Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Similar documents
Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Product Data 58VMR FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. S Unit may also be sidewall vented with an approved A S OVM units equipped with ECM 2.3 Variable Speed

Product Data. 367AAN Low --- Boy Oil Furnace Input Capacities: 70,000 thru 154,000 BTUH Series E 367AAN FEATURES/BENEFITS

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. S UTEC ignition control and fan timer board provide. S S Cabinet features an insulated enclosure for the burner

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. FH4A Fan Unit. Sizes 001 thru 004

395CAV Sizes 045 thru 155 Series H and J

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data STANDARD FEATURES

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

TECHNICAL SPECIFICATIONS

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

355MAV Sizes 040 thru 120 Series E

Product Data. FH4A Fan Unit. Sizes 001 thru 004

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

MERIT SERIES Downflow

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

Product Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

RE9X Series Downflow, Upflow Electric Furnaces

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Cooling Capacity CFM in. w.c. (125 Pa)

RG7D 1-Stage Heat Series

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

PREMIUM OIL Furnaces. Variable Speed Option. Up to 87.5% Efficiency Optional Cooling Up to 4 Tons High-Grade Stainless Steel Heat Exchanger FEATURING

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

8+* Bulletin No November 1997

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Cooling Capacity CFM range

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

ELITE SERIES Downflow - High Efficiency Blower Motor

Product Data. IdealComfortt technology, the ultimate in heating comfort...

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Wt. Lbs Model Number (BTUH) Hz

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

PLUS 95st MODEL 355CAV DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

RGE 13 A T - 1 A

FAN UNIT FH4A Sizes 001 thru 004

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Transcription:

Product Data 58CMA Multipoise Oil Furnace Series 110 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CMA combines high efficiency and quiet operation with the latest oil heating technology. The 58CMA is available in 2 sizes. Each size can be fired at 3 different rates by a simple nozzle change. Unit 58CMA105 covers input ranges from 70,000 to 105,000 Btuh. Unit 58CMA120 covers input ranges from 119,000 to 154,000 Btuh. The furnace design is a multipoise style for upflow, downflow, and horizontal applications. The components of the 58CMA are the finest in the industry. The unit uses a oil burner with a Honeywell ignition control and fan timer control. The 58CMA is a standard part of a quality-built home. This energyefficient furnace will provide years of quality service to home builders and homeowners alike. As with other Carrier furnaces, this model is designed to work as part of a total home comfort system which includes elements for cooling, air cleaning, humidification, ventilation, and zoning. 58CMA FEATURES/ BENEFITS Casing Made of 20 gage powder painted steel for years of durability and attractiveness. The cabinet features a reversible door ensuring ease of service access even in downflow applications. Certifications The 58CMA unit is UL and ULC certified. The Copyright 2001 Carrier Corporation Form 58CMA-3PD

efficiency is GAMA efficiency rating certified. Warranties Limited Lifetime Warranty on combustion chamber/heat exchanger assembly. Five-year Warranty on burner. Two-year Warranty on Honeywell ignition control. Contact your dealer for details. Combustion Products Venting Top or side flue outlets. Unit may be vented using Type L vent material and a factory-built metal or masonry chimney. The unit may also be sidewall vented with an approved power venter. Insulation and Soundproofing A unique silencer baffle along with insulated walls and rubber blower mounts, efficiently captures most combustion noise and vibrations and makes this unit 1 of the quietest on the market. Adjustable Blower Speed Fourspeed blower for precise airflow selection of heating or cooling operation. Constant Low-Speed Blower Switch Allows continual low-speed air circulation through the home to maximize comfort while maintaining efficiency. Air is constantly filtered and stagnant air is avoided. This option can be controlled by the homeowner. Oil Burner and Honeywell Controls High quality oil burner allows safe and efficient combustion of oil. Honeywell ignition control and fan timer board provide for reliable operation and easy connection of thermostat and accessory wiring. Combustion Chamber/Heat Exchanger Composed mainly of stainless and aluminized steel, the unique combination combustion chamber/heat exchanger resists corrosion, overheating, and deterioration. Its heat transfer properties make it energy efficient. All seams are tightly welded for leakfree operation. Model number nomenclature 58CMA 105 110 12 Multipoise Oil Furnace Input Capacity 105 70,000 Btuh with 0.50 gph nozzle 91,000 Btuh with 0.65 gph nozzle 105,000 Btuh with 0.75 gph nozzle 120 119,000 Btuh with 0.85 gph nozzle 140,000 Btuh with 1.00 gph nozzle 154,000 Btuh with 1.10 gph nozzle Series Cooling Size Airflow (Nominal 400 CFM per 12,000 Btuh Cooling) 12 1200 CFM ama 2

