S T R I T T & P R I E B E I N C.

Similar documents
Overview of Hazardous Locations as They Relate to Solenoid Valves

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Guide for hazardous areas

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Hazardous area descriptions

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Specifying Temperature Sensors for Hazardous Areas

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

UL HAZARDOUS LOCATIONS SERVICES

Hazardous Area Classifications and Protections

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper. Calibration in hazardous areas

Introduction to Hazardous Electrical Location Classifications

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

ATEX, NOMENCLATURE AND CODING

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Guide to Hazardous Location Approvals:

ATEX, NOMENCLATURE AND CODING

1. GENERAL TECHNICAL INFORMATION

Explosion-proof Duct Heaters

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Explosion-protected actuator Page 259 of 292

A Guide to Safe Electronic Weighing in Hazardous Locations

Guide to Intrinsically Safe Portable Radios

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

VSD AND SS DRIVING ATEX MOTORS February 2014

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

[ TECHNOLOGY ] and does this definition affect a burner.

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Fire Alarm System Accessories

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

CLASS I LOCATIONS ZONE CLASSIFICATION

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

Fire Alarm System Accessories

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Relays for use in hazardous locations. Class I, Division 2 and ATEX

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Understanding Hazardous Locations Concepts

ATEX Safety Switches. More than safety.

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

ESSENTIAL EXPLOSION PROTECTION

Apparatus Groups are sometimes referred to, erroneously, as Gas Groups.

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Installation guide for hazardous areas

Explosion-protected network cameras Safety first

Certificate of Compliance

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

specifically for explosion prone areas can substantially reduce the risk of combustion.

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Electrical Installations Design, Selection, Erection and Inspection

EFP Series ( enhanced ) Flameproof Electrical Connectors for Hazardous Environments IP 68. Certified to: IIC

Annubar Flowmeter Series

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Implementation of ATEX Guidelines

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Certificate of Compliance

Oil & Gas Oil & Gas. Control Control. every move. Directional Control Valves & Regulators Pressure Controls Temperature Switches Level Controls

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Intrinsically Safe Solutions

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Inductive slot sensor

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

ATEX - ATmosphere EXplosive

INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Oil & Gas Oil & Gas. Control. every move. Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches

Area Classification and Types of Protection for Explosive Atmospheres: A Review

Special Occupancy Requirements

Explosion Protection in Europe

Desiccant. Breather Range

Motorola Professional Series Enhanced ATEX Portable Radios. October 2007

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Gas Detection GAS BOOK.

Dual certification! Air handling units for potentially explosive atmospheres

Today's world of increasing

Certification Supplement Manual

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

ESSENTIAL EXPLOSION PROTECTION

ATM Lighting sp. z o.o

OPTIBAR DP 7060 Supplementary Instructions

NCS/SAS IAS/PES Chapter Seminar January 25-27, Hazardous Locations. OBIEC Consulting George Morlidge Fluor Canada

Equipment and Solutions

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

Understanding Hazardous and Explosion-Protection Environments

ATM Lighting sp. z o.o

Product Guide Registered Quality System to ISO 9001:2008

Transcription:

Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure used to house electrical equipment, which when subjected to an internal explosion will not ignite a surrounding explosive atmosphere. EExd EN50018 Exd IEC60079-1 Class 1 Divisions 1 & 2 UL1203 Intrinsic Safety A technique whereby electrical energy is limited such that any sparks or heat generated by electrical equipment is sufficiently low as to not ignite an explosive atmosphere. Zones 0, 1 & 2 EExi EN50020 Exi IEC60079-11 Class 1 Divisions 1 & 2 UL913 Increased Safety This equipment is so designed as to eliminate sparks and hot surfaces capable of igniting an explosive atmosphere. EExe EN50019 Exe IEC60079-7 Purged and Pressurized Electrical equipment is housed in an enclosure which is initially purged to remove any explosive mixture, then pressurized to prevent ingress of the surrounding atmosphere prior to energization. EExp EN50016 Exp IEC60079-2 Class 1 Divisions 1 & 2 NFPA496 Encapsulation A method of exclusion of the explosive atmosphere by fully encapsulating the electrical components in an approved material. EExm EN50028 Exm IEC60079-18 Oil Immersion The electrical components are immersed in oil, thus excluding the explosive atmosphere from any sparks or hot surfaces. EExo EN50015 Exo IEC60079-6 Class 1 Division 2 UL698 Powder Filling Equipment is surrounded with a fine powder, such as quartz, which does not allow the surrounding atmosphere to come into contact with any sparks or hot surfaces. EExq EN50017 Exq IEC60079-5 Non-sparking Sparking contacts are sealed against ingress of the surrounding atmosphere, hot surfaces are eliminated. Zone 2 EExn EN50021 Zone 2 Exn IEC60079-15 Special Protection Equipment is certified for use in a Potentially Explosive Atmosphere but does not conform to a type of protection listed above. Zones 0, 1 & 2 *Exs Zones 0, 1 & 2 Exs

