AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Similar documents
XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters


FE1 Explosion-Proof Electric Air Heaters

Comfort. Description. Applications

FX5 Series Explosion-Proof Electric Air Heaters

Brasch Hazardous Location Unit Heaters

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

Ultra-Safe EXP Unit Heater

Description. Applications


EXH Series Explosionproof Electric Air Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters

Description. Applications

HLA Series Hazardous Location Fan Forced Unit Heater

CF1 ProVector Explosion-Proof Heaters

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

CX1 ProVector Explosion-Proof Heaters

HLA Series Hazardous Location Fan Forced Unit Heater

Owner s Manual. Electric Forced Air Heaters for Hazardous Locations. This manual covers the installation, maintenance, repair and replacement parts.

FE2 Series. Installation, Operation, & Maintenance Instructions. Electric Forced Air Heaters for Hazardous Locations. Model Coding

Description. Construction

KUH. Horizontal Unit Heater. Applications. Description

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

Explosion-proof Immersion Heater Type D-8660

Hazardous Area Portable Fan Heater The Bulldog

Industrial Air Heaters

FX5 SD Series Electric Forced Air Heaters for Hazardous Locations

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Thermal Devices, Inc. Mount Airy, Maryland USA

LUH HORIZONTAL FAN-FORCED UNIT HEATER

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Circulation Heaters Selection Guidelines

Explosion-Proof Forced Air Unit Heater - XGB

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Explosion-Proof Forced Air Unit Heater - XGB

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Call us today! (800)

Circulation Heaters Selection Guidelines

Hazardous Area Portable Fan Heater The Bulldog

Call us today! (800)

SUBMITTAL SCHEDULE & DATA

RGE 13 A T - 1 A

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Call us today! (800)

CXH-A Forced-Air Heater

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

How Limit Switches Can Stop Machines from Going Boom

Type UB-2502A and UB-3002A Forced-Air Heater

MacroAir AirSpan HVLS Fans

INSTRUCTION MANUAL (ATEX / IECEx)

Hazardous Area Portable Fan Heater The Bulldog

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

13 GEP A L P - 1 A

Dräger Polytron 5100 EC Detection of toxic gases and vapors

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

LTFX Electric Tank Immersion Heaters Installation Instructions

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Electric Unit Heaters

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Operating Instructions

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

MacroAir AirElite HVLS Fans

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

MACH N-407 Heat Pump Air-Cooled Chiller

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

TECHNICAL SPECIFICATIONS

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MacroAir AirVolution HVLS Fans

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Installation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls)

Center Mount Unit Coolers

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Why settle for anything less?

Fan Heaters Type VLEx

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

MAC N-407 Air-Cooled Chiller

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

ULTRA-SAFE Explosion-proof Duct Heaters

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals:

Transcription:

AEU1 Explosion-Proof Electric Air Heater For Hazardous Locations 0518 II 2G, Ex d IIB T4 Gb IP55 (ATEX) Ex d IIB T4 Gb IP55 (IECEx) 1ExdIIBT4 X IP55 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 1 & 2) or 0518 II 2D, Ex tb IIIB T135 C Db IP65 (ATEX) Ex tb IIIB T135 C Db IP65 (IECEx) Ex tb IIIB T135 C Db X IP65 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 21 & 22)

