Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Similar documents
User Manual System 11

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

Owner s Manual RD432-0 Chemical Controller

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

INSTALLATION & USER MANUAL

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Universal Gas Detector

M790 ph/orp Controller. Owner s Manual

STRANTROL SYSTEM7 MECHANICAL ROOM CONTROLLER INSTALLATION, OPERATION & MAINTENANCE MANUAL

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

M770 ph Controller Owner s Manual

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Analog Room Pressure Monitor RPC Series

Carbon Monoxide Transmitter

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Installation, Operation & Maintenance Manual. Wash System

M820 ph/dual ORP Controller. Owner s Manual

1 4 DIN Dissolved Oxygen Controller

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Operation and Maintenance Manual

Operation and Maintenance Manual

Oxygen (O2) Single-Point Gas Detection System

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Powell. Fabrication & Manufacturing Inc. Hypo Batch Controller with Temperature Indicator (Digital ORP/ORP/Temperature System) 2400 Series

MODEL ORP/pH Digital Controller

Pump-Down Controller MODEL 4052

Rev B, 9/2/2009. Kodiak Chiller Overview

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Remote Display Alarm Indicator for Oxygen monitor

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

B-40/B-41 Modulating Temperature Controller

Temperature Controllers

Pump-Up Controller MODEL 4062

Water Technologies. Strantrol System 3i. Technical Guide

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

STRANTROL SET POINT CONTROLLER INSTALLATION, OPERATION & MAINTENANCE MANUAL

F4 Process Controller Installation and Operation Guide

DE20 INSTRUCTION MANUAL

Two-Channel Gas Controller

eed quality electronic design USER s MANUAL

203RE ph v 1.0 Instructions

Duct and Rough Service Carbon Monoxide Sensor

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Product waste disposal - Protection of the environment:

ph COOLING TOWER CONTROLLER

Table of Contents SECTION PAGE

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

OVEN INDUSTRIES, INC.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

KONTROL INVIKTA Double

DCM200 Aquatics Controller. Keypad Navigation

Centro-Matic Automated Lubrication Systems System Controls

D3000. Installation & Setup Guide

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Software Version 2.01 LEVEL MONITOR MODEL 220

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Snifter ATEX22 VERSION. User Manual. Distributor

TC515 and TC600 Installation Manual. a Winters company

GLD-30 Gas Leak Detector

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

JDDT1 - Single Stage Digital Thermostat

I/A Series 716C 1/16 DIN Temperature Controller

Process & TeMPerATUre UniversAl input DigiTAl MeTers

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

ORP/MILLIVOLT CONTROLLER

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

CA5000 Liquid CO 2 Freezer Backup System

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

PF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626)

Model Q45P/R. ph/orp Monitor...

Pioneer-R16 Gas Monitor Operator s Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Beacon 800 Gas Monitor Operator s Manual

Model 96VTR ¼ DIN Process Controller

Mark 25 Ultrapure Water Conductivity Analyzer

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

108A OTP1800. Grid Support. General Description

Model Q45P/R. ph/orp Monitor...

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

M920 CA & M920 CA w ph/dual ORP Controller. Owner s Manual

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Transcription:

Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4. FUNCTION... 11 4.1 OPERATION...11 4.2 MONITORING...12 4.3 CONTROL...12 4.3.1 ph, and ORP Control...12 4.3.2 Proportional Control...12 4.3.3 Consent...12 4.3.4 Pressure Switch...13 4.3.5 Manual Control...13 4.4 SAFETY ALARM...13 4.4.1 Alarm Contact...13 4.4.2 Pump On Too Long...13 4.4.3 Alarm Silence...13 4.4.4 Alarm Reset...13 4.4.5 Power ON Alarm Delay...14 4.4.6 Water Fault...14 5. INSTALLATION... 14 5.1 CONTROL PANEL...14 5.1.1 Mounting and Location...14 5.1.2 Electrical and Power...14 5.2 TERMINAL STRIP WIRING...14 5.3 SENSOR INPUT CONNECTION...15 5.4 TEMPERATURE CONTROLLER CONNECTION...15 5.4.1 Connect J Thermocouple...15 5.4.2 Terminal Description...15 5.5 PRESSURE SWITCH...16 5.6 FLOW CELL...16 5.7 CHEMICAL METERING PUMPS...17 6. MONITORED VALUES TOUCH SCREEN... 17 7. CONFIGURATION / SETUP... 17 Visit us Online at www.pulseinstrument.com 1