Certified Testing Agencies for Hazardous Location Equipment Approval Agency Used Approvals Accepted By ATEX BASEEFA British Approvals Service for Electrical European Union Equipment in Flammable Atmospheres KEMA NV tot Keuring van Elektrotehnische Materialen LCIE Laboratorie Central des Industries Electriques BASEEFA British Approvals Service for Electrical Equipment in Great Britain Flammable Atmospheres CENELEC European Committee for Electrotechnical European Union Standardization CSA Canadian Standards Association Canada FM Factory Mutual Research North America FSETAN Federal Service on Ecological, technical and Nuclear Russia Supervision GB National Safety Certification China GOST-R GOST-GOSSTANDART Russia IECEx International Electrotechnical Commission on International Explosion Protected Equipment INMETRO National Institute of Metrology, Standardization and Brazil Industrial Quality NEPSI National Supervision and Inspection Centre for China Explosion Protection and Safety of Instrumentation PTB Physikalisch-Technische Bundesanstalt Germany SAA Standards Association of Australia Australia SCS Sira Certification Service England TIIS Technology Institution of Industrial Safety Japan TIS National Product Certification Thailand UL Underwriters Laboratories North America

NEMA Enclosure Protection Standards NEMA (National Electrical Manufacturers Association) has established standards for enclosures to provide protection from environmental contamination. Descriptions of the more common standards are listed below. Type definitions are from NEMA 250-1997. NEMA Enclosure Type 2,3 Intended Use 1 Indoor use, limited amounts of falling dirt 2 Indoor use, limited amounts of falling water and dirt 3 3X 3R 3RX 3S 3SX 4 4X 5 6 6P 7 8 Outdoor use, rain, sleet, windblown dust, external formation of ice Outdoor use, rain, sleet, windblown dust, corrosion, external formation of ice Outdoor use, rain, sleet, external formation of ice Outdoor use, rain, sleet, corrosion, external formation of ice Outdoor use, rain, sleet, windblown dust, external mechanisms operable when ice laden Outdoor use, rain, sleet, windblown dust, corrosion, external mechanisms operable when ice laden Indoor or outdoor use, windblown dust and rain, splashing water, hose directed water, external formation of ice Indoor or outdoor use, windblown dust and rain, splashing water, hose directed water, corrosion, external formation of ice Indoor use, settling airborne dust, falling dirt, noncorrosive liquids Indoor or outdoor use, hose directed water, temporary submersion, external formation of ice Indoor or outdoor use, hose directed water, prolonged submersion, external formation of ice Indoor use, Class I, Division 1, Groups A, B, C, and D hazardous locations, air-break equipment (NFPA 70) Indoor use, Class I, Division 1, Groups A, B, C, and D hazardous locations, oil-immersed equipment (NFPA 70) Note: 1 Numbers can be replaced by X when the characteristic number is not required 2 Enclosure Types for US only 9 Indoor use, Class II, Division 1 Groups E, F, and G hazardous locations, air-break equipment (NFPA 70) 10 Mining applications 3 Enclosure Type can be converted to IP code rating; however, IP classified enclosures cannot be converted to Enclosure Type 11 Indoor use, oil immersed, corrosive liquids & gases 12 12K 13 Indoor use, circulating dust, falling dirt, dripping noncorrosive liquids Indoor use, circulating dust, falling dirt, dripping noncorrosive liquids, provided with knockouts Indoor use, lint, dust, spraying of water, oil, and noncorrosive coolant

