EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Similar documents
Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS

SEALED THERMAL STORE

Nu-Heat UNDERFLOOR & RENEWABLES

ADVANCE ECB ELECTRIC COMBINATION BOILER

Nu-Heat. options. warm water underfloor heating. design innovation expertise service U N D E R F L O O R

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

warm water underfloor heating installation manual v4b-aug 08 Nu-Heat design innovation expertise service

DIGITAL HOT WATER SOLUTIONS

Standard Assessment Procedure Instantaneous Waste Water Heat Recovery Systems Design Checklist for 'System A' Installation Configuration

ADVANCE ELECTRIC THERMAL STORE

Pressure Boosting Solutions

BOILERMATE A CLASS SP

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

BOILERMATE A CLASS OV

Hamworthy. Powerstock. Calorifiers and Storage Tanks Single and Twin Coils Capacities 160 litres to 995 litres

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Standard Assessment Procedure Instantaneous Waste Water Heat Recovery Systems Design Checklist for Configurations A, B & C

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Advance Stainless Steel Unvented Hot Water Cylinders for Heat Pump Systems. Installation and Commissioning Manual

Baxi Maxflow Combi WM

THERMflow Thermal Store Cylinders

Apricus Solar Hot Water Systems

CUBEflow Thermal Store Tank

Risk Assessment and Control Measures for Household Hot Water Systems

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

heat interface units A BOILER WITHOUT A FLAME

Broag Pressurisation equipment

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Baxi Maxflow Combi FS

Installation and User Instructions HS10U, HS15U.

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1

Where gas is not an option,

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

Unvented Hot Water Criteria

Nu-Heat. SPECIFYING NU-HEAT LoPro Max. A Best Practice Guide for professional installers

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

USERS GUIDE. LOGIC+ Combi 24, 30, 35

For latest prices and delivery to your door visit MyTub Ltd

PULSACOIL A CLASS USER GUIDE. TEL:

EFFICIENCY THERMAL STORAGE SYSTEMS

Logic+ Combi

unistor High performance unvented stainless steel cylinder range

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

unistor High performance unvented stainless steel cylinder range

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

Electronic Dual Cylinder Thermostat Installation Instructions

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller

Air Source Heat Pump Installation and Maintenance Manual

Boiler Replacement Scheme Boiler Installer Form

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Commissioning Pack. Heating and Hot Water Heat Pumps. IMPORTANT DOCUMENTS To Be Kept At All Times. With Equipment. Accredited Ecodan Installer:

UK arotherm Schematics and installation guide

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

Alpha FlowSmart 25 and 50

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

systemate 2000 fully integrated thermal store

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

Link-Up. Solid Fuel Association Guide to Central Heating.

EPU - WM30 EPU - WM 50 EPU - WM100

Alpha SolarSmart 100

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Thermostats & smart controls. neohub+ UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

Control Panel Checklist

User's Instructions. Alpha CB50

Alpha CombiMax 350 and 600

Installation, Operating and Servicing Instructions

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions

Tristor MF. Installation Guide

Understand and apply domestic hot water system installation, commissioning, service and maintenance techniques

Water Heating UK 14 th May 2016

GB24 & GB30. User Manual

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 100 TO 300 LITRE CAPACITY DIRECT AND INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

Vented and Unvented Hot Water Systems

Transcription:

EnergyMasterHP user guide Cylinder for use with NIBE heat pump systems v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

working with you before, during & after your project Nu-Heat Know-How 2 For expert advice call us on 01404 549770

Contents Welcome 04 Operation principle of operation 05 Controls cylinder time & temperature settings 05 Secondary hot water loop 06 Hygiene purge 07 Servicing requirements 08 Maintenance log 09 Product support 11 For more information visit www.nu-heat.co.uk 3

System Ref: Every Nu-Heat system is a custom design. Please record your unique system reference number above for future identification. Welcome This guide is aimed at providing a basic understanding of the EnergyMaster HP cylinder installed at your property. You will find references here to other leaflets such as NIBE s user guide and also the Nu-Heat Underfloor Heating User Guide. Installer details Company: Contact name: Contact telephone no: Address: Contact numbers In the case of breakdowns or for product and installation information always contact your heating engineer or electrician in the first instance. Product support for your heating engineer or electrician is also available from Nu-Heat s Technical Support Department. Tel: 01404 540745. 4 For expert advice call us on 01404 549770

The Nu-Heat EnergyMasterHP cylinder Comprehensive information about the heat pump installation is in the Nu-Heat Handover Pack you should have received from your system installer. OPERATION The EnergyMaster HP cylinders work in the same way as any conventional unvented cylinder. Hot water, heated by the heat pump, is pumped around a coil in the cylinder, and heat is transferred to the domestic water stored in the main body of the cylinder. The significant difference is that the cylinder s heat pump coil has a larger surface area than would be needed for a boiler, and the diameter is greater so as to minimise pressure drop. In certain models there will also be a solar coil, occupying the lower portion of the cylinder. A glycol mix is heated by the solar panels, and is pumped around the solar coil, transferring heat to the domestic water in the main body of the cylinder. CONTROL Cylinder time & temperature settings How long the cylinder is heated for, and the operating temperature, are both managed by the heat pumps controller. This will have been set up during system commissioning, however should it be desirable to change these settings please refer to the heat pump user guide. The Nu-Heat EnergyMaster HP cylinder For more information visit www.nu-heat.co.uk 5

