A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

Similar documents
Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

Installation & Operation

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

PRE-INSTALLATION GUIDE

PowerVac G Single to Twin Conversion Kit [ ]

DENTAL VACUUM SYSTEM Part Numbers: VS2O, VS40, VS50, VS50H, VS80 and VS80H RECOMMEND DAILY USE OF MONARCH CLEANSTREAM USER S MANUAL

Vacuum Plumbing Layout Recommendations

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install

PRE-INSTALLATION GUIDE

Ozomax Ltd Ozone generators

USER MANUAL/Installation Instructions LRV-4

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

DENTAL AIR SYSTEM. AS12, AS22, AS50 AS70, AS12C, AS22C & AS50C International. Installation and Operation Manual

PRE-INSTALLATION GUIDE

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

PRE-INSTALLATION GUIDE for MODELS

Dishwasher Installation Manual

PRE-INSTALLATION GUIDE for MODELS

PRE-INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions

USER GUIDE. Dental Compressed Air System. Installation and Maintenance Manual For 1000 CM Series with C1 Control

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Surna 25-Ton Chiller Operating & Maintenance Manual

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Owner s Manual PCS PRO

600 Series Spin-on Fuel Filter/Water Separators

TABLE 1 Electrical Specifications

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Installation Instructions

Advantage Series Bathing System Specifications

Standard Features. Performance/Capacities

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

STERI-VAC CENTRAL SUCTION SYSTEM

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

SAVE THESE INSTRUCTIONS

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

TABLE 1 Electrical Specifications. Phase

OWNER S MANUAL (English)

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Helpful Tip: NOTE:

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

HYDROGEN SULFIDE REMOVAL SYSTEMS

SAVE THESE INSTRUCTIONS

CHILLER. Operator s & Installation Manual

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

Panel Mounted Heat Exchangers by Dantherm, Inc.

SAVE THESE INSTRUCTIONS

VENTILATION FAN / LED LIGHT

SYSTEMS for CATALYTIC FILTERS

CH250 AND CH251 CHILLERS

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

Fire Bowls and Fire Bowl Inserts (Automated Operation) Operating and Maintenance Instructions

CLASSIC. SIDE CABINET Installation Instructions

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

1-866-PENNERS

Quest Power Electric Heat EHS 31 Pro

ERGOMAX 7 INSTALLATION

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Owner s Manual. Terpene Trap CF 1000

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation Manual CARBONATOR With Plain-Water Booster

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

USER MANUAL SAVE THESE INSTRUCTIONS

Operator s Manual. IP-100 Immersion Probe Cooler

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets

VACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL

LC Series - Light Commercial Pump Station Installation and Operation Manual

LIBBE BASIC INSTRUCTIONS & MEASUREMENTS. 8 (2.44 meter) (73.66 cm) 5 2 (1.6 meter) Approximately 6 (1.83 meter)

MODEL CDB8 INSTALLATION INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

Liebherr's engineering excellence in Germany provides the largest selection of freezers, refrigerators and wine refrigerators worldwide.

SMARTBOOST IMPORTANT SAFETY INFORMATION

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

OPERATING INSTRUCTIONS

Installation instructions for the T 9820 Gas Dryer

WINE AND BAR SERIES. Sink Installation Kit. For assistance, call ; for UK ; at

Installation, Operation and Maintenance Manual

Top Control Dishwasher

MDH Series Air Dryer. User s Guide

Installation Instructions PRO SERIES

R E D I C O N T R O L S

Transcription:

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y Rev 2/15 D a n s e r e a u (8 0 0 ) 423-5657 / WWW.DHPDENTAL.COM

