Davis Besse NPP Construction

Similar documents
Speransa 2008: Round table: Nuclear and sustainable development Universitad Politecnica de Valencia \UPV - Passive safety systems -

Development of Post-Accident Monitoring System for Severe Accidents

ANNEX V. AP600 & AP1000 Westinghouse Electric, USA

MINIMUM TANK GAP. Greater of 3 or one-sixth of sum of adjacent tank diameters. one-half of sum of adjacent tank diameters 20

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 3. CONTINUOUS VENTILATION OF THE CONTAINMENT (EVR [CCVS])

CHAPTER 5 CONDENSER AND EVAPORATIVE COOLING TOWER

INTRODUCTION TO SOLAR THERMAL POWER STATIONS We shall look at some of the different methods of supplying solar energy to the power stations.

Catawba Nuclear Station Delay Coil Chemical Decon Projects

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 2. COMPONENT COOLING SYSTEM FOR THE NUCLEAR ISLAND (RRI [CCWS])

Appendix B3 System/Component Cause Codes

Chapter 11. Design of Other BOP

Series 300 VTB. Installation Instructions

Water is supplied from the discharge of the Circulating Water System to a Distribution Basin, from which the Cooling Tower Pumps take a suction.

Comanche Peak Nuclear Power Plant. Emergency Planning

COOPERATIVE PATENT CLASSIFICATION

Application of Radioactive Particle Tracking (RPT) and Densitometry for Measuring Liquid Velocity Fields and Void Fraction in Convective Boiling Flows

MUST READ PRIOR TO CONSTRUCTION!

Appendix B9 Geothermal Unit Cause Codes

Borosilicate 3.3 Glass Pilot plants / Equipment

Technical Rescue Incidents

ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BOILER BALANCE OF PLANT STEAM TURBINE GENERATOR MISCELLANEOUS - GEOTHERMAL EXTERNAL

Annex A-8 CONCENTRATED SOLAR POWER UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES

What on Earth? Your Soil Health Explained

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

I&C Upgradation and Modernization at CHASNUPP 1 & 2. Presented By: Waseem Uddin Farooqi PAEC, Pakistan

Installation and Operating Service Manual

Lata Mishra Bhabha Atomic Research Centre, INDIA

Seabrook Station Condenser Tube Leaks. Jim Johnson Seabrook Station FSRUG 2017

PESIT-Bangalore South Campus

CONTENTS. B. System Design and Performance Requirements

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

SECTION PLUMBING EQUIPMENT

2016 Plumbing Supplemental Plan Review List

Industrial. Solutions brands you trust. Product Overview

Homeowners Manual. Thank you!

Choosing the Right Pump

Products for. Nuclear Power Applications

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

BASIL 6000 TUNNEL CAGE WASHER

Unit Design Data. Nuclear (Voluntary Reporting) Utility name: Station name: Unit name: Location of unit (State):

Installation, Operation, and Maintenance Information

Heat Pipe Applications Introduce

Fire-Water Bowls Model 100

GRAND EFFECTS Fire-Water Bowls Model 100

Division of Fire Safety

What Is Liquid Subcooling?

Coastal Community Convinced about Vacuum Sewers

The frequency of maintenance and service correlates with the frequency the pressure washer is used.

CRU-S Series Stainless Steel Condensate Recovery Unit

Steam and Gas Power Systems Prof. Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

The Condensate Water Systems

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK)

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

ELECTRICAL POWER SYSTEMS

I had to remove front splash shield to drain the radiator.

Fire Risks of Loviisa NPP During Shutdown States

Manufacturers Representatives Since Industrial Systems, Inc. Computer Support, Inc

10/29/01,2:16 PM TUNNEL WARM-UPPROC4--HIGHLITED REQUIRED ACTIONS.DOC KIRSNER CONSULTING ENGINEERING

InterSeptor Centrifugal Separators Operating & Maintenance Manual

ORO tank heating system

Smart Grid Tables. Exploring the Electrical Infrastructure Grades 9-12

CPVS PRODUCT DESCRIPTION

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Understanding Site Hazards

SELF-CONTAINED FLAKER

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

CPF PRODUCT DESCRIPTION

Boiler Basics. Design and operation

Case Study: Preventing Reactor Feed-water 1X Vibration by the Addition of Axial Clearance in the Rotating Assembly

TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW. Rohde, Mathias

WALTONS ULTIMATE FENCE PANEL BUYING GUIDE

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

The. Steam ONE-PIPE STEAM SYSTEMS

Hoshizaki America, Inc.

