Engineering Specification

Similar documents
Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

Engineering Specification

Engineering Specification

Engineering Specification

ENGINEERING SPECIFICATIONS

Engineering Specification

Engineering Specification

Engineering Specification

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

GUIDE SPECIFICATIONS AQUARIUS ii

Installation and Service Manual. In-Floor Warming Module external desuperheater for 3rd party air source heat pumps

water to water heat pumps

MAC-120HE-03 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

Installation and Service Manual

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Installation and Service Manual

GT-PW (50YEW) Water-To-Water Series. WATER-TO-WATER PURON SYSTEMS SIZE 010 [10 kw]

SpaceKeeper Console (SKC)

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Call us today! (800)

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

GUIDE SPECIFICATIONS AQUARIUS ii

Nordic Heat Pump Product Guide

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Call us today! (800)

Versatec Specification Catalog

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Installation and Service Manual

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Call us today! (800)

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

*20D082-05NN* 20D082-05NN

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Indoor Air Handlers with Compressors MVS and MVW

Installation and Service Manual

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

SECTION ROTARY-SCREW WATER CHILLERS

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Commercial High-Efficiency Condensing Units

VariCool VAV Engineering Guide

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

Commercial High-Efficiency Condensing Units

Advance Split

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

AVAILABLE WITH ENERGY SAVING ECM MOTOR

R4H4. Product Specifications

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

R4H4. Product Specifications

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

SYSTEM DESIGN REQUIREMENTS

EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

JH Series Installation

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

High Profile Evaporator

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

MEDICAL CHILLER SYSTEMS

Condensing Unit Installation and Operating Instructions

June PRODUCT DESIGN GUIDE Whisperline Console

3 TON Heating Performance Data TON Cooling Performance Data TON Heating Performance Data TON Cooling Performance Data...

C13-Series Engineering Guide

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Submitted to Reference Approval Construction Unit Designation Schedule #

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Liebert CSU3000 Chiller

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Precise Temperature Control; Compact Footprint

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Transcription:

Engineering Specification ATW-65-HACW-P-*T-* Air to Water Heat Pump 60 Hz Maritime Geothermal Ltd. P.O. Box 2555, 170 Plantation Road Petitcodiac, NB E4Z 6H4 (506) 756-8135 info@nordicghp.com www.nordicghp.com 001850SPC-03 ECO 000270 12-Feb-2019

Model Nomenclature Indoor Unit: ATW - 65 - HACW - P - 1T - C - xx Series: ATW = Air To Water Nominal Size: 65 = 051 compressor Function: H = Heating AC = Active Cooling W = domestic hot Water Refrigerant: P = R410a Revision: 01, 02, etc. Indoor Coil: C = Copper coaxial Y = Cupro-Nickel coax & piping Z = Cupro-Nickel coax only Compressor: T = 2 stage scroll Voltage Code: 1 = 208/230-1-60 2 = 208-3-60 4 = 460-3-60 APPLICATION TABLE SERIES SIZE FUNCTION REFRIGERANT VOLTAGE COMPRESSOR INDOOR COIL REVISIONS ATW 65 HACW P 1 2 T 4 C Y Z 03 Matching Outdoor Unit: ACE - 65 - P - 1/6 - SDE - xx Series: ACE = All weather Condenser / Evaporator Nominal Size: 65 = matched to size 65 indoor unit Refrigerant: P = R410a Revision: 01, 02, etc. Fan: D = Direct Drive E = EC motor Air Coil: S = Standard K = Coated APPLICATION TABLE SERIES SIZE REFRIGERANT VOLTAGE AIR COIL FAN REVISIONS Voltage Code: 1/6 = 208/230-1-60 or 220-1-50 ACE 65 P 1/6 S K DE 06 Maritime Geothermal Ltd. has a continuous improvement policy and reserves the right to modify specification data at any time without prior notice. 12-Feb-2019 Page 2 001850SPC-03

Design Features TUV listed for electrical certification 18/20ga satin galvanized cabinet with reinforcing channel stiffeners Powder coat finish Acoustically insulated cabinet (1 and 1/2 thick) Completely insulated heat exchanger and piping Four removable access panels Refrigeration service ports located inside unit (1/4 Schrader) Swing out electrical box for unobstructed access to compressor Component layout allows easy access for service 1 Brass FPT fittings for hydronic connections Copeland Ultratech scroll compressor with start capacitor kit on single phase models Dual grommet mounting system for compressor reduces noise and vibration Suction line accumulator for compressor protection Liquid line filter-dryer & sight glass Two Electronic Expansion Valves (EEVs) Coaxial hydronic heat exchanger, available in CuNi High and low pressure sensors Manual reset high pressure control Suction line temperature sensor Temperature sensors on both water lines Control transformer with resettable breaker or fuse protection Advanced control board with BACNet interface for remote operation and data access including all sensor data and alarm conditions, PWM outputs (or 0-10VDC), configurable analog inputs (0-5VDC or 4-20mA) with onboard 5VDC, 12VDC and 24VDC power supplies. USB port for complete data access including real-time charting, data logging, and diagnostic functionality with manual override operation 2 x 16 LCD display for control and data access; unit may be configured for standalone operation with outdoor reset functionality (requires outdoor temperature sensor accessory) Random start on power up (0-2 minutes) 24VAC output and dry contacts for auxiliary heat, controlled by ATW Double wall Domestic Hot Water desuperheater suitable for potable water connections. Brass head ECM circulator for domestic hot water circuit uses less than half the power of traditional circulating pumps and allows motor replacement without tools 1/2 brass FPT fittings for Domestic Hot Water connections Available Accessories Hydronic buffer tank with 12, 15, or 20kW of electric backup elements Barbed P/T port adapters for heat pump Anti-vibration pad for under unit Compressor sound jacket Secure Start module CuNi heat exchanger Compressor current sensor 12-Feb-2019 Page 3 001850SPC-03

