Manual Zhengzhou Winsen Electronics Technology Co., Ltd

Similar documents
ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V1.1. Zhengzhou Winsen Electronics Technology Co., Ltd

M004 combustible gas module

Air-Quality Detection Module. User s Manual

Air-Quality Detection Module. User s Manual

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

MEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.

Catalytic Gas Sensor. (Model: MC113/ MC113C) Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

Ozone Gas Sensor. (Model:MQ131 High Concentration) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co.

Smoke Sensor. (Model:MQ-2) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

Ammonia Gas Sensor. (Model:MQ137) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

Air-Quality Gas Sensor (Model: MP905) Manual. Version:1.1. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

Catalytic Flammable Gas Sensor. (Model: MC105B) User s Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

Air-Quality Gas Sensor (Model:MP503) Manual. Version:1.3. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

TC100N. Fixed Gas Detector Operation Manual

E1000 Portable gas detector

IMR EX610. Portable Gas Detector. Operation Manual

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

KAE Gas Alarm Operation Manual

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

GD Series Gas Alarm Operation Manual

QD6310. Fixed Gas Detector Operation Manual

Laser Particle Sensor Module PM2009

Model 4880 Status Output Display Module Manual

RFID Card Access Control Unit. Operating Instructions

FIS SMART SENSOR U (Draft 1) June 25, 2001

EST User Manual. (Please read this manual carefully before using)

Laser Distance Sensor Type M Analog-Output

Premier Hazard STC Instructions

SCR100 User Manual. Version:1.1 Date:Dec 2009

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Special Maintenance Manual for Induction Cooker - 220V/240V Version

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE

Danfoss gas detection units

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Room thermostats with LCD for wall mounting

SCAN20 Series Gas Detection Controller

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Door Release Power Supply

KAB Gas Alarm Operation Manual

Installation/Owner s Manual Models 1504 / 1506

IMR IX176 Portable Gas Detector User Manual

Carbon Monoxide Transmitter

ACS-30-EU-EMDR- 10-MOD

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

ELIMINOSTAT DC-ESR-CL-S2

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

TECH SHEET - DO NOT DISCARD PAGE 1 DIAGNOSTIC GUIDE

Flammable and Toxic Gas Detection

CO2Sensor Basic / ES 999

Model Number Structure

Air Purifier. Purificateur d airs. Purificador de aire

RAM3 Remote Alarm Module

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

HOBOT. HOBOT-168 Glass Cleaning Robot User s Manual

Secure WANDERING INSTALLATION AND USAGE GUIDE

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

PID Temperature Controller. ITC-100 User Manual. Version 2.0s. Inkbird Tech. Co., Ltd.

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

Sapphire Series TSVW & TWWS Chillwater Digital Thermostats

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Infrared Carbon Dioxide Sensor Module CM1106SL

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

Smoke Detector Demo Reference Solution

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual

LM40 Medium Intensity Aviation Obstruction Light

Safety Function: Single-beam Area Access Control (AAC)

PTE0705 Electric Fence Monitor

Plug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

General Specifications

Danfoss gas detection units

AM 213 Installation Introduction

Intelligent Wireless GSM Alarm System

Booster Power Supply Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Electro Optical Components, Inc.

Laser Particle Sensor Module PM2008M

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System

WIRING DIAGRAM AND INSTRUCTIONS

Snifter ATEX22 VERSION. User Manual. Distributor

SENSA MRE DDM MR

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

Laser Particle Sensor Module PM2008M

Installation and Wiring 1.

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

SITESTAR CABINET DESCRIPTION

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

HX-80NRAM. High Mount Outdoor Detector

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Transcription:

ZP04 Flammable Gas Detection Module Manual Zhengzhou Winsen Electronics Technology Co., Ltd

Statement This manual s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can t spread through electronic, copying, record ways. Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, change the components inside of the sensor, we shall not be responsible for the loss. The specific such as color, appearance, sizes &etc., please in kind prevail. We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users comments on optimized using way are welcome. Please keep the manual properly, in order to get help if you have questions during the usage in the future. Zhengzhou Winsen Electronics Technology CO., LTD.

ZP04 Module ZP04 adopts semiconductor sensor, which has basic functions of household gas leak alarm: electric power light, warm-up light, fault lamp, output signal of alarm lamp; buzzer, relay, output signal of electromagnetic valve; input signal of testing button, canceling warm-up button input. This module can be used for complete device development of household gas leak alarm.. Parameters Detection Gas Natural gas, LPG, Artificial coal Gas Detection Range ~ 5%LEL Type of sensor Flat surfaced semiconductor type Response time < 0s Resume time < 50s Working Voltage 9.0 ±.0V Working Current < 80mA Output To be external connection with 4, buttons, buzzer, DC relay and electromagnetic valve Accuracy ±5%LEL Expected Lifespan > year Standard Working Conditions Temperature:0 ~ 55 Humidity:0% ~ 90%RH Storage Conditions Temperature:-0 ~ 70 Humidity:0% ~ 90%RH Dimension: 6.9 4. 4.mm(L W H). Application field: Household gas leak alarm, gas leak controller.

