WATER BATH BM100 BM200

Similar documents
ROTARY EVAPORATOR RE400

ROTARY EVAPORATOR RE550

ROTARY EVAPORATOR RE210 RE510

Organic Solvent Recovery Unit RT200. Instruction Manual. - First Edition -

Demineralizers. Still, water, models WG221 WG221S. First Edition. Thank you very much for buying Yamato Scientific AUTO STILL series WG221/221S model.

Shaker. SA300 (2-way Shaking Method) SA320 (Rotary Shaking Method) Instruction Manual. - First Edition -

Instruction Manual For Vacuum Drying Oven. Model ADP21 ADP31

Plasma Treatment System PiPi. Instruction Manual

Low Temperature Incubator IJ 100. Instruction Manual. - First Edition -

BK300/400/500/610/710

Rotary Evaporator RE300/600/800. Instruction Manual. - Second Edition -

OPERATION MANUAL AUTOCLAVE HICLAVE HGD-113, HGD-133. Read this manual carefully and follow the instructions to use the equipment correctly.

HG-113 & 133 OPERATION MANUAL

Water Purifier, Auto Still WS 200/220. Instruction Manual. - First Edition -

Cold Trap CA301. Instruction Manual. First Edition. Thank you very much for purchasing this Yamato Cold Trap CA301.

Operation Manual for Incubator

HG-50/HG-80 OPERATING MANUAL WARNING. Be sure to read this operation manual carefully and handle it properly. (Form: CE-014a-01)

FORCED CONVECTION OVEN MODEL DRM620DD OPERATION MANUAL HIRO COMPANY

HG-50/HG-80 OPERATING MANUAL WARNING. Be sure to read this operation manual carefully and handle it properly. (Form: CE-014a-01)

HIRAYAMA AUTOCLAVE HICLAVE HVA-85 HVA-110

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Explosion-proof Duct Heaters

Low Constant Temperature Water Bath BV100/200/300. Instruction Manual. - First Edition -

Electron Microscopy Sciences

INSTRUCTION MANUAL FOR

Fire Prevention, Life & Safety Program

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Operating manual ELECTRIC ASPIRATOR 00) : 1) Page 1

FACT SHEET Program: Lab Fire Safety

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

INSTRUCTION MANUAL EPH-121 CONTENTS

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Hazardous area descriptions

Model:DKG610(V)/650(V) Model:DKG810(V)/850(V)

PARAFFIN/DIESEL HEATER

Chemistry 11 Laboratory Safety Guidelines

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

99 Washington Street Melrose, MA Phone Toll Free Visit us at

TAIJI HOTCABI Towel Warmer

SBS-H2 Hydrogen Gas Detector Kit

DIESEL/PARAFFIN HEATERS

Forced Convection Constant Temperature Oven. Instruction Manual

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

ESD500. ESD500 Combustible / Toxic Gas Detector

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

Smokeless Roaster Operational Manual

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0)

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

1. GENERAL TECHNICAL INFORMATION

Inverter Split-type Room Air Conditioner

Digital Heat Block User Manual

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

Working safely with flammable liquids

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

PWASH Gallon Parts Washer Assembly & Operating Instructions

ESD3000 ESD200 Combustible / Toxic Gas Detector

Green Chemistry Safety Training PSE/CH 335. Departments of Forest Biomaterials and Chemistry North Carolina State University

WATER BATH MODEL TBS451PA OPERATION MANUAL

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

PORTABLE DEHUMIDIFIER

INFRARED ZONE HEATING SYSTEM

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Fire Alarm System Accessories

INFRARED ZONE HEATING SYSTEM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

ESD3000IR ESD3000IR. Infrared Gas Detector

Humidity and Thermostat control box for Attic Fan

Water Bath BM500/510. Oil Bath BO400/410

Fire Alarm System Accessories

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Combustible Gas Leak Detector Instruction Manual

Safety instructions and routines on lab Faculty of Odontology Malmö University

Installation and Wiring 1.

AUC Cell Washer. User Manual

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Air Paper Jogger AJ-700 Operation Manual. Keep this manual at hand where it can be referenced at any time.

