We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Similar documents
GEA Fan Coil Units Effective and quiet. Quality in detail GEA Cassette-Geko. Product Brochure

MultiMAXX HN OPERATION MANUAL

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

CR1 Series Triton Corrosion Resistant Washdown Heaters

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified

TopVent Design Handbook

OPERATION MANUAL Air Curtains MultiMAXX HT. Air Curtains for Industrial Application

SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified

Technology for life. Unit heater LH

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

... UDSA - UDSBD Gas fired unit heaters...

42AM. Air heaters PRODUCT SELECTION DATA

High temperature air-to-water heat pumps

Technical documentation Fan coil unit

Gas-fired unit heaters for indoor installation

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

CAW Ceiling-mounted fan heaters for hot water

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

QZB "Standard" comfort fan coil

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Centrifugal air heaters hot water or electrical supply

The ultimate in air handling units: directly and indirectly fired

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Main technical datas:

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Fan coil unit KL. Wall unit Ceiling unit

The ultimate in air handling units: directly and indirectly fired

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

HEATING AND COOLING DEVICE AGC

Industrial infrared heater IR For premises with large volumes and high ceilings

iq Star LYRA II chilled beam cassette

WOLF VENTILATION SYSTEM PRICE LIST

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Polaris-I-60. active chilled beam. the future of space conditioning

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

The ultimate in air handling units: directly and indirectly fired

The computer for optimum climate in every pig house

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

TopVent. Recirculation Units and Supply Air Units for Heating and Cooling High Spaces.

Fan heater Panther Powerful fan heater for large premises

Industrial infrared heater IR

FAN COIL UNITS. The optimal solution for limited space

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

CASSETTE UNIT. Comfort Circle

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Fan heater SWT Ceiling mounted fan heater with water heat

KPSW CONSOLE TERMINAL UNIT

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

CLIMACIAT AIR COMPACT

Evaporators 60HZ version

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

WOLF WARM AIR CURTAIN

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Thermozone ADR 200/300 E/W

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER


The ultimate in air handling units: directly and indirectly fired

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Energy-efficient heat source provides comfort in large rooms

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

Küba SG commercial

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

NEW GREEN TECHNOLOGY

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Gas heaters and convectors ROBUR

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

AIR COOLED CONDENSERS

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

next DX.U.S* 052.Z2.H6.DC

CHILLED BEAM CASSETTE IQ STAR LYRA

iq Star LYRA II chilled beam cassette

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Flexible and efficient: Close Climate Control for IT equipment

Units for suspended ceilings

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Fan heater Panther WALL MOUNTED FAN HEATER

Product Brochure Fan Coil Units Effective and quiet HyCassette-Geko and Cassette-Geko. Quality as a sign of the times

Transcription:

We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems

Short Description/Overview of Capacity Quick solution for heating of industrial halls For more than 50 years unit heaters of series GEA MultiMAXX have been successfully used on industrial premises and meet all customer requirements thanks to the demanding engineering standards and reliability. Enhanced flexibility and personalized adjustment to customer wishes constitute the most important advantages of GEA MultiMAXX unit heaters. Irrespective of the functional requirements like heating or cooling, recirculating air or mixed air operation mode - with the GEA MultiMAXX units you are always making the right choice. Together with the current catalogue we are presenting a part of our product range that shall to the largest extent cover your requirements in these most common applications. For classical heating of industrial halls we offer the designed for 400V ~ operating voltage with a mounted fan switch. Prompt stands for easy selection and quick availability while making sure the high quality standards are met. Please select the basic unit together with either basic discharge for wall, profile discharge (wall or ceiling installation) or double side discharge (ceiling ) as well as our of type Compact C. The selection range also includes a 2-speed switch unit MC 302, room thermostat or an industrial thermostat as well as an intermediate terminal box for operating multiple units. Select the right depending on the requirements and specify the relevant sales/order number to place your order with us. As an essential part of our portfolio we offer a comprehensive range of components like heat exchangers, motors and discharge elements as well as miscellaneous accessories. with Profile discharge wall/ceiling Basic discharge wall Basic discharge ceiling two sides 12 P 12 P P 12 W P 12 D 22 P 22 P P 22 W P 22 D 31 P 31 P P 31 W P 31 D 32 P 32 P P 32 W P 32 D Copyright note Disclosing, copying, distributing or taking any action in reliance on the contents of this document is strictly prohibited without express prior consent. Violations entail liability for any damages or other liability arising. All rights in relation to patents, utility patents or design patents are reserved. 2 PR-2009-0018-GB Subject to modifications Status 11/2010