STRITT PRIEBE INC. NEMA Enclosure Types Comparison of Specific Applications of NEMA Enclosures for Indoor Nonhazardous Locations Provides a Degree of Protection Against the Following Conditions Access to hazardous parts Ingress of solid foreign objects (falling dirt) Ingress of water (Dripping and light splashing) Ingress of solid foreign objects (Circulating dust, lint, fibers, and flyings **) Ingress of solid foreign objects (Settling airborne dust, lint, fibers, and flyings **) Ingress of water (Hosedown and splashing water) Oil and coolant seepage Oil or coolant spraying and splashing Corrosive agents Ingress of water (Occasional temporary submersion) Ingress of water (Occasional prolonged submersion) Type of Enclosure 1* 2* 4 4X 5 6 6P 12 12K 13 X X X X X X X X X X X X X X X X X X X X --- X X X X X X X X X --- --- X X --- X X X X X --- --- X X X X X X X X --- --- X X --- X X --- --- --- --- --- --- --- --- --- --- X X X --- --- --- --- --- --- --- --- --- X --- --- --- X --- --- X --- --- --- --- --- --- --- --- X X --- --- --- --- --- --- --- --- --- X --- --- --- * These enclosures may be ventilated. ** These fibers and flyings are nonhazardous materials and are not considered Class III type ignitable fibers or combustible flyings. For Class III type ignitable fibers or combustible flyings see the National Electrical Code, Article 500. Comparison of Specific Applications of Enclosures for Outdoor Nonhazardous Locations Type of Enclosure Provides a Degree of Protection Against the Following Conditions Access to hazardous parts Ingress of water (Rain, snow, and sleet **) Sleet *** (Windblown dust, lint, fibers, and flyings) Ingress of water (Hosedown) Corrosive agents Ingress of water (Occasional temporary submersion) Ingress of water - Occasional prolonged submersion 3 3X 3R* 3RX* 3S 3SX 4 4X 6 6P X X X X X X X X X X X X X X X X X X X X --- --- --- --- X X --- --- --- --- X X --- --- X X X X X X --- --- --- --- --- --- X X X X --- X --- X --- X --- X --- X --- --- --- --- --- --- --- --- X X --- --- --- --- --- --- --- --- --- X * These enclosures may be ventilated. ** External operating mechanisms are not required to be operable when the enclosure is ice covered. *** External operating mechanisms are operable when the enclosure is ice covered. Designed to contain an internal explosion without causing an external hazard. Designed to prevent combustion through the use of oil-immersed equipment Designed to prevent the ignition of combustible dust. Comparison of Types 7, 8, 9, 10 Enclosures In Hazardous Locations, when completely and properly installed and maintained 7 8 9 Type 7 Enclosures constructed for indoor use in hazardous (classified) locations classified as Class I, Division 1, Groups A, B, C, or D as defined in NFPA 70. Type 8 Enclosures constructed for either indoor or outdoor use in hazardous (classified) locations classified as Class I, Division 1, Groups A, B, C, and D as defined in NFPA 70. Type 9 Enclosures constructed for indoor use in hazardous (classified) locations classified as Class II, Division 1, Groups E, F, or G as defined in NFPA 70. Designed to contain an internal explosion without causing an external hazard. 10 Type 10 Enclosures constructed to meet the requirements of the Mine Safety and Health Administration, 30 CFR, Part 18. 37 Clyde Ave ~ Buffalo, New York 14215 ~ www.strittandpriebe.com 716.834.1100 1.800.274.2763 fax 716.834.1101 Sales@StrittandPriebe.com

National Electrical Code (NEC) 500 Traditional standards used in North America. Hazardous Area Descriptions Example: Class I, Div 1, Group B, C, D, T4 Permitted Class Permitted Division Permitted Group Temperature Class Permitted Class Class I: gas vapors Class II: dusts Class III: fibers Permitted Division Division 1: gasses or vapors exist under normal conditions Division 2: gasses or vapors are present but are normally contained and can escape only through accident or abnormal operation Permitted Group Group A: acetylene Group B: hydrogen or equivalents Group C: ethyl ether, ethylene or cylclopropane Group D: gasoline, hexane, naphtha, benzene, butane, propane, alcohol, acetone, benzol, lacquer, and natural gas Group E: metal dust Group F: carbon black Group G: flour, starch, grain dusts Temperature Class* T1: 450 C (842 F) T2: 300 C (572 F) T3: 200 C (392 F) T4: 135 C (275 F) T5: 100 C (212 F) T6: 85 C (185 F) * Device may be exposed to gases whose ignition temperature is higher than this value. Temperature Code Comparison A mixture of hazardous gases and air may ignite in contact with a hot surface. The condition for ignition depends on several factors as surface area, temperature and concentration of gas. Equipment approved receives a temperature code indicating the maximum surface temperature of the equipment. Classification Maximum Surface Temperature Europe USA/Canada O F O C T1 T1 842 450 T2 T2 572 300 T2A 536 280 T2B 500 260 T2C 446 230 T2D 420 215 T3 T3 392 200 T3A 356 180 T3B 329 165 T3C 320 160 T4 T4 275 135 T4A 248 120 T5 T5 212 100 T6 T6 185 85

