OP+DWDM8+1D OP+DWDM8+2D / OP+DWDM40 Fiber Optic DWDM Multiplexers and Demultiplexers

Size: px
Start display at page:

Download "OP+DWDM8+1D OP+DWDM8+2D / OP+DWDM40 Fiber Optic DWDM Multiplexers and Demultiplexers"

Transcription

1 Installation and Operation Manual OP+DWDM8+1D OP+DWDM8+2D / OP+DWDM40 Fiber Optic DWDM Multiplexers and Demultiplexers Edition A Delivering the Moment

2 Publication Information 2014 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal. This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product. Trademarks 6800+, ADC, CCS Navigator, Channel ONE, ChannelView, ClipSync, Delay, D Series, D Series DSX, Deliver the Moment, Delivering the Moment, FAME, Farad, G8, G Scribe, HView, IconMaster, IconLogo, IconStation, IconKey, InfoCaster, InfoCaster Creator, InfoCaster Manager, InfoCaster Player, InstantOnline, Invenio, Live Update, mcapture, Magellan, Magellan CCS Navigator, Magellan Q SEE, MultiService SDN, NetPlus, NetVX, NewsForce, Nexio G8, Nexio AMP ChannelView, Nexio Channel ONE, Nexio ClipSync, Nexio Delay, Nexio Digital Turnaround Processor, Nexio Farad, Nexio G Scribe, Nexio IconKey, Nexio IconLogo, Nexio IconMaster, Nexio IconStation, Nexio InfoCaster, Nexio InfoCaster Creator, Nexio InfoCaster Manager, Nexio InfoCaster Player, Nexio InfoCaster Traffic, Nexio InstantOnline, Nexio mcapture, Nexio News- Force, Nexio NXIQ, Nexio Playlist, Nexio Remote, Nexio RTX Net, Nexio TitleMotion, Nexio TitleOne, Nexio Velocity ESX, Nexio Velocity PRX, Nexio Velocity XNG, Nexio Volt, OPTO+, Panacea, Platinum, Playlist, Predator II GRF, Predator II GX, Punctuate, Remote, RTX Net, QuiC, Q SEE, SD STAR, Selenio, Selenio 6800+, SelenioNext, Selenio X50, Selenio X85, Selenio X100, TitleMotion, TitleOne, Velocity ESX, Velocity PRX, Velocity XNG, Versio, Videotek SD STAR, X50, and X85 are trademarks of Imagine Communications or its subsidiaries. Altitude Express, Connectus, Enabling PersonalizedTV, ICE Broadcast System, ICE Illustrate, ICE Q algorithms, ICE- PAC, Imagine ICE, Inscriber, Inscriber Connectus, Invenio, NEO, Nexio, Nexio AMP, PersonalizedTV, Router- Works, Videotek, Videotek ASI STAR, Videotek GEN STAR, and Videotek HD STAR are registered trademarks of Imagine Communications or its subsidiaries. Microsoft and Windows are registered trademarks of Microsoft Corporation. HD BNC is a trademark of Amphenol Corporation. Some products are manufactured under license from Dolby Laboratories. Dolby and the double D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc DTS, Inc. All other trademarks and trade names are the property of their respective companies. Contact Information Imagine Communications has office locations around the world. For locations and contact information see: us/ Support Contact Information For support contact information see: Support Contacts: support/ ecustomer Portal: Imagine Communications Corp. Proprietary and Confidential

3 OP+DWDM8+1D OP+DWDM8+2D OP+DWDM40 Fiber Optic DWDM Multiplexers and Demultiplexers Installation and Operation Manual Edition A June 2009

4

5 Contents Preface Manual Information...v Unpacking/Shipping Information... vii References... viii Restriction on Hazardous Substances (RoHS) Compliance... ix Waste from Electrical and Electronic Equipment (WEEE) Compliance.x Safety Terms and Symbols... xi Chapter 1: Introduction Product Description...1 Back Modules...3 Signal Flow...4 Applications...6 Chapter 2: Installation and Operation Installing and Removing the Modules...11 Installation Overview...11 Back Module Installation...12 Front Module Installation...13 Removing Modules...14 Inspecting and Cleaning Fiber Optic Connections...15 Important Points...15 Inspection and Cleaning Procedure...17 Parameter Settings and Operation...18 Chapter 3: Specifications Wavelengths...19 Miscellaneous...21 Power Consumption...22 OP+DWDM Installation and Operation Manual Copyright , Harris Corporation iii

6 Contents Appendix A: Laser Safety Guidelines Laser Safety Precautions for Enclosed Systems Precautions for Unenclosed Systems Labels Appendix B: Communication and Control Troubleshooting Tips Overview Software Communication Problems Hardware Communication Problems Index Keywords iv OP+DWDM Installation and Operation Manual Copyright , Harris Corporation

7 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Preface Manual Information Purpose Audience Revision History This manual details the features, installation procedures, operational procedures, and specifications of the OP+DWDM Fiber Optic DWDM Multiplexers and Demultiplexers. This manual is written for engineers, technicians and operators responsible for the installation, setup, and/or operation of the OP+DWDM Fiber Optic DWDM Multiplexers and Demultiplexers. Table P-1. Manual Revision History Edition Date Revision History A June 2009 Initial release OP+DWDM Installation and Operation Manual v

8 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Preface Writing Conventions To enhance your understanding, the authors of this manual have adhered to the following text conventions: Table P-2. Manual Style and Writing Conventions Term or Convention Bold Italics CAPS Code Description Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names. Indicates addresses, the names of books or publications, and the first instances of new terms and specialized words that need emphasis. Indicates a specific key on the keyboard, such as ENTER, TAB, CTRL, ALT, or DELETE. Indicates variables or command-line entries, such as a DOS entry or something you type into a field. > Indicates the direction of navigation through a hierarchy of menus and windows. hyperlink Internet address Note Indicates a jump to another location within the electronic document or elsewhere Indicates a jump to a Web site or URL Indicates important information that helps to avoid and troubleshoot problems. Obtaining Documents Technical documents can be viewed or downloaded from our website. Alternatively, contact your Customer Service representative to request a document. vi OP+DWDM Installation and Operation Manual

9 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Preface Unpacking/Shipping Information This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble-free service. 1. Check equipment for any visible damage that may have occurred during transit. 2. Confirm that you have received all items listed on the packing list. 3. Contact your dealer if any item on the packing list is missing. 4. Contact the carrier if any item is damaged. 5. Remove all packaging material from the product and its associated components before you install the unit. In the unlikely event that your product fails to operate properly, please contact Customer Service to obtain a Return Authorization (RA) number, then send the unit back for servicing. Keep at least one set of original packaging, in the event that you need to return a product for servicing. If the original package is not available, you can supply your own packaging as long as it meets the following criteria: The packaging must be able to withstand the product s weight. The product must be held rigid within the packaging. There must be at least 2 in. (5 cm) of space between the product and the container. The corners of the product must be protected. Ship products back to us for servicing prepaid and, if possible, in the original packaging material. If the product is still within the warranty period, we will return the product prepaid after servicing. OP+DWDM Installation and Operation Manual vii

10 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Preface References ITU-T G.694.1: Spectral grids for WDM applications: DWDM wavelength grid ITU-T G.694.2: Spectral grids for WDM applications: CWDM wavelength grid ITU-T G.695: Optical interfaces for coarse wavelength division multiplexing applications ITU-T G.652: Characteristics of a Single-Mode Optical Fibre Cable IEC : Fibre optic connector interfaces - Part 4-1: Type SC connector family - Simplified receptacle SC-PC connector interfaces IEC : Detail specification for fiber optic connector type SC-PC tuned terminated to single-mode fiber type B1 IEC : Detail specification for fiber optic connector type SC-PC untuned terminated to single-mode fiber type B1 viii OP+DWDM Installation and Operation Manual