Unit Description Wide wing fan Axial fan with an external rotor motor for normal pressure and sound requirements as well as fan protection curb with an integrated contact protection grille according to ISO 13 857. Maintenance free aluminium wide wings are balanced at factory and are wired on the terminal box with a humidity-proof motor. The fan has IP 54 protection class, thermal class F and is fitted with a thermal contact and a fan switch. Intake nozzle is performed as a short nozzle. Range of application: Air inlet : -20 to +40 C Cu/Al Heat exchanger (HE) Heat exchanger for heating with warm water pump is designed for treating air with low dirt concentration. The heat exchanger is performed with copper pipes with profiled aluminium fins having 2.5 mm spacing. Range of application: Maximum operating : Maximum operating pressure: 130 C 16 bar Profile discharge (wall or ceiling installation) The profile discharge comprises air deflection louvres performed in galvanized aluminium and RAL 7000 metal sheet frame and is designed for increasing air throw. In such a way the unit can be easily installed at average mounting heights. The self-locking profile discharge can be manually adjusted and has a variable design depending on ceiling or wall installation. Wall basic discharge Galvanized metal sheet louvers of a wall basic discharge enable to deflect conditioned air at the needed discharge angle. Each self-locking louver of the basic discharge can be adjusted manually. Basic discharge ceiling two sides device for low installation heights. Galvanized metal sheet louvers enable to deflect conditioned air at two required discharge angles. PR-2009-0018-GB Subject to modifications Status 11/2010 3

Unit Data 12 (400 V~) Speed [min-1] 1050 1320 Max. power consumption [kw] 0.09 0.14 Max. current consumption [A] 0.28 0.49 Sound pressure * [db(a)] 52 56 With profile discharge (wall or ceiling) Air volume flow [m 3 /h] 1580 2010 + 5 14 32 5.2/4.7 16 29 6.4/6.3 + 15 11 36 5.7/5.3 13 34 6.9/7.1 + 18 10 38 5.8/5.5 12 36 7.1/7.4 + 20 10 38 6.0/5.7 11 36 7.2/7.7 + 5 18 38 4.9/4.2 20 35 5.9/5.7 + 15 15 42 5.2/4.7 17 40 6.3/6.2 + 18 14 44 5.3/4.8 16 41 6.4/6.4 + 20 13 45 5.4/4.9 15 42 6.5/6.6 + 5 21 44 4.6/3.9 24 40 5.6/5.2 + 15 18 49 4.9/4.2 21 45 5.9/5.6 + 18 17 47 4.9/4.3 19 50 6.0/5.8 With basic discharge wall/ceiling two sides + 20 16 48 5.0/4.4 19 51 6.1/5.9 Air volume flow [m 3 /h] 1750 2200 + 5 15 31 4.7/3.9 17 28 5.7/5.1 + 15 12 35 5.1/4.3 14 33 6.2/5.8 + 18 11 37 5.3/4.5 12 35 6.4/6.0 + 20 10 37 5.4/4.7 12 36 6.5/6.2 + 5 19 37 4.4/3.5 21 34 5.3/4.6 + 15 16 41 4.7/3.8 18 39 5.7/5.1 + 18 15 43 4.8/3.9 17 40 5.8/5.2 + 20 14 44 4.9/4.0 16 41 5.9/5.4 + 5 22 43 4.2/3.2 25 39 5.0/4.3 + 15 19 47 4.4/3.4 22 44 5.3/4.6 + 18 18 49 4.5/3.5 21 46 5.4/4.7 + 20 17 49 4.5/3.6 20 47 5.5/4.8 * Sound pressure: approximated values at 5 m distance to the unit side, at maximum air flow rate and low reflection room. Industrial hall volume 1500 m3/h, absorption surface 200 m2 Sabin, hemispherical radiation = direction coefficient 2. These values can be significantly influenced by the indoor characteristics in a positive or negative way. 4 PR-2009-0018-GB Subject to modifications Status 11/2010