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

GDDEM10 DEHUMIDIFIER

Electron Microscopy Sciences

FIRE SAFETY. Department of Chemical Engineering College of Engineering

Implementation of ATEX Guidelines

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

Coway Air Purifier AP-1008DH

infrared paraffin / kerosene / diesel heater

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

Residential Gas Hybrid Water Heater

ST E /ST E / ST E / ST E ST E / ST E / ST E

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

Low mg/m

VSD AND SS DRIVING ATEX MOTORS February 2014

ROX-10WB-E WATER ELECTROLYZER INSTRUCTION MANUAL FOR END USER L188AU111 (100507)

Combustible Gas Leak Detector Instruction Manual

PLEASE READ AND SAVE THESE INSTRUCTIONS

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Operation Manual. (Version 1.5.1)

Transcription:

No.AC5-9708-12-BM WATER BATH BM100 BM200 First Edition Thank you for your Yamato Scientific BM series Water Bath purchase. For proper use of this unit, please read the instruction manual and warranty thoroughly before operation. Keep both for any future references. Read and apprehend important warnings in this instruction manual prior to use. Yamato Scientific America Inc. Santa Clara, CA

Table of Contents 1. Specifications...1 2. Safety Information... 2-5 Safety Symbols..2 Safety Precautions.3-4 Hazardous Materials.5 3. Identification of Parts... 6-9 BM100.6 BM200.7 Sample : Combined with RE200.8 Sample : Combined with RE500.9 4. How to Operate...10 5. Maintenance...11 Daily maintenance/weekly maintenance..11 Troubleshooting Guide.. 11 6. After Sale Service and Warranty...12 Request for Repair..12 7. Replacement Parts...13 8. Wiring Diagram...14

1. Specifications Model BM100 BM200 Temp. range during operation Room temp. +5 ~ 95 *1 Temp. setting range 0 ~ 100 Accuracy of temp. adjustment ±2 at 60 Control system ON/OFF control Set-up system Analog set-up Display system Thermometer Operation function Operation at fixed point Thermoregulator Liquid-operated thermoregulator Material SUS316 pipe heater Heater Capacity 500W 1kW Power switch Paddle switch Power lamp Lit when power is on - Drain (with plug) Others - Service outlet for RE Safety device Protection from overcurrent (fuse) Capacity 4 ml 7 ml Tank Dimension Φ7.9 Depth 4.7 (inches) Φ9.4 Depth 5.9 (inches) Φ20 Depth 12 (cm) Φ24 Depth 15 (cm) External dimensions (W D H) 9.4 11.8 5.9 (inches) 12.2 14.2 9.1 (inches) 24 30 15 (cm) 31 36 23 (cm) Weight 7.7lb (3.5kg) 13.3lb (6kg) Required power source AC115V±10% 50/60Hz 4.5A AC115V±10% 50/60Hz 9A Liquid used Water Bar Alcohol Thermometer (-10 ~110 with immersion line) 1 Standard accessories Fuse 1 Instruction manual 1 Guarantee 1 1

2. Safety Information Safety Symbols Safety Information This instruction manual and our products apply various indications for safety. Ignoring these indications can cause such situations as listed below. Read and understand the following warning and caution signs in this manual prior to use. WARNING Indicates the possibility of serious or fatal injury (Note 1). CAUTION Indicates the possibility of injury (Note 2) or damage (Note 3) to the equipment. (Note 1) Serious injury : Bodily harm by electric shock, bone fracture or poisoning which may require hospitalization. (Note 2) Injury : Bodily harm by electric shock, bone fracture or poisoning which may not require hospitalization. (Note 3) Damage : Any damage on equipment, facility, structure, etc. Meaning of Graphic Indications Shows warning or caution. Specific contents are described aside each sign. Shows users important information not to do. Specific contents are described aside each sign. Shows users important information sure to do. Specific contents are described aside each sign. 2

