Features Variable Gain
More informationELLA ID. High CRI, High lm/w OptoDrive LED-module
ELLA ID ELLA ID High CRI, High lm/w OptoDrive LED-module Page 2 of 24 Pages for reference: Pages for reference:... 2 Introduction... 3 Short form Characteristics... 4 Wiring diagram:... 6 Accessories to
More informationHigh-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305
High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.
More informationVIEW500 FASTEST STANDARD OTDR
FASTEST STANDARD OTDR SOLA, Simplify The OTDR Test Process 7 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL, Light Source and OPM Fast Booting
More informationCE Marking and Technical Standardisation
EDITION 3.0 CE Marking and A G A M B I C A T E C H N I C A L G U I D E Technical Standardisation Guidelines for application to Electrical Power Drive Systems CE Marking and Technical Standardisation Guidelines
More informationRosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017
Rosemount 4600 Oil & Gas Panel Pressure Transmitter 00825-0100-4022, Rev GA NOTICE NOTICE This guide provides basic guidelines for the Rosemount 4600 Oil & Gas Panel Pressure Transmitter. It does not provide
More informationRION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer Product Brochure & Data Sheet Headquarters: Phoenix, Arizona 20100, N 51st Ave, Suite
More informationInstruction Manual. Model No and Self-Leveling Cross-Line Laser Level
Self-Leveling Cross-Line Laser Level Model No. 40-6620 and 40-6625 Instruction Manual Congratulations on your choice of this Self-Leveling Cross-Line Laser Level. We suggest you read this instruction manual
More informationPQS performance specification
PQS performance specification WHO/PQS/E006/TH06.2 Original: English Distribution: General TITLE: Integrated electronic thermometer, with or without alarm function, for vaccine refrigerators and freezers
More information