AT-G-SENSE Gas Sensing System

Similar documents
Installation & Operation

AT-G-SENSE Gas Sensing System

MGS Murco Gas Sensor EC / SC model Gas Detector and Transmitter. Installation & Operation* 08 ASH (1)

MGD - Murco Gas detector / Monitor. Installation & Operation* 08 ASH (1)

Danfoss Gas Sensor DGS MODBUS

AT-G-DETECT Gas Sensing System

AquiTron DATA S HEET. AT-GU Commercial Refrigerant Sensor

Integrated Area Monitor and Optional 16-Channel Controller Installation and Operation Manual Instruction Rev 1 March 2014

Leak Monitors. Installation & Operation* 1- Installation Instructions. 2- Location Instructions. 3- Typical Settings. 4- Operating Instructions

Gas Detector. Installation and Operation Manual Instruction Revision 3 August Product Leadership Training Service Reliability

LKD USER MANUAL. Detection and indication of refrigerant leaks MANAGEMENT AND MONITORING

Installation, Operation and Maintenance Manual

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1)

MGS-350 Gas Detector Installation and Operation Manual Instruction Revision 1 February 2013 Product Leadership Training Service

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

DGS - Danfoss Gas Sensor Check / Calibration Procedure

AquiTron. AT-WM Water Monitor DATA SHEET

Danfoss Gas Sensor Type DGS-SC and DGS-IR with MODBUS

Macurco HD-11 Hydrogen Gas Detector

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

GL-CO-RFG Channel Gas Leak Alarm System

Warranty Registration

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

aquilar - leak detection solutions

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Operation Manual. Rev ART Infrared Refrigerant Transmitter.

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Warranty Registration

INSTALLATION AND OPERATING INSTRUCTIONS

aquilar - leak detection solutions

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

TECHNICAL INSTRUCTIONS

IR200 INFRARED HCFC & AMMONIA (NH3) REFRIGERANT SENSOR. User Manual

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Ammonia Detection System Codes and Design Specifications

MACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

CA5000 Liquid CO 2 Freezer Backup System

Cable Actuated Sensor Industrial User Scalable VDC Output

VGPS-evo V3.3. Installation Instructions. The VGPS-evo is a gas pressure proving system with ventilation interlock and optional CO2 detection.

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Cable Actuated Sensor Industrial User Scalable 4 20mA

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

MGC Dock User s Manual

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

MGC Dock User s Manual

GLD-30 Gas Leak Detector

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

GPPS-evo V3.3. Installation Instructions

KM300 Carbon Monoxide Detection System Installation Manual

Industrial Strength Leak Detection

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

GS100M Gas Detection Controller

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

FDM Series. User Manual. SKOPE Food Display Cabinet Integral models: FDM900i/1200i/1500i. Model FDM1200i

86BSD Digital Output

86BSD Digital Output

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GAS MONITOR Model Model

Warranty Registration

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

QuickStat-TC Installation & Operation Manual

TE Connectivity's AMP NETCONNECT Cable Management

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

BX444-Mc Gas Detector

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

USER S INFORMATION MANUAL

BEP Marine Gas Detector 600-GDRV

External Wireless Sounder

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

HALOGUARD TM II MULTI-GAS MULTI-SENSOR MONITOR INSTRUCTION MANUAL

Controllers. Instruction Manual WARNING

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

! "! # Please read these installation and operating instructions completely and carefully before starting.