is a manufacturer of industrial-grade unit heaters suitable for hazardous and severe-duty locations. The AEU1 series of explosion-proof electric air heaters is designed to meet the most demanding requirements of heavy industry. The harsh operating conditions of this industry require heating equipment that is safe, reliable, dependable, and available when you need it. AEU1 unit heaters are designed to provide primary or supplementary heating for comfort or freeze protection in areas that are classified as hazardous locations (Gas or Dust atmospheres). Designed for hazardous locations! All Hazloc Heaters AEU1 models are CE Marked and certified for hazardous locations to meet ATEX and IECEx requirements. They have also received the Eurasian Conformity (EAC Ex) Mark certifying them for hazardous locations to the new Customs Union Technical Regulations. The three sizes of AEU1 heaters include our ExCaliber high performance liquid-to-air heat-exchanger cores that are available in fourteen 400 Volt, 50 Hz model choices to meet your specific heat output requirements at supply voltages between 380 V to 440 V and fourteen 480 Volt, 60 Hz models to accommodate shipping vessels, offshore rigs or other applications requiring 60 Hz. The rugged and versatile AEU1 heater incorporates a high quality immersion heater, high performance fan and motor assembly, a sturdy 2 mm (14 GA) steel cabinet with epoxy/polyester powder coating for corrosion resistance, large control enclosure with an extra port for convenient wiring of an external room thermostat, and enclosure O-rings to minimize moisture ingress. Standard safety features include two temperature high limits and a pressure relief device. AEU1 heaters are suitable for a wide variety of applications that include but are not limited to oil & gas drilling rigs, petrochemical facilities, refineries, chemical storage and handling facilities, paint storage areas, sewage treatment plants, aircraft servicing areas, grain elevators, or areas containing carbonaceous dusts. Rugged design, but easily maintained! All AEU1 heaters are designed for industrial applications with all features being heavyduty to meet your most demanding environments and long-life expectations. Even with heavy-gauge steel construction used throughout the heater it does not inhibit maintenance of the product since the AEU1 has been designed for easy field servicing with a removable heat exchanger core assembly, split fan guard, and replaceable automatic and manual reset high-limits. An added benefit is our 36-month heater warranty! Maximum durability rugged fin tubes! All AEU1 ExCaliber liquid-to-air heat-exchanger cores are evacuated & sealed and are constructed using rugged carbon-steel tubes with rollformed aluminum fins to maximize heat transfer and carbon-steel headers for maximum durability, resistance to corrosion, and longer life in your demanding applications. 2

Dedicated to Performance and Reliability! Aluminum louvers attached to dimpled cabinet panels for easy control of air flow direction 24 V controls with fuse protection (spare fuse included) O-rings on control & element enclosure lids to minimize moisture ingress Four mounting holes in top panel for dynamic load mounting High-quality pressure relief device prevents premature venting Stiffened top panel improves mounting strength 1" NPT, main electrical entry shipped with M25 adapter Additional 3/4" NPT external thermostat entry shipped with certified blanking plug Roll formed fin tubes for longer life & better performance Aluminum fan blade with easy-off replacement feature Flameproof (Ex d) and dust protected (Ex tb) control box with large opening for easy access to controls Steel braided flexible control cable and cable glands for secure connections Epoxy/Polyester coated 2 mm steel cabinet construction for durability Flameproof (Ex d) or dust protected (Ex tb) 1500 RPM, 71 frame Robust threepiece motor mount design prevents premature cracking Epoxy coated split fan guard for easy access to fan blade Automatic and manual high limits in element enclosure housing for added protection Accessories Mounting Brackets WMB Wall Mounting Bracket For use in buildings that have substantial walls. The Z sections provide additional support where necessary. BMB Basic Mounting Bracket For applications where the support arm can be bolted or welded directly to structural steel or concrete. PMB Pipe Mounting Bracket For buildings with insufficient strength to use other types of mounting brackets. Requires 3 in. pipe (3.5 in. O.D., min. Sch. 40, not supplied). HMB Hanging Mounting Bracket Ideal and economical if adequate overhead structure exists. Requires 1/2 in. pipe, cut and threaded (min. Sch. 40 not supplied). Note: When ordering mounting brackets, please specify the type of bracket preferred and the basic model code of the heater to be mounted. Example, PMB-AEU1-16. Mounting kits are made of steel with a black enamel paint finish. Structural support of heater and bracket during transit is required. 3