7.1 POWER UP...17 7.2 SET POINTS...18 7.3 TIMERS...18 7.4 CHEMICAL METERING PUMP CONTROL...18 7.4.1 Priming...18 7.4.2 Proportional Control...19 8. MAINTENANCE... 20 8.1 ELECTRODE CLEANING...20 8.2 CALIBRATION...20 8.2.1 ph Calibration...20 8.2.2 ORP Calibration...21 8.3 CHEMICAL METERING PUMP...22 8.4 SURGE SUPPRESSOR...22 9. TROUBLESHOOTING GUIDES... 23 9.1 CONTROL SYSTEM FAILED...23 9.2 SENSOR FAILED...23 9.3 SENSOR CABLE IS DAMAGED...23 9.4 SENSORS NEED MAINTENANCE...23 9.5 PH / ORP MONITOR ERROR MESSAGE...24 9.6 CHEMICAL PUMP FAILED...25 10 CONTACT... 25 Visit us Online at www.pulseinstrument.com 2

1. Overview The System 4 Monitoring and Control System is a state-of-the-art water quality monitoring and control system. It is an essential HACCP tool for wash water automation and control that allows multi-function monitoring, pump control, proportional output and recording. System 4 measures ph, ORP, and Temperature. Each of these components independently senses the current condition of the water and sends a 4-20mA signal back to the central processing unit of the system. In addition, a calculated Free Chlorine value based on clean water is displayed on the touch screen. According to the initial set point levels for the water chemistry, the system will adjust the current water chemistry automatically by turning on chemical dosing pumps. A built-in alarm system alerts to any system or process failure. User-friendly operator interface menu selection provides easy set up and password protected access to set points, timers, and parameter settings. Visit us Online at www.pulseinstrument.com 3

2. System Layout Strobe Light Water Fault Indicator Light ph Monitor Alarm and Control Indicator Lights Touch Screen ORP Monitor Alarm and Control Indicator Lights Temperature Monitor Fig. 1 Automation of Wash Water Sanitation System Diagram Visit us Online at www.pulseinstrument.com 4

Touch Screen Keypad Function Keys Fig. 2 Operator Interface (Touch Screen and Keypad) Audio Alarm Alarm Reset Momentary Switch Emergency Pull / Push Stop Switch Audio Alarm Silence Switch 3-Position Main Power Switch (ON / OFF / Manual) Fig. 3 Right Side of the Control Panel Visit us Online at www.pulseinstrument.com 5

Fig. 4 Bottom of the Control Panel BNC Connectors (Connect ph / ORP Electrodes to connector) Temperature Monitor Touch Screen Fig. 5 Back of the Front Plate inside of the Control Panel Visit us Online at www.pulseinstrument.com 6

Consent Jumper Fig. 6 Consent Inside of the Control Panel Visit us Online at www.pulseinstrument.com 7

3. Specifications Control Panel Range Resolution Accuracy Power Control Panel Dimension Enclosure Rating ph: 0.00 to 14.0 ph ORP: 0 to 1000 mv Chlorine: 0.0 to 20.00 ppm Temperature: 0.0 to 200.0 ºF ph: 0.1 ph ORP: 1 mv Chlorine: 0.01 ppm Temperature: 0.1 ºF ph: ± 0.02 ph ORP: ± 1 mv Chlorine: ± 0.1 ppm Temperature: ± 0.2% of FS 110 VAC; 15 Amps Height x Width x Depth: 20 in x 16 in x 13 in NEMA 4X Flow Cell Ports 3 Sensor Ports and 1 Sampling Port Inlet / Outlet Ports 1 1/4 NPT Sensor Ports 1/2 NPT Material PVC SCH 80 Pressure Switch Pressure Adjustable Range Tubing Length Fitting Power 100 psi Max 1.5 to 15 psi 5 feet ¼ NPT 110 VAC Chemical Pump Capacity Variable, See Pump Manual Pressure Variable, See Pump Manual Strokes per Minute 360 Max Turndown Ratio 1800:1 Stroke Length Adjustment 20% to 100% Visit us Online at www.pulseinstrument.com 8