Please read this sheet as it contains important information

Document No

External Wireless Sounder

GS100M Gas Detector. Technical Specification

Door Release Power Supply

Model 405 AIRGARD Fume Hood Monitor

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

3 Macurco Carbon Monoxide Detector CM-16A

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

Transcription:

AT-G-SENSE Gas Sensing System INSTALLATION & OPERATING MANUAL INSTALLATION INSTRUCTIONS Open the AT-G-SENSE by undoing the two screws. Remove metal faceplate, turn over and check connection terminals (maximum wire size into terminal block 2.5mm). See diagram below and then: 1. Connect the output to the remote AT-GSC-16 at CN6 (see diagram below) using two-wire cable (7/0.2mm alarm cable up to 500m). It does not matter which wire goes into which terminal. If installing a stand alone AT-G-SENSE please ignore. 2. Relay outputs connect to NO or NC as required for one or both relays at position CN4 and CN5. Relays are rated at 24Vdc / 120Vac 1A max (connector block max wire size 2.5mm) 3. Set relay and sounder response delay using jumpers on header HD1 at position 1 & 2. Factory default setting is 0 minutes. 4. Set latch using jumper on header HD1 at position 3. Factory default is Manual Reset. 5. Set sounder condition using jumpers on header HD1 at position 4. Factory default is Enabled. 6. Set remote reset facility using jumper on HD1 at position 5. Factory default is Enabled. 7. Connect mains 230V LNE to terminal CN3 labeled LEN (connector block max wire size is 2.5mm) 2. Location Of Sensors Sensors must be located within the appropriate wire lengths from the central control unit. In all cases the sensor supplied is designed for maximum sensitivity to a particular gas. However, in certain circumstances false alarms may be caused by the occasional presence of sufficiently high concentrations of other gaseous impurities. If such a situation is likely to arise installers should check with our Technical Department so that sensor(s) of suitable cross sensitivity can be supplied. Examples of situations where such abnormalities may arise include - Plant room maintenance activity involving solvent or paint fumes or refrigerant leaks. Plant rooms in fruit ripening/storage facilities because of accidental gas migration (bananas - ethylene, apples - carbon dioxide) Heavy localised exhaust fumes (carbon monoxide, dioxide) from engine driven forklifts in confined spaces or close to sensors. A response delay is built in to the system to minimise the possibilities of false alarms. Air Conditioning Direct systems VRV/VRF EN378 states that detectors to ensure safety have their sensors located in such positions that they monitor the concentration at heights of the occupants of a human occupied space taking into account the characteristics of the refrigerant used e.g. at less than bed height with heavier than air gases in a hotel room. It also states that ceiling voids are regarded as part of the human occupied space. In a hotel room monitoring in ceiling voids would not strictly comply with EN378 Do s Mount the in-room sensor at less than the normal heights of the occupants e.g. in a hotel room this is less than bed height between 200-500mm off the floor. Keep away from draughts and heat sources like radiators etc. Avoid sources of steam. Don ts Do not mount sensors under mirrors, at vanity units or in or near bathrooms.