AEU1 Model Coding Factory Assigned Model Code Sequence Required for Ordering AEU 1 - G - 12-100 - 400 3 50 - B - N - A Model Series Product Revision No. For minor revisions Generation Factory Options For major revisions Flammable Substance Gas Dust (5 mm max) Fan Size 12 in. (305 mm) 16 in. (406 mm) 20 in. (508 mm) Consult factory G D Control Voltage 12 16 20 050 075 100 150 200 250 300 T B @ 400 volts only @ 480 volts only Power Output 5 kw 7.5 kw 10 kw 15 kw 20 kw 25 kw 30 kw No integral thermostat Integral thermostat N 12 in. (305 mm) fan size 12 in. (305 mm) fan size 12 in. (305 mm) fan size 16 in. (406 mm) fan size 16 in. (406 mm) fan size 20 in. (508 mm) fan size 20 in. (508 mm) fan size * PD[ Frequency 50 hertz 60 hertz Phase¹ 3 phase Heater Line Voltage @ 50 hertz only @ 60 hertz only 400 480 400 volts² 480 volts³ ¹S ingle (1) phase, 230 Volt, 50 Hz configuration is available by special order only. Please contact factory for ordering details. $ ²L ine Voltage is 400 Volt +/- 10%. For countries utilizing line voltages of 380 Volt to 440 Volt, refer to Page 7 for heater performance data. Do not exceed 440 Volt power supply. ³L ine Voltage is 480 Volt +/- 10%. [ PRXQWLQJ KROHV % 137 0DLQ HOHFWULFDO HQWU\ VKLSSHG ZLWK 0 DGDSWHU 50 60 3 AEU1 Physical Dimensions 24 volt A.C. 12 16 20 Heater Size (5-10kW) (15-20kW) (25-30kW) Dim. mm (inches) mm (inches) mm (inches) A 191 (7.5) 191 (7.5) 191 (7.5) B 462 (18.2) 566 (22.3) 667 (26.3) C 414 (16.3) 515 (20.3) 617 (24.3) D 482 (19.0) 583 (23.0) 686 (27.0) E 494 (19.5) 596 (23.5) 697 (27.4) F 79 (3.1) 130 (5.1) 181 (7.1) G 535 (21.1) 535 (21.1) 535 (21.1) 137 ([WHUQDO WKHUPRVWDW HQWU\ VKLSSHG ZLWK FHUWLILHG EODQNLQJ SOXJ /RXYHUV > @ PD[ ( & ) ' 4

AEU1 Specifications for all 50 Hz Models by Size Model AEU1-12 AEU1-16 AEU1-20 Fan diameter in (mm) 12 (305) 16 (406) 20 (508) Nominal kw 5 7.5 10 15 20 25 30 Air delivery m³/hr 680 1019 1359 2039 2888 3568 5097 Approximate air velocity m/s 2.4 3.6 4.9 4.1 5.8 4.6 6.6 Approximate horizontal air throw m 4.6 6.7 9.1 10.1 14.0 12.5 18.6 Motor power kw (hp) 0.37 (½) Maximum mounting height (to underside of heater) m 2.1 2.3 2.9 3.0 3.4 3.6 4.6 Approximate net weight kg (lbs) 65.4 (144) 67.2 (148) 79.8 (176) 91.5 (201) Approximate shipping weight kg (lbs) 92.2 (203) 94.0 (207) 108.4 (239) 122.8 (270) Wood crate dimensions Wood packaging material is in compliance with ISPM No. 15. W x D x H in mm 31.5 x 29.5 x 29.25 800 x 749 x 743 AEU1 Specifications for all 60 Hz Models by Size 35.5 x 29.5 x 31.75 902 x 749 x 806 39.5 x 29.5 x 35.75 1003 x 749 x 908 Model AEU1-12 AEU1-16 AEU1-20 Fan diameter in (mm) 12 (305) 16 (406) 20 (508) Nominal kw 5 7.5 10 15 20 25 30 Air delivery m³/hr 815 1225 1630 2445 3465 4280 6115 Approx. air velocity m/s 2.9 4.3 5.9 4.9 7.0 5.5 7.9 Approx. horizontal air throw m 5.5 8.0 11.0 12.1 16.8 15.0 22.3 Motor power kw (hp) 0.37 (½) Max. mounting height (to underside of heater) m 2.1 2.3 2.9 3.0 3.4 3.6 4.6 Approx. net weight kg (lbs) 65.4 (144) 67.2 (148) 79.8 (176) 91.5 (201) Approx. shipping weight kg (lbs) 92.2 (203) 94.0 (207) 108.4 (239) 122.8 (270) Wood crate dimensions Wood packaging material is in compliance with ISPM No. 15. W x D x H in mm 31.5 x 29.5 x 29.25 800 x 749 x 743 35.5 x 29.5 x 31.75 902 x 749 x 806 39.5 x 29.5 x 35.75 1003 x 749 x 908 How to Order When ordering refer to Page 7 to determine the specific model and then please follow the Model Code Sequence Required for Ordering format on Page 4. Example Model Code: AEU1-G-12-100-400350-B-N Important: Heater is to be used only in atmospheres that are compliant with the hazardous area atmosphere certification of the heater. Please ensure equipment is suitable for your application. The maximum allowable dust layer thickness for dust protected, Ex tb heaters is 5mm. Based on the environment the heater is installed in ensure the maintenance program is designed to meet this criteria. Do not operate heater in atmospheres which are corrosive to aluminum or steel. 5