CUSTOMER SUPPORT INF ORMATION Dansereau Health Products, Inc. has been manufacturing Dental Equipment for over 40 years. We have compiled a significant amount of data and information regarding the manufacturing, use and maintenance of dental equipment. Information contained in this manual will assist you in use and maintenance of your Dansereau equipment. We offer the most comprehensive 5 year warranty on USA manufactured dental vacuum systems today. SUPPORT ACCESS Dansereau Health Products, Inc. 1581 Commerce Street, Corona, CA 92880 Toll Free (800) 423-5657 Phone (951) 549-1400 Fax (951) 549-1411 Website-WWW.DHPDENTAL.COM TESTING LABORATORIES ETL Testing Lab.- Report #530937 Medical and Dental Equipment Category - 6 - UL 544-2nd Ed. CAN/CSA Testing Laboratories- Report #531003 Canadian Standard for Medical Electrical Equip. No 601.1 M90 US Food and Drug Administration Medical Device Registry- #202716 Dental Equipment: Classification B (Inside Use Only) IPX4 Environmental Conditions for Storage and Transport: 40 degrees (4 Degrees C) Min. / 100 Degrees (38 Degrees C) Max. Site Conditions: 40 degrees (4 Degrees C) Min. / 100 Degrees (38 Degrees C) Max. Installation Conditions - Inside DAMAGED FREIGHT Dansereau utilizes superior packaging procedures, however shipping accidents can occur. It is your responsibility to note any unusual conditions or subsequent damage to the shipping crate on the Bill of Laden prior to acceptance and signature for the product received from the freight carrier. After opening of boxes, concealed damage should be noted and reported immediately to Dansereau and the freight carrier. All freight is shipped FOB, Corona CA. and although Dansereau is not responsible for the damage we will support you in all claims and will send replacement parts immediately. PRODUCT RETURNS: Dansereau manufactured products are made to order and a 25% restocking fee may apply on returned orders. Returned orders on installed equipment is not available. 1

PRODUCT DESCRIPTION VACUUM PUMP SYSTEM The Vacuum Pump system is installed in a Utility Room in the typical dental office and is primarily used for oral evacuation of debris from the patients mouth. Recent changes in the industry have required manufacturers to add accessory items in order to properly meet upgraded and current installation standards as noticed by Uniform Building Codes. Below are listed items that may pertain the installation of the vacuum system in your dental office. 1) Air/Water Separator: The function of an Air/Water Separator is to allow the liquid waste evacuated from the patients mouth to be separated from the air born particles. The Air/Water Separator is installed after the vacuum pump and before eth drain or floor sink. A 2 vent pipe is required for correct installation of the separator. Picture Below: 2HP Air Wa- 1HP Air / Water Separator ter Separator Low Voltage Wire to turn On and Off 2) Water Recycler: The function of the Water Recycler is to allow the water used in the operation of the Vacuum Pump to be re-used, thus reducing the water usage in the dental office. 3) Boost Transformer: The function of the Boost Transformer is the increase the incoming line voltage to the Vacuum Pump. The voltage in some area s may be below the required level to properly operate the Vacuum Pump. All Vacuum Pumps require a 120volt or 208volt incoming electrical source, if the power source fluctuates or does not meet this requirement a Boost Transformer will be required. It is rare to not have adequate voltage within the USA or North America. Refer to a licensed electrician if you have questions regarding your power source. 4) Operating Information; Start of the Day: Prior to turning on your DHP Precision Vacuum System verify the water system is turned on. Turn on the Vacuum System, it is designed as a continuous run system, therefore you can operate the system all day without turning off. 2

VACUUM SYSTEM INSTAL L AT ION REQUIREMENTS Installation Requirements: 1) 5 x 5 Utility Room requires No Less Than 5 Air Changes Per Hour with Ventilation Fan 2) Dental Vacuum Systems cannot be installed in Patient Care Area. Vacuum Systems has a Potential Risk of Safety Hazard and consideration must be taken to ensure Vacuum System must not be installed adjacent to Patient Care Area. It is recommended the Utility Room has a lock only permitting staff and authorized personnel entrance to room. 3) Dental Vacuum System Requires Dedicate Electrical Circuit ( Refer to Chart Below for specifications). Vacuum System is supplied with Main Supply Power Disconnect. See Picture: 4) Vacuum Pump requires 6 inch clearance from adjacent structures or walls. Electrical and Plumbing Requirements: Refer to Chart Below: Electrical DHP101 DHP202 DHP303 Voltage Rating *120/230V - 14/7A /60hz 230 V/7A 60Hz 230V/7A 60Hz Voltage *110/125-60Hz 208/240-60Hz 208/240-60Hz Internal Vacuum Fuse Rating 1.5A / MDL.5R 1.5A / ABC20R 1.5 / AMC20R Min/Max 208/240-60Hz Electrical Panel Breaker Size 20Amp 20Amp 30Amp Full Load Amps *16/8 13.4 21.6 Cubic Feet Per Minute 14 22 34 Water Inlet Water Pressure PSI 20-100 20-100 20-100 Flow Rate Per Pump (Gal.Min) 1 2 3 Water Temp (*F) 40-75 40-75 40-75 Vacuum Level Preset at Factory (In Hg) 10 to 12 10 to 12 10 to 12 Shipping Weight (lbs) 68 85 160 Dimensions (H"XW"XD") 14x11x11 17x11x11 22x28x16 Low Voltage: The Vacuum Pump has a Low Voltage ON/OFF capability. A 3/18 low voltage rated wire can be run from one central location to allow the Vacuum Pump to be turned on and off. DO NOT CONNECT 120v or 240v to the low voltage lines as it will cause internal damage to the Vacuum Pump System. Plumbing Requirements: 1) Cold Water Line: 1/2 Cold Water line is required for proper operation of any DHP Vacuum System. A 1/2 Female Ball Valve is required to install the cold water line from the Vacuum Pump to cold water source (Water Line Supplied by Dansereau). All Dansereau Vacuum Pumps have a Recognized Backflow Device installed to ensure no cross contamination of the Vacuum Pump to the Public Water Source, however it has been noted that some Building Departments are requesting a secondary backflow system be installed by the contractor. 3