Unit Data 22 (400 V~) Speed [min-1] 890 1270 Max. power consumption [kw] 0.19 0.29 Max. current consumption [A] 0.35 0.61 Sound pressure * [db(a)] 54 61 With profile discharge (wall or ceiling) Air volume flow [m 3 /h] 2400 3280 and outle + 5 22 32 5.8/5.3 26 29 7.5/7.8 + 15 17 37 6.3/6.0 21 34 8.1/8.8 + 18 16 38 6.4/6.2 19 35 8.3/9.1 + 20 15 39 6.6/6.4 18 36 8.5/9.4 + 5 27 39 5.4/4.8 32 34 7.0/7.1 + 15 23 43 5.8/5.3 27 39 7.4/7.7 + 18 21 44 5.9/5.4 25 41 7.6/8.0 + 20 20 45 6.0/5.6 24 42 7.7/8.1 + 5 32 44 5.1/4.4 38 39 6.6/6.5 + 15 27 49 5.4/4.8 33 45 7.0/7.0 + 18 26 50 5.5/4.9 31 46 7.1/7.2 + 20 25 51 5.6/5.0 30 47 7.2/7.3 With basic discharge wall/ceiling two sides Air volume flow [m 3 /h] 2660 3620 temp [ C] + 5 23 31 5.3/4.3 28 28 6.8/6.3 + 15 19 36 5.7/4.9 22 33 7.3/7.2 + 18 17 37 5.8/5.1 20 35 7.5/7.5 + 20 16 38 5.9/5.2 19 36 7.7/7.7 + 5 29 37 4.9/3.9 34 33 6.3/5.7 + 15 24 42 5.2/4.3 28 38 6.7/6.3 + 18 22 43 5.3/4.4 27 40 6.9/6.5 + 20 21 44 5.4/4.5 25 41 7.0/6.6 + 5 34 43 4.7/3.6 40 38 6.0/5.3 + 15 29 48 4.9/3.9 34 43 6.3/5.7 + 18 28 49 5.0/4.0 33 45 6.4/5.9 + 20 27 50 5.0/4.1 32 46 6.5/6.0 * Sound pressure: approximated values at 5 m distance to the unit side, at maximum air flow rate and low reflection room. Industrial hall volume 1500 m3/h, absorption surface 200 m2 Sabin, hemispherical radiation = direction coefficient 2. These values can be significantly influenced by the indoor characteristics in a positive or negative way. PR-2009-0018-GB Subject to modifications Status 11/2010 5