Design Features - Indoor Unit advanced control board with USB interface, outdoor reset, BACnet, data logging, onboard aquastat with sampling routine cabinet completely insulated with 1/2 acoustic insulation access panels for all four sides; serviceable from two sides heavy duty cabinet, constructed of powder coated galvanized components with reinforcing channel stiffeners 1 FPT brass fittings for indoor loop connections LCD display with button interface insulated coaxial heat exchanger; resistant to accidental freezing DHW on/off switch high & low refrigerant access ports provision for powering indoor circulator start capacitor kit standard on all single phase models swing out electrical box for easy access & serviceability brass head ECM domestic hot water circulator pump 4-way reversing valve cooling EEV (Electronic Expansion Valve) desuperheater for domestic hot water heating, with 1/2 FPT brass connections 3-way access valves for connection to outdoor unit sight glass biflow filter-dryer high efficiency Copeland two-stage scroll compressor dual mount compressor for reduced noise and vibration Suction accumulator 12-Feb-2019 Page 4 001850SPC-03

Design Features - Outdoor Unit minimal components in outdoor unit, for maximum component life and ease of service electrical box contains only connection terminal strips visors protect motors from water ingress and immobilization from freezing EC (electronically commutated) fan hub motors, for full variable speed operation and maximum energy efficiency side cover protects refrigerant pipes & wiring connection point heavy duty cabinet, constructed of powder coated galvanized components swing out fan panel for easy access & serviceability mounting grommets for vibration isolation air coil with heavy duty fins, installed at slant for most effective condensate runoff and no drip tray where condensate could re-freeze intelligent defrost logic eliminates unnecessary defrosts and ensures complete defrost each time heating EEV (Electronic Expansion Valve) with reverse cycle bypass outdoor temperature sensor reads out on indoor unit 12-Feb-2019 Page 5 001850SPC-03

Dimensions Note: ACE rev 04 shown. Previous revision 03 has 1 fan. Please confirm current revision when ordering. 12-Feb-2019 Page 6 001850SPC-03

Dimensions Note: ACE rev 04 shown. Previous revisions 03 has 1 fan. Please confirm current revision when ordering. 12-Feb-2019 Page 7 001850SPC-03

Specifications Electrical Information Indoor Outdoor Maximum Minimum Code Power Supply Compressor FLA MCA Circulator Unit Fuse/Breaker Wire Size V-ø-Hz MIN MAX RLA LRA Max A Max A Amps Amps Amps ga 1 208/230-1-60 187 253 11.7 58 3.0 1.6 17.1 20.0 30 #10-2* 2 208-3-60 187 229 6.5 55 3.0 1.6 11.9 13.5 20 #12-3* 4 460-3-60 414 506 3.5 28 3.0 1.6 8.9 9.8 15 #14-4 *one additional conductor required if connecting 115VAC circulators to unit. Shipping Information WEIGHT DIMENSIONS in (cm) ITEM lb. (kg) L W H ATW-65 Indoor Unit 334 (151) 34 (86) 34 (86) 35 (89) ATW-65 Outdoor Unit 295 (134) 36 (91) 70 (178) 56 (142) Refrigerant Charge MODEL lb kg Refrigerant Oil Type ATW-65 10.0 4.5 R410a POE - Oil capacity is marked on the compressor label. - Refrigerant charge is subject to revision; actual charge is indicated on the unit nameplate. Indoor Unit Sound Levels (dba)* MODEL 1 ft distance 3 ft distance ATW-65 55.7 53.0 * With all doors installed. Outdoor Unit Sound Levels (dba)* 1 ft distance 3 ft distance 5 ft distance 10 ft distance MODEL Front Side Front Sides Front Sides Front Sides ATW-65 70.3 62.9 65.9 60.5 62.2 58.1 56.6 54.0 * At maximum fan speed. This occurs in heating mode, or in cooling mode with outdoor greater than ~27 C. Operating Temperature Limits Loop Mode Parameter ( F) ( C) Note Heating Minimum ELT 60 15 Reduce flow if necessary during startup. Heating Maximum LLT 120 49 Indoor Cooling Minimum LLT 41 5 Water system (no antifreeze). Cooling Minimum LLT 32 0 Antifreeze system. Adequate freeze protection required. Cooling Maximum ELT 80 27 Outdoor Heating Minimum EAT -7-22 ACE Outdoor Unit automatically stops compressor below this temp. Cooling Maximum EAT 120 49 ACE Outdoor Unit automatically stops compressor above this temp. * Values in this table are for rated liquid flow values. 12-Feb-2019 Page 8 001850SPC-03