Material IP Rating Power Variable, See Pump Manual IP 65 / IP67 115 VAC 3.1 System Components Control Panel ph Electrode ORP Electrode Temperature Flow Cell Pressure Switch Two Chemical Pumps PI1710 PI0020-PH PI0020-ORP THX-011 FC04 PS111 EW, EK, EHE Series 3.2 PLC Inputs and Outputs Pins Input Descriptions Pins Output Descriptions X0 Consent Y0 ph Acid Pump Output X1 -- Y1 -- X2 -- Y2 ORP Oxidation Pump Output X3 -- Y3 -- X4 -- Y4 -- X5 Pressure Switch Y5 -- X6 Alarm Reset Y6 General Visual Alarm X7 -- Y7 General Audio Alarm Y14 Y15 Y17 ph Alarm ORP Alarm Water Fault Channel 1 Channel 2 Channel 3 Channel 4 4-20 ma Inputs ph ORP Temperature Visit us Online at www.pulseinstrument.com 9

3.3 Function Keys See Fig. 2 Screen Name Value Set Pt. Timer K Description Displays ph, Free Chlorine, ORP, and Temperature real-time values High and low alarm limits and control set points for ph and ORP Timers for Power ON Delay, Acid Pump ON Too Long, ORP Oxidation Pump ON Too Long, Alarm Delay, and Alarm Reset Offset adjustment for the calculated Free Chlorine Value 3.4 Default Set Points and Timers See section 4.1 for detail descriptions. Setpoints Setpoint Range Adjustable Value (Default) ph Low Alarm 0 14 ph 5.0 ph ph Acid 0 14 ph 6.8 ph ph High Alarm 0 14 ph 9.0 ph ORP Low Alarm 0 1000 mv 400 mv ORP Oxidation 0 1000 mv 670 mv ORP High Alarm 0 1000 mv 900 mv Hysteresis (Dead-Band) ph Low Alarm ph Acid ph High Alarm ORP Low Alarm ORP Oxidation ORP High Alarm Fixed Value 0.1 ph 0.1 ph 0.1 ph 5 mv 5 mv 5 mv Timers Timer Range Adjustable Time (Default) On Delay 0 30 minutes 20 minutes Acid Pump On Too Long 0 30 minutes 20 minutes ORP Oxidation Pump On Too Long 0 30 minutes 20 minutes Alarm Delay 0 5 minutes 1 minute Alarm Reset 0 30 minutes 20 minutes Visit us Online at www.pulseinstrument.com 10

4. Function 4.1 Operation The system 4 provides complete automation of the water disinfection process and chemical treatment with unique capabilities for a Hands Free operation, allowing for true automation 24 hours a day. 14 HH H ph High alarm Acid Pump 1000 HH ORP High alarm Normal Operation Normal Operation L Oxid. Pump LL 0 Low alarm LL 0 Low alarm Fig. 7 ph, and ORPControl Concept ph has three set points: low alarm, acid chemical injection control, and high alarm. ORP also have three set points: low alarm, oxidizer injection control, and high alarm. ph High alarm: turns on above HH Acid pump: turns on above H Low alarm: turns on below LL ORP High alarm: turns on above HH Oxidation pump: turns on below L Low alarm: turns on below LL Visit us Online at www.pulseinstrument.com 11

