SAIME. KaleidoSeries. 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato. Bianco Beige Avorio. Cappucino Cenere Fango.

Similar documents
Infrastructure Technology

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

Australian/New Zealand Standard

Ceram Guide to Slip Resistance Tests

Slip Resistance Tests on Coated Panels. Duram. for. Date: 4th August Your Reference Number: Document Reference Number:

Global Safe Technologies (Australia) Pty Ltd

Slip resistance testing of GRP flooring surfaces for Anglia Composites Ltd

Slips: framing the issue

Test Report to AS/NZS :2015. Report No. T160402_S

This document is a preview generated by EVS

TEST METHODS. Physico-chemical characteristics Slip resistance 1 Test methods

Slipping properties of ceramic tiles / Quantification of slip resistance

Web:

SAFETY ACTION NOTICE By arrangement with the NHSScotland Property and Environment Forum

Multi Line Laser Level Model: L203

Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants

Slip Resistant Floor Surfaces

NEUTRAL SALT SPRAY TESTING REPORT TEST RESULTS. Kim Bray Materials Testing Officer AUTHORISED SIGNATORY. Bureau Veritas

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Slips and falls. OHS Exchange FDF - Willis. better information, fewer accidents. 22 nd September

Evaluation of Slip Potentials on Bilecik Beige Marble with Pendulum Method

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

PQS Independent type-testing protocol

LABORATORY ILLUMINATED FLOTATION BATH

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

Classification of Fire Performance of Wall and Ceiling Lining Materials

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Slip resistance according to Goldilocks

Inspection Records Schedule- Fire Extinguisher

Developments in Australian Standard AS (Emergency Lighting)

PASSENGER RAIL NETWORK LIGHTING OF STATION ENVIRONMENT TO COMPLY WITH DISABILITY STANDARDS FOR ACCESSIBLE PUBLIC TRANSPORT

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

WITH OMRON E5CC CONTROL

Fire resistance test on fire collars protecting a concrete slab penetrated by services

CLASSIC 4 SLICE TOASTER 2 YEAR WARRANTY RHT14 SERIES RHT14_IB_FA_ Part No. T

Window Accessories Whitmatic

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Woven Polyester High. ACETex the proven choice for: n Embankment Support over piles. n Support over voids

RHT420_IB_FA_ Part No. T KINGSTON 2 SLICE TOASTER 2 YEAR WARRANTY RHT420 SERIES

CARE & MAINTENANCE ALUMINIUM WINDOW & DOOR SYSTEMS BY

Hinged Security Door Hardware

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Charcon British Standard kerb

CERTIFICATION SAFETY & BEYOND

Commercial Training Program

Loss Prevention Standard

Universal Pioneer Platform (Flat Pack) 42114B/42115B

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Sustainable Slip Resistance: An Opportunity for Innovation

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

SAFEGUARD RANGES SLIP RESISTANT VINYL SHEET SAFEGUARD DESIGN SAFEGUARD R10, R11, R12

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

Product Specification Qualification Test Report

BCTC CARPET TECHNICAL CENTRE

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller)

OPERATING INSTRUCTIONS FOR:

YEAR 2WARRANTY. 4 Slice Classic Toaster MODEL 9476 INSTRUCTIONS & WARRANTY 9476_IB3_111111

SAFETY TECH. RRL Pendulum Test >36 (wet test) EN Class DS Bacterial resistance

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

REASONS FOR SPECIFICATION REASONS FOR SPECIFICATION. Polysafe Ultima - heavy-duty safety flooring with enhanced slip resistance

Overhead Line Insulators

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

CHELSEA 2 SLICE TOASTER

PQS Independent type-testing protocol

TILE. Waxman Ceramics. Waxman Ceramics Ltd C O L L E C T I O N

CAN WE DEVELOP SLIP RESISTANCE METRICS THAT ENSURE APPROPRIATE TILE SELECTION?

