Automatic Waste Water Lifting Unit

Similar documents
Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

50 Hz. Submersible Waste Water Pumps

mini-compacta Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet

Lifting Plants Product Overview

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

Cleaning System. Amajet. Type Series Booklet

MULTISAN Fully automatic sewage and waste water pump

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

Owners Manual for the Rainmaster Water Recycling System

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

Technical data. Unilift KP. CRUNDFOS "~ ozpump.com.au Drainage pumps. Unilift KP

Trusted Expertise in Domestic and Commercial Wastewater

INFO 3/2015. NEWS WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings.

RC411 Operator Manual

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Owners Manual For The Rainmaster Water Recycling System

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system

Alarm Switchgear AS1-M

JUNG PUMPEN LIFTING STATIONS

LS Condensate Removal Pump Installation, Operation and Service Instructions

Brochure EX

INSTALLATION AND OPERATING INSTRUCTIONS

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

Instruction Manual. Electronic gas and smoke detector GRM

CRU 200 and 500 Series Condensate Recovery Units

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

BRISE. Super-power for heating, cooling and ventilation.

USER S MANUAL DN-2. Drain pump

Building Services. KSB Building Services. A Real Welcome Home.

NEWS 2017 SANIFLO. Pumps and pumping stations

The easy solution for waste water removal

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.

FEATURES. Other Fed-Flush Arrangements

Comfort Odour free Easy handling. Waterless. Environmentally friendly. Feels like home. Comfort wherever you are.

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

SUPPLEMENTARY INSTRUCTIONS

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

TYPE POS Oil Shield Sump Pump

~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)

Lifting Station Type ABS Sanimax

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

POWER and INTELLIGENCE

Feels like home. Unlimited Capacity Odour free Easy handling Waterless. Comfort wherever you are. Environmentally friendly

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Instructions for the fan motor control system, SILVER C

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

RAINWATER FILTERS AND REUSE OF RAINWATER

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

ABS lifting station Sanimax

Instructions for use PHPC 6.4F AM X

Installation instructions Danfoss heat pump DHP-R

SL EX.4.51D

HYGIENE EQUIPMENT INTRODUCTION HYGIENE

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

GRUNDFOS INSTRUCTIONS MSS, MLD. Installation and operating instructions

Cooking c o l l e c t i o n

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Comfort. Odour free Easy handling. Waterless. Environmentally friendly. Feels like home. Comfort wherever you are.

Pump WaterVISE, FloVISE

TP /4-A-F-A-BQQE 400D 50HZ

WATER, OIL, CONTAMINANTS: SEPARATION AND EVACUATION

INSTALLATION GUIDE NZ AU

Hood Type Combi Dishwasher WD-90 DUO. wit h

Greenleaf 600 Macerator Toilet Waste Pump

CombiBloc Close-coupled centrifugal pumps

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Pilot devices Stacklights Signal beacons

Licht und Spiegel # LM 9642

TECHNICAL SPECIFICATION

WISY. Rainwater Harvesting. Installation and Operating Instructions. English. instructions for the. rainwater units. these installation

ELECTRIC PASTA COOKERS

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Condensate water pumps

EHT10 Electric Hot Water Tap

PROPERTY REINSPECTION REPORT

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Rhima Deko 190 Washer-disinfector for human waste containers

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

CR A-F-A-E-HQQE 3x400/ HZ

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Dewatering Solutions for the Real World In the real world time is money, and worksites have no time for unwanted water. Sulzer has the solutions in a

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

PROFESSIONAL HAIR STYLER

The Hood Type Concept

condensate pumps For air conditioning and refrigeration technology eckerle.com

SL S.S.N.51D

Operation Manual. Trash Water Pump ARTICLE Image similar

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Transcription:

Type Series Booklet 2331.55/4-EN Ama r -Drainer-Box 021 Automatic Waste Water Lifting Unit Above-floor-Box 021 Fields of Application Single Lifting Unit - Above-floor Box 021 F Automatic drainage of wash-basins, showers, washing-machines, etc. Medium Handled Standard Variant - Particle Size 10 mm Slightly contaminated water, also containing solid particles with aparticlesizeofupto10mm. For aggressive water, use Ama-Drainer C variant. Ama-Drainer-Box is not suitable for sewage from urinals and toilets. For these applications please use our mini-compacta/ Compacta sewage lifting units. Operating Data Standard Variant Q H t Above-floor Box 021 (25 l) upto8m 3 /h, 2.2 l/s up to 6.5 m up to 35 C 1 ) Anlagen mit größeren Leistungen siehe Baureihenheft Ama-Drainer-Box 2336.51-EN. 1 ) Up to 3 minutes for waste water from hot water cycle of washing-machines and dish washers for non-industrial use. Designation Type series Collecting tank 021 = Code number for Ama-Drainer here Ama-Drainer 301.1 C = Variante für aggressive Medien Design / Variant C Above-floor Box 021: Stable plastic collecting tank with submersible motor pump starting and stopping automatically. DN 50 connection on the suction side, DN 40 connection on the discharge side and integrated swing check valve. Materials Tank Pump -- EN 12 050-2 Überflur-Box 021 Acrylonitrile-butadiene-styrene copolymer (ABS) see Ama-Drainer Type Series Booklet CE -- EN 12 050-2