Hysteresis / dead-band eliminate output chatter at the switch point (See Fig. 8). See section 3.4 for all the hysteresis (dead-band) values. SP = Setpoint Hys = Hysteresis Fig. 8 Hysteresis (Dead-band) 4.2 Monitoring This system monitors ph, ORP, and Temperature. ph is in the range of 0.0 to 14.0. ORP is in the range of 0 to 1000 mv, and temperature is in the range of 0.0 ºF to 200.0 ºF using an RTD. The touch screen (See Fig. 2) displays these values. 4.3 Control 4.3.1 ph, and ORP Control Under normal conditions, ph is controlled by the system to the desired ph value set through the touch screen by using the function keys and the keypad (see Fig. 2). When the ph rises above the high set point value, the corresponding green indicator light on the front panel (see Fig. 1) will turn ON and the acid pump will automatically turn ON via a control relay. Acid is added to the water until the ph drops down below the set point value, and the acid pump and the corresponding indicator light shut off. Under normal conditions, the ORP oxidation pump is controlled by the system to the desired ORP value set through the touch screen by using the function keys and the keypad (see Fig. 2). When the ORP value drops below the low set point value, the corresponding green indicator light on the front panel (see Fig. 1) will turn ON and the ORP oxidation pump will automatically turn ON via a control relay. The pump will add Chlorine to the water until the ORP rises to the set point value, and then the pump and the corresponding indicator light shut off. 4.3.2 Proportional Control Proportional control has the ability to increase or decrease the speed of the pump in relation to the set point value by using a 4-20 ma signal. In order to proportionally control the chemical metering pumps for acid and oxidation injection, the chemical metering pumps must be connected to the ON / OFF control outputs and to the 4-20 ma signals from the control panel. The system is able to turn ON or turn OFF the chemical metering pumps to inject chemical at the specified set point values. The 4-20 ma output signals span the ph and ORP scales, 0 14.0 ph and 0 1000 mv, respectively. See Section 7.4.2 for configuration details. 4.3.3 Consent The consent function is used to prevent acid and oxidation pumps from running at the same time, which may result in the production of harmful gases (see Fig. 6). Consent also allows for optimized use of chlorine and creates better chemical balance in the water. If the consent jumper is in place, the acid pump takes priority over the oxidation pump. Whenever the acid pump is on, the oxidation pump will never be on, even if the value of the ORP is under the set point. Visit us Online at www.pulseinstrument.com 12

Acid and oxidation pumps will run independently if the consent is off. 4.3.4 Pressure Switch If a pressure switch is connected and if there is pressure in the recirculation loop, the chemical injection will start treating the water as needed. If no pressure is detected (Water Fault), the control system will continue monitoring, but will not allow for any chemical injection or any alarms to occur. In the Water Fault condition, the alarm function is disabled, and an indicator light flashes ON / OFF. The pressure switch function allows for a 5 second confirmation in order to ignore false signaling or momentary contact. 4.3.5 Manual Control Turn the power switch located on the side of the control panel to the MAN position (see Fig. 3). The system will bypass the PLC (programmable logic controller) module. The ph, ORP, and Temperature meters (see Fig. 1) will be on to monitor the water condition. The acid and oxidation pumps will be on continuously. Use the manual control function only if the PLC fails. 4.4 Safety Alarm An alarm condition occurs due to process failure when levels of the chemicals exceed the specified alarm limits of alarm set points. Chemical pumps shut off and an audio-visual alarm is activated until reset by an operator. 4.4.1 Alarm Contact If ph or ORP reaches the alarm set point, either High or Low, the corresponding red alarm indicator light located on the front panel (See Fig. 1) will immediately start flashing, but the chemical pump(s) will continue to feed as needed. If the alarm contact is maintained for at least 2 minutes (default, adjustable, see Section 3.4), the alarm indicator light will continue flashing, the main alarm (strobe light and audio alarm) will turn ON, and all chemical pumps will turn OFF. If the alarm condition restores itself so that the alarm contact is no longer active, then the main alarm will reset itself and normal chemical dosing will be restored. 4.4.2 Pump On Too Long If the ph or ORP control point is active in the chemical feed mode for more than 20 minutes (default, adjustable, see Section 3.4), the steady corresponding red indicator light and the main alarm (strobe light and audio alarm) will turn ON and will shut OFF all pumps. 4.4.3 Alarm Silence If there is an alarm, turn the audio alarm switch on the right side of the control panel (See Fig. 3) to the OFF position to silence the alarm. Don t forget to turn ON the Audio Alarm after the problem is fixed. 4.4.4 Alarm Reset The Alarm Reset momentary switch on the right side of the control panel (See Fig. 3) will reset the main alarm (strobe and audio alarm), and restore the chemical pumps to normal operation for 20 minutes (default, adjustable, see Section 3.4). If the alarm condition continues to exist after set time, the alarm function will start again until the condition is satisfied or reset. Visit us Online at www.pulseinstrument.com 13