11 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Preface Restriction on Hazardous Substances (RoHS) Compliance Directive 2002/95/EC commonly known as the European Union (EU) Restriction on Hazardous Substances (RoHS) sets limits on the use of certain substances found in electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling. The Directive, which took effect on July 1, 2006, refers to the following hazardous substances: Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr-V1) Polybrominated Biphenyls (PBB) Polybrominated Diphenyl Ethers (PBDE) According to this EU Directive, all products sold in the European Union will be fully RoHS-compliant and lead-free. (See our website for more information.) Spare parts supplied for the repair and upgrade of equipment sold before July 1, 2006 are exempt from the legislation. Equipment that complies with the EU directive will be marked with a RoHS-compliant emblem, as shown in Figure P-1. Figure P-1. RoHS Compliance Emblem OP+DWDM Installation and Operation Manual ix

12 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Preface Waste from Electrical and Electronic Equipment (WEEE) Compliance The European Union (EU) Directive 2002/96/EC on Waste from Electrical and Electronic Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste products. The objective of the WEEE Directive is to assign the responsibility for the disposal of associated hazardous waste to either the producers or users of these products. As of August 13, 2005, the producers or users of these products were required to recycle electrical and electronic equipment at end of its useful life, and may not dispose of the equipment in landfills or by using other unapproved methods. (Some EU member states may have different deadlines.) In accordance with this EU Directive, companies selling electric or electronic devices in the EU will affix labels indicating that such products must be properly recycled. (See our website for more information.) Contact your local Sales representative for information on returning these products for recycling. Equipment that complies with the EU directive will be marked with a WEEE-compliant emblem, as shown in Figure P-2. Figure P-2. WEEE Compliance Emblem x OP+DWDM Installation and Operation Manual

13 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Preface Safety Terms and Symbols This product manual uses the following safety terms and symbols to identify certain conditions or practices. Table P-3. Safety Terms and Symbols WARNING: Identifies conditions or practices that can result in personal injury or loss of life high voltage is present. Uninsulated dangerous voltage within the product s enclosure may be sufficient to constitute a risk of electric shock to persons. CAUTION: Identifies conditions or practices that can result in damage to the equipment or other property. Important operating and maintenance (servicing) instructions are included in the literature accompanying the product. OP+DWDM Installation and Operation Manual xi

14 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Preface xii OP+DWDM Installation and Operation Manual

15 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1 Introduction Product Description Table 1-1. OP+DWDM Product Descriptions The OP+DWDM8 and OP+DWDM40 are Dense Wavelength Division Multiplexing (DWDM) multiplexers and demultiplexers. The 8-channel version is a modular product. The 40-channel version is a standalone 1RU frame. Both are both passive fiber devices. Product Name OP+DWDM8+1D OP+DWDM8+2D Description 8-channel optical DWDM multiplexer/demultiplexer, operating in the THz to THz group of channels (with 100 GHz spacing) 8-channel optical DWDM multiplexer/demultiplexer, operating in the THz to THz group of channels (with 100 GHz spacing) OP+DWDM40 40-channel optical DWDM multiplexer/demultiplexer in the THz to THz group of channels (with 100 GHz spacing) OP+DWDM8 The main features of the OP+DWDM8 include: Bidirectional capability Multiplexer and demultiplexer capability in one module Express port for expansion Compliance with ITU-T G standards for DWDM wavelengths OP+DWDM Installation and Operation Manual 1

16 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction OP+DWDM40 The main features of the OP+DWDM40 include: 40-channel passive mux/demux capability in a 1 RU frame Compliance with ITU-T G standards for DWDM wavelengths Multiplexer and demultiplexer capability in one frame Bidirectional capability 2 OP+DWDM Installation and Operation Manual

17 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Back Modules Chapter 1: Introduction OP+DWDM8+1D OP+DWDM8+2D COM CH nm CH nm CH nm CH nm EXP CH nm CH nm CH nm CH nm COM CH nm CH nm CH nm CH nm EXP CH nm CH nm CH nm CH nm Figure 1-1. OP+DWDM8+1D and OP+DWDM8+2D Back Modules COMMON CH21 CH23 CH25 CH27 CH29 CH22 CH24 CH26 CH28 CH30 Figure 1-2. OP+DWDM40 Back Panel, Left Corner OP+DWDM Installation and Operation Manual 3

18 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction Signal Flow Figure 1-3. OP+DWDM8 Signal Flow Diagram 4 OP+DWDM Installation and Operation Manual

19 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction Common Ch39 Ch39 Ch40 Ch40 Ch41 Ch41 Ch42 Ch42 Red/Blue WDM_02 Ch51 Ch51 Ch29 Ch29 Ch52 Ch52 Ch30 Ch30 Red/Blue WDM_03 Ch53 Ch53 Red/Blue WDM_04 Ch31 Ch31 Ch43 Ch43 Ch54 Ch54 Ch21 Ch21 Ch32 Ch32 Ch44 Ch44 Ch55 Ch55 Ch22 Ch22 Ch33 Ch33 Ch45 Ch45 Ch56 Ch56 Ch23 Ch23 Ch34 Ch34 Ch46 Ch46 Ch57 Ch57 Ch24 Ch24 Ch35 Ch35 Ch47 Ch47 Ch58 Ch58 Ch25 Ch25 Ch36 Ch36 Ch48 Ch48 Ch59 Ch59 Ch26 Ch26 Ch37 Ch37 Ch49 Ch49 Ch60 Ch60 Ch27 Ch27 Ch38 Ch38 Ch50 Ch50 Ch28 Ch28 Figure 1-4. OP+DWDM40 Signal Flow OP+DWDM Installation and Operation Manual 5

20 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction Applications Typical applications for the OP+DWDM8 and OP+DWDM40 are shown in the following pages. Express ports on the OP+DWDM8 provide expansion capability, as shown in Figure 1-5. Bidirectional Common to Common OP+DWDM8+1D OP+DWDM8+1D 8 inputs/outputs bidirectional 8 inputs/outputs bidirectional COM CH nm CH nm CH nm CH nm EXP CH nm CH nm CH nm CH nm COM CH nm CH nm CH nm CH nm EXP CH nm CH nm CH nm CH nm OP+DWDM8+1D OP+DWDM8+1D Figure Channel Bi-directional Mux/Demux Between 2 OP+DWDM8 Modules 6 OP+DWDM Installation and Operation Manual

21 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction Bidirectional inputs/ outputs Bidirectional inputs / outputs Common to Express OPT EXPRESS IN OPT OUT 1551 nm IN 1471 nm IN 1571 nm IN 1491 nm IN 1591 nm IN 1511 nm IN 1611 nm IN 1531 nm IN OMS6800+CL8D OP+DWDM8+1D COM EXP CH nm CH nm CH nm CH nm CH nm CH nm CH nm CH nm Common to Express Bidirectional Common to Common OPT IN OPT EXPRESS OUT 1351 nm OUT 1271 nm OUT 1371 nm OUT 1291 nm OUT 1431 nm OUT 1311 nm OUT 1451 nm OUT 1331 nm OUT ODS6800+CL8D OP+DWDM8+2D COM EXP CH nm CH nm CH nm CH nm CH nm CH nm CH nm CH nm Common to Express Common to Express Bidirectional inputs / outputs Bidirectional inputs / outputs OP+DWDM8+1D OP+DWDM8+2D OP+DWDM8+2D OP+DWDM8+1D Bidirectional inputs / outputs COM CH nm CH nm CH nm CH nm EXP CH nm CH nm CH nm CH nm COM CH nm CH nm CH nm CH nm EXP CH nm CH nm CH nm CH nm Bidirectional inputs / outputs OP+DWDM8+2D OP+DWDM8+1D Figure Channel Bidirectional Mux/Demux Between CDWDM and DWDM Modules OP+DWDM Installation and Operation Manual 7

