ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

Similar documents
O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

DELI MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK. Featuring. Technology P902077H. Rev 4 1/07 COMPONENT

DELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT

DELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION

REAR LOAD DAIRY INSTALLATION & OPERATION HANDBOOK P056170D. Rev /10 COMPONENT

RM with INNOVATOR Doors

OWIZ/OWIZV OWEZ/OWEZV

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

RL with INNOVATOR II No Heat Doors

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

FG-L Technical Data Sheet

ORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11

MULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL. Table of Contents

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

RLT with INNOVATOR Doors

RLNIE with INNOVATOR II

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

ISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT

P/N _F NSF Certified June 2010

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

Installation & Service Manual

QDV5V - 1 Door Standard (Gemtron)

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Engineering Plan Views

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

Nosing Heater. Return Grill Heater

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

RMN with INNOVATOR Doors Technical Data Sheet

ORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX...

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

IMPORTANT KEEP IN STORE FOR FUTURE USE

Installation & Service Manual

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

Installation & Service Manual

PWEE Technical Data Sheet

QC BEVERAGE/DAIRY/DELI

Installation & Service Manual

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

Installation & Service Manual

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

DAIRY/DELI PRODUCE C A S E S O5DMA INSTALLATION & OPERATION HANDBOOK. P056442G Rev /13

Case Study of Adding Glass Doors to Multi-Deck Meat Case

S2SGC MEAT/SEAFOOD MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

INSTALLATION & OPERATION MANUAL

CDC-R & CDC-D BAKERY MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

INSTALLATION & OPERATION MANUAL

QM5, QM5G Multi-Deck Meat Display Case. Part Number: 31E03028 Date: 08/13/2007

INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15

HVI-4-406R/HVI-4-408R

MODEL RD-8 Self Contained MODEL RD-2

INSTALLATION AND SERVICE MANUAL REMOTE TYPE DISPLAY CASE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

Low Flow Unit Coolers

Unico Training. Welcome to Unico!

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Field Top Mounted Condensing Unit

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

SERVICING SUPERMARKET REFRIGERATION EQUIPMENT By: Kenneth S. Franklin National Service Manager Hussmann Refrigeration, Inc.

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

Transcription:

GENERAL "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. 3rd row or nose lights are not available. SHIPPING WEIGHT Case --- Weight

ELECTRICAL DATA Fans Per Case Anti-Condensate Heaters High Effciency Fans 120 Volts 120 Volts Amps Watts Amps Watts 2 0.40 28.0 0.99 118.2 LIGHTING DATA Lights per row Lights Length Clearvoyant LED Lighting (Per Light Row) Standard Power (Cornice or Shelf) High Power (Cornice) 120 Volts 120 Volts Amps Watts Amps Watts 1 5' 0.06 7.5 0.15 18.5 GUIDELINES AND CONTROL SETTINGS Front Sill BTUH/ft Superheat Set Evaporator Discharge Discharge Air Application Height Conventional Parallel Point @ Bulb ( F) ( F) Air ( F) Velocity (FPM) Dairy/Deli/Produce All 5372 4589 6-8 28 31 150 Meat Extended 5486 4686 6-8 26 30 150 DEFROST CONTROLS Timed-Off Defrost Defrosts Per Day Fail-Safe 6 30 47 Listed BTUH/ft data represent unlighted shelves. For LED lighting, add 9 BTUH/ft per row of lighted shelving. BTUH load increases by 123 BTUH/ft when aftermarket merchandising accessories are utilized. Listed evaporator temperature represents unlighted shelves. For lighted shelves and/or aftermarket merchandising accessories, reduce the listed evaporator temperature by 2 F. Conventional Discharge Air Control - Recommended Settings: Cut-in Temp + Discharge Air + 2 F; Cut-Out Temp = Discharge Air - 2 F. Listed discharge air velocity represents the average velocity immediately after defrost. Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommeded evaporator temperature is 4 F below the listed evaporator temperature. Time off defrost is recommended for medium temperature applications.

SECOND NATURE DATA BTUH/FT (DR) GPM/ft Supply Fluid Discharge Air Case Model Coils Application Front Sill Type Conventional Parallel (DR) 1 Deli Standard 5372 4589 1.31 20 31 1 Meat 2. Extended 5486 4686 1.61 20 30 1 Deli Standard 5372 4589 3.37 25 31 1 Meat 2. Extended 5486 4686 4.82 25 30 SECOND NATURE DATA Timed-Off Defrost Warm Fluid Defrost Case Model Coils Application Front Sill Type Defrost Fail Safe Fail Safe 1 Deli Standard 6 60 47 26 49 1 Meat 2. Extended 6 60 47 26 49 1 Deli Standard 6 45 47 26 49 1 Meat 2. Extended 6 45 47 26 49

REAR SILL OPTIONS ORIGIN 2 FRONT OPTIONS CLASSIC 2 POLYMER CLASSIC 2 METAL 16" [40.6 cm] 16" REAR SILL (FRONT DISCHARGE) 21 3/16" [53.8 cm] 21 3/16" [53.7 cm] 21 3/16" [53.7 cm] 20 1/8" [51.0 cm] 20" REAR SILL (FRONT DISCHARGE) Extended front sills are required to meat applications to maintain proper product temperature. An extended front has a minimum height of 24" on a baseframe, or 30" on an baseframe.

20 1/8" [51.1 cm] 61 3/4" [156.8 cm] SHIPPING HEIGHT 59 1/2" [151.1 cm] CASE HEIGHT 33 15/16" [86.1 cm] INTERIOR DISPLAY [27.9 cm] 12" 1 LOAD LIMIT 12" 1 14" 16" 24 7/8" [63.2 cm] COIL PLENUM 24 1/4" [61.6 cm] 25 1/8" [63.8 cm] STANDARD FRONT 22 7/8" [58.1 cm] 28 1/16" [71.3 cm] THROAT DISPLAY 27 1/8" [68.9 cm] 55 7/8" [141.9 cm] SHIPPING HEIGHT 53 5/8" [136.2 cm] CASE HEIGHT 5 1/8" [13.0 cm] 14" 16" STANDARD FRONT COIL PLENUM 3 7/8" [9.8 cm] 29" [73.6 cm] LOAD LIMIT 17" [43.2 cm] 21 1/4" [54.0 cm] 35 7/8" [91.1 cm] REAR REFRIGERATION LOCATED 12 1/4" ABOVE FINISH FLOOR 17 1/2" [44.5 cm] 14 1/2" [36.8 cm] 2" MINIMUM AIR GAP 2" [5.1 cm] 14 3/8" [36.5 cm] 10 1/2" [26.7 cm] 6 1/2" [16.5 cm] 35 13/16" [91.0 cm] 24" [61.0 cm] ELECTRICAL 24 1/4" [61.6 cm] 29 3/8" [74.6 cm] WIRING TO BALLAST TRAY (STANDARD) (CONNECTION MUST BE FLEXIBLE TO FRONT OF CASE) 27" [68.5 cm] 1 1/2" PVC DRAIN CONNECTION 73 1/8" [185.7 cm] * : STUB-UP AREA ** : RECOMMENDED STUP-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS 1 : AVAILABLE SHELF SIZES: 10", 12", 14" & 16" Ends add approximately 1" to case height