Machinery Rooms There is NO ABSOLUTE RULE in determining the number of sensors and their location. However a number of simple guidelines will help to make a decision. Sensors monitor a point as opposed to an area. If the gas leak does not reach the sensor then no alarm will be raised. Therefore, it is extremely important to carefully select the sensor location. Also consider ease of access for maintenance. The size and nature of the site will help to decide which method is the most appropriate to use. Locations requiring the most protection in a machinery or plant room would be around compressors, pressurized storage vessels, refrigerant cylinders or storage rooms or pipelines. Most vulnerable are valves, gauges, flanges, joints (brazed or mechanical), filling or draining connections etc. When mechanical or natural ventilation is present mount a sensor in the airflow. In machinery rooms where there is no discernable or strong airflow then options are: Point Detection, where sensors are located as near as possible to the most likely sources of leakage, such as the compressor, expansion valves, mechanical joints or cable duct trenches. Perimeter Detection, where sensors completely surround the area or equipment. With heavier than air gases such as halocarbon and hydrocarbon refrigerants such as R404A, propane and butane, sensors should be located near ground level. With lighter than air e.g. ammonia, the sensor needs to be located above the equipment to be monitored e.g. on a bracket or high on a wall within 300mm of, or on the ceiling provided there is no possibility of a thermal layer trapped under the ceiling preventing gas reaching the sensor. (NB. At very low temperatures, such as in a refrigerated cold store, ammonia gas becomes heavier than air). With similar density or miscible gases, such as CO or CO2, sensors should be mounted about head height 1.5m. Sensors should be positioned a little way back from any high-pressure parts to allow gas clouds to form. Otherwise any leakage of gas is likely to pass by in a high-speed jet and not be detected by the sensor. Make sure that pits, stairwells and trenches are monitored since they may fill with stagnant pockets of gas. If a pressure relief vent pipe is fitted to the system, it may be a requirement to mount a sensor to monitor this vent pipe. It should be positioned about 2m above the PRV to allow gas clouds to form. With racks or chillers pre-fitted with refrigerant sensors, these should be mounted so as to monitor the compressors or if extract ducts are fitted the airflow in the duct may be monitored. Refrigerated Spaces In refrigerated spaces sensors should be located in the return airflow to the evaporators on a sidewall, below head height preferred, or on the ceiling, not directly in front of an evaporator. In large rooms with multiple evaporators, sensors should be mounted on the central line between 2 adjacent evaporators, as turbulence will result in airflows mixing. 3. Typical Settings Gas: Refrigerant R410A Alarm Set Point: 1% (10,000ppm) For a particular unit please refer to the gas settings shown on the rating plate. 4. Installation and Wiring Diagram

5. AT-GSC-16 - Installation and Wiring Diagram

6. AT-G-SENSE - Operating Instructions 1. On powering up it will sense the presence of gas after an initial warm-up delay of 5 minutes, the green LED will flash at one second intervals during the warm-up. 2. In an alarm condition: The green LED stays on The red LED will be on The siren operates (if it has not been disabled and after a delay if this option has been selected). The relay output activates (after a delay if this option has been selected) External interface to the AT-GSC-16 panel will be turned on. The mute button on the exterior of the case may be pressed. (This will switch the sounder off if the sounder disable option is not selected) The reset button is accessible via a hole in the front panel, above the green LED, this may be pressed to reset the alarm if the manual reset option is enabled (reset is only effective when the gas has cleared from around the alarm unit, indicated by the red LED turning off). A non-metallic object such as a match or toothpick should be used to operate the reset button. If automatic reset is enabled, the alarm will reset by itself without user intervention. 3. Fault Condition: The green LED will be off The red LED will be on External interface to the AT-GSC-16 panel will activate and show the fault condition on that panel 7. AT-G-SENSE Test / Function Instructions The AT-G-SENSE is calibrated in the factory and does not require calibrations on installation. After installation, the units should be bump tested. Expose the sensors to test gas (appropriate to the installation) or crack open the valve of a cigarette lighter without igniting it and hold it over the vent holes on the upper side of the AT-G-SENSE. The gas is heavier than air and should fall into the AT- G-SENSE. This will put the system into alarm. The red LED will light showing the system is in alarm. The delay will prevent the siren sounding and relay switching for the preset delay, if delay is set. To test the siren and or relay function, check the delay is set at zero using the header at HD1 positions 1+2 off as shown on the installation diagram and expose to gas as above. You can mute the siren using the mute button. After the gas has cleared and the red LED has switched off you can reset the alarm condition including the relay and siren by using the reset button (this is if manual reset has been selected). Before testing the sensors on site the AT-G-SENSE must be powered up and allowed to stabilize for several hours, preferably overnight. When testing the sensors ensure that the AT-G-SENSE functions correctly, see section below. 8. AT-G-SENSE Annual Test To comply with the requirements of EN378 and the F Gas regulations, sensors must be tested annually. However local regulations may specify the nature and frequency of this test. If not the recommended procedure should be followed. Contact us for details. When testing the sensors ensure the AT-GSC-16 functions correctly: Red LED Siren (if connected) activates Relays (if connected) activate Reset operates