UNUSED LEADS 2 3 E A C 1 2 3 C C H O OOL EA NT T 4 5 6 7 H U M X C S N ON 1 2 G W R Y C COMBUSTION CHAMBER/ CONTROL CENTER OIL BURNER HEAT EXCHANGER ELECTRONIC OR MECHANICAL AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. HUMIDIFIER By adding moisture to winterdry air, a Carrier humidifier can often improve comfort and keeps woodwork, wallpaper, and paint in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. CONTROLS: THERMOSTATS AND ZONING Available in programmable and non-programmable models, Carrier thermostats maintain a constant, comfortable temperature level in the home. For the ultimate in home comfort, Carrier s 2, 4, and 8 zone systems allow temperature control of individual zones of the home. This is accomplished through a series of electronic dampers and remote room sensors. The 4-zone system is shown. ENERGY/HEAT RECOVERY VENTILATOR Carrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level. Especially useful for today s tighter constructed houses. Energy recovery ventilator is shown. 3

6 7 8 5 4 3 9 2 10 11 1 SEE NOTES: 13, 14 Left side, right side, or bottom. 12 1 Heavy-duty blower circulates air across the heat exchanger to transfer heat into the home. 8 Reversible door provides easy access to burner and controls. 2 3 Stainless steel combustion chamber/primary heat exchanger. Unique silencer system reduces combustion noise. 9 10 High-performance oil burner. Manual switch to allow user control of constant low-speed blower operation. 4 5 6 7 Heat exchanger designed and shaped to efficiently transfer heat from furnace into the home. Fully insulated internal walls to minimize heat loss, and reduce sound. Supply-air plenum. High limit control to prevent overtemperature operation. 11 12 13 14 Adjustable electronic fan timer control (inside) has low-voltage electrical terminal strip for easy connection of thermostat, cooling control, electronic air cleaner, and humidifier. Access door to blower. Air filter (field supplied). Return-air plenum. 4

Carrier accessories UNIT SIZE 105-12 120-20 ELECTRONIC AIR CLEANER Model AIRA MECHANICAL AIR CLEANER Model MACA AIR CLEANER CABINET Model MPKA HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV THERMIDISTAT CONTROL NON-PROGRAMMABLE TSTATCCPRH01-B THERMIDISTAT CONTROL PROGRAMMABLE TSTATCCPRH01-B THERMOSTAT NON-PROGRAMMABLE THERMOSTAT PROGRAMMABLE Physical data For Use with 1-Speed Air Conditioner TSTATCCNAC01-B For Use with 1-Speed Air Conditioner TSTATCCBAC01-B For Use with 2-Speed Air Conditioner TSTATCCN2S01-B For Use with 2-Speed Air Conditioner TSTATCCNB001 For Use with 1-Speed Heat Pump TSTATCCPRH01-B For Use with 2-Speed Heat Pump TSTATCCPRH01-B For Use with 1-Speed Air Conditioner TSTATCCPAC01-B For Use with 1-Speed Air Conditioner TSTATCCSAC01 For Use with 2-Speed Air Conditioner TSTATCCP2S01-B For Use with 2-Speed Air Conditioner TSTATCCPF101 For Use with 2-Speed Air Conditioner TSTATCCPF701 For Use with 2-Speed Air Conditioner TSTATCCPS101 For Use with 2-Speed Air Conditioner TSTATCCPS701 For Use with 2-Speed Air Conditioner TSTATPRF/REC01 For Use with 1-Speed Heat Pump TSTATCCPDF01-B For Use with 1-Speed Heat Pump TSTATCCPRH01-B For Use with 2-Speed Heat Pump TSTATCCPDF01-B For Use with 2-Speed Heat Pump TSTATCCPRH01-B COIL CASING KLAOC0101DET KLAOC0201DET Cooling Capacity Use coil shown below 1.5 and 2 tons of A/C CC5AXW024017 CC5AXW042024 2.5 tons of A/C CC5AXW030017 CC5AXW048024 3 tons of A/C CC5AXA036017 CC5AXA060024 ZONING 2 ZONE ZONECC2KIT01-B 4 ZONE ZONECC4KIT01-B 8 ZONE ZONECC8KIT01-B OIL NOZZLE KIT** NOZZLE FIRING RATE (QTY-50) 0.50 GPH-70,000 BTUH KLANZ0150050 0.65 GPH-91,000 BTUH KLANZ0250065 0.75 GPH-105,000 BTUH KLANZ0350075 0.85 GPH-119,000 BTUH KLANZ0450085 1.00 GPH-140,000 BTUH KLANZ0550100 1.10 GPH-154,000 BTUH KLANZ0650110 UNIT SIZE 105-12 120-20 INPUT (Btuh) 70,000 91,000 105,000 119,000 140,000 154,000 HEATING CAPACITY (Btuh)* 57,000 74,000 85,000 97,000 115,000 126,000 NOZZLE 100 PSIG PUMP PRESSURE 0.50 70W 0.65 70W 0.75 70B 0,85 70B 1.00 70W 1.10 70W FIRING RATE (GPH) 0.50 0.65 0.75 0.85 1.00 1.10 AFUE% Upflow 80.0 80.0 80.0 80.0 80.0 80.0 Downflow 80.0 80.0 80.0 80.0 80.0 80.0 Horizontal 80.5 80.5 80.5 80.5 80.5 80.5 OIL PUMP STAGES/PRESSURE (PSIG) 1/100 1/100 1/100 1/100 1/100 1/100 HEATING TEMP RISE F 55 85 55 85 55 85 55 85 55 85 55 85 COOLING CFM @ 0.5-IN. WC STATIC PRESSURE 1250 1250 1250 1865 1865 1865 HEATING CFM @ 0.2-IN. WC STATIC PRESSURE 840 1130 1425 1555 1890 2080 RECOMMENDED HEATING BLOWER SPEED Med-Low Med-High High Med-Low Med-High High SHIPPING WEIGHT (Lb) 230 230 230 248 248 248 BURNER MODEL (3450 RPM)** AFG-F6 * Capacity and AFUE in accordance with U.S. Government DOE test procedures. ** AFG-F6 requires field supplied and replacement burner firing head. As Factory Shipped. 5