IEC & EU (European) Standards The IEC (International Electrotechnical Commission) markings are as follows: Example: Explosion Protection Type of Protection Gas Group Classification Temperature Classification Equipment Protection Level (EPL) Hazardous Area Descriptions Ex d II B T3 Gb Equipment Protection Level (EPL) Applicable Zone Gas Ga: 0 Gb: 1 Gc: 2 Dust Da: 20 Db: 21 Dc: 22 Type of Protection d: flameproof enclosure - contain explosion and quench flame p: pressurized enclosure - fill with inert gas ia: intrinsically safe for Zone 0 - limit energy ib: Intrinsically safe for Zone 1 - limit energy o: oil immersion s: special protection e: increased safety - no arcing, sparking or hot surfaces m: encapsulation - sealed arcing devices or non-arcing q: sand-filled nl: nonincendive - limited energy na: nonincendive - non sparking me: encapsulation/increased safety Gas Group Classification IIC: acetylene and hydrogen IIB: diethel ether, ethylene, cyclopropane and others IIA: gasoline, hexane, butane, naphtha propane, isoprene and many others Temperature Class* T1: 450 C (842 F) T2: 300 C (572 F) T3: 200 C (392 F) T4: 135 C (275 F) T5: 100 C (212 F) T6: 85 C (185 F) * Device may be exposed to gases whose ignition temperature is higher than this value. ATEX Marking (94/9/EC)* European requirements centered around the safety of hazardous area equipment that became mandatory on July 1, 2003. All equipment exported into European member countries must meet the ATEX hazardous and essential health and safety requirements for acceptance. *The ATEX markings are in addition to the standard Zone markings and indicate compliance to the new directives. Equipment Group I: mines II: other than mines (surface) Example: European Community Explosion Protection Symbol Equipment Group Category Explosive Atmosphere Category 1 = Zone 0 or 20 Very High protection in area in which an explosive gas-air mixture is continuously present or present for long periods. 2 = Zone 1 or 21 High protection in area where combustible or conductive dusts are present. Area in which an explosive gas-air mixture is likely to occur in normal operation. 3 = Zone 2 or 22 Low protection in area in which an explosive gas-air mixture is not likely to occur, and if it occurs it will only exist for a short time. M1 Very High protection from Methane & Dust M2 High protection from Methane & Dust II 1 G Explosive Atmosphere G: gases/vapors D: dusts

European Ingress Protection Two numbers indicate the level of ingress protection of an instrument or apparatus. The first is the level of protection against solid objects and the second against liquids. Solids Liquids 0 No protection. 0 No protection. 1 Protected against solid objects up to 50mm, e.g. hands. 1 Protected against vertically falling drops of water. 2 Protected against solid objects up to 12mm, e.g. fingers. 2 3 Protected against solid objects up to 2.5mm, e.g. tools. 3 Protected against water spray up to 15 degrees from vertical. Protected against water spray up to 60 degrees from vertical. 4 Protected against solid objects over 1mm, e.g. wires. 4 Protected against water sprays from all directions. 5 Protected against dusts. (No harmful deposits). 5 Protected against water jets from all directions. 6 Totally protected against dust. 6 7 Protected against strong water jets from all directions, e.g. Offshore. Protected against immersion between 15cm and 1m in depth. 8 Protected against long immersion under pressure. Note: IP54 is the minimum protection allowed for Hazardous Area Equipment. European Zone Classification and Equipment Protection Level Necessary marking for the equipment according 94/9/EC according IEC 60079-0 Hazardous mixture Gas, Vapor, Mist Dust Period of presence of the flammable substances Continuously for long periods or frequently Occasional occurrence Not likely, but if it does occur only rarely and for a short period Continuously for long periods or frequently Occasional occurrence Not likely, but if it does occur only rarely and for a short period Zone classification Equipment group Category Protection group EPL Equipment protection level Protection Level Zone 0 II 1G II Ga very high Zone 1 II 2G II Gb high Zone 2 II 3G II Gc increased Zone 20 II 1D III Da very high Zone 21 II 2D III Db high Zone 22 II 3D III Dc increased Methane Mining I M1 I Ma very high Coal Dust Mining I M2 I Mb high