Loop Pressure Drop Data 15% Methanol 35% prop. glycol Water 104 F Water 50 F 15% Methanol 32 F 35% 32 F prop. ATW- 65 gpm L/s psi kpa psi kpa psi kpa psi kpa 6 0.38 1.1 7.6 1.2 8.3 1.3 9.0 1.7 12 7 0.44 1.4 10 1.5 10 1.8 12 2.4 16 8 0.50 1.8 12 1.9 13 2.2 15 2.9 20 9 0.57 2.1 14 2.3 16 2.7 19 3.6 24 10 0.63 2.4 17 2.6 18 3.3 23 4.3 30 11 0.69 2.9 20 3.2 22 4 28 5.3 36 12 0.76 3.6 25 3.9 27 4.6 32 6.0 42 13 0.82 4.1 28 4.4 30 5.2 36 6.8 47 14 0.88 4.7 32 5.0 34 5.8 40 7.6 53 15 0.95 5.5 38 5.7 39 6.5 45 8.5 59 16 1.01 6.3 43 6.5 45 7.3 50 9.6 66 Standard Capacity Ratings The tables show the heat pump performance at the standard rating conditions specified in AHRI standard 550/590 with Addendum 1, September 2017. There is currently no AHRI certification program for air to water heat pumps; therefore, the blue AHRI CERTIFIED mark is not applicable to any manufacturer s air to water heat pumps. All data is for 60 Hz operation with water as the indoor loop fluid. METRIC Standard Capacity Ratings: HEATING Model Loop Flow (gpm) ΔP (psi) ATW-65 14.0 4.7 LLT 105 F 120 F Outdoor Air Temp Input Energy (W) Capacity (Btu/hr) COP H 47 F 3600 51,500 4.19 17 F 4070 33,900 2.44 47 F 4270 49,800 3.42 17 F 4790 33,800 2.11 Standard Capacity Ratings: HEATING (METRIC) Model Loop Flow (L/s) ΔP (kpa) ATW-65 0.88 32 LLT 41 C 49 C Outdoor Air Temp Input Energy (W) Capacity (W) COP H 8 C 3600 15,100 4.19-8 C 4070 9,940 2.44 8 C 4270 14,600 3.42-8 C 4790 9,890 2.11 Standard Capacity Ratings: COOLING Standard Capacity Ratings: COOLING (METRIC) Model Loop Flow (gpm) ΔP (psi) ELT Outdoor Air Temp Input Energy (W) Capacity (Btu/hr) ATW-65 14.0 5.0 54 F 95 F 4080 41,000 EER COP C 10.1 2.96 Model Loop Flow (gpm) ΔP (psi) ELT Outdoor Air Temp Input Energy (W) Capacity (W) ATW-65 0.88 34 12 C 35 C 4080 12,000 EER COP C 10.1 2.96 12-Feb-2019 Page 9 001850SPC-03

