Modular Water Cooled Water Chiller

Similar documents
Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd.

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

MAC-A R410A Series Air cooled Modular Chiller

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

MODELS LIST. Nominal Capacity RT

kw COOLING kw HEATING

MODULAR CHILLER. R410a R22

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

DAIKIN Modular Inverter Air Cooled Chiller

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Air Cooled Scroll Chiller

Rooftop Packaged Unit 10kW-110kW. Vicot Air Conditioning Co., Ltd

Modular Air Cooled Scroll Chillers

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

OIL FREE CENTRIFUGAL CHILLER

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Refrigeration dryers for energy efficient compressed air quality

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

Scroll Water Cooled Chiller

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

Vicot Air Conditioning Co., Ltd. CONTENT

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

ERACS.C-N Higher efficiency air-cooled screw pump

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Water-cooled Centrifugal Chiller

44,9 202,0 kw. technicalcatalogue

nemo a hp rcgroupairconditioning R410A

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

kw. technicalcatalogue

HEAT PUMP. Dongguan New Times New Energy Science & Technology Co., Ltd.

Modular Water-Cooled Chiller

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

GENERAL INFORMATIONS

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

GHE Dehumidifiers for radiant cooling systems with heat recovery

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Screw Water Cooled Chiller SCW210

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

Air Cooled Scroll Chiller / Heat Pump

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

MODULAR WATER-COOLED CHILLER

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Aquaflair TRAC-TRAF-TRAH

GLIDER_. air cooled liquid chilled chillers / heat pumps

ULTRA SERIES CIRCULATING AIR SOURSE HEAT PUMP WATER HEATER

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

New standard in compressed air treatment, providing Energy Savings up to 99%

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

.2 Section Waste Management and Disposal.

water to water heat pumps

ACMVTECH HIGH EFFICIENCY UNITARY AHU

kw. technicalcatalogue

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

R134a. DCLC Series 50Hz. Water Cooled Centrifugal Chillers Cooling Capacity: 300 to 1500 TR (1055 to 5274 kw)

Installation Operation Maintenance

Water cooled chillers and heat pumps

R22 air-cooled modular chiller 50Hz unit. Content

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

TCHE-THHE TCEE

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)


F Series - Refrigeration dryers

CGWP Small Scroll Chiller Cabinet Water Cooled Cold Generator 10~100 Tons

Transcription:

Modular Water Cooled Water Chiller Shandong Vicot Air Conditioning Co., Ltd.

Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized in central air conditioning products. Its new industrial park covers a total area of 140,000 m 2 including workshop area of 50,000 m 2. There are 1000 people including 800 workers, 18 senior engineers, 5 doctors and masters, 40 engineers for R&D, and more than 55 technicians, etc. There are five assembly lines, two condenser& evaporator production lines, one painting line, and many large equipments such as vertical tube expander, CNC guillotine shear (shearing machine), CNC tube bending machine and many auxiliary apparatus,laboratories, and online testing rooms. All of them can achieve the exact Control of production process and guarantee the product quality. Chiller assembly line Testing Lab. Painting line CNC machine We have ISO9001 & 1SO14001, CE, CCC certificates.

Modular water cooled water chiller Contents Introduction.. 1 Features....1 Nomenclature...2 Optional accessories/function.. 2 Specification... 3 Capacities/power input in different conditions 4 Dimension...5 Wire connection at site... 6 Installation and maintenance.....7

Shandong Vicot Air Conditioning Co.,Ltd. Introduction VWMA series water cooled water chiller is a new generation of water cooled water chiller product developed by Vicot with great efforts, and it represents these years of experience of design, production of ground source heat pump and modularizing and the combining of the newest advanced technology, the unit is suitable for various places, such as office blocks, hotels, hospitals, factories, houses, etc. It is a more fashion, adhering to the "efficient, reliable, energy saving, environmental protection," the design concept, become available to users of the newer and more economical outstanding products. Features 1. Less investment 1) Outdoor installation design (patent NO.ZL200620087478.3) no need of installation room, saves investment costs. 2) Modular connection design facilitates the expansion of operation capacity; users can install the units according to the capacity required for construction in different time. 2. High efficiency, Energy saving Modular parallel combination, compressor parallel design, not only provide a much larger operation capacity for unit, but also the closer match between output of capacity and cooling load, reduces idling energy consumption. The energy efficiency comparison between Modular type and non modular water cooled water chiller: 3. Quality components selection 1) Compressors and refrigeration accessories all chosen world-renowned brand products to ensure that the unit reached an excellent level of performance 2) Using the most advanced DAE / DAC efficient heat transfer pipe, heat transfer surface with internal ribbed tube makes the heat transfer coefficient substantially increased; the heat exchanger unique structural design, the best way of copper tube layout and precision of refrigerant control technology, greatly improved the efficiency of heat transfer. 4. Noise Reduction, Environment friendly 1) Completely closed mute design makes operation quietly, reduce noise pollution. 2) Optional allocation of environmental friendly refrigerants. 1