22 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction 22 channels of mux/demux 22 channels of mux/demux OP+DWDM8+2D OP+DWDM8+2D Bidirectional inputs /outputs (DWDM) COM CH nm CH nm CH nm CH nm OP+DWDM8+2D OP+DWDM8+1D EXP CH nm CH nm CH nm CH nm 1550 nm 1530 nm Bidirectional inputs/outputs OPT EXPRESS IN OPT OUT 1551 nm IN 1471 nm IN 1571 nm IN 1491 nm IN 1591 nm IN 1511 nm IN 1611 nm IN 1531 nm IN OMS6800+CU8D Bidirectional Common to Common up to 31 miles (50 kilometers) OPT IN OPT EXPRESS OUT 1351 nm OUT 1271 nm OUT 1371 nm OUT 1291 nm OUT 1431 nm OUT 1311 nm OUT 1451 nm OUT 1331 nm OUT ODS6800+CU8D Bidirectional inputs/outputs 1550 nm 1530 nm COM CH nm CH nm CH nm CH nm OP+DWDM8+2D OP+DWDM8+1D EXP CH nm CH nm CH nm CH nm Bidirectional inputs /outputs (DWDM) Bidirectional inputs /outputs (DWDM) COM CH nm CH nm CH nm CH nm EXP CH nm CH nm CH nm CH nm OP+DWDM8+1D COM EXP CH nm CH nm CH nm CH nm CH nm CH nm CH nm CH nm OP+DWDM8+1D Bidirectional inputs /outputs (DWDM) Figure Channel Bidirectional Mux/Demux System with 2 DWDM Modules Connected to 2 Channels of CWDM Modules for Wavelength Expansion 8 OP+DWDM Installation and Operation Manual

23 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction 8 bidirectional channels 48 channels Common to Express OPT EXPRESS IN OPT OUT 1551 nm IN 1471 nm IN 1571 nm IN 1491 nm IN 1591 nm IN 1511 nm IN 1611 nm IN 1531 nm IN OMS6800+CL8D Bidirectional Common to Common OPT IN OPT EXPRESS OUT 1351 nm OUT 1271 nm OUT 1371 nm OUT 1291 nm OUT 1431 nm OUT 1311 nm OUT 1451 nm OUT 1331 nm OUT ODS6800+CL8D 48 channels Common to Express 8 bidirectional channels COMMON CH21 CH23 CH25 CH27 CH29 COMMON CH21 CH23 CH25 CH27 CH29 CH22 CH24 CH26 CH28 CH30 CH22 CH24 CH26 CH28 CH30 OP+DWDM40 OP+DWDM40 40 Bidirectional channels 40 Bidirectional channels Figure Channel Mux/Demux Bidirectional CWDM and DWDM Hybrid Connection OP+DWDM Installation and Operation Manual 9

24 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 1: Introduction Common to Common CH21 CH23 CH25 CH27 CH29 CH21 CH23 CH25 CH27 CH29 COMMON COMMON CH22 CH24 CH26 CH28 CH30 CH22 CH24 CH26 CH28 CH30 OP+DWDM40 OP+DWDM40 40 Bidirectional channels 40 Bidirectional channels Figure Channel Mux/Demux Bidirectional DWDM Connections 10 OP+DWDM Installation and Operation Manual

25 Chapter 2 Installation and Operation Installing and Removing the Modules Installation Overview OP+DWDM+8 back modules have plastic caps that protect the fragile laser connections from damage. You must remove these protective covers before you make connections to the back modules (see Figure 2-1). In addition, all fiber optic connections must be inspected and cleaned before they are assembled. Carefully follow the inspection and cleaning steps described in the next pages. Additional safety information begins on page 23. CAUTION Take care to avoid touching the fiber optic connections. Thoroughly clean the connections before installation. Remove power from the frame before installing or removing back modules. OP+DWDM Installation and Operation Manual 11

26 Chapter 2: Installation and Operation Remove these protective covers after you have installed the back module. Figure 2-1. Protective Covers for Laser Connectors Back Module Installation Follow these steps to install the back module into its frame: 1. Remove a blank back plate from the frame. Do not discard the blank back plates. They may be needed for future configurations. 2. Remove the back module from the front module. CAUTION Microscopic dust or other contaminants can seriously impair or disable a fiber optic network. Observe strict cleaning procedures. Do not touch the end of the fiber. 3. Follow the inspection and cleaning procedure that begins on page Install the new back module by inserting the bottom lip into the required frame slot, and then screwing it into place. Ensure that the EMI gaskets on the right side of the back module remain in place during the installation. The EMI gaskets fit tightly. 12 OP+DWDM Installation and Operation Manual

27 Chapter 2: Installation and Operation Front Module Installation 5. Apply the adhesive label to the back module if it is supplied separately. 6. Remove the plastic caps when you are ready to make connections. 7. Inspect, and if necessary, clean the connections before you install them. OP+DWDM+8 front modules are passive, and can be installed with the power supply either turned on, or turned off. Procedure Follow these steps to install the front module after you have installed the back module: 1. Pull out the finger-release screws on the right and left side of the front panel of the frame, and then open it. 2. On the laser connections of the front module, follow the fiber cleaning instructions that begin on page 15. CAUTION Microscopic dust or other contaminants can seriously impair or disable a fiber optic network. Observe strict cleaning procedures. Do not touch the end of the fiber. 3. Ensure that your front module matches with the corresponding back module of the same name, and then slide the module into the guides on the frame floor. 4. When the module edge is flush with the guide, close the extractor handle. The module is properly seated when its edge is flush with the guide edge and the extractor handle closes. 5. Close the front panel to ensure proper frame ventilation. To prevent overheating, keep the front panel closed and all back module plate slots covered during operation. OP+DWDM Installation and Operation Manual 13

28 Chapter 2: Installation and Operation Removing Modules NOTE The removal steps provided here are similar to those outlined in your frame Installation and Operation Manual. Refer to that manual for detailed information about installing and operating a frame and its components. Front Module Back Module Follow these steps to remove a front module from a frame: 1. Pull out the finger-release screws on the right and left side of the front panel of the frame, and then open it. 2. Grasp the extractor handle on the installed module, and then pull the module out of its slot; use the handle as a lever. 3. Close the front panel to ensure proper frame ventilation. Follow these steps to remove a back module from a frame: 1. Turn off the frame. 2. Remove the front module, as described above. 3. Unscrew the top of the corresponding back module, and then tip it towards you. 4. Pull the bottom lip of the back module from its slot. 5. Reinstall a new or blank back plate in the empty slot to ensure proper frame ventilation. Reinstall the front module, and then repower the frame. 14 OP+DWDM Installation and Operation Manual