Performance Tables ATW-65-HACW-P-1T R410a, 60 Hz, ZPS51K5E-PFV HEATING Outdoor Air Temperature OUTDOOR ELECTRICAL INDOOR Evaporating Heat Absorbed Temperature (Btu/hr) Compressor Current (A) Input Power (W) ELT Condensing Liquid Flow Temperature (gpm) LLT Delta T Heating (Btu/hr) -5 F -16 F 7,600 20.7 4730 102 F 110 F 3 F 23,400 1.45 5 F -8 F 13,600 19.3 4410 101 F 109 F 4 F 28,300 1.88 15 F 1 F 19,200 17.8 4100 100 F 109 F 5 F 32,900 2.35 25 F 9 F 24,800 17.1 3950 100 F 109 F 5 F 37,900 2.81 14 105 F 35 F 17 F 31,700 15.5 3620 99 F 109 F 6 F 43,700 3.55 45 F 26 F 38,100 15.5 3610 98 F 108 F 7 F 50,100 4.07 55 F 34 F 45,100 15.4 3570 97 F 108 F 8 F 56,900 4.68 65 F 43 F 52,300 15.2 3490 96 F 108 F 9 F 63,900 5.37-5 F -16 F - - - - - LLT is limited to 105 F at 5 F -8 F - - - - - these outdoor temperatures 15 F 1 F 17,500 20.8 4830 115 F 124 F 5 F 32,800 2.05 25 F 9 F 22,400 20.0 4650 115 F 124 F 5 F 37,600 2.39 14 120 F 35 F 17 F 28,600 18.2 4270 114 F 123 F 6 F 42,800 2.94 45 F 26 F 34,200 18.2 4270 113 F 123 F 7 F 48,500 3.33 55 F 34 F 40,500 18.2 4250 112 F 123 F 8 F 54,700 3.77 65 F 43 F 47,100 18.1 4190 111 F 123 F 9 F 61,000 4.27 COPH COOLING Outdoor Air Temperature Condensing Temperature Heat Rejected (Btu/hr) Compressor Current (A) Input Power (W) ELT Evaporating Liquid Flow Temperature (gpm) LLT Delta T Cooling (Btu/hr) 50 F 62 F 70,900 11.5 2580 39 F 45 F 9 F 62,500 24.3 7.11 60 F 72 F 64,500 12.4 2830 39 F 46 F 8 F 55,200 19.5 5.72 70 F 83 F 60,600 13.6 3130 40 F 47 F 7 F 50,300 16.0 4.70 80 F 93 F 57,800 15.0 3450 40 F 47 F 7 F 46,400 13.4 3.94 54 F 14 90 F 104 F 55,800 16.9 3860 40 F 48 F 6 F 43,000 11.1 3.26 100 F 114 F 53,400 18.9 4310 40 F 48 F 6 F 39,100 9.1 2.66 110 F 125 F 51,400 21.4 4870 40 F 49 F 5 F 35,100 7.2 2.11 120 F 135 F 49,400 24.1 5460 41 F 50 F 4 F 31,100 5.7 1.67 EER COPC METRIC HEATING (METRIC) Outdoor Air Temperature OUTDOOR ELECTRICAL INDOOR Evaporating Heat Absorbed Temperature (W) Compressor Current (A) Input Power (W) ELT -21 C -27 C 2,230 20.7 4730 39 C 43 C Condensing Liquid Flow Temperature (L/s) LLT Delta T Heating (W) -4 C -13 C 7,250 17.1 3950 38 C 43 C 3.0 C 11,100 2.81 0.88 40.5 C 2 C -8 C 9,290 15.5 3620 37 C 43 C 3.5 C 12,800 3.55 COPH 1.9 C 6,870 1.45-15 C -22 C 3,980 19.3 4410 38 C 43 C 2.2 C 8,300 1.88-9 C -18 C 5,630 17.8 4100 38 C 43 C 2.6 C 9,640 2.35 7 C -4 C 11,200 15.5 3610 37 C 42 C 4.0 C 14,700 4.07 13 C 1 C 13,200 15.4 3570 36 C 42 C 4.5 C 16,700 4.68 18 C 6 C 15,300 15.2 3490 36 C 42 C 5.1 C 18,700 5.37-21 C -27 C - - - - - -15 C -22 C - - - - - LLT is limited to 40.5 C at these outdoor temperatures -9 C -18 C 5,140 20.8 4830 46 C 51 C 2.7 C 9,610 2.05-4 C -13 C 6,560 20.0 4650 46 C 51 C 3.0 C 11,000 2.39 0.88 49 C 2 C -8 C 8,370 18.2 4270 46 C 51 C 3.4 C 12,500 2.94 7 C -4 C 10,000 18.2 4270 45 C 51 C 3.9 C 14,200 3.33 13 C 1 C 11,900 18.2 4250 45 C 51 C 4.3 C 16,000 3.77 18 C 6 C 13,800 18.1 4190 44 C 50 C 4.9 C 17,900 4.27 COOLING (METRIC) Outdoor Air Temperature Condensing Temperature Heat Rejected (W) Compressor Current (A) Input Power (W) ELT Evaporating Liquid Flow Temperature (L/s) 4 C LLT Delta T Cooling (W) EER COPC 7 C 5.0 C 18,300 24.3 7.11 19.5 16.0 13.4 11.1 9.1 7.2 5.7 10 C 17 C 20,800 11.5 2580 16 C 22 C 18,900 12.4 2830 4 C 8 C 4.4 C 16,200 5.72 21 C 28 C 17,800 13.6 3130 4 C 8 C 4.0 C 14,700 4.70 27 C 34 C 16,900 15.0 3450 4 C 9 C 3.7 C 13,600 3.94 12 C 0.88 32 C 40 C 16,300 16.9 3860 4 C 9 C 3.4 C 12,600 3.26 38 C 46 C 15,700 18.9 4310 5 C 9 C 3.1 C 11,500 2.66 43 C 52 C 15,100 21.4 4870 5 C 9 C 2.8 C 10,300 2.11 49 C 57 C 14,500 24.1 5460 5 C 10 C 2.5 C 9,100 1.67 12-Feb-2019 Page 10 001850SPC-03