Safety Information Safety Precautions Do not use this unit for any purpose other than its intended use, described in this manual. Do not use this unit in flammable or explosive gas environments. This unit is not explosion proof. Never use this unit in flammable or explosive gas environments. Never fail to ground the unit. This unit uses a 3-conductor power cord (including ground wire). Be sure to ground the unit for safety. Do not use this unit if a malfunction occurs. If smoke or any strange odor should disburse from this unit, turn the power off immediately and pull out the main power cord. Then contact Yamato Scientific. Neglecting this procedure can result in fire or electric shock. Never try repairing the unit yourself. Do not bundle the power cord. Overheat or fire can occur if the power cord is bundled or if an object is on the cord. Do not damage the power cord. Forcible bending, pulling wrenching or extending the power cord can cause fire or electric shock. Do not use any explosive or flammable heat medium. Never use any explosive or flammable substances or such compounds as a heat medium which could cause an explosion or fire. Avoid water contact. To avoid electric leak or shock, avoid direct contact with water. Do not heat with low water. If you operate this unit with low water, fire can be caused by overheating. Do not disassemble or remodel the unit To avoid fire or electric shock, never try disassemble this unit. 3

Safety Information Safety Precautions If it begins to thunder In the event of electrical storm turn off the main power. Neglecting this procedure can result in fire, electric shock or other troubles due to thunderbolts. In case of power failure When the power is restored after a power failure, the unit resumes operation at the temperature previously set as if you turned off the unit. Indication of temperature and operational range. This unit is not equipped with a stirring function. Therefore, the maximum temperature varies according to the environments or operational conditions. This unit does not necessarily reach the maximum operational temperature under such environments as low room temperature. 4

Safety Information Hazardous Materials Hazardous material are listed below. Never use these materials as samples or heat media. Nitroglycol, Nitroglycerin, Nitrocellulose, and other explosive nitric esters. Explosive Explosive Substance Combustible Substance Oxidant Trinitrobenzene, Trinitrotoluene, Picric acid, and other explosive nitro compounds. Peracetic acid, Methyl ethyl ketone peroxide, Benzoyl peroxide, and other organic peroxides. Sodium azide, and other metallic azides Metallic lithium, Metallic potassium, Metallic sodium, Yellow phosphorus, Phosphorus sulfide, Red phosphorus, Celluloid, Calcium carbide, Lime phosphate, Magnesium powder, Aluminum powder, and other combustible metal powders and sodium dithionite (hydrosulfite). Potassium chlorate, Sodium chlorate, Ammonium chlorate, and other chlorates. Potassium perchlorate, Sodium perchlorate, Ammonia perchlorate, and other perchlorates. Potassium peroxide, Sodium peroxide, Barium peroxide, and other inorganic peroxides. Potassium nitrate, Sodium nitrate, Ammonia nitrate, and other nitrates. Flammable Sodium chlorite and other chlorites. Calcium hypochlorite and other hypochlorites. Ignitable Substance Combustible Gas Ethyl ether, Gasoline, Acetaldehyde, Propylene Oxide, Carbon disulfide, and other flammable substances with a flash point below minus 30ºC. Normal hexane, Ethylene oxide, Acetone, Benzene, Methyl ethyl ketone, and other flammable substances with a flash point between minus 30ºC and 0 o C. Methanol, Ethanol, Xylene, Pentyl acetate (amyl acetate), and other flammable substance with a flash point between 0ºC and 30ºC. Kerosene, Light oil, Turpentine oil, Isoamyl alcohol, Acetic acid, and other flammable substances with a flash point between 30ºC and 65ºC Hydrogen, Acetylene, Ethylene, Methane, Ethane, Propane, Butane and other flammable gas at 15 degree and under 1 atmosphere. 5

3. Identification of Parts BM100 BM100 Thermometer Power Switch Power Lamp Temperature Dial Fuse Power Cable Sensor Thermometer Holder Heater 6

Identification of Parts BM200 BM200 Thermometer Power Switch Drain Plug Power Lamp Temperature Dial Service Outlet Fuse Power Cable Heater Thermometer Holder Sensor 7

Identification of Parts Sample : Combined with RE200 Combination with RE200 Drawing 1 Drawing 2 According to the position or space to set the bath and the body, the arm jack can be set in the front (drawing 1)or on the right side (drawing 2) as shown above. 8