29 Inspecting and Cleaning Fiber Optic Connections Chapter 2: Installation and Operation Small amounts of microscopic dust or other contaminants can seriously impair or disable a fiber optic network. To ensure that your network operates reliably, you must carefully inspect and clean each connection when installing OPTO+ products. Table 2-1 lists some typical contaminants of a fiber optic connection. The inspection and cleaning procedure begins on page 17. Table 2-1. Typical Contaminants Contaminant Dust particle, 1 micron Dust particle, 9 microns Human hair Oil Film residues Powdery coatings Comments Can block up to 1% of the light transmission, creating a loss of 0.05 db Although microscopic, the particle can completely block the fiber core Typically 50 to 75 microns in diameter Frequently caused by touching Can accumulate from vapors or smoke Can be left behind after water or other solvents evaporate Important Points Before you begin cleaning, always inspect the fiber connections. Inspect and clean both fiber ends every time you make a connection. Keep a protective cap on unplugged fiber connectors. Do not touch the end of a fiber. Store unused protective caps in a clean resealable container, located nearby for easy access. Do not reuse cleaning tissues or swabs. Do not allow alcohol or another wet cleaning agent to dry on a fiber end. OP+DWDM Installation and Operation Manual 15

30 Chapter 2: Installation and Operation Never touch the dispenser tip of an alcohol bottle or any clean portion of a tissue or swab. Use care when handling the fiber; do not twist or pull. Keep your cleaning fluids away from open flame or spark. Figure 2-2 describes the acceptable limits of defects in a fiber connection. Scratches and dust Zone 1 (0 to 20 micron diameter) No scratches or digs are allowed Zone 2 (20 to 50 micron diameter) Maximum of 3 scratches <1.0 micron width is acceptable; Maximum 1.0 micron light dig is acceptable Zone 3 (50 to 126 micron diameter) Maximum 25 micron dig is acceptable; Maximum scratch size of 1.0 micron is acceptable Maximum 25 micron diameter dig is acceptable Figure 2-2. Fiber Optic Cross-Section 16 OP+DWDM Installation and Operation Manual

31 Chapter 2: Installation and Operation Inspection and Cleaning Procedure Inspection To inspect and clean the fibers, follow these steps: 1. Ensure the fiber is not live. WARNING Eye damage may occur if an optical instrument such as a microscope, magnifying glass, or eye loupe is used to stare at an energized fiber end. 2. Inspect the fiber endface with a fiberscope. 3. If the fiber endface is clean, return to the installation instructions on page 12 for back modules, or page 13 for front modules. If the connector is dirty, proceed to the dry cleaning instructions below. Dry Cleaning If you are using cartridge or pocket-style dry cleaning tools, follow the manufacturer s directions. If you are using lint-free wipes, follow these steps: 1. Fold the lint-free wipe four to eight times into a square, taking care to avoid touching the cleaning surface of the wipe. 2. Lightly wipe the fiber tip in the central portion of the lint-free wipe. CAUTION Do not scrub the fiber. Excessive rubbing will leave scratches. 3. Repeat the wiping action on another clean section of the wipe or a new wipe. 4. Inspect the connector again with the fiberscope. 5. If the connection is clean, return to the installation steps on page 12 for back modules, or page 13 for front modules. If the connector is still dirty, proceed to the wet cleaning instructions. OP+DWDM Installation and Operation Manual 17

32 Chapter 2: Installation and Operation Wet Cleaning Using 99.8% isopropyl alcohol and lint-free wipes, follow these steps to wet clean the fiber: 1. Fold the wipe into a square, about 4 to 8 layers thick. 2. Moisten one section of the lint-free wipe with one drop of 99.8% alcohol, ensuring that a portion of the wipe remains dry. 3. Lightly wipe the fiber end in the alcohol-moistened portion of the lint-free wipe. 4. Immediately repeat the wiping action on the dry section of the wipe, removing any residual alcohol. 5. Inspect the fiber endface again, and if necessary, repeat the wet cleaning with another clean section of the lint-free wipe. CAUTION Do not scrub the fiber. Excessive rubbing will leave scratches. 6. Dry clean any remaining residue, and then inspect the connector again. 7. If the contamination persists, repeat the dry and wet cleaning procedure until the endface is clean. If the fiber end still remains dirty after repeated cleaning attempts, call Customer Service for further instructions. If the fiber end is clean, return to the installation instructions on page 12 for back modules, or page 13 for front modules. Parameter Settings and Operation OP+DWDM+8 and OP+DWDM+40 products are completely passive and do not require any settings either at the card edge, or by using external software and hardware controls. OP+DWDM+8 modules will not appear in CCS software applications when they are installed in a frame. 18 OP+DWDM Installation and Operation Manual

33 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3 Specifications Wavelengths Table 3-1. OP+DWDM8+1D and OP+DWDM8+2D Wavelengths OP+DWDM8+1D (Red) OP+DWDM8+2D (Blue) Channel Wavelength (nm) Channel Wavelength (nm) OP+DWDM Installation and Operation Manual 19

34 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Specifications Table 3-2. OP+DWDM40 Wavelengths Channel Wavelength (nm) Channel Wavelength (nm) Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch OP+DWDM Installation and Operation Manual

35 Preliminary Contents are proprietary and confidential. Do not photocopy or Chapter 3: Specifications Miscellaneous Table 3-3. OP+DWDM8 Miscellaneous Specifications Item Operating Wavelength Range Channel Passband Specification Minimum Typical Maximum 1260~1620 nm >30 GHz Channel Insertion Loss 3.6 db Express Port Insertion Loss 0.8 db 1 Isolation (adjacent channel): DeMUX 28 db 2 Isolation (non-adjacent channel): 35 db 2 DeMUX Uniformity (pk-to-pk single-channel insertion loss variation) 1.0 db Directivity: MUX Return Loss 50 db 45 db Polarization Dependent Loss (PDL) Power Handling 25 dbm db 1 Express port passing wavelength for the blue band module (OP+DWDM8+1D) is from 1260 nm to 1540 nm and 1560 nm to 1620 nm. Express port passing wavelength for the red band module (OP+DWDM8+2D) is from 1260 nm to 1520 nm and 1540 nm to 1620 nm. 2 Measured across the 30GHz passband 3 CW light at any wavelength from 1250nm to 1650nm OP+DWDM Installation and Operation Manual 21

36 Preliminary Contents are proprietary and confidential. Do not photocopy or distribute. Chapter 3: Specifications Table 3-4. OP+DWDM40 Miscellaneous Specifications Item Operating Wavelength 0.5dB Maximum Insertion Loss Ripple in Passband Uniformity within channels (Mux or Demux) Adjacent Channel Isolation Non-Adjacent Channel Isolation Directivity Return Loss (all ports) Polarization Dependent Loss PMD Specification 1520~1564 nm 0.2 nm 4.5 db 0.5 db 2.0 db 30 db 45 db 50 db 45 db 0.3 db 0.2 ps Power Consumption OP+DWDM8 and OP+DWDM40 products are passive and do not require external power. Temperature The operating temperature for this module is 32 to 113 F (0 to 45 C). 22 OP+DWDM Installation and Operation Manual