Modular Water Cooled Water Chiller 5. Safe and convenient 1) Small size, light weight, easy for installation, transfer and maintenance, can be put into use just make water pipes and the power supply cable be connected at the site. 2) The modules start one by one, starting current greatly reduced, effectively improve the safety performance 3) Independent of each module, when any one of those modules failure or in need of maintenance, the other module can still run as usual, without any impact. 4) All the components covered with casing, keeps damages to cooling and electrical system away. 5) Advanced microcomputer automatic control system, with protection of high and low pressure, overload, low voltage, phase lack, and low temperature etc., with terminal for the external pumps, and displays and alarms malfunction. Nomenclature Optional accessories/function 1. Heat reclaim function 2. Low noise type 3. Soft startup 4. PLC Controller 5. Wooden package 6. R407c Refrigerant 7. R134a Refrigerant 8. R410a Refrigerant 9. Rubber vibration damper 10. Spring vibration damper 11. Remote control cabinet 12. Cooling or heating capacity can be extended to lower capacities, such as 20kW, 30kW, 38kw or 50kW 2

Shandong Vicot Air Conditioning Co.,Ltd. Specification Model VWMA80 VWMA120 VWMA160 VWMA260 VWMA360 Cooling capacity (R22) kw/btu 76/259386 115/392492 162/552901 260/887372 360/12288669 Total input power(r22) kw 16 24 32 51 70 Cooling capacity (R407C) kw/btu 72/245734 110/375427 154/525597 248/846416 343/1170648 Total input power(r407c) kw 17 25 33 53 73 Max. operating current A 40 60 80 120 160 Compressor type Full-Hermetic scroll Power V/Ph/Hz 380/3/50 Refrigerant R22/R407C Refrigerant charge amount kg 11 16 23 38 51 Chilled water inlet temp. 12 Chilled water outlet temp. 7 Chilled water flow m 3 /h 13 20 28 45 62 Chilled water pressure drop kpa 100 100 125 110 100 Cooled water connection pipe DN65 DN65 DN65 DN100 DN100 Cooling water inlet temp. 30 Cooling water outlet temp. 35 Cooling water flow m 3 /h 16 24 33 54 74 Cooling water pressure drop kpa 120 120 160 140 125 Cooling water connection pipe DN65 DN100 Partial heat recovery kw/btu 15/51195 23/78498 32/109215 52/177475 72/245734 Partial heat recovery hot water flow m 3 /h 1.5 4 6 9 12 Partial heat recovery hot water pressure drop Total heat recovery capacity kpa 32 33 35 38 40 kw /BTU 90/307167 135/460751 180/614335 290/989761 400/1365188 Total heat recovery hot water flow m 3 /h 14 22 31 50 69 Total heat recovery hot water pressure drop kpa 126 125 154 135 120 Length mm 1730 1730 2300 2300 2300 Width mm 950 1200 955 1700 1700 Height mm 1450 1450 2090 2090 2090 Noise(standard) db(a) 62 63 64 65 66 Noise(Low Noise) db(a) 59 59 60 60 61 Transport weight kg 520 720 950 1600 2100 Operating weight kg 550 750 1000 1720 2300 Note: 1) Heat recovery device is optional, water inlet temp. is 40, water outlet temp. 45. 2) Water side max. bearing pressure: 1.0MPa 3) The data above is subject to change without prior notice. 3

Modular Water Cooled Water Chiller Capacities/power input in different conditions VWSA Cooling Capacity Correction coefficient Outlet Cooled Cooling water inlet temp. Water temp. 25 26 27 28 29 30 31 32 33 34 35 36 37 5 1.01 1.00 0.99 0.97 0.96 0.95 0.94 0.92 0.91 0.90 0.89 0.88 0.87 7 1.07 1.05 1.04 1.03 1.01 1.00 0.99 0.97 0.96 0.95 0.94 0.92 0.91 9 1.12 1.11 1.09 1.08 1.07 1.05 1.04 1.03 1.01 1.00 0.99 0.97 0.96 11 1.18 1.17 1.15 1.14 1.12 1.11 1.09 1.08 1.07 1.05 1.04 1.03 1.01 13 1.25 1.23 1.21 1.20 1.18 1.17 1.15 1.14 1.12 1.11 1.09 1.08 1.07 15 1.31 1.29 1.28 1.26 1.25 1.23 1.21 1.20 1.18 1.17 1.15 1.14 1.12 VWSA Power input Correction coefficient Outlet Cooled Cooling water inlet temp. Water temp. 25 26 27 28 29 30 31 32 33 34 35 36 37 5 0.863 0.886 0.910 0.934 0.959 0.985 1.011 1.037 1.064 1.092 1.120 1.149 1.179 7 0.877 0.900 0.924 0.949 0.974 1.000 1.026 1.053 1.080 1.108 1.137 1.166 1.197 9 0.890 0.913 0.938 0.963 0.989 1.015 1.041 1.068 1.096 1.125 1.154 1.184 1.215 11 0.903 0.927 0.952 0.977 1.003 1.030 1.057 1.084 1.113 1.142 1.171 1.202 1.233 13 0.917 0.941 0.966 0.992 1.018 1.046 1.073 1.101 1.129 1.159 1.189 1.220 1.251 15 0.930 0.955 0.981 1.007 1.034 1.061 1.089 1.117 1.146 1.176 1.207 1.238 1.270 4

