SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Similar documents
SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Thank you for selecting LENNOX air conditioners.

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Specifications. (Model) KSIB009-H /2500 (W) 10600/9000(Btu/h) 13000/9500(Btu/h) 1250/ / SEER 16 HSPF 9.

TECHNICAL GUIDE MODELS: DCMF/DHMF LX SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 16 SEER 1 PHASE 3/4 THRU 2 NOMINAL TONS DESCRIPTION

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Submittal Data Sheet

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Commercial High-Efficiency Condensing Units

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Samsung 360 Cassette, Single Zone, Split System

Specifications, Performance & Submittal

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

TECHNICAL SPECIFICATIONS

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Variable Speed Convertible Air Handler 5 Ton

Single - Zone Systems

Variable Speed Convertible Air Handler 2 1/2 Ton

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Specifications and Performance S2H

Variable Speed Convertible Air Handler 4 Ton

Model: Ceiling Cassette V 9k-24k

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

13 SEER CONDENSING UNITS & AIR HANDLERS

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Commercial High-Efficiency Condensing Units

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

MAC-120HE-03 Air-Cooled Chiller

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

RSG16**S1M. Split System Air Conditioner 16 SEER

PACKAGE AIR CONDITIONER

A single answer for multiple zones.

Product Data INDUSTRY LEADING FEATURES / BENEFITS

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

A single answer for multiple zones.

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

TECHNICAL GUIDE MODELS: INDOOR-DHPM/OUTDDOR-DHMF LX SERIES DUCTLESS MULTI-ZONE SPLIT HEAT PUMPS 16 SEER 1 PHASE 1.5 THRU 3.5 NOMINAL TONS DESCRIPTION

Technical Product Guide

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PAJ3. Product Specifications

Product Data. Fig. 1 - Unit 50VR -A


UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Lennox 8 Series Single Zone - R-410A

Unit Features & Benefits RQPM/RQRM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Residential and Light Commercial Ductless Systems Catalog

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Advance Release September 2009

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Geniuses at work. Residential Mini Splits

manuflow AIR CONDITIONING & HEAT PUMP PRODUCTS SEER 17

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Condensing Units & Air Handlers

R4H4. Product Specifications

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Single and Multi-Zone Ductless Split Systems

PAR5. Product Specifications

WJH4 Product Specifications

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

MACH N-407 Heat Pump Air-Cooled Chiller

Mini-Split Single-Zone and Multi-Zone Air Conditioners and Heat Pumps. Residential Catalog 2018

Advance Product Data

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Transcription:

M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating Capacity (Btu/h): Minimum Cooling Capacity (@95F) (Btu/h): Maximum Cooling Capacity (@95F) (Btu/h): Minimum Heating Capacity (@47F) (Btu/h): Maximum Heating Capacity (@47F) (Btu/h): Maximum Heating Capacity (@17F) (Btu/h): Total Capacity (W) (High/Standard/Low): Rated Power Input (W) Nominal Input Current (A) SEER / HSPF Air Flow Volume (CFM) (H/M/L) Dehumidifying Volume (pt./h) EER (Btu/W hr)/cop Indoor Unit Fan Motor Speed (r/min) (SH/H/M/L) Fan Motor RLA(A) Evaporator Pipe Diameter (inch) Row Fin Gap (inch) Coil length (L) x depth (D) x coil width (W) (inch) Output of Swing Motor (W) Fuse (A) Sound Power Level db (A)(SH/H/M/L) Sound PRESSURE Level db (A)(SH/H/M/L) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (L/W/H) (inch) Net Weight /Gross Weight (lbs) Outdoor Unit Compressor Type Compressor Oil L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Throttling Method Working Temp Range ( F) Condenser Pipe Diameter (inch) Row Fin Gap (inch) Coil length (l) x depth (D) x coil width (W) (inch) Fan Motor Speed (rpm) Output of Fan Motor (W) Fan Motor RLA (A) Air Flow Volume of Outdoor Unit (CFM) Fan Diameter (inch) Defrosting Method Sound Power Level db (A) Sound PRESSURE Level db (A) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (W/L/H) (inch) Net Weight /Gross Weight (lbs) Refrigerant Charge (oz) MCA MOP Connection Pipe Refrigerant additional charge(oz/ft) Outer Diameter Liquid Pipe (inch) Outer Diameter Gas Pipe (inch) Max Height Distance (ft) Max Length Distance (ft) 1 Sound PRESSURE Level @ 3.3 ft. db(a) 2018 Ingersoll Rand All Rights Reserved M4MLW1809A / M4TLS1809A Cooling Heating 208 / 230 / 1 60Hz 9200 10000 3100-9600 - - 3100-12000 - 5800 2814 / 2625 / 908 3517 / 2784 / 909 850 850 4.0 3.8 18.5 10.2 540 / 490 / 410 / 290 1.7 10.6 3.28 M4MLW1809A1N0 1350 / 1200 / 1050 / 750 1350 / 1200 / 1050 / 850 0.22 Aluminum Fin-Copper Tube 0.2 2-0.055 23.0 x 0.9 x 10.5 1.5 3.15 53 / 49 / 45 / 39 43 / 38 / 34 / 28 31.1 x 10.8 x 7.9 34.1 x 10.7 x 14.4 20.9 / 25.4 M4TLS1809A11N Rotary RB68EP (POE Oil) 35.0 6.60 1020 EEV 0-115 -13-75 Aluminum Fin-Copper Tube 0.28 1-0.055 28 0.7 20 900 30 0.36 1600 15.7 Automatic Defrosting 62 52 30.6 x 21.3 x 12.6 32.4 x 13.3 x 23.4 63.9 / 69.4 24.7 9.0 15.0 0.22 1/4 3/8 66 98