Wiring Diagram (208/230-1-60) 12-Feb-2019 Page 11 001850SPC-03

Electrical Box Layout (208/230-1-60) 12-Feb-2019 Page 12 001850SPC-03

Wiring Diagram (208-3-60) 12-Feb-2019 Page 13 001850SPC-03

Electrical Box Layout (208-3-60) 12-Feb-2019 Page 14 001850SPC-03

Wiring Diagram (460-3-60) 12-Feb-2019 Page 15 001850SPC-03

Electrical Box Layout (460-3-60) 12-Feb-2019 Page 16 001850SPC-03

ACE-65/75 Wiring Diagram 12-Feb-2019 Page 17 001850SPC-03

12-Feb-2019 Page 18 001850SPC-03

12-Feb-2019 Page 19 001850SPC-03

BACnet Interface The BACnet interface is an MS/TP connection via RS-485 twisted pair. If connecting multiple units to one RS-485 connection point, connect the signal cable from the master controller to the first unit. Connect the second unit to the first unit (in same connector), connect the third unit to the second unit, and so on until all units are connected. Remove the TERM jumper (located just above the BACnet connector on control board) from all units except the last one. The connector on the control board is a three wire removable screw connector. The signals are as follows: A: Communications line (+) (right pin) B: Communications line (-) (middle pin) C: Ground connection (left pin) Vendor: Maritime Geothermal Ltd. Vendor ID: 260 Model Name: MGT GEN2 Control Board The following parameters can be set via the LED Display Configuration Menu or via the PC APP Configuration Page. 1) Baud rate 2) Instance number 3) MAC address The data is available regardless of the selected control method. In order to control the unit via the BACnet interface, set the Control Source to BACnet either by using the PC APP configuration page or the display menus. The following tables provide a list of the objects applicable to this model series, along with a description of each. Note that there may be other objects available that do not apply to this model. BACnet OBJECTS - CONTROL SIGNALS (READ/WRITE) Name Data Type ID Property Description SYSTEM_O Binary Value BV2 Present Value Switch to cooling mode. Inactive=HEATING, Active=COOLING SYSTEM_Y1 Binary Value BV3 Present Value N/A SYSTEM_Y2 Binary Value BV4 Present Value N/A SYSTEM_W2 Binary Value BV5 Present Value N/A SYSTEM_G Binary Value BV6 Present Value N/A SYSTEM_AR Binary Value BV7 Present Value N/A SYSTEM_Y1A Binary Value BV0 Present Value Demand for water heating mode (active is on) SYSTEM_Y2A Binary Value BV1 Present Value Demand for stage 2 water heating mode (active is on) BACnet_Units Binary Value BV9 Present Value Select the units to use for the BACnet objects Note: object names may be subject to change without prior notice. BACnet OBJECTS - OPERATION MODE Description (Read Only) Name Data Type ID Present Value Description Operation Mode Analog Value AV5 - Integer value represents operating mode. 2 Hydronic heating 3 Hydronic cooling 11 Hydronic heating off 12 Hydronic cooling off Note: Object is type Analog Value but value will always be an integer value. Note: Objects may be subject to change without prior notice. 12-Feb-2019 Page 20 001850SPC-03

BACnet OBJECTS - DATA (Read Only) Name ID Property Units Description Data Type Analog Input AI0 (Comp1_Current) AI0 Present Value Amps Compressor current draw (AI0) - requires accessory AI1 (Comp2_Current) AI1 Present Value User User defined (0-5VDC or 4-20mA) AI2 AI2 Present Value User User defined (0-5VDC or 4-20mA) AI3 AI3 Present Value User User defined (0-5VDC or 4-20mA) AI4 (CTS) AI4 Present Value degf (degc) Cold tank temperature from sensor - requires accessory AI5 (HTS) AI5 Present Value degf (degc) Hot tank temperature from sensor - requires accessory LPS1 AI6 Present Value PSIG (kpa) Low pressure value (suction pressure) HPS1 AI7 Present Value PSIG (kpa) High pressure value (discharge pressure) EVAP1 AI8 Present Value degf (degc) Evaporating Temperature COND1 AI9 Present Value degf (degc) Condensing Temperature Suction Line 1 AI10 Present Value degf (degc) Suction line temperature Superheat 1 AI11 Setpoint Value degf (degc) Superheat EEV1 Position AI12 Present Value % EEV1 position (% open) LPS2 AI13 Present Value PSIG (kpa) N/A HPS2 AI14 Present Value PSIG (kpa) N/A EVAP2 AI15 Present Value degf (degc) N/A COND2 AI16 Present Value degf (degc) N/A Suction Line 2 AI17 Present Value degf (degc) N/A Superheat 2 AI18 Setpoint Value degf (degc) N/A EEV2 Position AI19 Present Value % EEV2 position (% open) Outside Ambient AI20 Present Value degf (degc) Outdoor Ambient temperature O_IN AI21 Present Value degf (degc) N/A O_OUT AI22 Present Value degf (degc) N/A I_IN AI23 Present Value degf (degc) Indoor IN temperature I_OUT AI24 Present Value degf (degc) Indoor OUT temperature Data Type Analog Value PWM_IN AV0 Present Value % PWM input (from external source) PWM1 (OD Fan) AV1 Present Value % PWM output value (spare) PWM2 AV2 Present Value % PWM output value (spare) PWM3 (OV2) AV3 Present Value % OV2 - PWM or 0-10VDC for Outdoor Loop water valve PWM4 (IV2) AV4 Present Value % IV2 - PWM or 0-10VDC for Indoor Loop water valve Operation Mode AV5 Present Value N/A Unit operation mode - refer to Operation Mode Table Data Type Binary Output STAGE1 BO0 Present Value N/A Compressor contactor STAGE2 BO1 Present Value N/A Compressor stage 2 solenoid ICR (Indoor Circ) BO2 Present Value N/A Indoor circulator control DO0 (OV1) BO3 Present Value N/A N/A DO1 (IV1)) BO4 Present Value N/A IV1 (to 24VAC Indoor Loop water valve) DO2 (HYD_AUX) BO5 Present Value N/A Hydronic Auxiliary DO3 (AUX_ONLY) BO6 Present Value N/A Hydronic Auxiliary Only (without compressor) PHS1 BO7 Present Value N/A N/A PHS2 BO8 Present Value N/A N/A Data Type Binary Value CONTROLS (LOC/REM) BV9 Present Value N/A Control Indicator, 0 = Local (manual override), 1 = Remote Outdoor Flow BV10 Present Value N/A N/A Indoor Flow BV11 Present Value N/A Indoor Loop flow switch - requires accessory Phase Monitor1 BV12 Present Value N/A Phase Monitor Stage 1 - requires accessory Phase Monitor2 BV13 Present Value N/A N/A Comp Monitor1 BV14 Present Value N/A N/A Comp Monitor2 BV15 Present Value N/A N/A Note: available objects may be subject to change without prior notice. 12-Feb-2019 Page 21 001850SPC-03