Nu-Heat EnergyPro secondary hot water loop (SHWL) A secondary hot water loop (SHWL) may have been installed to circulate domestic hot water out to the taps and back to the cylinder to provide an instantaneous supply of hot water. Note: the SHWL is not a booster pump and will not increase the flow of hot water to the outlets. Controlling the SHWL There are two possible sizes of pump: 1 The EnergyPro SHWL pump has an integral timer, and thermostat. The hot water loop time clock can be set to suit your requirements for instant hot water. Note that hot water is still available during the off periods although you will have to wait a little longer for the water to run hot. The EnergyPro SHWL with digital display The pump has digital settings indicated by the following icons: ON/OFF Up to 3 switched ON/OFF times can be programmed. It is recommended that the hot water loop pump is controlled from the heat pump controller. If this is done, set the SHWL pump timer on the pump to be ON. TEMPERATURE Maintains a set temperature in the pipework by switching pump on and off. on off THERMAL DISINFECTION Detects temperatures over 68 C and runs the pump for 2 hours irrespective of other settings. Helps to prevent legionella. The return temperature to the cylinder should be 50 C or higher in line with the HSC s Legionnaires Disease: the control of legionella bacteria in water systems Approved Code of Practise and Guidance. The EnergyPro SHWL Plus has a larger pump and separate time clock Note: The thermal disinfection feature can be disabled on heat pump systems. 2 The EnergyPro SHWL Plus pump has a separate timeclock and a pipe thermostat. The pipe thermostat has the temperature in C printed on the dial. Note that the return temperature to the cylinder should be 50 C or higher in line with the HSC s Legionnaires Disease: the control of legionella bacteria in water systems Approved Code of Practise and Guidance. Timing The hot water loop should be timed to run during periods of hot water usage (e.g. in the mornings and evenings). At other times it should be timed off to prevent excess energy usage, which in extreme cases could lead to high running costs. EnergyPro SHWL Plus: turn the pipe thermostat to achieve 50 C return at the cylinder Important The hot water loop should be allowed to run throughout the year. If it is inactive for more than a week then there is a risk of bacteria growth such as legionella. 6 For expert advice call us on 01404 549770

Hygiene purge A high temperature hygiene purge is required against bacterial growth such as legionella. This is either performed by the cylinder immersion, or by an external heat source, e.g. ground source heat pumps have an integral immersion which performs the purge. As part of the system commissioning the hygiene purge will have been set up details of the times set can be found in the Heat Pump Commissioning Procedure. If it is necessary to alter these settings see the Heat Pump User Guide. Note: The immersion heater supplied is fitted with a thermal cut-out if the thermostat in the immersion goes over temperature for any reason it will need to be manually reset. This involves removing the cover the immersion heater must be isolated from the mains before the heat pump or immersion cover is removed. Important: Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air-source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20 C and 45 C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of Legionella bacteria can be found on the WRAS website: www.wras.co.uk. For more information visit www.nu-heat.co.uk 7

Servicing requirements ANNUALLY Nu-Heat EnergyMasterHP cylinder It is important to have the cylinder serviced annually to ensure safe operation and as a requirement of the warranty. To qualify for the warranty service records must be kept on pages 9 11 of this User Guide. Please note: warranties are void without service records and a commissioning certificate (see cylinder label or contact Nu-Heat for confirmation of commissioning). The following should be checked:- Yes No 1 Is the incoming pressure controlled at 3 bar maximum? q q 2 If not has it been reset? q q 3 The DHW expansion vessel must be manitained annually. The charge should be checked with mains water isolated and pressure released, using an accurate pressure gauge, and maintained at 3 bar. Recharge if necessary. Does it hold pressure? q q 4 If not, has it been replaced? q q 5 Is the discharge pipework from the expansion valve and T&P relief valve adequate to safely carry discharge water away? q q 6 If not, has any blockage been cleared? q q 7 Open the pressure relief valve cap on the expansion vessel to check that it can manually discharge water and reseats correctly. Does it discharge water effectively? q q 8 If not, has it been replaced? q q 9 Open the pressure and temperature relief valve cap on the cylinder to check that it can manually discharge water effectively and reseated correctly. Does it discharge water effectively? q q 10 If not, has it been replaced? q q 11 Is the immersion set such that it does not allow the hot water temperature to exceed 60 C? q q 12 If not, have they been reset? q q 8 For expert advice call us on 01404 549770

Maintenance log UPON COMPLETION OF THE ANNUAL CYLINDER SERVICE THE FOLLOWING RECORD MUST BE COMPLETED THE WARRANTY IS DEPENDENT ON SERVICE RECORDS BEING KEPT Service 1 Service 2 Service 3 Service 4 Service 5 Service 6 Service 7 Service 8 Service 9 Service 10 For more information visit www.nu-heat.co.uk 9

Service 11 Service 12 Service 13 Service 14 Service 15 Service 16 Service 17 Service 18 Service 19 Service 20 10 For expert advice call us on 01404 549770

Service 21 Service 22 Service 23 Service 24 Product support For further information on the operation of your EnergyMaster HP cylinder or help with troubleshooting, please register on the Nu-Heat website at www.nu-heat.co.uk. For more information visit www.nu-heat.co.uk 11

Online www.nu-heat.co.uk Follow us @nuheatuk See our videos /nuheatuk Telephone 01404 549770 Nu-Heat UK Ltd I Heathpark House I Devonshire Road I Heathpark Industrial Estate I Honiton I Devon EX14 1SD 12 For expert advice call us on 01404 549770