DRINKING WATER WORKS PERMIT

CHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER

(2) 325 tpd York Chlorine Liquefier Systems

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

Fire Bowls and Fire Bowl Inserts (Automated Operation) Operating and Maintenance Instructions

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

American Nuclear Society (ANS)

OWNER S MANUAL. Smoky Hill 5pc Gas Firepit Chat Set. Product Code: D71 M25973 UPC Code: Date of Purchase: / /

Filtered Containment Venting System. Proven Technology Passive Operation

BuildingName The Description of the Project P DOCUMENTS

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

Ball Corporation 140,000 Square Feet on 27 Acres Birmingham, Alabama

GOLIGHT INC. Revolutionary Lighting Solutions

CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

Air Quality Control System

Self-Guided Pumphouse Tour Welcome to the Old Hidalgo Pumphouse. We hope that this brochure will make your visit more enjoyable and meaningful, and

Safety Precautions As Related To Operating Slurry Slakers

Transcription:

Davis Besse NPP Construction Pushing Dirt and Digging Holes Actually started in 1969 below grade. When the AEC issued a Construction Permit (CP) above grade work could proceed. Below grade work was allowed without a CP with the requirement that if you bailed on the project the Site would be returned to As found condition. Planned Commercial NPP construction enjoyed a huge growth spurt in the 70s, encouraged by the optimistic load growth projections and the Atoms for Peace program. It was almost as if anyone who could write the check could buy a nuke. Orders for new Nuke Plants peaked in 1975 at ~210 projected plants. By 1978, 40% of these new plant orders had been cancelled. So it wasn t the TMI 2 Accident in 1979 that directly killed enthusiasm for NPPs. If you happened to find one for sale in the Sears and Roebuck Catalog, it came with an asterisk, Some Assembly Required. This slide show should help.

The original Licensing Basis Document was the 4 volume Preliminary Safety Analysis Report (PSAR) shown here. You couldn t get an Operating License for the plant until this document had grown in width until it expanded to 17 volumes for the Final Safety Analysis Report (FSAR). Who da thunk it, just that extra paper could triple the cost of the Plant.

The Davis Besse Plant Cooling Tower was an optional decision by the Toledo Edison Company, after all the Plant was on the shore of Lake Erie. The Cooling Tower supplier was the Research-Cottrell Company. At the time we were the northern most location for operation of a Research- Cottrell Cooling Tower, so they didn t have a lot of experience operating a tower that far north with cold winters. The concern was as the tower operated on cold windy days ice would build up on the open space at the bottom provided for the cooling air inlet. This ice build up effectively blocked the cooling air inlet flow path, thus the Main Condenser Cooling Water Temperature could increase, affecting the Main Condenser vacuum and by that Plant Generator electrical output. To offset that possibility a de-icing spray header was installed at the top of the air inlet section to redirect some warm Cooling Water to melt the ice build up. But winters can get really cold on Lake Erie, so using the de-icing header could make more ice than the local ice supplier. We found out the best thing to do was basically leave it alone and let Mother Nature naturally self-regulate the ice build up. It never affected the Main Condenser vacuum to the point of affecting the plant load output.

I started working for Toledo Edison in 1970, so I missed this initial construction work on the Cooling Tower foundation. But I did see most of it proceed, driving to work every day in Toledo.

This is a view from the direction of the lake shore by the Intake Canal at about the eventual location of the Submarine Net. During construction the canal was open to the lake for large component delivery by barge. It would later be diked off, separated by an underwater concrete pipe extending a half mile into the lake and become our Ultimate Heat Sink. The lake end of the pipe was covered with a wooden crib, complete with an air bubbler system to keep the fish away. That idea didn t work so hot either as the fish liked the air bubbles, but you could always find the crib; it was where all the fishing boats were anchored. The plant was a self-contained city, having our own water, sewer, fire protection system, emergency electrical power, etc. Since we had a semi closed loop Cooling Tower for the Main Condenser cooling, this Intake Canal was the source of water for Auxiliary Cooling Water functions, tower makeup water to replace the tower vapor plume, etc. In this view the Containment Vessel Shield Building and Cooling Tower are complete. Construction of the Turbine Building is on going. The 2 large tanks in the Turbine Building are the Condensate Storage Tanks.

Construction of the concrete Cooling Tower return water canal near the Turbine Building end.

Turbine Building support column construction.