BACnet OBJECTS - ALARM Descriptions (Read Only) Name Data Type ID Description AI0 (Comp1 Current) Analog Input AI0 Stage 1 Status alarm (Start / Stop Failure) - requires accessory AI1 (Comp2 Current) Analog Input AI1 N/A LPS1 Analog Input AI6 Low pressure alarm HPS1 Analog Input AI7 High pressure alarm LPS2 Analog Input AI13 N/A HPS2 Analog Input AI14 N/A Outdoor Flow Binary Value BV10 N/A Indoor Flow Binary Value BV11 Indoor loop flow alarm - requires accessory Phase Monitor1 Binary Value BV12 Phase Monitor alarm - requires accessory Phase Monitor2 Binary Value BV13 N/A Comp Monitor1 Binary Value BV14 N/A Comp Monitor2 Binary Value BV15 N/A Name ID BIT # DECIMAL VALUE* Permanent Alarms 1 AV6 - - Bit description is given below. Description (Present Value) 0 1 Master permanent alarm (occurs when any alarm occurs) 1 3 Low pressure heating mode alarm (suction pressure) 2 5 Low pressure cooling mode alarm (suction pressure) 3 9 High pressure heating mode alarm (discharge pressure) 4 17 High pressure cooling mode alarm (discharge pressure) 5 33 Loss of charge alarm 6 65 Phase monitor alarm - requires accessory 7 129 Compressor monitor alarm - N/A 8 257 Status alarm - N/A 14 16,385 N/A Permanent Alarms 2 AV7 - - N/A (Present Value) 15* 32,769 Indoor loop flow alarm - requires accessory Note: Permanent Alarm objects are type Analog Value but values are bit coded and may be decoded as such (integer value). Note * : Value is for a single alarm and reference only. Value includes + 1 for Master Alarm Note: Objects may be subject to change without prior notice. 12-Feb-2019 Page 22 001850SPC-03

BACnet OBJECTS - FAULT Descriptions (Read Only) Name Data Type ID Description AI4 (Cold Tank) Analog Input AI0 Cold tank temperature sensor faulty or disconnected - requires accessory AI5 (Hot Tank) Analog Input AI1 Hot tank temperature sensor faulty or disconnected - requires accessory LPS1 Analog Input AI6 Low pressure sensor faulty or disconnected HPS1 Analog Input AI7 High pressure sensor faulty or disconnected LPS2 Analog Input AI13 N/A HPS2 Analog Input AI14 N/A Suction Line1 Analog Input AI10 Suction line 1 temperature sensor faulty or disconnected. Suction Line2 Analog Input AI17 N/A Outside Ambient Analog Input AI20 Outside temperature sensor faulty or disconnected O_IN Analog Input AI21 N/A O_OUT Analog Input AI22 N/A I_IN Analog Input AI23 Indoor IN temperature sensor faulty or disconnected. I_OUT Analog Input AI24 Indoor OUT temperature sensor faulty or disconnected. Name ID BIT # DECIMAL VALUE* Description Board Faults AV8 - - Bit description is given below. 0 1 Digital inputs 1 2 Digital outputs 2 4 PWM outputs 3 8 Analog to digital conversion 4 16 Real time clock 5 32 EEPROM memory 6 64 Menu buttons 7 128 LCD Display Sensor Faults AV9 - - Indicates sensor failures. Bit description is given below. 0 1 Suction line 1 temperature 1 2 N/A 2 4 Outdoor Ambient temperature 3 8 Calibration temperature 4 16 Indoor IN temperature 5 32 Indoor OUT temperature 6 64 N/A 7 128 N/A 8 256 N/A 9 512 N/A Note: Board and Sensor Fault objects are type Analog Value but values are bit coded and may be decoded as such (integer value). Note * : Value is for a single fault and reference only. Note: Objects may be subject to change without prior notice. 12-Feb-2019 Page 23 001850SPC-03