37 Appendix A Laser Safety Guidelines Laser Safety WARNING Use of controls, adjustments, and procedures other than those specified in this document may result in hazardous laser radiation exposure. Optical fiber telecommunication systems use semiconductor laser transmitters that emit infrared light normally not visible to the human eye. Although a conventional laser produces a small beam of light, the power density is very high, and it can damage your eyes. If a beam of laser light enters the eye, the eye magnifies and focuses the energy on the retina. The energy that reaches the retina can be as much as 100,000 times more than at the cornea and, as a result, it can burn the retina. Laser transmission products are classified in four major groups (Class 1, 2, 3, and 4), according to their emissions and potential for causing injury. Most fiber optic transmitter modules in the OPTO+ series are designated Class 1. However, laser radiations at the MUX output of the OP+DWDM+8 and OP+DWDM+40 may exceed Laser Class 1 limits, but will not exceed Laser Class 1M limits. Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. OP+DWDM Installation and Operation Manual 23

38 Appendix A: Laser Safety Guidelines Precautions for Enclosed Systems In its normal operating mode, an optical fiber communication system is totally enclosed and presents no risk of eye injury. However, if the fiber optic cables disconnect or break, you may be exposed to laser emissions. Also, technicians may be exposed to laser emissions during installation and servicing. Unlike some other laser designs, semiconductor lasers have a highly divergent beam that decreases rapidly with distance. The greater the distance, the less energy will enter the eye, and the less potential risk for eye injury. Under normal operating conditions, optical fiber telecommunication systems are completely enclosed; nonetheless, observe the following precautions: 1. Do not stare into optical connectors or broken fibers. 2. Ensure technicians have satisfactorily completed an approved training course before performing installation or maintenance. 3. Ensure there are appropriate warning labels near the optical ports of the modules. Precautions for Unenclosed Systems WARNING Eye damage may occur if an optical instrument such as a microscope, magnifying glass, or eye loupe is used to stare at the energized fiber end. During service, maintenance, or restoration, an optical fiber telecommunication system is considered unenclosed. Under these conditions, follow these practices: CAUTION Only authorized, trained personnel shall be permitted to do service, maintenance, and restoration. 1. Avoid exposing the eye to emissions from unterminated, energized optical connectors at close distances. 2. Ensure that only authorized, trained personnel use optical test equipment during installation or servicing. 24 OP+DWDM Installation and Operation Manual

39 Appendix A: Laser Safety Guidelines 3. Turn off all laser sources before scanning a fiber with an optical test set. 4. Keep all unauthorized personnel away from the immediate area of the optical fiber systems during installation and service. For guidance on the safe use of optical fiber communication systems in the workplace, consult ANSI Z136.2, American National Standard for Safe Use of Lasers in the United States. Outside the United States, consult IEC-60825, Part 2. Labels OP+DWDM+8 and OP+DWDM+40 products by themselves are passive, and are not sources of light. However, as these products are light transmission media, you must follow proper safety practices. Laser radiation at the MUX output of the OP+DWDM+8 and OP+DWDM+40 may exceed Laser Class 1 limits, but will not exceed Laser Class 1M limits. Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. The label shown in Figure A-1 is applicable to the OP+DWDM+8 and OP+DWDM+40 products. INVISIBLE LASER RADIATION DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 1M LASER PRODUCT Figure A-1. Label for Class 1M Laser Products OP+DWDM Installation and Operation Manual 25

40 Appendix A: Laser Safety Guidelines 26 OP+DWDM Installation and Operation Manual

41 Appendix B Communication and Control Troubleshooting Tips Overview Find the following troubleshooting information in this appendix: Software Communication Problems on page 28 Hardware Communication Problems on page 31 OP+DWDM Installation and Operation Manual 27

42 Appendix B: Communication and Control Troubleshooting Tips Software Communication Problems The frame is powered up, but the module does not communicate with + Pilot Lite or CCS Pilot/Navigator. Solutions Ensure you have specified the proper module slot. See your FR6802+ Frame Installation and Operation Manual for more information about slot identification. Verify whether there is an ICE6800+ or 6800+ETH module installed in the frame. FR6802+ frames only use ICE6800+ modules to communicate with CCS software and hardware. FR6802+QXF frames use ICE6800+ or 6800+ETH modules to communicate with CCS software and hardware. Remove any legacy 6800 series product that is in the frame. + Pilot Lite and CCS software cannot communicate with legacy 6800 series products, even though these modules may operate with card-edge controls in an FR6802+ frame. Legacy 6800 products do not have the + symbol on their extractor handles. Check for bent pins on the back module by following this procedure: a. Unplug the front module. b. Unscrew and remove the back module. c. Inspect the 20- or 30-pin spring connector at the bottom of the back module (Figure B-1 on page 29), and verify that the connector does not have any slightly bent or pressed pins. d. Carefully reposition any bent pins; If this is not possible, contact Customer Support. 28 OP+DWDM Installation and Operation Manual

43 Appendix B: Communication and Control Troubleshooting Tips Figure B-1. Typical Back Module Spring Connector The frame is powered up, but + Pilot Lite does not communicate with the module. Solutions Ensure you have installed the correct cables between the PC and the frame: A null modem serial cable must be used between a PC and an FR6802+ frame (not a straight-through cable). At minimum, this requires that pins 2 and 3 are crossed, but pin 5 (ground) is straight-through to pin 5. A USB cable must be used between a PC and an FR6802+QXF frame. Verify whether there is an ICE6800+ or 6800+ETH module installed in the frame. + Pilot Lite control is disabled if an ICE6800+ or 6800+ETH control module is installed in the frame. Set the Frame ID DIP switch settings correctly (the Frame ID DIP switch is located at the rear of the frame.) If only one frame is connected, set the DIP switch to 00. If multiple frames are used in a daisy-chain, set the DIP switch numbers consecutively to the following: OP+DWDM Installation and Operation Manual 29

44 Appendix B: Communication and Control Troubleshooting Tips 00 (frame 1) 01 (frame 2) 10 (frame 3 11 (frame 4) See your FR6802+ Frame Installation and Operation Manual for more information about frame ID switch settings. Check that the correct COM port is configured in + Pilot Lite and that another application is not using that COM port. + Pilot Lite and CCS software see the frame, but do not find all of the modules Solutions Remove any legacy 6800 series products. Plug your modules in before starting the discovery. Start your discovery after the frame and all modules have fully powered up. Refresh + Pilot Lite (File > Refresh), and ensure that the installed modules are fully powered up first before discovery. + Pilot Lite and CCS Pilot/Navigator do not respond after they have been launched. Solution Close either + Pilot Lite or CCS Pilot/Navigator. Both programs cannot be running at the same time on the same PC. + Pilot Lite and CCS software show a module in the control window, but cannot control it. Solution 1. Set the module s Local/Remote jumper to Remote. 2. Ensure the module name in the Control window matches the module type in the frame. 3. Gently push the module into its slot in the frame to ensure it is seated properly and powered up. 4. Verify that the Control window indicates the device is ready. 30 OP+DWDM Installation and Operation Manual

45 Appendix B: Communication and Control Troubleshooting Tips Hardware Communication Problems After a power failure, the frames and PC do not communicate. Solution 1. Wait four minutes for the frames to recover from the power failure. 2. Close the + Pilot Lite or CCS software, and then restart the PC. 3. Restart the software application. The module does not seem to work. Solutions Ensure the correct frame is powered up. Verify that all appropriate rear connections are secure. Gently push the module into its slot in the frame to ensure it is seated properly. Ensure the back module does not have bent pins by following this procedure: a. Unplug the front module. b. Unscrew and remove the back module. c. Inspect the spring connector at the bottom of the back module (Figure B-1), and verify the connector does not have any slightly bent or pressed pins. d. Carefully reposition any bent pins; if this is not possible, contact Customer Support. OP+DWDM Installation and Operation Manual 31