Check local regulations on calibration or testing requirements. 9. AT-G-SENSE Remote sensor head installation If you do not wish to surface mount the AT-G-SENSE or need to match room décor, we can supply a remote sensor with a decorative faceplate (standard: brushed stainless steel). The remote sensor is mounted in a single gang UK electrical back box 44mm deep to which the vented face plate is fitted. 1. Remove the connector from the sensor PCB to feed the cable through the trunking 2. Immediately refit the connector to the sensor board in the backbox. The AT-G-SENSE and remote sensor must be kept together as they are calibrated together and are a matched pair. Do not remove the sensor boards from a number of units at the same time in case they get mixed up. If doing so, label them or ensure you check the serial number on the main PCB and the remote sensor PCB are the same when re-installing. 3. If construction / decoration is still going on, fit a standard plastic blanking plate immediately you install the sensor in the back box to avoid dust or damage to the in-room sensor. You can fit the stainless steel facia when decoration is completed. 10. Agree selectable functions with end-users You should agree these important functions with the customer so that the system will operate as he/she requires: 1. Time Delay Response: Available on the sounder and relays to avoid false alarms, which is set with jumpers. The default delay is 0 minutes. You may wish to set to 15 minutes during start up and construction as you may have VOC s (volatile organic compounds) fumes, paint etc in the rooms. They should be reset as required. 2. Siren: The units have an internal siren. You can disable this by jumper, but the default setting is enabled. The customer may not want local alarms especially if you are connecting to a remote monitoring system. Check the customer s preference. 3. Reset: In the event of an alarm, you can have the units auto resetting or latched-out requiring manual resetting. The default is auto reset. If you are connected to a remote monitoring system you may prefer auto reset as being more convenient. However, if you prefer manual reset you will need to enter a room or wherever you have mounted the AT-G-SENSE to reset it after an alarm. If the unit is connected to an AT-GSC-16, you can also remotely reset the AT-G-SENSE on alarm if HD1 jumper is enabled on the AT-GSC-16 panel. 11 AT-G-SENSE - Troubleshooting All AT-G-SENSE units are checked and calibrated before shipping. 1. If on first powering up the unit you have a fault condition, contact us for instructions and support. 2. If subsequently you develop a fault condition, contact us for instructions and support. 3. If you experience spurious alarms in the absence of a leak, contact us for instructions and support. During operation record any alarms. Establish the cause or likely cause if no obvious leak has occurred. Report these occurrences to your supplier or Aquilar Ltd and we will advise on corrective measures. 12. AT-GSC-16 Operating Instructions 1. On powering up the green LED will flash and will stay on if there are no faults. 2. If there are faults in any sensor on the system the green LED will go off and the red LED will light indicating the sensor in fault. The output to a master or upstream panel will activate and show the fault condition also on that panel. 3. Should an alarm occur: The green LED stays on The red LED on the relevant channel comes on The relays operate The siren operates (can be muted by key switch) The output to a master or upstream operates to be indicated there as a fault downstream. 4. If all the red LED s are blinking approximately every 5 seconds on a master panel then remove the link on jumper position JP3 as this should be in the disabled position on a master panel. (Factory default setting is disabled.)

13. Mounting Instruction

Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Aquilar Limited makes no warranty as to the accuracy or completeness of the information, and disclaims any liability regarding its use. The only obligations of Aquilar Limited are those in the Aquilar Standard Terms and Conditions of Sale for this product, and in no case will Aquilar Limited be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product. Specifications are subject to change without notice. In addition, Aquilar Limited reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. Aquilar Limited Weights and Measures House, 20 Barttelot Road, Horsham, West Sussex RH12 1DQ. UK Tel: + 44 (0) 1403 216100 Fax: +44 (0) 8707 940 320 E-mail: info@aquilar.co.uk www.aquilar.co.uk Aquilar is a trademark of Aquilar Limited AquiTron is a trademark of AquiTron Limited