Engineering Guide Specifications General The air source hydronic heat pump shall consist of an indoor unit, containing the compressor and all electronics, and an outdoor unit containing only an air coil, fan, and expansion valve. The unit shall be capable of heating or cooling the indoor hydronic loop, for space heating or air conditioning purposes. The unit shall be listed by a nationally recognized safety-testing laboratory (NRTL), such as ETL, TUV, UL or CSA. The unit shall be rated in accordance with applicable standards of the Air Conditioning, Heating, and Refrigeration Institute / International Standards Organization (AHRI/ISO) and/or Canadian Standards Association (CSA). The heat pump, as manufactured by Maritime Geothermal, Petitcodiac, New Brunswick, shall be designed to operate correctly within the air and liquid temperature ranges specified on the Operating Temperature Limits table in this engineering specification document. Factory Quality Each unit shall be run tested at the factory with water circulating in indoor loop and outdoor unit connected. Quality control system checks shall include: computerized nitrogen pressurized leak test, evacuation of refrigeration circuit to sustained vacuum, accurate system charge, detailed heating and cooling mode tests, and quality cross check all operational and test conditions to pass/fail criteria. Units tested without water or air flow are not acceptable. The units shall be warranted by the manufacturer against defects in materials and workmanship in accordance with the warranty section at the end of this document. Optional extended factory warranty coverage may be available. Cabinet Each unit shall be enclosed in a sheet metal cabinet. Cabinet shall be constructed of powder coated galvanized sheet metal of minimum 20 gauge. Sheet metal gauge shall be higher where structurally required. Design and construction of cabinet shall be such that it is rigid and passes the CSA/UL Loading Test requirements (200 lb roof test). All panels shall be lined with minimum 1/2 inch [12.7 mm] thick acoustic type glass fiber insulation. All insulation shall meet the fire retardant provisions of NFPA 90A. This material shall also provide acoustical benefit. The indoor unit must have a minimum of four access panels for serviceability of the compressor compartment. Units having only one access panel to compressor/heat exchangers/expansion device/refrigerant piping shall not be acceptable. The electrical box shall have separate holes and knockouts for entrance of line voltage and low voltage control wiring. All factory-installed wiring passing through factory knockouts and openings shall be protected from sheet metal edges at openings by plastic grommets. Refrigerant Circuit All units shall contain only one refrigerant circuit, containing a hermetic motor scroll compressor, Electronic Expansion Valves (EEVs), coaxial heat exchanger, factory installed high and low pressure sensors, manual reset high pressure switch, service ports, liquid line filter-dryer, sight glass, and suction accumulator. Compressors shall be specified for heat pump duty with internal isolation consisting of rubber vibration isolators and mounting plate with rubber vibration isolators. Compressor motors shall have internal high temperature overload protection. The water to refrigerant heat exchanger shall consist of a steel outer jacket with twisted copper inner tube, designed and certified for 600 psig [4136 kpa] working pressure on the refrigerant side and 450 psig [3108 kpa] on the water side. Heat exchangers headered together in parallel shall use a reverse-return or symmetrical arrangement on the water side and symmetrical arrangement on the refrigerant side to ensure even flow splitting. Heat exchangers shall be insulated over all of their outside surface with minimum 3/8 thick closed cell insulation. Insulation consisting of 1/8 closed-cell insulating tape shall not be acceptable. The electronic expansion valves shall be of stepper-motor rather than pulsing type, and shall provide proper superheat control over the unit s operating range with minimal deviation from superheat setpoint. Superheat shall be determined through the suction pressure-temperature method. Externally mounted pressure controlled water regulating flow valves or thermostatic expansion valves (TXV s) in place of electronic expansion valves are not acceptable. The suction accumulator shall be insulated with minimum 3/8 thick closed cell insulation to prevent condensation. The accumulator s internal oil return port shall be sized properly for the unit s operating range. To ensure proper oil return, suction accumulator shall not be oversized. The unit shall be equipped with a double wall desuperheating heat exchanger, to heat domestic hot water with a small percentage of the unit s capacity while operating in space heating or cooling modes. A bronze head ECM circ pump and a temperature control to turn it off at 140 F / 60 C shall be built in. 12-Feb-2019 Page 24 001850SPC-03