Unit Dimensions Indoor Unit Dimensions 9K-12K Indoor Units W D H 6 5/8 18 3/16 6 5/16 09K Φ2 3/16 Φ2 3/16 2 1/8 2 1/8 6 3 1/2 4 11/16 21 5/16 7 1/4 12K Φ2 3/16 Φ2 3/16 1 3/8 1 3/8 5 3 5/16 Unit:inch MODEL W H D 09K 31 1/8 10 7/8 7 7/8 12K 33 1/4 11 3/8 8 1/4 The dimensions in these drawings are rounded according to standard measurement.

Unit Dimensions Outdoor Unit Dimensions 9K-12K Outdoor Units 10 1/8 28 21 1/4 12 5/8 30 9/16 The dimensions in these drawings are rounded according to standard measurement. 11 1/4 Unit:inch 20

Clearance Requirements Space to the ceiling 6 in. or more Space to the wall 6 in. or more 6 in. or more Space to the wall 118 in. or more Air outlet side 66 in. or more Space to the floor The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures Space to the obstruction 12 in. or more Space to the wal l 9 7 n.or more i 20 in. or more Air inlet side 12 in. or more Space to the wall 20 in. or more Air outlet side valve cover NOTE: The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m). Air Velocity Patterns for High Wall Max Horizontal Distance Unit: ft. (m) Model Cooling Mode Heating Mode M4MLW1809A 13.1 (4) 13.1 (4)

Performance Data M4TLS1809A1/M4MLW1809A1 Cooling Mode Performance Data Outdoor Indoor Entering Air Temperature (Dry Bulb/Wet Bulb) Ambient Air Temperature 68/57 F 73/61 F 80/67 F 82/68 F ( F) TC* SHC** TC SHC TC SHC TC SHC 0 4500 3600 4800 3800 5400 4300 5600 4500 10 5400 4300 5700 4600 6400 5100 6700 5300 20 6100 4900 6500 5300 7400 6000 7700 6200 30 6500 5200 6900 5500 7800 6200 8100 6500 40 6700 5400 7100 5700 8000 6400 8400 6700 50 7000 5600 7400 5900 8400 6700 8700 7000 60 7700 6300 8300 6700 9000 7300 9800 8000 65 8300 6800 8800 7200 9500 7800 10300 8400 70 8600 7100 9200 7500 9800 8000 10500 8600 75 8600 7000 9100 7500 9700 8000 10400 8500 80 8400 6900 8900 7400 9600 7900 10300 8500 85 8200 6800 8700 7200 9500 7900 10200 8400 90 7900 6600 8500 7100 9300 7700 10000 8300 95 7700 6500 8200 6900 9000 7600 9800 8300 100 7500 6300 8000 6700 8900 7500 9600 8100 105 7300 6100 7800 6600 8700 7300 9400 7900 110 7100 6000 7600 6400 8500 7200 9200 7800 115 6900 5800 7400 6300 8300 7100 9000 7700 *Total Capacity **Sensible Heat Capacity M4TLS1809A1/M4MLW1809A1 Heating Mode Performance Data Outdoor Indoor Entering Air Temperature Ambient Air Temperature 68 F 73 F 80 F 82 F ( F) TC* TC TC TC 13 4500 4400 4300 4200 5 4900 4800 4700 4600 0 5300 5300 5200 5000 5 5600 5500 5400 5300 10 5900 5800 5700 5500 15 6000 5900 5800 5700 20 6300 6200 6100 6000 25 7000 6900 6700 6600 30 7500 7400 7300 7100 35 8100 8000 7800 7700 40 8700 8600 8500 8300 45 9600 9500 9300 9100 50 55 60 9800 10000 10200 9600 9800 10000 9400 9600 9800 9200 9400 9600 Capacities in these performance tables reflect normal operation at the temperatures indicated. See 65 10300 10200 10000 9700 specification tables for certified 70 10500 10300 10100 9800 values under prescribed test 75 10600 10400 10200 9900 conditions. *Total Capacity