UTILITY ROOM SPECIFI C AT I ONS Typical Utility Room Schematics NOTE: This is a Typical Utility Room configuration. Use this as a basic format for designing your Utility Room. Key elements are appropriate electrical and plumbing specs. need to be met, placement of electrical and plumbing can be modified if needed. Contact Dansereau to verify modifications prior to installation of electrical and plumbing connections. 4

VAC UUM LINE SPECIFIC ATIONS Vacuum Line: See Chart Below. Dansereau Health Products, Inc. strongly recommends Schedule 40PVC for use as the Vacuum Line. However, be aware some Building Codes require a metal type vacuum line and require Copper as the Vacuum Line. Copper will eventually deteriorate over years of service, Schedule 40 PVC will not. NOTE: IF YOUR VACUUM LINE INSTALLATION IS OUTSIDE THE SCOPE LISTED BELOW CONTACT DANSEREAU FOR SPECIAL INSTRUCTIONS. Surface Mt J Box 1 Sch 40 PVC 1-1.5 Bushing Sch 40 PVC 1.5 DWV Sanitary T Sch 40 PVC Site Requirements: Environment Conditions Operating Conditions - Indoor use at altitudes up to 2000M. Temperature 5 to 40 Degrees C (41 to 104 F) Maximum relative humidity 80% for temperatures up to 31 C, decreasing linearly to 50% relative humidity to 40C. Supply Voltage fluctuation of +/- 10% of nominal voltage. IEC 60601-1 Not suitable for use in the presence of a flammable anesthetics mixture with air or with oxygen or nitrous oxide. Class 1 Installation Category Ordinary equipment (IPXO). Does not protect against ingress of water. Unit is suitable for continuous operation. 5

VAC UUM LINE SIZING Vacuum Line Sizing Guide is recommended specifications. In order to ensure quality vacuum performance reduce the amount of angled fittings and bends in the piping system and make every effort to provide a 1/4 Grade Per Foot. DHP 101 DHP 202 * Dual DHP 303 * Triple HVE's + SE's HVE's + SE's HVE's + SE's 2 + 0 3 + 0 4 + 1 + 1 2 + 2 3 + 2 0 + 4 1 + 4 2 + 4 0 + 6 1 + 5 NOTES: HVE= High Volume Evacuator SE= Saliva Ejector * These combinations apply if all pumps are running together. If only one pump is running, Sizing Guide for DHP 101 applies. 6

VAC UUM PUMP PARTS LIST Vacuum Gauge DA1173VG - $175 Vacuum Manifold DA1173M - $175 Backflow Valve Double Check DA1156BV - $175 NOTE: Older Vacuums use Watts Valve - Double Check Vacuum Solenoid DA1179S - S $175 Vacuum Filter Canister COMPLETE DA1125C $175 Vacuum Water Hose DA1158WH - S $175 Vacuum Fuse Housing DA1237FH - $35 Clear Disposable Vacuum Canister - Replacement DA13181 - Each $25 Vacuum Relay DA11331R - $75 Vacuum Low Voltage Terminal DA1237LV - $45 Vacuum 24V Transformer DA1322VT - $75 Vacuum Pump Control Box Vacuum System Check Valve NOTE: Used on Dual or Triple Vacuum Systems DA1325 - B $50 7