Bringing Hydrocarbon to the Market Training & Certification

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

Hygiene cleaning equipment Keeping all equipment clean

Australian Price Book

OPPORTUNITY IS STEADILY GROWING.

South Australian Regulatory Requirements

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

Are Your Kitchen Hood Filters Compliant?

Universal Clamp Meter

HOTEL MOTEL ENGINEER ASSOCIATION

COMPLYING DEVELOPMENT CERTIFICATE APPLICATION Made under the Environmental Planning and Assessment Act 1979 Sections 85, 85A

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

REFRIGERATED RECIRCULATORY COOLER

What you need to know about Outdoor Blinds THE BUYERS GUIDE. to OUTDOOR BLINDS

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Concepts. Products. Service. DryMode Simply install tiles dry

Flat Pack - Pioneer Platform. Important!

PERFECT TOAST 2 SLICE TOASTER

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

Determination of air borne sound insulation According to ISO 140-3

PCT Workshop Before you leave the office

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATED AIR OUTLET HEATER CONTROL PANEL

Grain Drying of Malting Barley

APPROVED PANEL OF SWITCHBOARD MANUFACTURERS FOR THE SUPPLY OF LOW VOLTAGE SWITCHBOARDS

Transcription:

SAIME KaleidoSeries 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato Bianco Beige Avorio Cappucino Cenere Fango Grigio Mandorla Marone Mokka Nero

Registered Testing Authority - CSIRO 29 April 2015 Our Ref. EN13 / 2337 03/0212 TEST REPORT No. 7325.6 Requested by: Metro Tiles Pty Ltd 192 Granite Street Geebung QLD 4034 on (date): 20 March 2015 Manufacturer: Saime Product Desc.: Kaleido Series Matt Finish 300x600mm Sampling details: Where: Delivered Date: 20 March 2015 By whom: Courier How (methods): The results reported relate only to the sample(s) tested and the information received. No responsibility is taken for the accuracy of the sampling unless it is done under our own supervision. CSIRO cannot accept responsibility for deviations in the manufactured quality and performance of the product. While CSIRO takes care in preparing the reports it provides to clients, it does not warrant that the information in this particular report will be free of errors or omissions or that it will be suitable for the client's purposes. CSIRO will not be responsible for the results of any actions taken by the client or any other person on the basis of the information contained in the report or any opinions expressed in it. The reproduction of this test report is only authorised in the form of a complete photographic facsimile. Our written approval is necessary for any partial reproduction. This test report consists of 4 pages SUMMARY OF SLIP RESISTANCE TESTS PERFORMED: Result Class AS 4586:2013 Slip resistance classification of new pedestrian surface materials Appendix C: WET/BAREFOOT Ramp Mean angle of inclination: 36 C AS 4586:2013 Slip resistance classification of new pedestrian surface materials, Appendix D: OIL-WET Ramp Corrected mean overall acceptance angle: 15 R 10 In order to interpret the classifications, please refer to Standards Australia Handbook 198, An Introductory Guide to the Slip Resistance of Pedestrian Materials, which recommends minimum classifications for a wide variety of locations. It is important to realise that test results obtained on unused factory-fresh samples may not be directly applicable in service, where proprietary surface coatings, contamination, wear and subsequent cleaning all influence the behaviour of the pedestrian surface.

REPORT NO: 7325.6 Page 2 of 4 ISSUE DATE: 29 April 2015 MANUFACTURER: Saime PRODUCT DESC: Kaleido Series Matt Finish 300x600mm SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS WET/BAREFOOT RAMP TEST METHOD TEST CARRIED OUT IN ACCORDANCE WITH AS 4586:2013 (Appendix C) Test Date: 1 April 2015 Location: Slip Resistance Laboratory Test conducted by: KH, AG Sample Fixed Joint width: 0 mm structure: [ ] Smooth [ X ] Profiled [ ] Structured RESULTS Critical angle mean Reported mean Mean angle of inclination: Verification Board WB-A: 10.09 10 Verification Board WB-B: 16.36 16 Verification Board WB-C: 22.57 22 Mean angle of inclination of Test Board: 36.94 36 CLASSIFICATION: Quality Group: C