46 Appendix B: Communication and Control Troubleshooting Tips 32 OP+DWDM Installation and Operation Manual

47 Index Keywords A Applications 6 10 B Back modules 3, 12 C Cap removal CCS application troubleshooting CCS software applications 18 Cleaning and inspecting fiber optics Cross-section of optical fiber 16 D Dry cleaning 17 F Features OP+DWDM40 2 OP+DWDM8 1 I Inspecting and cleaning fiber connections Installing and removing modules L Laser safety guidelines M Manual information audience v purpose v revision history v writing conventions vi Miscellaneous specifications Modules back 3, 12 installation O Operation of the products 18 P Parameter settings 18 Pilot Lite troubleshooting Power consumption specifications 22 R Removing modules 14 RoHS-compliance ix OP+DWDM Installation and Operation Manual 33

48 Index S Safety terms and symbols xi Shipping information vii Signal flow OP+DWDM40 5 OP+DWDM8 4 Specifications Standards RoHS compliance ix WEEE compliance x T Temperature specification 22 Troubleshooting U Unpacking information vii W Wavelengths WEEE compliance x Wet cleaning OP+DWDM Installation and Operation Manual

49

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L 9-channel CWDM multiplexer and demultiplexer / multi mode (-M) / -low-loss (-L) User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway

More information

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion. 18 channel CWDM mux/demux User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1:

More information

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM Rev. 0 USER MANUAL WDM-D15xx.xx Single Wavelength Add/Drop Module for DWDM Network Electronics ASA Thorøya 3204 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 e-mail: support@network-electronics.com

More information

Wideband Optical Couplers

Wideband Optical Couplers Flashlink User Manual WOC-2-50-50 WOC-2-90-10 WOC-2-95-05 WOC-4-25 Wideband Optical Couplers network-electronics.com Rev. 3 Network Electronics ASA Thorøya P.O. Box 1020 N-3204 Sandefjord, Norway Phone:

More information

ETH1000-MKII. User manual

ETH1000-MKII. User manual ETH1000-MKII Gigabit Ethernet Media Converter User manual Rev. 1 1 Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion

More information

ETH1000-D. User manual

ETH1000-D. User manual ETH1000-D Gigabit Ethernet Media Converter with DWDM laser User manual Rev. 2 Nevion Europe P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www. Nevion Support Nevion Europe

More information

Dual SDI Optical to Electrical Converter

Dual SDI Optical to Electrical Converter Flashlink User Manual SDI-OE-2 Dual SDI Optical to Electrical Converter network-electronics.com Rev. 3 Network Electronics ASA Thorøya P.O. Box 1020 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33

More information

T3/E3 Fiber Optic Line Drivers

T3/E3 Fiber Optic Line Drivers MT618A-ST-R3 January 2004 MT619A-ST-R2 MT620AE-R2 T3/E3 Fiber Optic Line Drivers CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical

More information

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Fiber Optic Connector Cleaning and Inspection Kit Instructions Instruction Sheet 860376037 Rev E, March 2018 Fiber Optic Connector Cleaning and Inspection Kit Instructions General This instruction sheet describes the use of the CommScope Fiber Optic Connector Cleaning

More information

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS

More information

Important Safety Notice

Important Safety Notice Date: 27 th April 2015 Page 1 of 12 SPI Lasers UK Limited Safety Information High Power OEM Fibre Lasers Important Safety Notice This notice outlines important safety related information and must be read

More information

SYNRAD Laser Safety 101

SYNRAD Laser Safety 101 SYNRAD Laser Safety 101 Version 2.1 Released June 2018 SYNRAD is a registered trademark of Novanta Corporation. Novanta Corporation 2018. All Rights Reserved. No reproduction without written authorization.

More information

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD NEW OTDR GENERATION Tunable DWDM OTDR for testing through MUX/DEMUX channels to provide

More information

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Erbium-Doped Fiber Amplifier (EDFA) - MW Series Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available

More information

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015 Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical

More information

G4 Pulsed Fiber Laser

G4 Pulsed Fiber Laser G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types C1 and C2 Module type C1 - fitted with IBeam1 delivery optic Module type C2 - fitted with IBeam2 delivery optic 1 1 Preface Definition

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS Wilcom Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS Model FR2 Operating Instructions 812-655-002 January, 2002 Copyright (c) 1999 Wilcom All Rights reserved Wilcom reserves the right

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

2000W FOLDING HAIR DRYER COI0034_V3_181116 USE & CARE MANUAL www.corbyofwindsor.com SECTION 01 These instructions must be read before use These instructions are for your safety. Please read through them

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62074-1 Edition 2.0 2014-02 colour inside Fibre optic interconnecting devices and passive components Fibre optic WDM devices Part 1: Generic specification INTERNATIONAL ELECTROTECHNICAL

More information

MicrOTDR. Optical Fault Locator. User Manual

MicrOTDR. Optical Fault Locator. User Manual Optical Fault Locator Datacom Textron 11001 31 st Place West Everett, WA 98204 TEL: 425-355-0590 Toll Free: 800-468-5557 FAX: 425-290-1600 Internet: www.datacom.textron.com Warranty The MicrOTDR Optical

More information

Four channel video link For low cost video transmission

Four channel video link For low cost video transmission User Manual Four channel video link For low cost video transmission CFO First Mile series consist of fi bre optic modems which provide a high quality and losless video transmission for variety of CCTV

More information

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b) Optical Services Ltd. This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b) Meets the requirements stated in IEC 60825-1:2001

More information

Field Test Procedure for Optical Fibre Link Measurements

Field Test Procedure for Optical Fibre Link Measurements Application Notes Field Test Procedure for Optical Fibre Link Measurements Issued April 2014 Abstract After fiber optic cables are installed, spliced and terminated, they must be tested. For every fiber

More information

TFS-FS1 Optical Leakage Detector. Operation Manual

TFS-FS1 Optical Leakage Detector. Operation Manual TFS-FS1 Optical Leakage Detector Operation Manual Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed

More information

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially

More information

Best Practice Briefing

Best Practice Briefing Best Practice Briefing Fiber Optic Connector Handling, Inspection, andcleaning microwave photonic systems Expand Your RF Horizons Briefing Overview Personnel Safety & Best Practices Insertion Loss (IL)

More information

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

safety & regulatory information

safety & regulatory information safety & regulatory information Document Part Number: 338610-001 Sixth Edition June 2006 This guide provides safety and regulatory information that is compliant with U.S., Canadian, and International regulations.