Unit Data 31 (400 V~) Speed [min-1] 660 900 Max. power consumption [kw] 0.20 0.31 Max. current consumption [A] 0.50 0.88 Sound pressure * [db(a)] 55 61 with profile discharge (wall or ceiling) Air volume flow [m 3 /h] 4130 5180 + 5 22 21 8.1/8.5 24 19 9.8/11.3 + 15 17 28 8.7/9.5 19 26 10.6/12.6 + 18 16 30 9.0/9.9 18 28 10.9/13.2 + 20 15 31 9.2/10.2 17 30 11.1/13.6 + 5 26 24 7.6/7.7 30 22 9.2/10.2 + 15 22 31 8.1/8.4 25 29 9.8/11.2 + 18 21 33 8.2/8.7 23 31 10.0/11.5 + 20 20 35 10.1/11.8 22 33 8.4/8.9 + 5 31 28 7.2/7.1 35 25 8.7/9.4 + 15 27 34 7.6/7.6 30 32 9.2/10.2 + 18 26 37 7.7/7.8 28 34 9.3/10.4 + 20 25 38 7.8/8.0 27 36 9.4/10.6 With basic discharge wall/ceiling two sides Air volume flow [m 3 /h] 4850 5840 temp [ C] + 5 23 19 7.8/7.4 26 18 9.1/9.5 + 15 19 27 8.3 20 25 9.8/10.7 + 18 17 29 8.6 19 28 10.1/11.1 + 20 16 30 8.8/8.9 18 29 10.3/11.4 + 5 29 23 7.3/6.7 31 21 8.5/8.6 + 15 24 30 7.7/7.3 26 28 9.0/9.4 + 18 22 32 7.9/7.6 24 31 9.2/9.7 + 20 22 33 8.0/7.7 23 32 9.3/9.9 + 5 34 26 6.9/6.2 37 24 8.1/7.9 + 15 29 33 7.2/6.7 32 31 8.5/8.6 + 18 28 35 7.4/6.8 30 33 8.6/8.8 + 20 27 36 7.4/7.0 29 35 8.7/8.9 * Sound pressure: approximated values at 5 m distance to the unit side, at maximum air flow rate and low reflection room. Industrial hall volume 1500 m3/h, absorption surface 200 m2 Sabin, hemispherical radiation = direction coefficient 2. These values can be significantly influenced by the indoor characteristics in a positive or negative way. 6 PR-2009-0018-GB Subject to modifications Status 11/2010

Unit Data 32 (400 V~) Speed [min-1] 660 900 Max. power consumption [kw] 0.20 0.31 Max. current consumption [A] 0.50 0.88 Sound pressure * [db(a)] 55 61 With profile discharge (wall or ceiling) Air volume flow [m 3 /h] 3680 4720 + 5 34 33 7.6/7.7 39 30 6.2/5.7 + 15 27 37 6.7/6.4 31 35 8.2/8.6 + 18 25 38 6.9/6.6 29 36 8.5/9.0 + 20 24 39 7.0/6.8 27 37 8.6/9.3 + 5 42 39 5.8/5.2 48 35 7.2/7.0 + 15 35 43 6.2/5.6 40 40 7.6/7.6 + 18 33 45 6.3/5.8 38 42 7.8/7.9 + 20 31 45 6.4/5.9 36 43 7.9/8.1 + 5 49 45 5.5/4.8 57 41 6.8/6.4 + 15 42 49 5.8/5.1 48 46 7.1/6.9 + 18 40 50 5.9/5.3 46 47 7.2/7.1 + 20 39 51 6.0/5.3 44 48 7.3/7.2 With basic discharge wall/ceiling two sides Air volume flow [m 3 /h] 4150 5200 temp [ C] + 5 36 31 5.7/4.8 41 29 6.9/6.3 + 15 29 36 6.2/5.3 33 34 7.4/7.1 + 18 27 37 6.3/5.6 30 35 7.6/7.4 + 20 25 38 6.5/5.7 28 36 7.8/7.6 + 5 45 37 5.4/4.3 50 34 6.5/5.7 + 15 37 42 5.7/4.7 42 39 6.9/6.3 + 18 35 43 5.8/4.9 40 41 7.0/6.5 + 20 33 44 5.9/5.0 38 42 7.1/6.6 + 5 53 43 5.1/4.0 59 39 6.1/5.3 + 15 45 48 5.3/4.3 51 44 6.4/5.7 + 18 43 49 5.4/4.4 49 46 6.5/5.8 + 20 42 50 5.5/4.5 47 47 6.6/6.0 * Sound pressure: approximated values at 5 m distance to the unit side, at maximum air flow rate and low reflection room. Industrial hall volume 1500 m3/h, absorption surface 200 m2 Sabin, hemispherical radiation = direction coefficient 2. These values can be significantly influenced by the indoor characteristics in a positive or negative way. PR-2009-0018-GB Subject to modifications Status 11/2010 7

