M15051) INSTRUCTION MANUAL

Similar documents
DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Operating Instructions. For. Alarm Control Module. Model SSR 500

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

02/11/2015

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

LC3000 Level Controller Installation and Maintenance Instructions

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Process Alarm Module RTA 421

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

I/O ZONE 560/583 AND OPERATION MANUAL

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

SACE PR021/K SIGNALLING UNIT

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

OPERATING INSTRUCTIONS COP-F (ANSI 81O/81U)

OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N)

02/11/2015

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TCM-2 Thyristor Control Module DATA SHEET

CMD420 / CMD421 Series

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

WIO200 Water In Oil measuring instrument

LC2200 Level Controller Installation and Maintenance Instructions

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

MO n : 12JMC rév A

Room thermostats with LCD for wall mounting

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

FCR 05, FCR 07. Power factor correction controller. User and service manual

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Monitoring Devices 11/1

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Constant voltage 3-phase rectifier.

Ordering Key. Dielectric strength

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

Process & TeMPerATUre UniversAl input DigiTAl MeTers

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

CTT8 TEMPERATURE MONITOR DEVICE

REC-8R Environmental Control. Operation and Installation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Single phase solid state contactors ENG. User Manual DATA MANAGEMENT CONTROLS PROCESS AUTOMATION

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

EUROFLAT SERIES TYPES C... S... M...

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

INSTALLATION AND OPERATING MANUAL OF THE BASIC CONTROL PANEL (CCB) FOR THE FISAIR EVAPORATIVE HUMIDIFIERS

RE-PR3-E-27 3-Phase Panel Mount 27kW

FEC400 Series. Installation Manual

QA(13) - Series Miniature Circuit Breakers

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

PAC1500Xi PORTABLE APPLIANCE CHECKER

Flush-mounted room thermostat

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Intelligent addressable fire alarm control panel

ADC150 Automatic Draft Control

SET-2000 Hi Level/Oil

Low Temperature Zirconia Oxygen Analyzer

DIGITAL LIGHT CONTROLLER

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

RELEASE DEVICE CONTROLS

PTE0705 Electric Fence Monitor

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

REA 105 Arc Protection Module. Operator s Manual

Wall-mounted room thermostat with LCD

Moulded case circuit brakers

Model 17A00 Expansion Enclosure

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

03.03.mmm REV.2 09/01

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

EARTH FAULT METER MD-08

Installation, Operating and Maintenance Manual

RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value)

BC-R10 Series. Burner Controllers

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

THERMOSTAT i-basic 3 USER MANUAL Rev.100

ISIS SAFETY SYSTEM Installation guide

SECTION AUTOMATIC TRANSFER SWITCHES

Tri-Stack Smart System

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

VAMP 120 & 121. Arc flash detection units. Product picture

Transcription:

INSULATION GUARD MEG-1000 (Code M15051) INSTRUCTION MANUAL ( M98122001-20 / 05A ) (c) CIRCUTOR S.A.

Insulation guard MEG-1000 1.- BASIC INSTRUCTIONS 1.1.- Delivery spot check This manual is issued to help all the MEG-1000 users to install and use it in order to get the best from it. After receiving the unit please check the following points: (a) Does this device corresponds to your order specifications? (b) Check if any damage was done during the shipment process. (c) Verify that it includes one instruction manual. 1.2.- Connection procedures For the safe use of MEG-1000 is basic that people who install or handle it follow the normal safety considerations and the diverse advises related in this manual. Before connecting verify: a. The power supply of the instrument (as default, 230 Va.c. ± 20 %) corresponds to the rated voltage of the mains where you have to power it. b. The voltage between phase and ground (points between which the insulating level will be measured) have to be in normal conditions lower or equal than 600 Va.c. c. Due to its operation mode, the device can only be used in A.C. networks. Page nº 1

2.- MAIN CHARACTERISTICS MEG-1000 is an electronic device that measures the insulating resistance between the ground and one phase of an insulated neutral network (IT). The insulating resistance value shows on a double scale galvanometer, which the equipment selects automatically depending on the value. Page nº 2

Two output relays with temporisation adjustment are available: high resistance relay (NORMAL) and low resistance relay (ALARM). The trip value and the delay can be adjusted on each relay. The adjustment is done by means of three rear push buttons (MODE,, ). All adjustments are memorised even if the equipment is not powered on. The equipment has five led in the front plate, that indicate the measuring scale and the output relays status in the operation mode; and the adjusted parameter in the set-up mode. Before operating the instrument read the INSTALLATION and ADJUST chapters and choose the properly operation mode. 3.- INSTALLATION AND START-UP The manual you hold in your hands contains information and warnings that the user should respect in order to guarantee a proper operation of all the instrument functions and keep its safety conditions. The instrument must not be powered on and used until its definitive assembly on the cabinet s door. If the instrument is not used as manufacturer s specifications, the protection of the instrument can be damaged. When any protection failure is suspected to exist (for example, it presents external visible damages), the instrument must be immediately powered off. In this case contact a qualified service representative. Page nº 3