Identification of Parts Sample : Combined with RE500 Combination with RE500 9

4. How to Operate How to operate Power Lamp Temperature Dial 1. Pour adequate water (3000ml for BM100, 5000ml for BM200) into the tank, and place a thermometer in the holder. Use distilled water. Deionized water should not be used. 2. Connect the unit securely to a power source with AC115V. Always use a grounded outlet. Set the temperature dial to the desired temperature and turn on the power switch. The power lamp is lit when the power heater is on. 3. The temperature scale shows an approximate figure. When the temperature rises close to the set point, read the thermometer to adjust the temperature. Since there are some differences from the set point the first time, check if the current temperature accords with the degree to operate. This unit does not have a stirring function and the tank temperature varies. We recommend you to use any stirrer (our Lab. Stirrer etc.,) together with this unit. Power Failure When power supply is restored after a power failure, the unit re-starts operation from previously set temperature. 10

5. Maintenance Daily maintenance/weekly maintenance Do not disjoint the unit Never modify the unit. There are some high-voltage areas inside the unit, which could cause electric shock. Request Yamato Scientific for internal check, adjustment or repair. Maintenance Daily Maintenance: Turn power switch off and disconnect main power cord before attempting any maintenance. Once the water bath has cooled to room temperature you may empty the water. Wipe off any excess dirt on the interior and exterior with a damp cloth. Do not use benzene, thinner or cleanser. Weekly Maintenance: The pipe heater should be cleaned at least twice a month. Accumulation of scale build up results in poor heat transfer and high sheath temperatures. When the unit is not in use for a long period of time. Be sure to disconnect main power and drain the water tank if the unit will not be used for a long period of time. Troubleshooting Guide Situation The power lamp on the panel is not lit when the power switch is on. Make Sure Check main power cord is connected firmly. Check main input voltage. If you have any question, contact Yamato Scientific. 11

6. After Sale Service and Warranty Request for Repair When you request repair If any troubles should occur, stop the operation immediately, turn the power off, pull the power cord out and contact Yamato Scientific s Technical Service Department. Necessary information Model Number Serial Number Date of Purchase Distributor Name Information on difficulties To reach Yamato s Technical Service Department, please call (800) 292-6286 Ext. 235 Warranty Keep your warranty card for future references. Check the name of the distributor, date of purchase and any other contents of warranty. The terms of warranty is two years limited commencing the date of purchase. Repair is made without charge according to the contents of warranty. Decontamination Statement: We can not accept any products or parts returned to us for repair or credit that is contaminated with or has been exposed to potentially infectious agents or radioactive materials. If you need repair, please call Yamato Scientific at (800) 292-6286 Ext. 221 for a return authorization number. No product will be accepted without this number. 12

7. Replacement Parts Name of Parts Parts Number Specification Fuse 2100010013 F7161 Φ6.4 30 125V 7A (for BM100) Fuse 2100060001 MF61NR15 Φ6.35 31.8 250V 15A (for BM200) Thermometer 5020016016 (for BM100/200) Drain Plug 7320016005 (for BM200) O Ring 4210026020 P12.5 Baiton (for BM200) Thermal Fuse 2100030007 (for BM100/200) Heater Element BM10A-30260 (for BM100) Heater Element BM40A-30070 (for BM200) Power Lamp 2090060041 (for BM100/200) Thermoregulator 1030020005 (for BM100/200) 13

8. Wiring Diagram BM100 BM200 AC115V B W T 1 2 1 2 1 2 3 4 5 F 6 1 TCS 2 4 SC G 3 3 LN TF 4 4 7 H Symbol Name of Parts Symbol Name of Parts F Fuse S Service Outlet H Heater SW Power Switch TF Thermal Fuse TCS Thermoregulator LN Power Lamp T Terminal P Power Plug 14

Responsibility Please follow the instructions in this document when using this unit. Yamato Scientific has no responsibility for the accidents or breakdown of device if it is used with a failure to comply. Never conduct what this document forbids. Unexpected accidents or breakdown may result in. Note The contents of this document may be changed in future without notice. Any books with missing pages or disorderly binding may be replaced. Instruction Manual for WATER BATH Model BM100/200 First Edition Feb. 16, 2006 Yamato Scientific America, Inc. 925 Walsh Avenue, Santa Clara, CA 95050, U.S.A http://www.yamato-usa.com Toll Free: 1-800-2-YAMATO(1-800-292-286)