AEU1 General Specifications ATEX (Gas atmospheres) SIRA 13 ATEX 1240X 0518 II 2G Ex d IIB T4 Gb IP55 (Suitable for Zone 1 and 2) ATEX (Dust atmospheres) 5 mm maximum SIRA 13 ATEX 1240X 0518 II 2D Ex tb IIIB T135 C Db IP65 (Suitable for Zone 21 and 22) Hazardous Location Approvals IECEx (Gas atmospheres) IECEx (Dust atmospheres) 5 mm maximum IECEX CSA 13.0034X Ex d IIB T4 Gb IP55 IECEX CSA 13.0034X Ex tb IIIB T135 C Db IP65 (Suitable for Zone 1 and 2) (Suitable for Zone 21 and 22) EAC Ex (Gas atmospheres) RU C-CA. GB06.B.00282 1ExdIIBT4 X IP55 (Suitable for Zone 1 and 2) EAC Ex (Dust atmospheres) 5 mm maximum RU C-CA. GB06.B.00282 Ex tb IIIB T135 C Db X, IP65 (Suitable for Zone 21 and 22) Cabinet Motor/Fan Heat Exchanger Protection Controls Operating Limits Cabinet material Fan guard Louver blades Fasteners Enclosure Mounting holes Motor type Fan Heat transfer fluid ExCaliber Core Temperature high limits Pressure relief Control circuit Control contactor Control transformer Fuse protection Room thermostat Ambient temperature Maximum altitude 2 mm (14-gauge) steel. Yellow epoxy/polyester powder coated with five-stage pretreatment, including iron phosphate. Split design with close wire spacing. A 9.5 mm diameter probe will not enter. Black polyester powder coated. Anodized extruded aluminum. Zinc plated steel for corrosion resistance. Flame proof (Ex d) and dust protected (Ex tb) cast aluminum with O-ring. 14 mm diameter holes Four located on the top face of heater. Flameproof (Ex d) or dust protected (Ex tb), thermally protected, 1500 RPM (nominal) permanently lubricated ball bearing type with 71 frame and easy-off fan blade replacement feature. Multi-blade non sparking aluminum, steel spider and hub with 14 mm bore. Ethylene glycol and water including corrosion inhibitors. Carbon steel shells and carbon steel tubes with copper-free, roll-formed aluminum fins @ 2.5mm pitch. Evacuated and sealed. Sprayed with black, high heat enamel paint. One automatic reset rated for 100,000 cycles, and one manual reset. Both are snap-action bimetal type, open on temperature rise. High-quality pressure relief device. Built in 24 V control. (1.04 amps, 25 VA, grounded) 40 FLA amp (50 A resistive per pole) Definite Purpose. Rated for 500,000 mechanical operations. 24 VAC output. Thermal delay fuse (with spare fuse included). A wall mount thermostat is available. Consult factory for integral thermostat details. -40 C to 40 C. Storage -40 C to 60 C. 3000 m above sea level. 6