3.1.- INSTALLATION Before applying AC power to the instrument, check the following points: a.- Auxiliary voltage supply: 230 Va.c. ± 20 % - Connection terminals: A1-A2. - Instrument consumption: 2.8 VA. b.- Measuring network structure: A.C. insulated or impedant neutral network (IT) with phase-ground voltage 600 Va.c. c.- Maximum permanent voltage between the measuring connection terminals (E-R): 1000 Va.c.* - Connection terminals: E-R. * This value allows the instrument to be protected from a phase fall on ground. d.- Operation conditions: - Working temperature: -20 to +50 ºC. - Protection degree: Front plate: IP 52 / Connection terminals: IP 20. - Indoor use. e.- Safety: Designed to meet protection class I as per EN 61010. Mounting: The instrument is to be mounted on a panel. All connections keep inside the cabinet. Page nº 4

Note that with the instrument powered on, the terminals could be dangerous to touching and cover opening actions or elements removal may allow accessing dangerous parts. Therefore, the instrument must not be used until this is completely installed. The instrument must be connected to a power supply circuit protected with gl type (IEC 269 ) or M type fuses rated between 0.5 and 2 A. This circuit should be provided with an automatic switch or any equivalent element to disconnect the instrument from the power supply network. The supply and measuring voltage circuits will be both connected through a wire with a minimum cross-section of 1 mm 2. 3.2.- MEG-1000 CONNECTION 3.2.1.- Connection terminals Name Concept A1 - A2 Auxiliary supply of the device (230 Va.c. ± 20 %) E R Measuring of the insulation between a phase (R) and earth (E) 15-18 - 16 NORMAL relay with switchover contacts (free of voltage). 15-18: NO contact. 15-16: NC contact. 25-28 - 26 ALARM relay with switchover contacts (free of voltage). 25-28: NO contact. 25-26: NC contact. Page nº 5

3.2.2- Wiring diagram Page nº 6

4.- OPERATION MODE The user is informed about all the parameters by means of: Double scale galvanometer, that shows the value of the insulating resistance (1). 5 front plate leds: - MΩ (2) and kω (3) leds indicate the measuring scale. - ALARM (4) and NORMAL (5) leds indicate if the resistance is lower or higher than the adjusted trip values. - ALARM (4), NORMAL (5) and TIME (6) leds indicate the adjusted parameter, when you are in adjusting mode. (3) (2) (4) (1) (5) (6) Page nº 7

The operation mode of the insulating guard is the following: 1. The device applies 24 Vd.c. voltage between the phase (R connection terminal) and the ground (E connection terminal) and measures the current. 2. The insulating resistance value, that is showed in the front plate galvanometer (1), is obtained from the voltage and current values. The instrument changes automatically the measuring scale, depending on the value of the resistance. (2) and (3) yellow leds indicate whether the value is referred to the MΩ scale or to the kω scale. 4.1.- OUTPUT RELAYS. OPERATION AND INDICATORS Two output relays are available: ALARM relay and NORMAL relay. The trip value and the delay time can be adjusted in each relay. NORMAL relay While the insulating resistance is higher than the adjusted trip value the NORMAL relay keeps de-activated. If the resistance being measured is lower than the adjusted trip value the relay is activated after a set time. Delay only takes place in relay activation; thus, when the resistance goes beyond the relay trip value the relay is instantaneously de-activated. NORMAL (5) green led lit on means that the insulating resistance is higher than the NORMAL trip value. Page nº 8

ALARM relay While the insulating resistance is lower than the adjusted trip value the ALARM relay keeps de-activated. If the resistance being measured is higher than the adjusted trip value the relay is activated after a set time. Delay only takes place in relay activation; thus, when the resistance lowers under the relay trip value the relay is instantaneously de-activated. ALARM (4) red led lit on means that the insulating resistance is lower than the ALARM trip value. In a chart: Page nº 9

4.2.- EQUIPMENT ADJUSTMENT The equipment has three rear push buttons in order to adjust the ALARM and NORMAL values and their corresponding temporisation: MODE push button MODE push button gives access to different adjustments and allows to pass from one adjustment to the other. Upward and downward push buttons These two buttons adjust the selected value through the indication needle on the scale. In the adjustment mode the equipment has a safety temporisation. After 10 seconds without pressing one of the push buttons, the equipment automatically goes back to working mode, only updating the values entered pressing MODE (see adjustment sequence in page 12). The pointer and the scale leds (kω (2) and MΩ (3)) show the trip value when it is being adjusted. Any value within the measuring range can be adjusted. For a properly operation of the instrument, the NORMAL relay trip value should be higher than the ALARM relay trip value. Page nº 10