Mini-Split Outdoor Unit Mechanical Specifications General This unit is fully charged from the factory for up to 25 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for outdoor application. Unit Casing The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Refrigerant Controls The compressor motor and condenser fan motor are controlled and monitored by an integrated electronic module. Additionally, the same module monitors sensors to control refrigerant flow through the sealed system as well as air flow. Compressor The compressor features internal over temperature and pressure protection; total dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise. Condenser Coil The condensor coil is constructed from aluminum plate fins and copper tubing. The coil provides air flow resistance and efficient heat transfer. Low Ambient Operation Matched Ameristar ductless products, have cooling capabilities at outdoor ambient temperatures as low as 0 F and heating capabilities at outdoor ambient temperatures as low as -13 F. Mini-Split Indoor High Wall General The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an Ameristar outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed. Unit Casing Casing shall be provided with knockouts on the right, and left of the unit to facilitate piping and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electrical terminal strip. Discharge Airflow and Distribution System Unit shall have auto swing, dual horizontal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle. Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow. Controls Units shall have the capability to be controlled remotely through wall-mounted wired options (sold separately) as well as a wireless remote option. Remote Controller The unit shall have a wireless infrared remote controller with easy reading digital display panel to start, stop and regulate the air conditioner from a distance. The wireless controller is included with all units. Healthy Filters The unit shall have an active carbon and catechin filter with the unit.the filters need to be cleaned at least once a year. 01/18 The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.

M4MLW1812A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1812A1N0A M4TLS1812A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating Capacity (Btu/h): Minimum Cooling Capacity (@95F) (Btu/h): Maximum Cooling Capacity (@95F) (Btu/h): Minimum Heating Capacity (@47F) (Btu/h): Maximum Heating Capacity (@47F) (Btu/h): Maximum Heating Capacity (@17F) (Btu/h): Total Capacity (W) (High/Standard/Low): Rated Power Input (W) Nominal Input Current (A) SEER / HSPF Air Flow Volume (CFM) (H/M/L) Dehumidifying Volume (pt./h) EER (Btu/W hr)/cop Indoor Unit Fan Motor Speed (r/min) (SH/H/M/L) Fan Motor RLA(A) Evaporator Pipe Diameter (inch) Row Fin Gap (inch) Coil length (L) x depth (D) x coil width (W) (inch) Output of Swing Motor (W) Fuse (A) Sound Power Level db (A)(SH/H/M/L) Sound PRESSURE Level db (A)(SH/H/M/L) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (L/W/H) (inch) Net Weight /Gross Weight (lbs) Outdoor Unit Compressor Type Compressor Oil L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Throttling Method Working Temp Range ( F) Condenser Pipe Diameter (inch) Row Fin Gap (inch) Coil length (l) x depth (D) x coil width (W) (inch) Fan Motor Speed (rpm) Output of Fan Motor (W) Fan Motor RLA (A) Air Flow Volume of Outdoor Unit (CFM) Fan Diameter (inch) Defrosting Method Sound Power Level db (A) Sound PRESSURE Level db (A) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (W/L/H) (inch) Net Weight /Gross Weight (lbs) Refrigerant Charge (oz) MCA MOP Connection Pipe Refrigerant additional charge(oz/ft) Outer Diameter Liquid Pipe (inch) Outer Diameter Gas Pipe (inch) Max Height Distance (ft) Max Length Distance (ft) 1 Sound PRESSURE Level @ 3.3 ft. db(a) 2018 Ingersoll Rand All Rights Reserved M4MLW1812A / M4TLS1812A Cooling Heating 208 / 230 / 1 60Hz 12100 12900 3750-12500 - - 3924-14000 - 8100 3664 / 3525 / 1100 4103 / 3810 / 1150 1150 1250 5.1 5.55 18.5 9.2 680 / 540 / 410 / 330 3.0 10.4 3.05 M4MLW1812A1N0 1350 / 1200 / 1000 / 800 1350 / 1200 / 1000 / 900 0.31 Aluminum Fin-Copper Tube 0.2 2-0.055 25.0 x 0.9 x 12.0 1.5 3.15 53 / 49 / 45 / 39 43 / 39 / 35 / 29 33.3 x 11.4 x 8.2 36.3 x 11.1 x 14.9 23.1 / 27.6 M4TLS1812A11N Rotary RB68EP (POE Oil) 35.0 6.60 1020 EEV 0-115 -13-75 Aluminum Fin-Copper Tube 0.28 2-0.055 28 1.5 20 900 30 0.37 1600 15.7 Automatic Defrosting 63 53 30.6 x 21.3 x 12.6 32.4 x 14.1 x 23.4 69.4 / 75.0 31.8 9.0 15.0 0.22 1/4 3/8 66 98