PULL Dimensions A TOP KNOCK-OUT FOR J DIAM VENT 19 20 3 E G KNOCK-OUT BOTH SIDES FOR J DIAM VENT 19 VENT CONN C B OIL INLET (BOTH SIDES) 2 L H ELECTRICAL CONNECTIONS (BOTH SIDES).88 DIAM TYP D F K 20 DIMENSIONS (IN.) UNIT SIZE A B C D E F G H J K L 105-12 35 48-3/4 31-1/4 16-5/8 20 22 12 14 5 1-1/2 1-3/4 120-20 39-1/2 53 33-1/4 18-3/4 24 28 12-19/32 16 6 1-5/8 1-1/2 6

AIR DELIVERY CFM (With Filter) UNIT SIZE BLOWER MOTOR HP 105-12 1/3 PSC 120-20 3/4 PSC SPEED EXTERNAL STATIC PRESSURE (In. wc) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 High 1425 1350 1305 1250 1170 1030 925 805 Med-High 1130 1045 1000 950 885 820 745 670 Med-Low 840 810 770 740 685 635 580 500 Low 725 730 740 745 730 715 690 665 High 2080 2040 1965 1865 1700 1575 1475 1335 Med-High 1890 1860 1770 1675 1550 1450 1330 1215 Med-Low 1555 1475 1395 1320 1210 1135 1050 940 Low 1220 1165 1080 1000 925 855 780 655 Clearance to combustibles UNIT APPLICATION UPFLOW DOWNFLOW HORIZONTAL SIDES Furnace 0 2 2 Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1 2 1 BACK Furnace 0 1 0 TOP Furnace Casing or Plenum 2 2 2 Horizontal Warm-Air Duct Within 6 ft of Furnace 2 2 3 BOTTOM Furnace 0 0* 0* FLUE PIPE Horizontally or Below Pipe 4 4 4 Vertically Above Pipe 9 9 9 FRONT 8 8 24 * For combustible floor, use approved accessory subbase. NOTE: Adequate service clearance should be provided over and above these dimensions as required. Performance data UNIT SIZE 105-12 120-20 DIRECT-DRIVE MOTOR Hp (PSC) 1/3 3/4 MOTOR FULL LOAD AMPS 6.2 9.5 RPM (Nominal) SPEEDS 1075 4 1075 4 BLOWER WHEEL DIAMETER X WIDTH (In.) 10 X 10 12 X 10 FILTER SIZE (In.) (Disposable, Field Supplied) 16 X 24 or 25 X 1 20 X 30 X 1 7

Electrical data UNIT SIZE 105-12 120-20 UNIT VOLTS HERTZ PHASE 115 60 1 115 60 1 OPERATING VOLTAGE RANGE (Minimum Maximum)* 104 132 104 132 MAXIMUM UNIT AMPS 12.2 15.7 MINIMUM WIRE SIZE (AWG) 14 12 MAXIMUM WIRE LENGTH (Ft) 26 26 MAXIMUM FUSE SIZE OR CKT BKR (Amps) 15 20 TRANSFORMER (24v) 40va 40va EXTERNAL CONTROL POWER AVAILABLE Heating 40va 40va Cooling 30va 30va AIR CONDITIONING RELAY Standard Standard * Permissible limits of the voltage range at which the unit will operate satisfactorily. Length is as measured 1 way along wire path between unit and service panel for maximum 2% voltage drop. Time-delay type is recommended. Typical installation AIR CONDITIONER OR HEAT PUMP SUPPLY-AIR DUCT A/C COIL OIL TANK RETURN- AIR DUCT VENT PIPE CHIMNEY BAROMETRIC DRAFT DAMPER OIL FURNACE AIR FLOW A98026 Carrier Corporation Indianapolis, IN 46231 9-01 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Page 8 Catalog No. 525-80014 Printed in U.S.A. PC 101 Form 58CMA-3PD Tab 6a 8a Replaces: 58CMA-2PD