The pointer and the scale leds (kω (2) and MΩ (3)) show the delay time when it is being adjusted: - ALARM relay temporisation. Each 100 kω means a trip delay of 1 second. The active measuring scale is the kω scale. The adjusting range is within 0.1 and 3 s. - NORMAL relay temporisation. If the active measuring scale is the kω scale, each 100 kω means a trip delay of 1 second. If the active measuring scale is MΩ, each 1 MΩ means a trip delay of 10 seconds. The adjusting range is within 0.1 and 30 s. Adjustment push buttons give access to different adjustments according to the following sequence: Page nº 11

OPERATION MODE Press MODE ADJUST OF THE ALARM RELAY TRIP VALUE ALARM led blinks. Adjust the value by means of and Press MODE ADJUST OF THE ALARM RELAY DELAY TIME ALARM and TIME leds blink. Adjust the value by means of and Press MODE ADJUST OF THE NORMAL RELAY TRIP VALUE NORMAL led blinks. Adjust the value by means of and Press MODE ADJUST OF THE NORMAL RELAY DELAY TIME NORMAL and TIME leds blink. Adjust the value by means of and Press MODE Quick adjustment mode Page nº 12

Besides of the explained adjusting mode, the instrument has a quick adjustment where the next default values are loaded: ALARM relay trip value... ALARM relay delay time... NORMAL relay trip value... NORMAL relay delay time... 440 kω 0.5 s 3 MΩ 3 s In order to load these values all three push buttons (MODE, and ) must be pressed at the same time for a minimum of 2 seconds; during that time all led blink simultaneously. When the leds are off the equipment returns to working mode. NOTICE: When pressing the three push buttons do not press MODE button first, otherwise the equipment will go to adjustment mode. 5.- TECHNICAL CHARACTERISTICS Auxiliary supply Voltage: 230 V ± 20% 50...60 Hz. Consumption: 2.8 VA. Measuring circuit Measuring range: within 0 and 500 kω, in kω measuring scale. within 0.5 and 5 MΩ, in MΩ measuring scale. Accuracy:1.5 class Maximum permanent voltage between E and R connection terminals: 1000 Va.c. Voltage applied by the equipment between E and R connection terminals in order to measure the insulating resistance: 24 Vd.c. Page nº 13

Output relays Relays: ALARM (15-16-18) and NORMAL (25-26-28). Type: mechanical, 3 terminals, free of voltage. Use: AC11 250 V/8 A Isolation between contacts: 1000 Va.c. between coil and contacts: 4000 Va.c. Relays temporisation adjustment ALARM relay: from 0.1 to 3 s. NORMAL relay: from 0.1 to 30 s. Accuracy: ± 10 %. Isolation Between any connection terminal and the case: 2.5 kv 50 Hz for 1 min. Insulating resistance between the inputs, the outputs and the power supply: 1 GΩ. Insulating resistance between any connection terminal and the case: 1 GΩ. Working conditions Working temperature: -20 / +50ºC. Use: indoor. Constructive characteristics Case material: ABS self-extinguishing (as per UL 94 V1) and high resistance against impacts. Protection degree: Case: IP 52 / Terminals: IP 20 Screwed transparent cover for the adjustment push buttons. Safety Category I, EN-61010. Standards IEC 255-5, IEC 1010-1, EN 61010-1, IEC 801-2, IEC 801-3, IEC 801-4. Page nº 14

Dimensions: Panel hole: 92 mm +0.8 x 92 mm +0.8 7.- SAFETY CONSIDERATIONS All installation specification described at the previous chapters named INSTALLATION AND STARTUP and SPECIFICATIONS. Note that with the instrument powered on, the terminals could be dangerous to touching and cover opening actions or elements removal may allow accessing dangerous parts. This instrument is factory-shipped at proper operation condition. Page nº 15

8.- MAINTENANCE The MEG-1000 does not require any special maintenance. No adjustment, maintenance or repairing action should be done over the instrument open and powered and, should those actions are essential, high-qualified operators must perform them. Before any adjustment, replacement, maintenance or repairing operation is carried out, the instrument must be disconnected from any power supply source. When any protection failure is suspected to exist, the instrument must be immediately put out of service. The instrument s design allow a quick replacement in case of any failure. 9.- TECHNICAL SERVICE For any inquiry about the instrument performance or whether any failure happens, contact to CIRCUTOR s technical service. CIRCUTOR S.A. - After sales service Vial Sant Jordi, s/n 08232 - Viladecavalls (Barcelona) - España tel - (+34 ) 93-745 29 00 fax - (+34) 93-745 29 14 E_Mail: central@circutor.es Page nº 16