Unit Dimensions Indoor Unit Dimensions 9K-12K Indoor Units W D H 6 5/8 18 3/16 6 5/16 09K Φ2 3/16 Φ2 3/16 2 1/8 2 1/8 6 3 1/2 4 11/16 21 5/16 7 1/4 12K Φ2 3/16 Φ2 3/16 1 3/8 1 3/8 5 3 5/16 Unit:inch MODEL W H D 09K 31 1/8 10 7/8 7 7/8 12K 33 1/4 11 3/8 8 1/4 The dimensions in these drawings are rounded according to standard measurement.

Unit Dimensions Outdoor Unit Dimensions 9K-12K Outdoor Units 10 1/8 28 21 1/4 12 5/8 30 9/16 The dimensions in these drawings are rounded according to standard measurement. 11 1/4 Unit:inch 20

Clearance Requirements Space to the ceiling 6 in. or more Space to the wall 6 in. or more 6 in. or more Space to the wall 118 in. or more Air outlet side 66 in. or more Space to the floor The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures Space to the obstruction 12 in. or more Space to the wal l 9 7 n.or more i 20 in. or more Air inlet side 12 in. or more Space to the wall 20 in. or more Air outlet side valve cover NOTE: The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m). Air Velocity Patterns for High Wall Max Horizontal Distance Unit: ft. (m) Model Cooling Mode Heating Mode M4MLW1812A 29.5 (9) 19.7 (6)

Performance Data M4TLS1812A1/M4MLW1812A1 Cooling Mode Performance Data Outdoor Indoor Entering Air Temperature (Dry Bulb/Wet Bulb) Ambient Air Temperature 68/57 F 73/61 F 80/67 F 82/68 F ( F) TC* SHC** TC SHC TC SHC TC SHC 0 6800 5400 7200 5700 7600 6400 7700 6700 10 7500 5900 7900 6300 8800 7100 8900 7200 20 8200 6500 8800 6900 10000 7800 10100 7900 30 9100 6900 9300 7500 11300 8400 11500 8600 40 9700 7300 10000 8000 11700 8800 12000 9100 50 10000 7800 10600 8400 11900 9200 12200 9600 55 10100 7900 10800 8500 12000 9300 12300 9700 60 10400 8100 11100 8700 12100 9500 12500 9800 65 11000 8600 11700 9100 12500 9700 12700 10200 70 11400 8900 12100 9400 12800 9900 12900 10400 75 11400 8900 12100 9400 12900 10100 13200 10400 80 11100 8800 11900 9300 12900 10100 13200 10300 85 10700 8500 11700 9100 12700 9900 13000 10200 90 10500 8300 11400 8900 12400 9700 12800 10000 95 10300 8100 11100 8700 12100 9500 12500 9800 100 10100 7900 10800 8500 12000 9400 12300 9700 105 9800 7800 10600 8300 11800 9300 12200 9500 110 9600 7600 10300 8100 11600 9100 11900 9300 115 9300 7400 10100 7900 11300 8900 11600 9100 *Total Capacity **Sensible Heat Capacity M4TLS1812A1/M4MLW1812A1 Heating Mode Performance Data Outdoor Indoor Entering Air Temperature Ambient Air Temperature 68 F 73 F 80 F 82 F ( F) TC* TC TC TC 13 4500 4400 4300 4300 10 5500 5300 5200 5200 5 6400 6300 6100 6100 0 7300 7200 7000 7000 5 7700 7500 7300 7300 10 8100 7900 7700 7700 15 8300 8100 7900 7900 20 8700 8500 8300 8200 25 9600 9400 9200 9100 30 10300 10100 9900 9800 35 11000 10800 10600 10500 40 11700 11500 11300 11200 45 12600 12400 12100 12100 Capacities in these performance 50 13200 12900 12600 12600 tables reflect normal operation at 55 13400 13100 12800 12700 the temperatures indicated. See 60 13700 13300 13000 13000 specification tables for certified 65 13900 13600 13300 13200 values under prescribed test 70 14200 13800 13500 13400 conditions. 75 14400 14000 13700 13600 *Total Capacity