Unit Data Suspension type compact C ZHx.5300 J Ø 16 C D B Speed switch unit MC302 Intermediate terminal box 981860 Room thermostat 902005 Industrial thermostat 902013 Ø 10 For recirculating air units for wall and ceiling installation; galvanized metal sheet Type GEA MultiMAXX Prompt 12 GEA MultiMAXX Prompt 22 GEA MultiMAXX Prompt 31/32 Article Nr. ZH1.5300 ZH2.5300 ZH3.5300 B [mm] 340 392 504 C [mm] 445 544 680 D [mm] 40 40 50 J [mm] 303 389 484 X [mm] 414 510 628 Weight [kg] 2.9 3.9 8.2 Plastic casing for wall mounting, light grey with a separate section for connecting terminals Protection class IP54 Contactor, 4 kw switching capacity according to AC3, max. current 9 A Motor full protection electronics with automatic repeated start after power outage and interlocking disconnection Control lights for operational readiness and error Connection terminals for room thermostat or external ON/OFF contact Intermediate terminal box for connecting a maximum of 4 units Plastic casing for on-wall mounting with space for loop-in wiring Protection class IP54 Row terminals 2.5 mm² Dimensions 270 x 220 x 105 mm (W x H x D) Measurement of room with plastic casing Protection class IP30 Setpoint range 5... 30 C Thermal feedback 230 V and 24 V Switch-over contact Internal min. and max. setpoint scale fix Switching capacity at 250 V~ contact 10(4) A Cooling contact 5(2) A Measurement of room with aluminium die-cast / plastic casing and closed capillary system Protection class IP54 Setpoint range/setpoint setting 0 35 C Sensor coil s performed in stainless steel (V4A) with a protective basket Switching difference 0.5 1 K Switch-over contact 15 A ohm. 8 A ind. 250 V 8 PR-2009-0018-GB Subject to modifications Status 11/2010

Dimensions and Weight with Suspension K C D E G A Ø 16 mm F J B X GEA MultiMAXX Prompt 12 Prompt 22 Prompt 31 Prompt 32 Unit Width A [mm] 642 738 866 866 Height B [mm] 520 616 744 904 Depth C [mm] 386 387 387 387 Connection dimensions Fan casing/he-spigot D [mm] 273 273 273 273 Distance of HE connections E [mm] 75 75 75 75 Distance of HE connections F [mm] 457 553 681 681 Water charge of heat exchanger [l] 1.7 2.4 1.8 3.5 Nominal connection width of heat exchanger G1" G1" G1¼" G1¼" outlets Profile discharge G [mm] 100 100 100 100 Wall basic discharge G [mm] 105 105 105 105 Basic discharge ceiling two sides G [mm] 105 105 105 105 Suspension Compact C ZH1.5300 ZH2.5300 ZH3.5300 ZH3.5300 Hole spacing width X [mm] 414 510 628 628 Hole spacing height J [mm] 303 389 484 484 Wall distance K [mm] 282 334 446 446 Weight (unit+discharge) Profile discharge approx. [kg] 30 39 52 55 Wall basic discharge [kg] 27 35 46 49 Ceiling two sides [kg] 27 35 46 49 PR-2009-0018-GB Subject to modifications Status 11/2010 9

Space for Notes 10 PR-2009-0018-GB Subject to modifications Status 11/2010

Space for Notes PR-2009-0018-GB Subject to modifications Status 11/2010 11