Dimension Shandong Vicot Air Conditioning Co.,Ltd. VWMA80 VWMA120 VWMA160 5

Modular Water Cooled Water Chiller VWMA260 VWMA360 Wiring connection at site Power supply connection and internal wiring should be done at site: 6

Shandong Vicot Air Conditioning Co.,Ltd. Installation and Maintenance 1. The preparation 1) After arriving the installation site, check all the items of the unit carefully according to the packing list if there are damage, lack of parts or damage during transport, notify the sales department. 2) The user must provide a rigid nondeforming foundation or concrete footings, based on the size of the unit four positioning hole; the foundation of the unit can also be framework structure, framework should be placed on main beam or column, and be capable of bearing the weight 150% heavier than the unit. The horizontal level should have no slope. Lifting unit diagram 3) For easy handling, users should use the crane, the machine should properly protected by soft material on the point of force applied, and also be in balanced status during handling to avoid possible damage. 4) Choose the Installation Place Units can be installed indoor or outdoor, should consider the following factors: a) Installation place should be capable of bearing the weight 150% heavier than the unit. The horizontal level should have no slope. b) Should keep enough space surrounding and on the top of the machine for access of maintenance. c) Should have drain in the surrounding of the machine for release the water for seasonal stop of machine. 5) Foundation reference Note: a) The foundation should be concreted structure or frame of steel, with a plane surface b) 10-20mm isolator for shock absorption should be placed between the unit and foundation. c) Foundation design can based on the machine net weight. d) Fix the unit with φ16 foundation bolt e) Foundation diagram 7

Modular Water Cooled Water Chiller VWMA80/VWMA80N Foundation Diagram Note: N is the total number of VWMA80 & VWMA80N modular. VWMA120/VWMA160 Foundation Diagram Note: N is the total number of VWMA120 and VWMA160 modular. 8

VWMA260/VWMA360 Foundation Diagram Shandong Vicot Air Conditioning Co.,Ltd. Note: N is the total number of VWMA260 and VWMA360 modular. VWMA260/VWMA360 Foundation Diagram Note: M is the number of VWMA80 modular and VWMA80N, and N is the total number of VWMA120 VWMA120N VWMA160 and VWMA160N 2. Typical multi-modules connection VWMN modular can be extended up to seven modules as one group, connection method as below: (with example of three modules): 9

Modular Water Cooled Water Chiller 3. Typical basic water system diagram: 4. Water system installation 1) The installation should in line with the national and local authorities requirement. 2) Chilled water pipe must be insulated to avoid capacity loss and having condensed water. 3) For the sake of water quality, filter on input pipe is necessary. 4) Dimension of the joint of connection pipe should meet requirement(refer to Technical data) 5) For the sake of automatically discharge air, supply water indirectly and expanding or shrinking of chilled water system, expansion tank is required. And it should 1.5m higher than the highest point of the water system. No valve is allowed in the pipe between the expansion tank and return water system. 6) The air discharge valve should be fixed the highest point of the chilled water system. After connection of the chilled water system finished, and pressure testing is acceptable, open the air discharge valve to exhaust the air in chilled water and close the valve after completely air exhausted. If the water or the pipe inside is not clean, it needs to clean the filter after half an hour s pump operation. 7) Before the first running of the circulation water, close the input/output valve first, then open the bypass valve, run the water pump only to circulate the water in pipe to clean the pipe and clean the filter after that, then add clean water again to the system, then turn on the inlet/outlet valve and close the bypass valve for normal operation. 10

Shandong Vicot Air Conditioning Co.,Ltd. 8) Water segregator, water collector and water pressure balance valve are required when several units to be parallelized. 9) Water drain valve should be fixed at the lowest point of the water system. 10) The design of water piping, please refer to the Air conditioning Design Manual, and the project operation and inspection refer to GB50243-1997 Ventilation & air conditioning project operation and inspection Norms. 5. Power connection 1) Wire selection and connection should be carried out strictly according to requirement. 2) Should have earthing well done, no earthing to gas pipe, water pipe, telephone line, to avoid electric shock cause by bad earthing. 3) Ensure the phase sequence is correct, to avoid not running. 6. Maintenance 1) The qualified technician is required for the maintenance; all the protection devices and controller must be checked before restart. 2) Regular and correct maintenance is required for stability and good performance. Chilled and cooling water must be complete drained when long time no use to avoid possible freezing. 7. Notice 1) Antifreezer should be added in chilled water if water temp. set below zero or near zero. 2) Clean water system regularly. 3) Pay attention to antifreeze when ambient temp. is around 0 in winter. 4) Antifreezer or other antifreeze measure must be used in bad ambient(under 0 outdoor). 11