Mechanical Specifications Mini-Split Outdoor Unit General This unit is fully charged from the factory for up to 25 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for outdoor application. Unit Casing The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Refrigerant Controls The compressor motor and condenser fan motor are controlled and monitored by an integrated electronic module. Additionally, the same module monitors sensors to control refrigerant flow through the sealed system as well as air flow. Compressor The compressor features internal over temperature and pressure protection; total dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise. Condenser Coil The condensor coil is constructed from aluminum plate fins and copper tubing. The coil provides air flow resistance and efficient heat transfer. Low Ambient Operation Matched Ameristar ductless products, have cooling capabilities at outdoor ambient temperatures as low as 0 F and heating capabilities at outdoor ambient temperatures as low as -13 F. Mini-Split Indoor High Wall General The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an Ameristar outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed. Unit Casing Casing shall be provided with knockouts on the right, and left of the unit to facilitate piping and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electrical terminal strip. Discharge Airflow and Distribution System Unit shall have auto swing, dual horizontal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle. Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow. Controls Units shall have the capability to be controlled remotely through wall-mounted wired options (sold separately) as well as a wireless remote option. Remote Controller The unit shall have a wireless infrared remote controller with easy reading digital display panel to start, stop and regulate the air conditioner from a distance. The wireless controller is included with all units. Healthy Filters The unit shall have an active carbon and catechin filter with the unit.the filters need to be cleaned at least once a year. 01/18 The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.

M4MLW1818A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1818A1N0A M4TLS1818A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating Capacity (Btu/h): Minimum Cooling Capacity (@95F) (Btu/h): Maximum Cooling Capacity (@95F) (Btu/h): Minimum Heating Capacity (@47F) (Btu/h): Maximum Heating Capacity (@47F) (Btu/h): Maximum Heating Capacity (@17F) (Btu/h): Total Capacity (W) (High/Standard/Low): Rated Power Input (W) Nominal Input Current (A) SEER / HSPF Air Flow Volume (CFM) (H/M/L) Dehumidifying Volume (pt./h) EER (Btu/W hr)/cop Indoor Unit Fan Motor Speed (r/min) (SH/H/M/L) Fan Motor RLA(A) Evaporator Pipe Diameter (inch) Row Fin Gap (inch) Coil length (L) x depth (D) x coil width (W) (inch) Output of Swing Motor (W) Fuse (A) Sound Power Level db (A)(SH/H/M/L) Sound PRESSURE Level db (A)(SH/H/M/L) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (L/W/H) (inch) Net Weight /Gross Weight (lbs) Outdoor Unit Compressor Type Compressor Oil L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Throttling Method Working Temp Range ( F) Condenser Pipe Diameter (inch) Row Fin Gap (inch) Coil length (l) x depth (D) x coil width (W) (inch) Fan Motor Speed (rpm) Output of Fan Motor (W) Fan Motor RLA (A) Air Flow Volume of Outdoor Unit (CFM) Fan Diameter (inch) Defrosting Method Sound Power Level db (A) Sound PRESSURE Level db (A) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (W/L/H) (inch) Net Weight /Gross Weight (lbs) Refrigerant Charge (oz) MCA MOP Connection Pipe Refrigerant additional charge(oz/ft) Outer Diameter Liquid Pipe (inch) Outer Diameter Gas Pipe (inch) Max Height Distance (ft) Max Length Distance (ft) 1 Sound PRESSURE Level @ 3.3 ft. db(a) 2018 Ingersoll Rand All Rights Reserved M4MLW1818A / M4TLS1818A Cooling Heating 208 / 230 / 1 60Hz 17800 20000 3400-20475 - - 3400-21850 - 11600 6000 / 5275 / 1000 6400 / 5803 / 1000 1820 2090 8.1 8.5 18.0 9.2 850 / 750 / 650 / 500 3.8 9.9 2.78 M4MLW1818A1N0 1350 / 1200 / 1050 / 900 1300 / 1200 / 1100 / 900 0.37 Aluminum Fin-Copper Tube 0.286 2-0.055 28.0 1.0 12.0 2.5 3.15 57 / 54 / 51 / 45 47 / 44 / 41 / 35 38.2 x 11.8 x 8.8 41 x 15.1 x 12.6 30.9 / 37.5 M4TLS1818A11N Rotary RB68EB (POE Oil) 25 12.08 1440 EEV 0-115 -13-75 Aluminum Fin-Copper Tube 0.37 1-0.055 33.6 x 0.9 x 26 800 60 0.52 3200 20.5 Automatic Defrosting 67 57 37.6 x 27.6 x 15.6 40.5 x 18 x 29.5 97.0 / 106.9 45.9 16.0 25.0 0.22 1/4 1/2 66 98