Single Lifting Units - Above-floor Box 021 301 2331:509 Single Lifting Units (Complete) - Above-floor Box 021 Ama-Drainer-Box Ama-Drainer P 2 50 Hz Power supply Ident. No. cable 1~ 220-- 240 V 3~ 380-- 415 V H 07 RN-F.G. kw I N A I N A m mm 2 kg 021 1 ) Above floor 301 SE 0.15 1.5 -- 3 3 x 0.75 29 127 257 7.5 021/C 1 ) 301 SE/C 0.15 1.5 -- 3 3 x 0.75 29 127 258 7.5 1 ) Supplied completely assembled ex works 2

Standard Variant Above-floor Box 021 Inlet A DN 50 pipe (rubber socket) A Connection to washing-machine, horizontal or vertical via Y-drain pipe Inlet B Connection to shower: special pipe part DN 50 (outside Ø 50) as accessory Discharge side C DN 40 pipe (rubber socket) Venting D Carbon filter insert with overflow protection Wherever possible, we recommend to lead the vent pipe out of the roof (max. outside pipe diameter: 40). for floor or wall mounting Connection to shower (accessory) Anti-rotation device 1 ) Switching levels, standard variant 2 ) Switching levels, variant for shower facilities with special float Installation Schematic - Above-floor Box 021 Backwash level Discharge line In case of water levels above the backwash level, a gate valve should be installed on the discharge side. 3

Product Features to Our Customers Benefit Above-floor Box 021 Discharge line on the left or right on option; other connections possible on all sides, for example to shower facilities, washing-machine, etc. Great flexibility of piping connection Integrated swing check valve Prevents drainage of the discharge line Pressure-sealed casing of ABS D No bad odours D Thermal and dimensional stability D Fully recyclable Modern low-height design Can be connected directly below the wash-basin -- looks better Extremely smooth, wall-mounted tank D Easy-care surface D Wall- mounting facilitates floor cleaning Venting on option through the roof or through activated carbon filter with integrated overflow protection device D No overflow risk Ready-to- connect mini pumping station D Easy and fast installation D DN 40 and DN 50 connection diameters with self-sealing rubber socket are available Powerful, maintenance-free submersible motor pump Reliable, trouble-free operation 4

Accessories Ama-Drainer-Box 021 Shower connection set for above-floor box 18 040 033 0.16 kg all M 1 alarm contactor Magnetic float switch as contactor for alarm switchgears AS 0, AS 2, AS 4 and AS 5; with 5 m power supply cable 18 040 562 0.8 Alarm switchgears Alarm switchgear AS _ 230 V~/ with circuit breaker, piezoceramic signal transmitter, 12 V = 85 db(a) at a distance of 1 m and 4.1 khz, 1.2 VA green equipment-on lamp Plastic housing IP 20, 140 x 80 x 57 mm Use float switch (item E 60), moisture sensor F 1 (item E 64) or M 1 alarm contactor as contactor. Ama-Drainer-Box Ident. No. E50 mains-dependent AS 0 X 29 128 401 0.5 kg E51 mains-dependent AS 2 with volt-free signalling contact E52 mains-independent AS 4 with volt-free signalling contact, self-charging power supply unit for 5 hours operation in case of a mains failure E53 AS 5 alarm switchgear, mains-independent, 230 V~/ with self-charging power supply 12 V = unit for 10 hours operation in case of 5 VA a mains failure, mains pilot LED, fault indicator lamp, horn-off push button, volt-free contact for hook-up to a control station, ready to be plugged in, with 1.8 m cable and plug. X 29 128 422 0.5 X 29 128 442 0.5 X 00 530 561 1.7 ISO housing IP 41, 190 x 165 x 75 mm Use float switch (E 40) as contactor. Horn see accessories E55 AS 1 alarm switchgear, 230 V~/ in ISO plug housing IP 30, mains-independent, 9 V= with self-charging power supply unit for 5 hours 1.5 VA operation in the case of mains failure, acoustic signal 70 db(a) with circuit breaker and integrated signal transmitter with 3 m connection cable. X 00 533 740 0.9 E 330 Possible application for alarm transmission: Water alarm signal at a water level of only 1 mm (!), by placing the contactor on the floor of rooms at risk of flooding, e.g. the cellar or next to the washing machine in the kitchen or bathroom. KSB washing machine interrupter Alarm triggered, with automatic interruption of power supply to the washing machine if the water level in the collecting tank is too high 230 V AC, 50/60 Hz, max. 16 A resistive load Comprises: -- Housing with socket and plug -- Buzzer -- Automatic re-start -- Contactor with 5 m connection cable X 01318215 0,7 5

Electric Accessories E64 Moisture sensor F 1, as contactor for alarm switchgear AS 0, AS 2 or AS 4, with 3-metre connection cable, max. 40 C, not suitable for steam and condensate. Possible application for alarm transmission: Water alarm signal at a water level of only 1 mm (!), by placing the contactor on the floor of rooms at risk of flooding, e.g. the cellar or next to the washing machine in the kitchen or bathroom. 52 x 21 x 20 mm E70 Horn suitable for indoor and outdoor installation, 12 V= mount in a position where it is protected against direct rain, 105 db(a) enclosure IP 33 1.2 W Ama-Drainer-Box Ident. No. kg X 19 072 366 0,9 X 01 086 547 0.1 6

7

2331.55/4-EN / 1.6.2011 Subject to technical modifications without prior notice.