REPORT NO: 7325.6 Page 3 of 4 ISSUE DATE: 29 April 2015 MANUFACTURER: Saime PRODUCT DESC: Kaleido Series Matt Finish 300x600mm SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS OIL-WET RAMP TEST METHOD TEST CARRIED OUT IN ACCORDANCE WITH AS 4586:2013 (Appendix D) Test Date: 10 April 2015 Location: Slip Resistance Laboratory Test conducted by: KH, AG Sample Fixed Joint width: 0 mm structure: [ ] Smooth [ X ] Profiled [ ] Structured RESULTS Corrected mean overall acceptance angle: 15 Displacement space: not tested CLASSIFICATION: Slip Resistance Assessment Group: R 10 Displacement Space Assessment Group: - Test shoe used: Uvex Athletic

REPORT NO: 7325.6 Page 4 of 4 ISSUE DATE: 29 April 2015 MANUFACTURER: Saime TILE DESC: Kaleido Series Matt Finish 300x600mm Date and Place 29 April 2015, Highett, Vic Name, Title and Digital Signature: KHANH HO Technical Officer Tel: 61 3 92526119 Fax: 61 3 92526244 Email: Khanh.Ho@csiro.au PR:H300415-13:34:52

SLIPTEST AUSTRALIA PTY LTD ~ ABN 80 111 154 324 12 Blackbean Court ELANORA QLD 4221 PH 0418 75 3311 SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS AS 4586 (2013) Appendix A (Wet Pendulum Method) Report Prepared For: METRO TILES Client Address: 192 GRANITE STREET GEEBUNG QLD 4034 Project: SAIME MATT SURFACE SERIES - KAL NERO 300 X 300 Property Tested: SAIME MATT SURFACE SERIES - KAL NERO 300 X 300 Date Tested: 09.03.15 Test Report No: KO090315-10 Issue Date: 09.03.15 Testing was carried out using the Wet Test Method, using Slider 96 (Four S) rubber slider, in accordance with Australian Standard AS 4586 Appendix A Slider was conditioned/prepared using P400 abrasive paper and 3 µm lapping film Number of sites tested 5 Test location Test No. Type Gradient Degrees Type and extent of Cleaning Performed Results of last three swings British Pendulum Number Mean BPN Test Slope Correction value (SCV) Classification of Pedestrian surface materials according to the AS 4586 wet pendulum test Comments TILE 1 1 <1.5 TILE 2 2 <1.5 TILE 3 3 TILE <1.5 TILE 4 4 <1.5 TILE 5 5 <1.5 Temperature: Weather: Fine 33 o C Testing Instrument: Munro Portable Skid Tester # 1133 Calibration Date: 27.08.13 Fixed Test: Testing Officer & Signatory: Kathryn Ording Testing is performed in the anticipated direction of pedestrian travel Unfixed Test : Testing is performed in the direction of least anticipated slip resistance SA HB 198:2014 TABLE 3A MINIMUM WET PENDULUM TEST OR OIL-WET INCLINING PLATFORM CLASSIFICATIONS THAT ARE DEEMED-TO-SATISFY THE BUILDING APPLICATIONS IN THE NCC Location Pendulum / Ramp SA HB 198:2014 TABLE 3B WET PENDULUM TEST OR OIL-WET INCLINING PLATFORM CLASSIFICATIONS FOR APPLICATIONS WHERE THE NCC DOES NOT REQUIRE SLIP RESISTANCE Location Pendulum / Ramp Ramp classes A, B & C are derived from the Wet Barefoot Test Method, whilst R9, R10, R11 & R12 are derived from the Oil-Wet Inclining Platform Test Method. Notes: Controlled Document TR 4586 4S version 12 25.06.2014 Mean BPN Slip Resistance Value (SRV) 48 48 48 48 51 51 51 51 55 55 55 55 54 52 52 53 47 47 47 47 51 Sliptest Australia Pty Ltd P4 The above classifications are provided without Slope Correction Values Materials Testing Laboratory - Accreditation number 15374 12 Blackbean Court ELANORA QLD 4221 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/National standards. P5 (V) P4 (W) P3 (X) P2 (Y) P1 (Z) P0 (Z) AS 4586 (2013) Table 2 AS 4663 (2004) Table 1 Classification of pedestrian surface materials according to the wet pendulum test Interpretation of the wet pendulum results Pendulum* SRV (see note 1) Pendulum* mean BPN * Notional contribution of the Class Four S rubber TRL floor surface to the risk of Slider 96 Slider 55 rubber slipping when water wet P5 >54 >44 >54 >44 Very Low P4 45-54 40-44 45-54 40-44 Low P3 35-44 35-39 35-44 - Moderate P2 25-34 20-34 25-34 - High P1 12-24 <20 <25 - Very High P0 <12 -