AEU1 Heater 50 Hz Performance Data (Gas or Dust atmospheres) kw Line Volts Ø Fan Dia. in. Model See page 4 to complete model coding Total Amps A Air Temp. Rise 7.9* 19.1* 4.5* 380* 5 400 8.2 21.2 3 12 AEU1-?-12-050-400350-B- 5.4* 415* # 8.5* 22.8* 6.1* 440* max 8.9* 25.7* 6.8* 380* 11.3* 20.2* 7.5 400 11.8 22.4 3 12 AEU1-?-12-075-400350-B- 8.1* 415* # 12.2* 24.1* 9.1* 440* max 12.9* 27.1* 9.0* 380* 14.7* 19.5* 10 400 15.4 21.6 3 12 AEU1-?-12-100-400350-B- 10.8* 415* # 16.0* 23.3* 12.1* 440* max 16.9* 26.1* 13.5* 380* 21.6* 19.6* 15 400 22.7 21.7 3 16 AEU1-?-16-150-400350-B- 16.1* 415* # 23.5* 23.4* 18.2* 440* max 24.8* 26.3* 18.1* 380* 28.4* 18.7* 20 400 29.9 20.7 3 16 AEU1-?-16-200-400350-B- 21.5* 415* # 31.0* 22.3* 24.2* 440* max 32.8* 25.0* 22.6* 380* 35.3* 18.8* 25 400 37.1 20.8 3 20 AEU1-?-20-250-400350-B- 26.9* 415* # 38.4* 22.4* 30.3* 440* max 40.7* 25.2* 27.1* 380* 42.1* 15.8* 30 400 44.3 17.5 3 20 AEU1-?-20-300-400350-B- 32.3* 415* # 45.9* 18.8* 36.3* 440* max 48.6* 21.2* C AEU1 Heater 60 Hz Performance Data (Gas or Dust atmospheres) kw Line Volts Ø Fan Dia. in. Model See page 4 to complete model coding Total Amps A Air Temp. Rise 5 480 3 12 AEU1-?-12-050-480360-B- # 6.7 17.7 7.5 480 3 12 AEU1-?-12-075-480360-B- # 9.7 18.7 10 480 3 12 AEU1-?-12-100-480360-B- # 12.7 18.0 15 480 3 16 AEU1-?-16-150-480360-B- # 18.7 18.1 20 480 3 16 AEU1-?-16-200-480360-B- # 24.8 17.3 25 480 3 20 AEU1-?-20-250-480360-B- # 31.1 17.4 30 480 3 20 AEU1-?-20-300-480360-B- # 37.1 14.6 ( ) Actual output figures are prorated based on 400 Volt wye connected heating elements. * Do not exceed 440 Volt supply power. (?) Refer to Page 4 for Flammable Substance selection of Gas or Dust. (#) Refer to Page 4 for Factory Option codes to complete entire model code for ordering. ( ) Line Voltage is 480 Volt +/- 10%. Output figures will be prorated. Do not exceed 528 Volt supply power. C 7

Packaging Certification Hazloc Heaters has been certified under the Canadian Wood Packaging Certification Program (CWPCP) for export and production of wood packaging that meets the International Standard for Phytosanitary Measures No. 15 (ISPM No. 15). Facility Registration Number CA-01420. Quality Mission Statement Quality is customers that come back, and products that don t. Limited 36-Month Warranty Hazloc Heaters warrants all AEU1 series of explosion-proof electric heaters against defects in materials and workmanship under normal conditions of use for a period of thirty-six (36) months from date of purchase based on the following terms: 1. The heater must not be modified in any way. 2. The heater must be stored, installed and used only in accordance with the owner s manual and attached data plate information. 3. Replacement parts will be provided free of charge as necessary to restore any unit to normal operating condition, provided that the defective parts be returned to us freight prepaid and that the replacement parts be accepted freight collect. 4. The complete heater may be returned to our manufacturing plant for repair or replacement (at our discretion), freight charges prepaid. 5. Contamination by dirt, dust, etc. or corrosion will not be considered as defects. 6. This warranty shall be limited to the actual equipment involved and, under no circumstances, shall include or extend to installation or removal costs, or to consequential damages or losses. Available from: Hazloc Heaters is a trademark of Hazloc Heaters Inc. The information contained in this brochure has been carefully checked and verified for accuracy. Specifications subject to change without notice. PRINTED IN CANADA Copyright 2014 Cat No. AEU1-201401-1.0-A4