Indoor Unit Dimensions, continued 18K-24K Indoor Units Unit Dimensions W D H 18K 4 27 7 3/16 Φ2 3/16 Φ2 3/16 1 1/2 7 1/2 5 1/2 8 1/8 27 7 5/16 24K Φ2 3/4 Φ2 3/4 6 3 1/8 1 11/16 The dimensions in these drawings are rounded according to standard measurement. Unit: inch Models W H D 18K 38 3/16 11 13/16 8 13/16 24K 42 7/16 12 13/16 9 11/16

Unit Dimensions Outdoor Unit Dimensions 18K-24K Outdoor Units 13 3/8 35 27 9/16 15 5/8 38 The dimensions in these drawings are rounded according to standard measurement. 14 5/16 Unit: inch 22

Clearance Requirements Space to the ceiling 6 in. or more Space to the wall 6 in. or more 6 in. or more Space to the wall 118 in. or more Air outlet side 66 in. or more Space to the floor The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures Space to the obstruction 12 in. or more Space to the wal l 9 7 n.or more i 20 in. or more Air inlet side 12 in. or more Space to the wall 20 in. or more Air outlet side valve cover NOTE: The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m). Air Velocity Patterns for High Wall Max Horizontal Distance Unit: ft. (m) Model Cooling Mode Heating Mode M4MLW1818A 30.2 (9.2) 21.3 (6.5)

Performance Data M4TLS1818A1/M4MLW1818A1 Cooling Mode Performance Data Outdoor Indoor Entering Air Temperature (Dry Bulb/Wet Bulb) Ambient Air Temperature 68/57 F 73/61 F 79/64 F 80/67 F ( F) TC* SHC** TC SHC TC SHC TC SHC 0 9000 6800 9500 7200 10500 7900 11600 8100 10 10700 8300 11300 8800 12300 9600 13300 10200 20 12200 9500 13000 10100 14300 11200 15000 11800 30 12900 10100 13800 10800 15400 12000 16000 12600 40 13500 10500 14400 11300 16100 12400 16800 13100 50 14100 11000 15100 11700 17200 13000 16500 12700 55 14700 11500 15800 12300 17300 13300 17500 13500 60 15500 12100 16600 13000 17700 13800 18400 14400 65 16700 13000 17800 13900 18600 14500 19400 15100 70 17300 13500 18400 14400 19200 15000 19900 15600 75 17200 13400 18300 14300 19000 14800 19800 15500 80 12400 13200 18000 14000 18800 14600 19600 15500 85 4400 12800 17500 13600 18600 14400 19200 15500 90 8400 12400 16600 13000 18100 14100 18700 15000 95 15400 12000 15700 12300 17600 13700 18200 14400 100 15000 11700 15300 11900 16800 13500 17500 13900 105 14500 11300 14900 11600 16100 13200 16900 13400 110 14100 11000 14600 11400 15400 12800 16200 12700 115 13700 10700 14300 11100 14800 12500 15500 12100 *Total Capacity **Sensible Heat Capacity M4TLS1818A1/M4MLW1818A1 Heating Mode Performance Data Outdoor Indoor Entering Air Temperature Ambient Air Temperature 68 F 73 F 80 F 82 F ( F) TC* TC TC TC 13 9800 9700 9200 9100 10 10400 10100 9800 9700 5 11000 10600 10400 10300 0 12000 11500 11300 11200 5 12500 12000 11800 11700 10 13100 12600 12300 12200 15 13400 12900 12600 12500 20 14000 13500 13200 13100 25 15300 14800 14500 14400 30 16400 15800 15500 15400 35 17400 16900 16600 16400 40 18500 17900 17600 17400 45 19900 19400 19000 18800 Capacities in these performance 50 20800 20200 19800 19600 tables reflect normal operation at 55 21100 20400 20000 19800 the temperatures indicated. See 60 21500 20800 20400 20200 specification tables for certified 65 21900 21200 20800 20600 values under prescribed test 70 22200 21500 21100 20900 conditions. 75 22500 21800 21400 21200 *Total Capacity