Registered Testing Authority - CSIRO 29 April 2015 Our Ref. EN13 / 2337 03/0212 TEST REPORT No. 7325.10 Requested by: Metro Tiles Pty Ltd 192 Granite Street Geebung QLD 4034 on (date): 20 March 2015 Manufacturer: Saime Product Desc.: Roc Series KAL 300x600mm Sampling details: Where: Delivered Date: 20 March 2015 By whom: Courier How (methods): The results reported relate only to the sample(s) tested and the information received. No responsibility is taken for the accuracy of the sampling unless it is done under our own supervision. CSIRO cannot accept responsibility for deviations in the manufactured quality and performance of the product. While CSIRO takes care in preparing the reports it provides to clients, it does not warrant that the information in this particular report will be free of errors or omissions or that it will be suitable for the client's purposes. CSIRO will not be responsible for the results of any actions taken by the client or any other person on the basis of the information contained in the report or any opinions expressed in it. The reproduction of this test report is only authorised in the form of a complete photographic facsimile. Our written approval is necessary for any partial reproduction. This test report consists of 3 pages SUMMARY OF SLIP RESISTANCE TESTS PERFORMED: Result Class AS 4586:2013 Slip resistance classification of new pedestrian surface materials, Appendix D: OIL-WET Ramp Corrected mean overall acceptance angle: 31 R 12 In order to interpret the classifications, please refer to Standards Australia Handbook 198, An Introductory Guide to the Slip Resistance of Pedestrian Materials, which recommends minimum classifications for a wide variety of locations. It is important to realise that test results obtained on unused factory-fresh samples may not be directly applicable in service, where proprietary surface coatings, contamination, wear and subsequent cleaning all influence the behaviour of the pedestrian surface.

REPORT NO: 7325.10 Page 2 of 3 ISSUE DATE: 29 April 2015 MANUFACTURER: Saime PRODUCT DESC: Roc Series KAL 300x600mm SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS OIL-WET RAMP TEST METHOD TEST CARRIED OUT IN ACCORDANCE WITH AS 4586:2013 (Appendix D) Test Date: 10 April 2015 Location: Slip Resistance Laboratory Test conducted by: KH, AG Sample Fixed Joint width: 0 mm structure: [ ] Smooth [ X ] Profiled [ ] Structured RESULTS Corrected mean overall acceptance angle: 31 Displacement space: not tested CLASSIFICATION: Slip Resistance Assessment Group: R 12 Displacement Space Assessment Group: - Test shoe used: Uvex Athletic

REPORT NO: 7325.10 Page 3 of 3 ISSUE DATE: 29 April 2015 MANUFACTURER: Saime TILE DESC: Roc Series KAL 300x600mm Date and Place 29 April 2015, Highett, Vic Name, Title and Digital Signature: KHANH HO Technical Officer Tel: 61 3 92526119 Fax: 61 3 92526244 Email: Khanh.Ho@csiro.au PR:H300415-13:49:50