VAC UUM PUMP WIRING SCHEM AT ICS 8

VAC UUM INSTAL L AT I ON GUIDE Unpacking the Vacuum Pump 1) The DHP Vacuum Pump weighs approximately 70 lbs. With the Vacuum Pump box on the floor use a knife to open the box. Remove all the inner packing material and various parts and set aside, DO NOT DISCARD ANY MATERIAL UNTIL THE VACUUM PUMP IS COMPLETELY INSTALLED. 2) Remove the inner cardboard sleeve by sliding it upward. 3) The vacuum pump is mounted to a plywood pallet carefully lift the vacuum pump out of the box - realize the vacuum pump weighs 70 lbs. DO NOT LIFT THE VACUUM PUMP BY THE WHITE PLASTIC MANIFOLD (See diagram A below) - LIFT THE VACUUM PUMP BY THE BASE HOUSING. 4) Locate the three rubber mounting feet stapled to the wood platform the vacuum pump is attached. Remove the vacuum pump from the wood platform. Install the three rubber mounting feet. Be careful not the hold the vacuum pump by the white plastic manifold. Vacuum Pump location 1) Set the vacuum pump on a level surface. A vinyl or tile surface is strongly recommended, carpeting and or wood surfaces may mildew and deteriorate over several years of use. Vacuum Pump water source installation 2) The water source line to the vacuum pump is a flexible burst proof blue tubing with a threaded fitting on the end. The blue tubing is designed to easily attach to the water ball valve that has been installed as per the pre-installation guide. As per the drawing below apply either plumbers putty or teflon to the male portion of the connection. After the teflon tape or the plumbers putty has been applied thread the water source burst proof blue tubing and hand tighten with an 11/16" open end wrench. DO NOT OVER TIGHTEN - After the water source line is tight turn on the water and check for water leaks. 10

VAC UUM INSTAL L AT I ON GUIDE Vacuum Pump Intake and Exhaust Installation 1) Locate the flexible white PVC tubing supplied by DHP and attach to the intake portion of the vacuum pump (labeled on the vacuum pump). 2) Locate the operatory vacuum line source( the plumber installed in the dental office )and attach the intake portion of the flexible white PVC tubing to the operatory vacuum line source. 3) Locate the second flexible white PVC tubing and attach to the exhaust portion of the vacuum pump (labeled on the vacuum pump). 4) If you choose to use a vacuum separator you will attach the exhaust portion of the flexible white PVC tubing (now attached to the vacuum pump) to the vacuum separator. Refer to the Vacuum Separator installation manual for additional instructions. If you choose not to use a vacuum separator the flexible white PVC exhaust hose will drain directly into the floor sink or plumbing 'P' trap. It is strongly recommended that the exhaust hose have a 1" air gap as per most local building codes. Electric Installation IT IS EXTREMELY IMPORTANT THAT THE ELECTRICAL SOURCE AT THE ELECTRICAL PANEL BE TURNED OFF UNTIL THE VACUUM PUMP IS COMPLETELY INSTALLED. 1) Locate the electrical junction box at the end of the metal flexible conduit attached to the gray metal vacuum pump junction box. This is the 115 volt electrical source for the single horsepower vacuum pump system or the 230 volt electrical source to the 2 horsepower vacuum pump system. 2) It is strongly recommended that the electrical portion of the vacuum pump installation be done by a qualified licensed electrician. 11

M AN UFAC T U RER S WARRANTY Dansereau has the most comprehensive product warranty programs available to the dentist today. We offer a 5 Year Warranty on our Wet Vacuum Pump Systems, complete features are listed below: Upon Installation of the Dansereau DHP Precision Vacuum System your warranty is automatically registered with Dansereau 5 Years 100% Vacuum Pump Electric Motors, Brass Housing and Impellar, Manifold System, Pressure Gauge, Solenoid Valve, Solenoid Coil, Transformers, Relays and Double Check Valve. Vacuum Filters are maintenance items and not covered under warranty. Broken or User Damaged Items are Not Covered under Warranty. Minimum Maintenance is required in order to guarantee full use of warranties DHP Precision Vacuum System require not lubrication or maintenance other than routine filter changes. You can visit our website WWW.DHPDENTAL.COM to view a video on the filter change method. GUARANTEE Dansereau will guarantee against defects in material and workmanship. Defective parts will be repaired or replaced: no claim for labor or consequential damages will be allowed. All replacement parts claimed defective will be filled in the usual manner, such invoice being subject to adjustment after the alleged defective material has been returned and inspected by the manufacturer. The warranty does not cover damage resulting from improper installation, maintenance, accident or misuse. 12