More information

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014) User s Fiberprime, Inc. Portable 4-Channel Laser Source Instrument www.fiberprime.com Tel: 1-613-5964030 Email: info@fiberprime.com Fax: 1-613-8289398 Portable 4-Channel Laser Source Instrument in Small

More information

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up. PD100MF0MPx Surface Mount Type, Opaque Resin Photodiode Features 1. Compact and thin SMD package 2. Top view and side view mountable 3. Plastic mold with visible light cut-off black resin lens 4. Peak

More information

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet. Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LS-1310/1550 Service Information Sheet Introduction This Service Information Sheet provides the following service information

More information

Decon Scrubber Owner s Manual

Decon Scrubber Owner s Manual Decon Scrubber Owner s Manual Serial # TM REV0001111209 TABLE OF CONTENTS Warning 1 Operating the Decon Scrubber 2 System Placement 4 Caring for your Decon Scrubber 5 Cleaning Instructions 6 Optic Replacement

More information

Operating Instructions

Operating Instructions Operating Instructions ProVicom MT-65, MT-125 R. STAHL HMI Systems GMBH Im Gewerbegebiet Pesch 14 50767 Köln Version 1.7 Issue: 21.07.2008 R. STAHL HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc

More information

Record of Amendments. Version Date Amendment Section/page affected

Record of Amendments. Version Date Amendment Section/page affected Industry support for effective compliance BTHA Guidance on The Restriction Of The Use Of Certain Hazardous Substances In Electrical and Electronic Equipment (recast) (RoHS) Directive 2011/65/EU Comparison

More information

Product Specification

Product Specification Product Specification R9400SA UltraSpan ROPA Pump Unit 1600 mw Output Power, 3U PN: FOA-R9400SA-RPA6C-AA017 Document No.: 1215607 Revision: A00 Date: 16-Jun-14 Customer: General Product Features Fully

More information

Visit us at testo 835 Infrared and contact thermometer

Visit us at   testo 835 Infrared and contact thermometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 835 Infrared and contact thermometer Instruction manual 1. General information

More information

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially

More information

Product Specification

Product Specification Product Specification M7300CD Variable Gain EDFA, 17 dbm OP, 15-30 db Gain PN: FOA-M7300CD-EVG1C-AA002 Document No.: 1213704 Revision: A00 Date: 01-Apr-14 Customer: General Product Features Variable Gain

More information

Keysight 81663A DFB Laser Source Module

Keysight 81663A DFB Laser Source Module Keysight 81663A DFB Laser Source Module User s Guide Notices 2000-2014 Keysight Technologies No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

G4 Pulsed Fiber Laser

G4 Pulsed Fiber Laser G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types B1 and B4 Module type B1 - fitted with ILLK beam delivery optic Module type B4 - fitted with ILOC beam delivery optic 1 1 Preface

More information

Elo Touch Solutions 15.6 Widescreen E-Series RevC All-in-One Touchcomputer

Elo Touch Solutions 15.6 Widescreen E-Series RevC All-in-One Touchcomputer USER MANUAL Elo Touch Solutions 15.6 Widescreen E-Series RevC All-in-One Touchcomputer SW602266 Rev B Copyright 2017 Elo Touch Solutions, Inc. All Rights Reserved. No part of this publication may be reproduced,

More information

Model TL104 MANTL104. Test Lamp for Flame Detection

Model TL104 MANTL104. Test Lamp for Flame Detection Model TL104 Test Lamp for Flame Detection The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING MITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 240 2017 SCTE Test Procedures for Testing CWDM Systems in Cable Telecommunications Access Networks NOTICE The Society

More information

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00 OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00 Torrey Pines Scientific, Inc 2713 Loker Ave. West Carlsbad, CA 92010 Phone: 760-930-9400 Fax:

More information

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR instruction manual Ref No: NISM/EVC-P/03 Date: Jan 2010 Issue: 3 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2000 NITTAN (UK) LTD. Hipley

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

1600W WALL MOUNTED HAIR DRYER COI0016_V3_070814 USE & CARE MANUAL www.corbyofwindsor.com SECTION 01 These notes must be read before installation These instructions are for your safety. Please read through

More information

Design Manual Installation Operation Maintenance

Design Manual Installation Operation Maintenance Design Manual Installation Operation Maintenance Model FT194 UV/IR Portable Flame Detector Test Lamp 23282 Mill Creek Drive, Suite 215 Laguna Hills, CA 92653 USA +1.949.583.1857 Phone +1.949.340.3343 Fax

More information

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507 RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable Reference Guide MD-019 2014A 0507 RLH Industries, Inc. Copyright 2013 RLH Industries, Inc. All rights reserved. No part of this document may

More information

Multi-Mode Electrode pro

Multi-Mode Electrode pro Multi-Mode Electrode pro Manual 8.110.8018EN / 2015-06-30 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com Multi-Mode Electrode pro 6.1246.120

More information

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer Product Brochure & Data Sheet Headquarters: Phoenix, Arizona 20100, N 51st Ave, Suite

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide

Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide 8200-1102-10 B0 Notice Please read this manual thoroughly and save it for future use before attempting to connect or operate this

More information

Agilent 81662A and 81663A DFB Laser Source Modules User s Guide

Agilent 81662A and 81663A DFB Laser Source Modules User s Guide Agilent 81662A and 81663A DFB Laser Source Modules User s Guide Agilent Technologies Notices This document contains proprietary information that is protected by copyright. All rights are reserved. No part

More information

North Dakota State University Laser Safety

North Dakota State University Laser Safety North Dakota State University Laser Safety I. Introduction The laser represents a class of light emitting devices with unique characteristics. Some of these characteristics can result in significant hazards.

More information

Product Specification

Product Specification Product Specification R9300TH Hybrid Raman-EDFA, Dual Raman Pump PN: FOA-R9300TH-HBR3C-AA001 Document No.: 1213710 Revision:A0 0 Date: 18-May-14 Customer: General Product Features Integrated Raman and

More information

Installation Instruction Manual ILS-S

Installation Instruction Manual ILS-S Installation Instruction Manual -000 L-810(L) Solar Red LED Obstruction Light Toll Free: +1 (866) 624-8309 www.itl-llc.com Front Matter Copyright & Trademarks Copyright 2015-2016 by ITL, LLC. All rights

More information

AS/NZS ISO/IEC :2012

AS/NZS ISO/IEC :2012 AS/NZS ISO/IEC 14763.3:2012 (ISO/IEC 14763-3:2011, MOD) Australian/New Zealand Standard Telecommunications installations Implementation and operation of customer premises cabling Part 3: Testing of optical

More information

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English GigaCore RPSU Redundant power supply for GigaCore 14R and 16Xt Quick Start Guide V2.0.0 Rev1 English Table of Content Safety Instructions 3 Compliance information 4 Warranty information 5 Registration

More information

Ozone + UV Sanitation

Ozone + UV Sanitation Ozone + UV Sanitation Installation Manual 4-2177-01 Rev.C IMPORTANT SAFETY INSTRUCTIONS When installing and operating the DEL Spa Solar Eclipse, basic precautions should always be followed: READ AND FOLLOW

More information

Infrared Thermometer

Infrared Thermometer 572-2 Infrared Thermometer PN 4307046 March 2013, Rev. 1, 08/13 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their

More information

Use & Care Manual Contemporary Electric Fires

Use & Care Manual Contemporary Electric Fires Use & Care Manual Contemporary Electric Fires These instructions are for your safety. Please read through them thoroughly before use and retain for future reference. Failure to follow them could cause

More information

Owner & Operator s Manual. Table of Contents

Owner & Operator s Manual. Table of Contents Owner & Operator s Manual Model No. Voltage Frequency 908041/9495160 100-120V 50 60 Hz 9495161 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 2 Unpacking Instructions 3 General

More information

Agilent 81662A and Agilent 81663A DFB Laser Source Modules. User s Guide

Agilent 81662A and Agilent 81663A DFB Laser Source Modules. User s Guide Agilent 81662A and Agilent 81663A DFB Laser Source Modules User s Guide S1 Notices This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this

More information

Infrared Thermometer. Getting Started

Infrared Thermometer. Getting Started 572-2 Infrared Thermometer Getting Started PN 4307046 March 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their

More information

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly INTERNATIONAL STANDARD ISO 22827-1 First edition 2005-10-15 Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Part 1: Laser assembly Essais de réception pour

More information

3 Scotch Mini-Weld Adhesive System User s Manual

3 Scotch Mini-Weld Adhesive System User s Manual 3 Scotch Mini-Weld Adhesive System User s Manual The Scotch Mini-Weld Adhesive System Includes The items shown below: Contents of User s Manual Ordering Replacement Parts... 1 Important Safety Information...