Mechanical Specifications Mini-Split Outdoor Unit General This unit is fully charged from the factory for up to 25 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for outdoor application. Unit Casing The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Refrigerant Controls The compressor motor and condenser fan motor are controlled and monitored by an integrated electronic module. Additionally, the same module monitors sensors to control refrigerant flow through the sealed system as well as air flow. Compressor The compressor features internal over temperature and pressure protection; total dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise. Condenser Coil The condensor coil is constructed from aluminum plate fins and copper tubing. The coil provides air flow resistance and efficient heat transfer. Low Ambient Operation Matched Ameristar ductless products, have cooling capabilities at outdoor ambient temperatures as low as 0 F and heating capabilities at outdoor ambient temperatures as low as -13 F. Mini-Split Indoor High Wall General The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an Ameristar outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed. Unit Casing Casing shall be provided with knockouts on the right, and left of the unit to facilitate piping and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electrical terminal strip. Discharge Airflow and Distribution System Unit shall have auto swing, dual horizontal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle. Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow. Controls Units shall have the capability to be controlled remotely through wall-mounted wired options (sold separately) as well as a wireless remote option. Remote Controller The unit shall have a wireless infrared remote controller with easy reading digital display panel to start, stop and regulate the air conditioner from a distance. The wireless controller is included with all units. Healthy Filters The unit shall have an active carbon and catechin filter with the unit.the filters need to be cleaned at least once a year. 01/18 The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.

M4MLW1824A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1824A1N0A M4TLS1824A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating Capacity (Btu/h): Minimum Cooling Capacity (@95F) (Btu/h): Maximum Cooling Capacity (@95F) (Btu/h): Minimum Heating Capacity (@47F) (Btu/h): Maximum Heating Capacity (@47F) (Btu/h): Maximum Heating Capacity (@17F) (Btu/h): Total Capacity (W) (High/Standard/Low): Rated Power Input (W) Nominal Input Current (A) SEER / HSPF Air Flow Volume (CFM) (H/M/L) Dehumidifying Volume (pt./h) EER (Btu/W hr)/cop Indoor Unit Fan Motor Speed (r/min) (SH/H/M/L) Fan Motor RLA(A) Evaporator Pipe Diameter (inch) Row Fin Gap (inch) Coil length (L) x depth (D) x coil width (W) (inch) Output of Swing Motor (W) Fuse (A) Sound Power Level db (A)(SH/H/M/L) Sound PRESSURE Level db (A)(SH/H/M/L) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (L/W/H) (inch) Net Weight /Gross Weight (lbs) Outdoor Unit Compressor Type Compressor Oil L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Throttling Method Working Temp Range ( F) Condenser Pipe Diameter (inch) Row Fin Gap (inch) Coil length (l) x depth (D) x coil width (W) (inch) Fan Motor Speed (rpm) Output of Fan Motor (W) Fan Motor RLA (A) Air Flow Volume of Outdoor Unit (CFM) Fan Diameter (inch) Defrosting Method Sound Power Level db (A) Sound PRESSURE Level db (A) 1 Uncrated Dimension (W/H/D) (inch) Crated Dimension of Package (W/L/H) (inch) Net Weight /Gross Weight (lbs) Refrigerant Charge (oz) MCA MOP Connection Pipe Refrigerant additional charge(oz/ft) Outer Diameter Liquid Pipe (inch) Outer Diameter Gas Pipe (inch) Max Height Distance (ft) Max Length Distance (ft) 1 Sound PRESSURE Level @ 3.3 ft. db(a) 2018 Ingersoll Rand All Rights Reserved M4MLW1824A / M4TLS1824A Cooling Heating 208 / 230 / 1 60Hz 22800 25000 8600-24000 - - 8600-26000 - 16000 7034 / 6450 / 2500 7600 / 7034 / 2500 2010 2130 8.92 9.45 18.4 10.5 1200 / 1050 / 900 / 750 4.2 11.0 3.3 M4MLW1824A1N0 1300 / 1150 / 1000 / 850 1300 / 1150 / 1000 / 850 0.32 Aluminum Fin-Copper Tube 0.286 2-0.059 33.25 x 1.0 x 13.5 2.5 3.15 63 / 59 / 56 / 52 49 / 46 / 42 / 36 42.4 x 12.8 x 9.7 45.2 x 16.3 x 13.8 37.5 / 45.2 M4TLS1824A11N Rotary RB68EB (POE Oil) 25.0 12.18 1440 EEV 0-115 -13-75 Aluminum Fin-Copper Tube 0.28 1-0.055 36.8 x 1.5 x 26 800 60 0.40 3200 20.5 Automatic Defrosting 68 58 37.6 x 27.6 x 15.6 40.5 x 18 x 29.5 103.6 / 113.5 56.4 16.0 25.0 0.54 1/4 5/8 66 100