Piping and Connections The indoor unit shall have one set of primary water in and water out connections. The primary connection type shall be 1 nominal female National Pipe Thread (NPT). All water connectors shall be rigidly mounted to cabinet with corrosion resistant fasteners to prevent relative movement. All water connectors shall be constructed of copper or brass material for corrosion resistance. All internal water and refrigerant piping shall be insulated with minimum 3/8 thick closed cell insulation. Insulation consisting of 1/8 closed-cell insulating tape shall not be acceptable. Desuperheater connections for domestic hot water shall be 1/2 NPT, rigidly mounted to cabinet with corrosion resistant fasteners to prevent relative movement. All water connectors shall be constructed of copper or brass material for corrosion resistance and potable water safety. The indoor unit shall be provided charged with sufficient refrigerant for the installed system to operate properly with up to 20 ft of interconnecting line set. The indoor unit shall be equipped with two 3-way refrigerant access valves for connection to the outdoor unit, so that refrigerant does not need to be removed from the system during installation. Electrical Controls and safety devices shall be factory wired and mounted within the unit. Controls shall include 24 volt alternating current (24VAC) activated compressor contactor, and 24VAC 100VA transformer with built in circuit breaker or fused on both primary and secondary sides. A terminal strip with screw in terminals shall be provided for field control wiring. Units shall be name-plated for use with time delay fuses or circuit breakers. Unit controls shall be 24VAC and provide heating as required by the remote thermostat or controller, or on-board controller. Unit shall provide remote fault indication to the control system via serial communications as well as provide fault messages on the front panel LCD display. Unit Control The control system shall have the following features: 1. Anti-short cycle time delay on compressor operation. Time delay shall be a minimum of 5 minutes, for both thermostat demand and safety control reset starts. An override shall be provided to disable this delay for unit commissioning and testing purposes. 2. Random compressor start delay of 0-120 seconds on unit power up to facilitate starting multiple units after a power failure. 3. Compressor shutdown for high or low refrigerant pressures, Loss of Charge (LOC), optional low flow conditions, and for optional phase protection faults on three phase models. 4. Automatic intelligent reset: after a trip, unit shall automatically restart when short cycle delay expires if the fault has cleared. Should a fault reoccur 2 times sequentially then permanent lockout shall occur, requiring cycling of the power to the unit in order to reset. 5. Manual reset high pressure in case of electronic board failure. 6. The low pressure shall not be monitored for the first 90 seconds after a compressor start to prevent nuisance safety trips. 7. 2 x 16 backlit Liquid Crystal Display (LCD) and four buttons provide basic configuration and data access. Unit may be configured for stand alone operation. 8. Universal Serial Bus (USB) port for full data access and diagnostic information, including manual override of all inputs and outputs, data-logging and real-time charting. Maritime Geothermal works continually to improve its products. As a result, the design and specifications of any product may be changed without notice. Please contact Maritime Geothermal at 1-506-756-8135 or visit www.nordicghp.com for latest design and specifications. Purchaser s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any commercial contract or other agreement between any parties, but are merely Maritime Geothermal s statement of opinion regarding its products. 12-Feb-2019 Page 25 001850SPC-03

LIMITED RESIDENTIAL WARRANTY MARITIME GEOTHERMAL LTD. warrants that the heat pumps manufactured by it shall be free from defects in materials and workmanship for a period of (5) FIVE YEARS after the date of installation or for a period of (5) FIVE YEARS AND (60) SIXTY DAYS after the date of shipment, whichever occurs first. In addition MARITIME GEOTHERMAL LTD. warrants that the compressor shall be free of defects in materials and workmanship for an additional period of (2) TWO YEARS from said date. MARITIME GEOTHERMAL LTD. shall, at its option repair or replace any part or parts covered by this warranty which shall be returned to MARITIME GEOTHERMAL LTD., transportation charges prepaid, which, upon examination proves to be defective in materials or workmanship. Replacement or repaired parts and components are warranted only for the remaining portion of the original warranty period. This warranty is subject to the following conditions: 1. The NORDIC heat pump must be properly installed and maintained in accordance with MARITIME GEOTHERMAL LTD.'s installation and maintenance instructions. 2. The installer must complete the Installation Data Sheet, have it endorsed by the owner and return it to Maritime Geothermal Ltd. within 21 days of installation of the unit. 3. It is the responsibility of the building or general contractor to supply temporary heat to the structure prior to occupancy. These heat pumps are designed to provide heat only to the completely finished and insulated structure. Start-up of the unit shall not be scheduled prior to completion of construction and final duct installation for validation of this warranty. 4. It is the customer's responsibility to supply the proper quantity and quality of water. If the heat pump, manufactured by MARITIME GEOTHERMAL LTD., fails to conform to this warranty, MARITIME GEOTHERMAL LTD.'s sole and exclusive liability shall be, at its option, to repair or replace any part or component which is returned by the customer during the applicable warranty period set forth above, provided that (1) MARITIME GEOTHERMAL LTD. is promptly notified in writing upon discovery by the customer that such part or component fails to conform to this warranty. (2) The customer returns such part or component to MARITIME GEOTHERMAL LTD., transportation charges prepaid, within (30) thirty days of failure, and (3) MARITIME GEOTHERMAL LTD.'s examination of such component shall disclose to its satisfaction that such part or component fails to meet this warranty and the alleged defects were not caused by accident, misuse, neglect, alteration, improper installation, repair or improper testing. 12-Feb-2019 Page 26 001850SPC-03