918TS Manual 1/26/09-1 -

Similar documents
Flopurge TS. Operation Manual

MVE TS Controller (Touch Screen)

Flostop TS D7E and A8E. Operation Manual

B-40/B-41 Modulating Temperature Controller

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Installation Instructions

TWLC - Tempered Water Logic Controller. The Intelligent Control

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

Owner's Manual TABLE OF CONTENTS

T7100D Microelectronic Conventional Thermostat

Dual Axis Inclinometer - Active

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

Model: Available in: Sapphire Black and Glacier White. 1 Series

Product Manual SZ1009

EC Series Wall Unit Humidifier

Sensor Control Panel

USER MANUAL Digital CO Monitor Model CO30

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

i-vu CCN 4.0 Owner s Guide

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

Dryer Controller M720

tcu.z Commercial Programmable Thermostat Installation Instructions

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

OVEN INDUSTRIES, INC.

MacDonald Steel Limited

APC BC300 Series 40kW 208/450/480V User Guide

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Dryer Master DM510 Commissioning Guide

1. Quick start-up guide

User Manual. Dryer Controller M720

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Follett Performance Plus

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

ELECTRONIC COMMUNICATING THERMOSTAT

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Table 1. Serie of Digital Room Thermostats.

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

THX-DL Data Logger USER & INSTALLATION MANUAL V

Model: Edge-HC. 1 edge-hc

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

T-32-TS Touchscreen Thermostat. Installation Manual

Owner's Manual TABLE OF CONTENTS

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

TC-NHP01-A, TC-NAC01-A Comfort Series Non- Programmable Thermostat. Owner s Manual

Installation Manual Premier 412/816/832. Issue 10

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

Installation Instructions

Installation Settings Guide

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Water Tank Level Monitor

SAS6000UTK-7 UNIVERSAL THERMOSTAT

Owner s Manual. Part Number 33CS250-RC

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

User Manual THR842DUK Wireless Digital Thermostat

Automatic Lamp & Mat Heating Control

Beacon 800 Gas Monitor Operator s Manual

1.1 Controller General Information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat

REDI CONTROLS, INC. Installation, Operation & Maintenance Manual

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

User's Guide. CO 2 Monitor. Model CO200

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

D A R A - 4. Data Aire Relay Auto-Changeover

Installation Instructions

Installation Settings Guide

PRO Installation. Thermostat Wi-Fi

COMFORT CONTROL. Programmable Thermostat Homeowner s Guide

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

Installation Guide. P1500W Series Air Dryer

INSTALLATION INSTRUCTIONS

Autoclave Operations Manual

Oakton TEMP 9500 Advanced Multiparameter Controller

Pioneer-R16 Gas Monitor Operator s Manual

Owner s Manual TABLE OF CONTENTS

Commercial Touchscreen Thermostat

CT224 Setup Tutorial

SUPER SEALER SUPER SEALER. PO Box 92, Avondale Heights, Victoria, Australia 3034 Phone: , Fax:

Terex Operation Manual

MANUAL. Type ETO2 Controller for ice and snow melting. Warmup Inc. The world s best-selling electric floor heating brand

Transcription:

918TS Manual 1/26/09-1 -

Table Of Contents: FEATURES...3 INSTALLATION...5 POWERING ON / INITIAL SETUP...5 SETTING DELIEVRY PRESSSURE... 7 OPTIONS & SETTINGS...8 ALARM NOTIFICATION TABLE...10-2 -

FEATURES The Auto-Logic II has many features. Each of these features is described below. Adjustable Changeover Set Points: The adjustable changeover set points are available on the home screen. The set points determine at what pressure the unit changes from the side in use to the side in standby. Manual Switch: The manual switch is a button provided to allow the system to be manually changed from the side in use to the side in standby. Local Alarm Notification: When the in use side pressure drops below the changeover set point the unit will give a visual and audible alarm. The audible alarm can be temporarily silenced using the alarm acknowledge button or permanently turned off from the parameters screen (page 8). Neither of these actions affects the dry contacts located on the top of the box. Dry Contacts: Dry contacts are provided on top of the 918TS to allow remote devices, such as alarms and auto dialers, to connect easily to the unit. The dry contacts have a rating of 120VAC at 5 amps. Leak Check System: The leak check system monitors the reserve side for leaks. If a leak is detected the system will display an alarm notification. After the leak has been corrected, the leak detected button should be pressed. Doing so will reset the leak alarm. If the leak continues and another 50% of the reserve side is lost, the leak check system will alarm again. This system can be turned on or off from the parameters screen. Delivery Pressure High/Low Alarm: When activated, this alarm will sound when the delivery line pressure goes above or below the desired offset of the set pressure. For more information please see page 8. Liquid Cylinder Gas Check: The liquid cylinder gas check is a system that ensures the most efficient withdrawal of material from dewars. When activated the Gas Check feature will monitor a depleted dewar for 1 hour to ensure that all possible product has been used. In the event the depleted dewar regains pressure within the 1 hour monitoring period, the system will return to the previously active side. If after 3

an hour it has not regained pressure the depleted side will alarm. If both dewars have gone below the changeover set points, the system will continue to flow gas unit the pressure in the dewars is 25 psig higher then the delivery set point. After which the system will stop flowing gas. As an example, if the delivery set point is 50 psig, when the dewars get below 150 psig (the changeover set point) and alarm will sound but gas will continue to flow until the dewar pressure is 75 psig. - 4 -