Hazardous Area Classification Hazardous Areas are locations where the potential for fire or explosion exists because of gases, dust, or easily ignitable fibers or flyings in the atmosphere. In North America, hazardous area classification is separated by classes, divisions, and groups to define the level of safety required for equipment installed in these locations. Classes define the general form of the flammable materials in the atmosphere. Divisions define the probability of the presence of flammable materials. Groups classify the exact flammable nature of the material. Classifications Inside North America (NEC National Electric Code) SUMMARY OF CLASS I, II, III HAZARDOUS LOCATIONS CLASSES I Gasses, Vapors and Liquids (Art. 501) II Dusts (Art. 502) GROUP A. Acetylene B. Hydrogen, etc. C. Ether, etc. D. Hydrocarbons, Fuels, Solvents, etc. E. Metal Dusts (conductive* and explosive) F. Carbon Dusts (Some are conductive* and all are explosive) G. Flour, Starch, Grain, Combustible Plastic or Chemical Dust (explosive) DIVISIONS 1 2 The substance referred to by class is present during normal conditions. Normally explosive and hazardous. Ignitable quantities of dust that is normally or may be, in suspension or conductive dust may be present. The substance referred to by class is present only in abnormal conditions, such as a container failure or system breakdown. Not normally present in an explosive concentration (but may accidentally exist). Dust not normally suspended in an ignitable concentration (but may accidentally exist). Dust layers are present. Typical Locations Petroleum refineries, and gasoline storage and dispensing areas; Dry cleaning plants where vapors from cleaning fluids can be present; Spray finishing areas; Aircraft hangars and fuel servicing areas; and Utility gas plants, and operations involving storage and handling of liquified petroleum gas or natural gas Grain elevators; Flour and feed mills; Plants that manufacture, use or store magnesium or aluminum powders; Producers of plastics, medicines and fireworks; Producers of starch or candies; Spice-grinding plants, sugar plants and cocoa plants; and Coal preparation plants and other carbon handling or processing areas III Fibers and Flyings (Art. 503) Textiles, Woodworking, etc. (easily ignitable, but not likely to be explosive) Handled or used in manufacturing. Stored or handled in storage (exclusive of manufacturing). Textile mills, cotton gins; Cotton seed mills, flax processing plants; and Plants that shape, pulverize or cut wood and create sawdust or flyings.

Classification Outside North America (ATEX) Hazardous Area Classification In Europe and countries outside of North America, classification of hazardous areas is accomplished differently. Zones are used to define the probability of the presence of flammable materials. Zone 0 Zone 1 Zone 2 Zones Area in which an explosive gas-air mixture is continuously present or present for long periods. Combustible or conductive dusts are present. Area in which an explosive gas-air mixture is likely to occur in normal operation. Area in which an explosive gas-air mixture is not likely to occur, and if it occurs it will only exist for a short time. Protection Types denote the level of safety for the device. Protection Types Zone d Flameproof (Explosion proof) Enclosure 1,2 e Increased Safety 1,2 ia Intrinsic Safety 0,1,2 ib Intrinsic Safety 1,2 o Oil Immersion 2 p Pressurized Apparatus (Purged Apparatus) 1,2 q Powder Filling (Sand Filling) 2 m Encapsulation 1,2 n Normally Nonsparking and/or Nonincendive Circuits) 2 Groups classify the exact flammable nature of the material. These groups are separated differently than North American Groups. Group I Group IIA Group IIB Group IIC Groups For application in below ground installations (mines) where methane (firedamp) and coal dust may be present. For application in above ground installation where hazards due to propane may exist. This group most closely matches the North American Group D. For application in above ground installations where hazards due to ethylene may exist. This group most closely matches the North American Group C. For application in above ground installations where hazards due to hydrogen or acetylene may exist. This group most closely matches the North American Groups A and B. Temperature Identifications convey the maximum surface temperature of the apparatus based on 104 F (40 C) ambient. These temperature codes are selected carefully not to exceed the ignition temperature of the specific gas or vapor to be encountered in the application Temperature Codes F C T1 842 450 T2 572 300 T3 392 200 T4 275 135 T5 212 100 T6 185 85