4.4.5 Power ON Alarm Delay This feature is activated when the control panel is supplied power (turned ON). A logic mode is activated at power on so that for the first 20 minutes (default, adjustable, see Section 3.4), all alarms are ignored and chemical feed is allowed to occur by the acid and/or oxidation pumps. 4.4.6 Water Fault If there is a Water Fault, all pumps and alarm functions are disabled, and a Water Fault indicator light on the front of the control panel (See Fig. 1) flashes ON / OFF. 5. Installation Control Panel and Electrodes preferably should be mounted as close to one another as possible and no greater than 50 feet apart (See Fig. 1). 5.1 Control Panel 5.1.1 Mounting and Location Mount the Instrument Control Panel on a secure stand, bracket, or wall by the mounting feet provided. Location of the control panel should be determined according to process layout, keeping in mind that it is preferable to locate the control panel in a dry environment, whenever possible, even though it is rated for wet environments at NEMA 4X. The control panel should be accessible for routine maintenance and easy viewing of the front digital display, as well as the visual alarm, and in hearing range of the 80 db audio alarm. It should also be located with enough space underneath of at least three feet for mounting the Injection manifold, along with the switches and cables. 5.1.2 Electrical and Power The control panel requires 110VAC at 10 Amps. The panel is supplied with a 3-prong grounded plug. Extra attached loads such as valves, mixers, and other such devices should be included in the total electrical requirements. WARNING: To reduce the risk of electrical shock, the control panel must be plugged into a grounded outlet with ratings conforming to the requirements of the control panel, and any other electrical loads connected to it. The panel should be connected to a good ground. DO NOT USE ADAPTERS! All wiring must conform to local electrical codes. 5.2 Terminal Strip Wiring From left to right 1. Acid Pump 2. Oxid. Pump 3. Neutral 4. Ground 5. Pressure Switch 6. Pressure Switch 7. (+) 4-20mA Temperature Recording 8. (-) 4-20mA Temperature Recording 9. (+) 4-20mA ph Recording 10. (-) 4-20mA ph Recording 11. (+) 4-20mA ORP Recording 12. (-) 4-20mA ORP Recording 13. (+) 4-20mA Acid Pump 14. (-) 4-20mA Acid Pump 15. (+) 4-20mA ORP Oxid. Pump 16. (-) 4-20mA ORP Oxid. Pump Terminal strip locations 1-4 are used to power the pumps. Terminal strip locations 5-6 are used for the pressure switch. Terminal strip locations 7-12 are 4-20mA output recording and terminal strip locations 13-16 are 4-20mA signals to control proportional pumps. (If not used for recording, please do not remove the jumpers.) Visit us Online at www.pulseinstrument.com 14

5.3 Sensor Input Connection Bring in the male BNC connectors of the ph and ORP probes through the two large cord grips at the bottom of the control panel (see Fig. 4) and connect each to their appropriate female BNC connectors on the ph and ORP monitors (see Fig. 5). 5.4 Temperature Controller Connection (6-13, not included) 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 5.4.1 Connect J Thermocouple Connect the positive (White wire) of the J Thermocouple to terminal 1 and the negative (Red wire) of the J Thermocouple to terminal 3 on the back of the temperature meter. 5.4.2 Terminal Description No. Description 1 Positive terminal for thermocouple 2 -- 3 Negative terminal for thermocouple 4 Power terminal (No polarity) 5 Power terminal (No polarity) (6-13, not included with the default system) 6 Normally closed terminal for Low set point output 7 Common terminal for Low set point output 8 Normally open terminal for Low set point output 9 Common terminal for GO output 10 GO output terminal 11 Normally closed terminal for High set point output 12 Common terminal for High set point output 13 Normally open terminal for Low set point output 14 Common terminal for analog output 15 Current output terminal (4-20 ma) 16 Voltage output terminal (1-5 V, 0-1 V, and 0-10 V) Visit us Online at www.pulseinstrument.com 15

5.5 Pressure Switch Pressure Switch inside the Enclosure PS111 PS111, pressure switch with NEMA 4X, is designed to make a dry contact in the event of a change in the flow followed by a change of pressure. It may be used as a flow switch. The sensitivity of the pressure switch can be adjusted by turning the dial inside of the receptacle (see picture on the right). For high pressure, reduce sensitivity and tighten the dial. For low pressure, increase sensitivity and loosen the dial. PS111 is easy to use and simple to install. Fittings, 5 feet of cable with terminal forks, along with 5 feet of tubing are provided in the package. Connection Instructions: 1. Connect wires (from 5 feet wire cable) to contact inputs (See Section 5.2). 2. Connect tubing to fitting on PS111. 3. Connect tubing end to the water pipe. 5.6 Flow Cell Flow cell allows water to enter from one end of the flow port and exit the other, while the electrodes take their measurements. Flow Cell Flow Cell Installation The pipe is in a U shape to trap water, so that the electrodes will stay wet. For some electrodes, it is essential that they stay wet at all times. Visit us Online at www.pulseinstrument.com 16