More information

Operating Instructions

Operating Instructions Operating Instructions REFRIGERATOR / FREEZER COMBINATION FN-436 Code : AD51AD-1 AD51AD-1( 영 ).indd 1 2014-08-28 오후 5:29:33 Disposal of Used Electrical & Electronic Equipment The meaning of the symbol

More information

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB 92-3031 OPERATOR S MANUAL Infinity Series Ceramic CO2 Laser: Models 15XXSB www.iradionlaser.com Table of Contents Table of Contents... 2 Hazard Information... 3 Terms... 3 General Hazards... 4 Label Locations...

More information

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES LASER DIODE NX8316XC 1 310 nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION The NX8316XC is a 1 310 nm Multiple Quantum Well (MQW) structured Distributed Feed-Back (DFB) laser diode

More information

HD IR Vari-focal Dome Network Camera. Quick Start Guide. Version 1.0.0

HD IR Vari-focal Dome Network Camera. Quick Start Guide. Version 1.0.0 HD IR Vari-focal Dome Network Camera Quick Start Guide Version 1.0.0 Welcome Thank you for purchasing our network camera! This quick start guide is designed to be a reference tool for your system. Please

More information

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System FlexZone April 15, 2014 Page 1 of 14 G6DA0115-001 This document is intended to provide performance specifications

More information

MultiFix Central unit

MultiFix Central unit MultiFix Manual MultiFix Central unit 2015-09- 10 C85B5EN16 Contents CONTENTS... 2 GENERAL INFORMATION... 4 SAFETY INFORMATION... 4 DESCRIPTION OF OPERATION... 4 FUNCTIONS FOR MEASUREMENT... 4 UNPACKING...

More information

64 Max IR Thermometer

64 Max IR Thermometer 64 Max IR Thermometer Instructions PN 4861406 January 2017 2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005) RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

LASER SAFETY BARRIER

LASER SAFETY BARRIER LASER SAFETY BARRIER 5' x 6' Portable Laser Barrier No-Trip Base Design High CW and Pulsed Damage Thresholds SB5X6 All Contents Stored In Base OVERVIEW Features Portable 5' x 6' (1.5 m x 1.8 m) Barrier

More information

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver Power Distribution Unit for IP-NINJAR PDU-1209 User s Guide Ver. 1.0.0 Thank you for choosing this IDK product. To ensure the best performance of this product, please read this User s Guide fully and carefully

More information

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer OTDR - FHO5000-xxx Optical Time Domain Reflectometer FHO5000 series Optical Time Domain Reflectometer (OTDR) is the latest generation of intelligent instrument for test and detection of fiber optic communication

More information

Simplex Panel Interface Guide

Simplex Panel Interface Guide Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.

More information

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6 Title: Laser Safety Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6 PURPOSE: SCOPE: To protect University

More information

Use & Care Manual Inset Electric Fires

Use & Care Manual Inset Electric Fires Use & Care Manual Inset Electric Fires These instructions are for your safety. Please read through them thoroughly before use and retain for future reference. Failure to follow them could cause injury

More information

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English GigaCore 12 Gigabit Ethernet Switch for the entertainment industry Quick Start Guide V2.1.0 Rev5 English Table of Content Safety Instructions 3 Compliance information 4 Warranty information 5 Registration

More information

Alcatel-Lucent 1850 TRANSPORT SERVICE SWITCH 320 (TSS-320) RELEASE 2.0 SAFETY GUIDE PN 8DG08136HAAA MARCH 2008 ISSUE 1

Alcatel-Lucent 1850 TRANSPORT SERVICE SWITCH 320 (TSS-320) RELEASE 2.0 SAFETY GUIDE PN 8DG08136HAAA MARCH 2008 ISSUE 1 Alcatel-Lucent 1850 TRANSPORT SERVICE SWITCH 320 (TSS-320) RELEASE 2.0 SAFETY GUIDE PN MARCH 2008 ISSUE 1 This material is protected by the copyright laws of the United States and other countries. It may

More information

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel User manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0

More information

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING i OLM R E A D Y 2014 GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD The perfect tool for field technicians who need to seamlessly

More information

i-cube Microplate Incubator E10030

i-cube Microplate Incubator E10030 i-cube Microplate Incubator E10030 User Guide and Operating Manual Table of Contents User / Owner Responsibility 3 Receiving 4 Warnings and Cautions 5-7 General Description 8 Specifications 9 Component

More information

Operations and Safety Manual

Operations and Safety Manual Tuffy Jr. Heated Soil Extractor Operations and Safety Manual BEFORE YOU START: SAFETY OPERATION SERVICE PARTS TROUBLESHOOTING RETURN GOODS POLICY! READ and UNDERSTAND this material before operating or

More information

PURPOSE OF THE PROCEDURE

PURPOSE OF THE PROCEDURE Title: Non-Ionizing Radiation Procedure Effective Date: November 2005 Revision Date: January 13, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction Management Director Environmental

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 101 263 V1.2.1 (2004-07) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems for

More information

Rev B, 9/2/2009. Kodiak Chiller Overview

Rev B, 9/2/2009. Kodiak Chiller Overview 930-0001 Rev B, 9/2/2009 Kodiak Chiller Overview Presentation Outline Phone: 781-933-7300 Lytron Technical Support Contact Information 3 Introduction 4 Part I: Unpacking 5 Part II: Installation 7 Part

More information

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Optical Return Loss Measurement by Gregory Lietaert, Product Manager White Paper Optical Return Loss Measurement by Gregory Lietaert, Product Manager Introduction With the increasing frequency of high-speed transmission systems and DWDM deployment, optical return loss (ORL)

More information

PROCESSING UNIT II V Hz V Hz. Table of Contents

PROCESSING UNIT II V Hz V Hz. Table of Contents PROCESSING UNIT II Owner & Operator s Manual Model No. Voltage Frequency 9494800 120V 50 60 Hz 9494801 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 3 Installation Instructions

More information

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015 Tank, Heater, and Control Operation Manual 25-710-804 REV. E DATE: 04May2015 Hanson Research Corporation 9810 Variel Avenue Chatsworth, CA 91311 USA (800) 821-8165 (818) 882-7266 FAX (818) 882-9470 www.hansonresearch.com

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 100 783 V1.2.1 (2004-08) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor

More information

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS.   CO9145 V1_140812 INSET ELECTRIC FIRE WITH DOWNLIGHTS CO9145 V1_140812 USE & CARE MANUAL www.adamfires.co.uk SECTION 01 These notes must be read before installation These instructions are for your safety. Please read through

More information

IFS SFP Tranceivers User Manual

IFS SFP Tranceivers User Manual IFS SFP Tranceivers User Manual P/N 1069181 REV 02.00 ISS 22AUG11 Copyright Trademarks and patents Manufacturer 2011 UTC Fire & Security. All rights reserved. Interlogix, IFS SFP Tranceivers Brand and

More information

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0 Fisher Scientific Model 281A Vacuum Oven Installation and Operating Manual 30979 Rev. 0 Preface Models covered in this manual: Catalog numbers Models numbers Voltage 13-262-50 6288 120V 13-262-51 6289

More information

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13 Manual I SS2000 TouchScreen Installation Guide Table of Contents Foreword 0 Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4 1 Installing the... SS2000 TouchScreen

More information