INSTALLATION The 918TS is provided with four mounting tabs, one in each corner, so that the unit can easily be mounted to a wall or other suitable structure. After the unit is securely mounted, the flexible pigtails (if provided) may be attached to the inlet connections at the bottom of the unit and the process piping may be connected to the outlet located on the top. Once all connections have been tightened, connect the other end of the flexible pigtails to the gas source. After the pigtails are connected, open the source valves slowly to pressurize the system. Check your connections for leaks with a suitable leak check solution. POWERING ON / INITIAL SETUP The unit may now be plugged into a 120VAC outlet. The unit will start to power up. After a moment you will see the inlet pressures, left and right changeover set points, delivery line pressure and set point (which should read zero), and other various graphical buttons. Figure 1 is a typical home screen. 3 5 4 3 9 1 2 7 8 6 1. Left side source pressure 2. Right side source pressure 3. Left/Right changeover set points 4. Set pressure 5. Delivery line pressure 6. Manual switch buttons 7. Parameter set screen 8. System information screen 9. Delivery pressure monitor screen figure 1 Once the home screen is on and the source pressures are being displayed you can adjust the default 300 psig changeover set points is desired. To do so press either the left or right changeover pressure set point button (fig. 1 button 3) to bring up the changeover set point keypad (fig. 2). 5

figure 2 It is recommended to use the following chart when setting the changeover set points. Inlet Pressure Setup Left Set Point (psig) Right Set Point (psig) Cylinders (3000 psig) on both inlets 300 300 Dewars (500 psig or less) on both inlets 150 150 Cylinder on right side Dewar on left side 150 300 Dewar on right side Cylinder on left side 300 150 6

Setting your delivery pressure: The delivery pressure for your system may now be set. It is recommended that a valve be installed immediately after the outlet of the unit. This valve should be closed before setting your delivery pressure. To set the delivery pressure, press the delivery set pressure button (fig.1 button 4) to bring up the keypad (fig.2). Enter the desired pressure, and then press enter. After a moment bleed off a small amount of gas from the delivery line to achieve an accurate line pressure reading. It may be necessary to adjust the set pressure slightly to achieve a specific line pressure. This adjustment is a normal compensation to adjust the bias at various pressures. Due to the bias adjustment it is possible the set pressure and line pressure may not match. The line pressure always shows the actual pressure going to your system. To avoid over shooting the desired delivery pressure, it is recommended to increase the pressure by increments of 25 psig. Example: If the desired delivery pressure is 100 psig, first set the line pressure to 25, then 50, then 75 and finally 100. CAUTION: Setting the delivery line pressure directly (without incrementing) may cause the delivery line pressure to over shoot (up to 25 psig more) the desired pressure. Once the delivery pressure is set, your process may now start. The initial setup for your 918TS is now complete. - 7 -

OPTIONS & SETTINGS The 918TS automatic changeover has some additional options that may be turned on or off from within the parameter screen. To access the parameters screen press the PARAM SET button (fig.1 button 7). A popup will ask for a password, this password is 1234. Then hit the enter button. The parameters screen will now be displayed see fig. 3. 1 2 3 4 5 figure 3 Turn the local alarm on/off: To turn the local alarm on or off press the ALARM ON/OFF button (fig.3 button 1) to read the desired action. Press the exit button (fig.3 button 5) to return to the home screen. Turn the leak check notifications on/off: To turn the leak check feature on or off press the LEAK CHECK ON/OFF button (fig.3 button 2) to read the desired action. Press the exit button (fig.3 button 5) to return to the home screen. Delivery Pressure High/Low Alarm 8

The delivery pressure hi/low alarm has two settings available. Either ALARM ONLY or ALARM AND SHUTDOWN (fig. 4). To turn these features on press the DELIVERY PRESSURE HIGH/LOW ALARM BUTTON (fig.3 button 3) to read the desired action. figure 4 The high and low set point may now be set. As an example if the unit is delivering 50 psi to your process and you would like to know if the line pressure goes below 45 psig, the DELIVERY PRESS LOW ALARM OFFSET would be set to 5 using the up and down buttons (fig.5 buttons 1 and 2). Once the desired offset is selected, press the exit button (fig.3 button 5) to return to the home screen. Repeat this process to set the DELIVERY PRESS HIGH ALARM OFFSET if desired. 1 2 figure 5 9

Liquid cylinder gas check: To turn the gas check feature on or off press the LIQUID CYLINDER GAS CHECK button (fig.3 button 4) to read the desired action. Press the exit button (fig.3 button 5) to return to the home screen. ALARM NOTIFICATION & TROUBLESHOOTING TABLE ALARM/PROBLEM Replace Cylinder Leak Detected No gas flowing from outlet Screen is blank Inlet pressure says liquid scale but the pressure is above 600 psi Local alarm is chirping ACTION Replace depleted side. See FEATURES (page 3) Check that the delivery set pressure is set to a number 25 or higher. Check that the power light is on and the unit is plugged in. Let the side with the error deplete its gas source, then replace cylinder as normal. The Gas Check feature is on but there are high pressure cylinders on both sides. Please turn off the Gas Check feature. 10