D DC9 V RELAY-SPDT D5 4 00 7 4 4 5 K C SW 5V 报警灯 故障灯 延时灯 4 GND 5 6 预热按键 7 8 OUT(+5V ) _ BJ _ GZ _ YR GND NC KEY_YR AD/ 6 5 电磁阀 + 4 电磁阀 继电器 测试按键 电源灯 0 蜂鸣器 蜂鸣器 9 SW 5 D6 4 00 7 J4 NO COM NC CON MK VIN(DC 0 V) DCF+ DCF_CON DELAY_ CON KEY_TS _ DY SP- SP+ J5 DCF+ DCF- CON 4 MK-4&MCU BUZZER Q C 50 0 C 00 0 UF/ 6V GND GND B. Physical dimension ZP04 recommended diagram of application principle A 4 ZP04 Pins

ZP04 External dimension 4. Functional description of pin: Caution:When VCC=5V, the minimum of high level is 4.V (0mA Source Current), and the maximum of low level is 0.7V (0mA Sink Current). Pin No. Function Functional description Pin DC5V +5V output Pin Alarm lamp drive To output high level when alarming Pin Fault lamp drive To output low level when it has fault Pin4 Warm-up lamp drive To output low level during the warm-up course Pin5 GND Direct current supply Pin6 NC Hang in the air

Pin7 Keystroke To cancel warm-up by knobbing down this button during the warm-up course Pin8 NC Hang in the air Pin9 Buzzer drive Piezoelectric buzzer (three-terminal)oscillator output Pin0 Buzzer drive Piezoelectric buzzer (three-terminal)oscillator output Pin Electric Power lamp drive To output low level during normal operating period Pin Pin Pin4 Keystroke Relay drive Electromagnetic valve drive To detect basic function by knobbing down this button during normal operating period To output low level and connect with relay directly when giving alarm To output high level when giving alarm(specific refer to application circuit) To charge electromagnetic valve in voltage Electromagnetic valve Pin5 regulation and capacity during normal operating drive period Pin6 VCC Modular power input +9V 5. Installation instruction: This module connects with external part by adopting PH.0 configuration of single-row inserting pin. When using it, you just need insert the module into pre-set circuit. If the joint strength of the module need to be enhanced, you can weld the module on the circuit board directly. 6. Calibration: Required equipment : DCV-adjustable electric power, air box with vent fan, injector, sample gas bag, ZP04-calibrated fixture. A. Calibration method of alarm point : install the module on ZP04-calibrated fixture and being aged by switching on electric power for minutes. Through inject into the definite concentration of gas and adjust the comparative-point potentiometer, ZP04 will be on the state of alarm, and this point is comparative-point alarm. B. Calibration method of alarm point : According to the particularity of sensor, you can work out the value of alarm point. When ZP04 is welding, the potentiometer will be substituted by the fixed resistance, and this point is comparative-point alarm. C. Inspection of alarm point: Open the box of calibration, then make module connect up electric power again till warm-up of module is over. Now make a good seal of the air box, and then inject gas into the air box slowly to inspect whether the alarm point of module is satisfied to requirements. If not, please repeat the above steps.

7. Precautions: A. The module should be calibrated in the environment of undisturbed gas. B. Do not make the module contact with high concentration gas for long time, or the sensitivity will decline rapidly. C. Although the module has a good capability of anti-seismic, it should not be shocked excessively. 8. Diagram of application principle BOM Material label Material name Model and specification of No material Quantity MK Module ZP04Module D D Kenotron tube N4007 Light emitting Green diode Light emitting Yellow 4 diode 4 Light emitting Red 5 diode 6 K Dynatron DC9V 7 Q Buzzer C500 LS Feather-touch 9V piezoelectric buzzer 8 switch 9 SW SW Electrolytic capacitor 0 C Dynatron 000uF/6V Zhengzhou Winsen Electronics Technology Co., Ltd Add: No.99, Jinsuo Road, National Hi-Tech Zone, Zhengzhou 45000 China Tel: +86-7-6769097/6769670 Fax: +86-7-609988 E-mail: sales@winsensor.com Website: www.winsentech.com