5.7 Chemical Metering Pumps Choose a clean and dry location for the pump, which is close to an electrical outlet and allows for convenient access to stroke length control, frequency control, and tubing connections. Avoid areas where ambient temperature exceeds 122 ºF (50 ºC), fall below 32 ºF (0 ºC), or where the pump or tubing would be exposed to direct sunlight (See the pump manual for details). Flooded Suction Mounting Recommended for liquids that out-gas Shelf Mount Maximum 5 feet suction lift Tank Mount Maximum 5 feet suction lift 6. Monitored Values Touch Screen The default screen on the touch screen is the Value screen (see Fig. 2). This screen will display all the monitored values: ph, ORP, and Temperature. To access this screen press the first Function key labeled Value. If the touch screen is on a screen other than the Value screen, the touch screen will revert back to the default screen in 30 seconds if no buttons are pressed. 7. Configuration / Setup 7.1 Power Up To set up a new unit, first check that the power supply connections are correct, that the outlet is 110VAC, and that the connection and power source are clean of any ground loops, inductive loads or magnetic fields. Shared loads on the same circuit may cause interference. Therefore a clean power circuit is recommended. Also, when using the AC supply, ensure that a 3-way grounded mains lead is used to connect the unit. Pull out the Pull / Push Emergency Stop switch located on the right side of the control panel (see Fig. 3). Switch on the power to the unit via the lighted ON / OFF / Manual switch that is located on the side of the control panel (See Fig. 3). The switch light should turn on the front instrument displays with indicated values on their screen. Visit us Online at www.pulseinstrument.com 17

7.2 Set Points Before we begin operations, we must first define the process parameters. Set the control and alarm set points. See Section 4.1, Fig. 7 for operation concepts and see 3.4 for default set points. 1. Press the Set Pt. Function key on the touch screen (See Fig. 2). Enter the password 2007 using the keypad. 2. Press ph button on the touch screen on the Set Points screen to change the set points for ph. 3. Press the Low Al field on the touch screen to change the Low Alarm set point and enter a value using the keypad and press the Enter button to save. 4. Repeat step 3 to change Acid and High Alarm set points. 5. Repeat Steps 1-4 to change set points for ORP. Press the corresponding button on the Set Points screen to change the set points. 7.3 Timers 1. Press the Timer function button on the touch screen to change the timer values (See Fig. 2). Enter the password 2007 using the keypad. 2. Press the Initial On Delay field to change the value using the keypad and then press the Enter button to save. See section 3.4 for default timer values and ranges. 3. Repeat step 2 to change the Acid On Too Long timer by pressing Acid On Too Long field. 4. Press NEXT button to go to the next timer screen. Change the timer values for Chlorine Oxidation Pump On Too Long and ORP Oxidation Pump On Too Long timers on the second timer screen. Repeat step 2 to change timer values. 5. Repeat step 4 to change Alarm Delay and Alarm Reset timer values on third timer screen. 7.4 Chemical Metering Pump Control EZ Series EW Series EK Series EH Series 7.4.1 Priming Normally, the pump should self prime. In order to prime the pump, set the stroke length to 100% and the frequency to 360 strokes per minute (SPM). If the pump is equipped with an air vent valve, open the knob a half turn. Liquid should move up through the suction tubing and into the pump head. When the liquid starts running through the vent side tubing, close the air vent knob and continue with output adjustment (See pump manual for details). Visit us Online at www.pulseinstrument.com 18