Report Prepared For: Project: Property Tested: SAIME ROC SURFACE SERIES - KAL GRIGIO - 300 X 600 Date Tested: 09.03.15 Test Report No: KO090315-3 Issue Date: 09.03.15 Fixed Test: Number of sites tested 5 Test location TILE 1 1 <1.5 75 75 75 75 TILE 2 2 <1.5 75 74 74 74 TILE 3 3 TILE <1.5 76 76 76 76 TILE 4 4 <1.5 72 72 72 72 TILE 5 5 <1.5 70 70 70 70 Temperature: 33 o C Mean BPN Slip Resistance Value (SRV) before temperature adjustment 73 Weather: Fine Temperature adjusted if applicable Mean BPN Slip Resistance Value (SRV) for (33 o C) 75 Testing is performed in the anticipated direction of pedestrian travel Unfixed Test : Testing is performed in the direction of least anticipated slip resistance SA HB 198:2014 TABLE 3A MINIMUM WET PENDULUM TEST OR OIL-WET INCLINING PLATFORM CLASSIFICATIONS THAT ARE DEEMED-TO-SATISFY THE BUILDING APPLICATIONS IN THE NCC Location Pendulum / Ramp SA HB 198:2014 TABLE 3B WET PENDULUM TEST OR OIL-WET INCLINING PLATFORM CLASSIFICATIONS FOR APPLICATIONS WHERE THE NCC DOES NOT REQUIRE SLIP RESISTANCE Location Pendulum / Ramp Ramp classes A, B & C are derived from the Wet Barefoot Test Method, whilst R9, R10, R11 & R12 are derived from the Oil-Wet Inclining Platform Test Method. Notes: Controlled Document TR 4663 4S version 12 25.06.2014 SLIPTEST AUSTRALIA PTY LTD ~ ABN 80 111 154 324 12 Blackbean Court ELANORA QLD 4221 PH 0418 75 3311 SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS AS 4586 (2013) Appendix A (Wet Pendulum Method) METRO TILES Testing Instrument: Munro Portable Skid Tester # 1133 Calibration Date: 27.08.13 Testing Officer & Signatory: Kathryn Ording Client Address: SAIME ROC SURFACE SERIES - KAL GRIGIO - 300 X 600 Testing was carried out using the Wet Test Method, using Slider 55 (TRL) rubber slider, in accordance with Australian Standard AS 4586 Appendix A Slider was conditioned/prepared using P400 abrasive paper and 3 µm lapping film Test No. Type Gradient Degrees Type and extent of Cleaning Performed Results of last three swings British Pendulum Number Mean BPN Test Slope Correction value (SCV) 192 GRANITE STREET GEEBUNG QLD 4034 Classification of Pedestrian surface materials according to the AS 4586 wet pendulum test P5 Sliptest Australia Pty Ltd Materials Testing Laboratory - Accreditation number 15374 12 Blackbean Court ELANORA QLD 4221 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/National standards. P5 (V) P4 (W) P3 (X) P2 (Y) P1 (Z) P0 (Z) Comments The above classifications are provided without Slope Correction Values Reported mean value has been corrected +2 for temperature (33 o C) as TRL rubber used for testing. AS 4586 (2013) Table 2 AS 4663 (2004) Table 1 Classification of pedestrian surface materials according to the wet pendulum test Interpretation of the wet pendulum results Pendulum* SRV (see note 1) Pendulum* mean BPN * Notional contribution of the Class Four S TRL floor surface to the risk of Slider 96 Slider 55 rubber rubber slipping when water wet P5 >54 >44 >54 >44 Very Low P4 45-54 40-44 45-54 40-44 Low P3 35-44 35-39 35-44 - Moderate P2 25-34 20-34 25-34 - High P1 12-24 <20 <25 - Very High P0 <12 -