This plant is so old that color film was just experimental. The center structure is the Turbine Building (TB) with Circ Water pipes to the Cooling Tower, and at the lower left of the TB is the start of the Intake Screen House. The structure to the left center is the Spent Fuel Pool. The Containment Vessel Shield Building shows rows of holes that will become pipe and electrical penetrations. The large hole will become the Personnel Access Hatch, the one above a Main Steam Line penetration, and the right one the Containment Purge penetration.

Circ Water Pump House showing Circ Water Pump discharge piping.

Circ Pump Suction Piping and construction of the pump pedestals.

Not positive on this, either a sluice gate for the Intake Structure or the Circ Pump House.

But this guy probably knows is that you JD?

The water distribution area in side the Cooling Tower, about 50 off the ground, is called the Fill. These concrete beams hold up the Fill. Looks like some concrete beams will be involved in Let s do it over.

Installation of water distribution baffles in the Cooling Tower.

Water distribution pipes inside the Cooling Tower above the water distribution baffles below. Note the up-sidedown umbrellas below the pipes to spread the water flow.

Sub-grade work starting on the Containment Vessel and Shield Building.

Work on the bottom of the 2 thick steel Containment Vessel container, the actual pressure boundary to atmosphere. The concrete Shield Building is a biological radiation shield and an external missile shield for the steel Containment Vessel.

Placing the bottom of the Containment Vessel, the manhole cover for the drain to China isn t installed yet (just kidding!).

Starting the rebar for the area directly under the Reactor Pressure Vessel. The circular rebar section will become the Containment Normal Sump.

The white box is the actual concrete sump where the Containment Sump Pumps will end up. You can see the rebar that will form the tunnel from the sump area to below the Reactor Vessel.

The concrete pit enclosing the Reactor Vessel is shaping up.

Containment, top still open with top steel pieces in the lay-down area. The building to the right is the Turbine Building with the Circ Pump House in its lower left corner.

Fuel Transfer Tubes with up-ender device shown. These are used to transfer fuel, under water for radiation shielding, between the Containment Refueling Canal and the Spent Fuel Pool in the Auxiliary Building.

Barge and Tugboat delivering Circ Water pipes.

Hard to guess, but since it is on the super crawler, some heavy component shored up with timbers.

Reactor Pressure Vessel. The 2 Hot Leg (outlet) nozzles are at very top and bottom. Two of the 4 Cold Leg (inlet) nozzles are the offsets. The Core Flood Low Pressure Injection nozzle is the small one.

Hey, you got the crawler keys ; nope, thought you had m. Note the 345KV switchyard.

Into the Containment Vessel.

Positioning for Polar Crane lift.

Upright, it pivots on its shipping cradle.

This is the concrete enclosure pit the Reactor Pressure Vessel will sit inside. They appear to be measuring the Hot Leg pipe outlet hole clearance. I think they re using a yardstick from Brinnon s Paint Supply; I still have mine.

Down through the Refueling Canal.

Once Through Steam Generator (SG). These were the longest lasting SGs in the US PWR industry, thanks to the efforts of Dave Briden, the original plant Chief Chemist. They made it forty years without replacement, until the 2014 refueling outage

Polar Crane Lift.

That s where it will sit

Top anchor attachments

Lower end of SG showing the lower tube sheet access manhole. The small hand holes just above are for access to the internal movable orifice plate. The 80 Hot Leg pipe to the top of the SG is to the right. The smaller nozzle on the Hot Leg is the Decay Heat drop line to the Decay Heat Removal Pump Suction.

Heat Exchanger about to go through the Turbine Building Train Bay door.

Best guess is it is the Pressurizer about to go into the Containment Vessel.

A Main Turbine Rotor Section

Intake Canal with Intake Structure Gantry Crane at upper left.

Construction of Intake Structure Screen House inlet bays. This work was done before the Intake Canal was flooded.

Access pits for pump suctions on the Plant side of the Intake Structure Traveling Screens (fish and debris strainers)

Service Water System pump suction lines in the Screen House. The gizmos are probably foot valves on the suction lines.

Not even a clue.

Mechanical Hogger (high capacity vacuum pump) for drawing a vacuum in the Main Condenser.

Booster Feed Pump end of a Main Feed Pump.

Reduction Gear, coupled a Main Feed Pump Turbine to the Main Feed Pump.

Main Generator Rotor lifted with the Turbine Building Crane.

Auxiliary Feed Pump Turbine Steam Exhaust. The white building is the Administration Office Building, proof that there was an Ivory Tower.