If the pump has no air vent valve, disconnect the discharge tubing from the injection valve. When liquid enters the discharge tubing at the pump head, stop the pump, then reconnect the discharge tubing to the injection valve. If the pump does not self prime, remove the check valve housing on the discharge and suction sides to make sure cartridges and gaskets are in correct positions. 7.4.2 Proportional Control In order to proportionally control the metering pumps for acid and oxidation injection, the chemical metering pumps must be connected to the ON/OFF control outputs and to the 4-20 ma signals from the control panel. The system panel is able to output ON/OFF control functions for metering pumps in order to inject acid and chlorine (controlled by either ORP or chlorine). The 4-20 ma output signals span the ph, Free Chlorine, and ORP scales, 0.0 14.0 ph, 0 1000 mv, and 0.00 20.00 respectively. The set points to control the pumps are entered into the system and the pumps are set to run in external analog-input mode. For example, the set point of the acid pump is entered into the control system at 6.8 ph, which means the acid pump will turn ON above 6.8 ph and turn OFF below 6.8 ph. At 6.8 ph, the control system is outputting 11.77 ma. Therefore, set the acid pump analog input range to be from 11.77 ma to 20 ma and set its pumping speed to be from 0 stroke per minute (spm) to its maximum spm, respectively. With this setup, the pumping speed of the acid pump will increase as the ph level gets higher than 6.8 ph and will slow down as it gets close to 6.8 ph. Finally, the pump will turn OFF when the ph value gets below 6.8 ph. Reference: (20-4 ma) / (14-0 ph) x (ph setpoint value) + 4 ma = ma setting of the setpoint Example 6.8 ph: (16 ma) / (14 ph) x (6.8 ph) + 4 ma = 11.77 ma 6.8 ph = 11.77 ma = 0 spm 14 ph = 20 ma = maximum spm (360 strokes) ORP works using the same principle, but is set up in the opposite direction. Its set point in the system, for example, is 670 mv. The oxidation pump analog input range would then be from 4 ma to 14.72 ma (670 mv); then the pump speed range would be from its maximum speed at 4 ma input to 0 spm at 14.72 ma input. The oxidation pump would then pump at its maximum speed at 0 mv ORP, and slow down as the ORP level gets closer to 670 mv, finally stopping when the level gets above 670 mv. With this setup, the user will be able to control the pump proportionally. Reference: (20-4 ma) / (1000-0 mv) x (ORP setpoint value) + 4 ma = ma setting of the setpoint Example 670 mv: (16 ma) / (1000 mv) x (670 mv) + 4 ma = 14.72 ma 0 mv = 4 ma = maximum spm (360 strokes) 670 mv = 14.72 ma = 0 spm Visit us Online at www.pulseinstrument.com 19

8. Maintenance 8.1 Electrode Cleaning ph, Free Chlorine, and ORP electrodes are cleaned the same way. Remove the electrodes from the manifold. Take a 1:100 diluted solution of acid to water in a cup, and place the electrode front tip in the solution at least two inches deep, for a minimum of five to fifteen minutes. Rinse the tip and re-check the calibration. 8.2 Calibration 8.2.1 ph Calibration 1. Place the ph probe in buffer solution 7.00 and allow sufficient time for the electrode to reach the buffer solution value. 2. Press and hold the CAL button for three seconds to initialize the calibration process. 3. The CAL indicator light will turn on and the top display will start blinking. The second display will show 4-7 for a few seconds. 4. The controller will automatically calibrate to the buffer solution value (ph 7.00). The first and second display will stop blinking after the controller is calibrated to ph 7.00. The second display will show - 7. Visit us Online at www.pulseinstrument.com 20

5. Rinse the electrode with water and place it in the ph 4.01 buffer solution and allow sufficient time for the electrode to reach the buffer solution value. 6. Press the ENT button. 7. The first display will start blinking and it will not stop blinking until the controller is calibrated to the buffer solution value (ph 4.01). The second display will show 4-7. 8. Press ENT to save all calibration values. Follow the same steps if you are using ph 10.00 and ph 7.00 buffer solution. 8.2.2 ORP Calibration 1. Place the ORP electrode into a known ORP standard solution (ORP-468). Press and hold the CAL button for three seconds. 2. Press the AUTO button if the ORP value is already at the standard solution value (468). Press the ENT button to start the calibration if the ORP value is NOT the standard solution value. The CAL indicator light will turn on and the SCAL on the second display will start blinking. Visit us Online at www.pulseinstrument.com 21

3. Use the UP and DOWN arrow to adjust the ORP calibration value to match the known standard solution value (468). 4. Press ENT to save the calibration value. 8.3 Chemical Metering Pump WARNING: Always wear protective clothing, face shield, safety glasses and gloves when performing any maintenance or replacement on your pump. Periodically check the chemical tank level to prevent the pump from operating without liquid. Check the pump operating condition at least every 6 months: pump head position, screws, bolts, and seals. Check more frequently if using an aggressive chemical. Also, clean the hydraulic parts, such as valves and filter, as often as needed. (See pump manual for details). 8.4 Surge Suppressor A surge suppressor is used to protect the control panel to prevent damage from loads voltage surges, spikes, and electrical line noise. The green LED on the surge suppressor indicates that the surge suppressor is working. If the green LED is off, this indicates that power is not being supplied to the surge suppressor. In addition, the LED will not illuminate if there has been a utility power failure or a short circuit. Periodically check the surge suppressor to ensure reliable system performance. Visit us Online at www.pulseinstrument.com 22

9. Troubleshooting Guides Alarm is an indication of malfunction. An alarm occurs when the ph and ORP values deviate beyond the alarm range set on the operator interface, or if it takes greater then thirty minutes to adjust the water chemistry. In the alarm mode, the strobe light is on and so is the audio horn (unless it has been turned to silence position). The chemical feed mode is immediately interrupted until the RESET button is pushed which reactivates normal operation. 9.1 Control system failed If the control system failed to work, such as pumps are not pumping when they are supposed to, you can reset the PLC to fix this problem. If resetting the PLC does not fix the problem, please contact the factory. To reset the PLC located on the back plate inside the control panel, toggle the switch to STOP (to the right), then to RUN (to the left without stopping in the middle). Finally, position the toggle switch to TERM (to the middle). 9.2 Sensor Failed Unscrew the sensors from the threaded holder and place in known calibration standards. Place the ph probe in ph 7.00 and 4.00 solutions. Place the ORP probe in 468 mv solution. The readings on the control panel should match or should be close. Follow calibration procedure. If sensors are too far off the standard readings, follow maintenance procedure as described in Section 7. 9.3 Sensor Cable is Damaged Follow the sensor cable carefully along its length and check for any cuts, breaks, or tight kinks. If the cable is damaged, replace the sensor. 9.4 Sensors Need Maintenance If other parameters seem normal but the readings seem abnormal in calibration standards, service the sensors. Take a 1:100 diluted solution of acid to water in a cup and place the sensor front tip in the solution at least 2 inches deep for a minimum of five to fifteen minutes. Follow section 8.2 for calibration. Visit us Online at www.pulseinstrument.com 23

9.5 ph / ORP Monitor Error Message The monitor s error messages are displayed on the second screen of the controller (see Fig. 1). Error Code Explanation Solution E-oF E-uF E-C1 E-C2 ph / ORP value is over the high limit. ph value is higher than 15.0 ph. ORP value is higher than 1501 mv. ph / ORP value is below the low limit. ph value is lower than 1.0 ph. ORP value is lower than -1501 mv. Electrode needs cleaning. Old standard calibration solution. Big discrepancy between the displayed value and the standard calibration solution value. E-C3 Incorrect standard calibration solution. E-t1 No temperature compensation. Check electrode connection and cable. Check the solution. Check electrode connection and cable. Check the solution. See Section 8.1 for electrode cleaning instructions. Change calibration solution. Change electrode. See Section 8.1 for electrode cleaning instructions. Change calibration solution. Change electrode. Change calibration solution. Make sure the calibration solution is ph 4, 7, or 10. Temperature sensor or resistor is missing on controller terminal 11 and 12. Replace resistor or electrode. E-t2 E-t3 E-t4 E-S1 E-S2 No temperature compensation. There is a short circuit. Temperature is over the high limit. Temperature is higher than 110ºC. Temperature is below the low limit. Temperature is lower than -10ºC. Controller system error. Loss of memory. Controller system error. Defective A/D converter. Temperature sensor or resistor is short circuit on controller terminal 11 and 12. Replace resistor or electrode. Temperature sensor or resistor connection on controller terminal 11 and 12. Do not use electrode over the temperature limit. Temperature sensor or resistor connection on controller terminal 11 and 12. Do not use electrode over the temperature limit. Contact the factory. Contact the factory. Visit us Online at www.pulseinstrument.com 24

9.6 Chemical Pump Failed Reset the control panel. If the pump receptacle has 110VAC output, but the pump is not turning on, check to make sure the pump is in the on position and at least 50% stroke and frequency. If the pump still does not turn on, the pump has failed and need service. 10 Contact Phone: (818) 909-0800 Email: support@pulseinstrument.com Web: www.pulseinstrument.com Visit us Online at www.pulseinstrument.com 25