Indoor Unit Dimensions, continued 18K-24K Indoor Units Unit Dimensions W D H 18K 4 27 7 3/16 Φ2 3/16 Φ2 3/16 1 1/2 7 1/2 5 1/2 8 1/8 27 7 5/16 24K Φ2 3/4 Φ2 3/4 6 3 1/8 1 11/16 The dimensions in these drawings are rounded according to standard measurement. Unit: inch Models W H D 18K 38 3/16 11 13/16 8 13/16 24K 42 7/16 12 13/16 9 11/16

Unit Dimensions Outdoor Unit Dimensions 18K-24K Outdoor Units 13 3/8 35 27 9/16 15 5/8 38 The dimensions in these drawings are rounded according to standard measurement. 14 5/16 Unit: inch 22

Clearance Requirements Space to the ceiling 6 in. or more Space to the wall 6 in. or more 6 in. or more Space to the wall 118 in. or more Air outlet side 66 in. or more Space to the floor The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures Space to the obstruction 12 in. or more Space to the wal l 9 7 n.or more i 20 in. or more Air inlet side 12 in. or more Space to the wall 20 in. or more Air outlet side valve cover NOTE: The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m). Air Velocity Patterns for High Wall Max Horizontal Distance Unit: ft. (m) Model Cooling Mode Heating Mode M4MLW1824A 31.2 (9.5) 23 (7)

Performance Data M4TLS1824A1/M4MLW1824A1 Cooling Mode Performance Data Outdoor Indoor Entering Air Temperature (Dry Bulb/Wet Bulb) Ambient Air Temperature 68/57 F 73/61 F 79/64 F 80/67 F ( F) TC* SHC** TC SHC TC SHC TC SHC 0 16400 12900 17500 13700 20000 15700 20400 16000 10 17400 13700 18500 14500 21000 16400 21700 17000 20 18100 14200 19300 15100 22000 17200 22900 18000 30 19100 15000 20500 16100 23300 18300 24500 19200 40 20400 16000 22000 17200 24600 19300 26300 20600 50 20400 16000 21900 17200 24300 19100 26200 20600 55 20400 16000 21800 17100 24000 18800 26100 20500 60 20400 16000 21800 17100 23800 18600 25900 20300 65 20500 16100 21800 17100 23500 18400 25400 19900 70 20400 16000 21700 17000 23200 18200 24900 19600 75 19900 15600 21200 16600 23000 18000 24600 19300 80 19600 15400 20800 16300 22700 17800 24400 19100 85 19300 15200 20600 16200 22500 17600 24100 18900 90 19100 14900 20400 16000 22200 17400 24000 18800 95 18800 14700 20100 15800 22000 17300 24000 18800 100 18400 14400 19700 15500 21800 17100 23700 18600 105 18100 14200 19400 15200 21700 17000 23400 18300 110 17800 14000 19100 15000 21400 16800 23100 18100 115 17500 13800 18900 14800 21100 16600 22800 17900 *Total Capacity **Sensible Heat Capacity M4TLS1824A1/M4MLW1824A1 Heating Mode Performance Data Outdoor Indoor Entering Air Temperature Ambient Air Temperature 68 F 73 F 80 F 82 F ( F) TC* TC TC TC 13 14100 13900 13600 13300 10 15000 14700 14500 14100 5 15900 15600 15300 15000 0 17400 17100 16800 16400 5 18200 17900 17600 17200 10 19100 18800 18400 18000 15 19600 19300 18900 18500 20 20300 20000 19600 19200 25 21400 21100 20700 20300 30 21800 21500 21100 20700 35 22100 21800 21500 21100 40 22500 22200 21900 21500 45 23700 23400 23000 22500 50 24400 23900 23500 22900 Capacities in these performance 55 24700 24200 23800 23200 tables reflect normal operation 60 25100 24700 24200 23600 at the temperatures indicated. 65 25700 25200 24700 24100 See specification tables for certified values under prescribed test 70 26100 25600 25100 24500 75 26400 26000 25400 24800 conditions. *Total Capacity

Mechanical Specifications Mini-Split Outdoor Unit General This unit is fully charged from the factory for up to 25 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities with the mini-split air handler shown in the catalog are AHRI certified. The unit is ETL listed for outdoor application. Unit Casing The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Refrigerant Controls The compressor motor and condenser fan motor are controlled and monitored by an integrated electronic module. Additionally, the same module monitors sensors to control refrigerant flow through the sealed system as well as air flow. Compressor The compressor features internal over temperature and pressure protection; total dipped hermetic motor windings. Other features include: centrifugal oil pump and low vibration and noise. Condenser Coil The condensor coil is constructed from aluminum plate fins and copper tubing. The coil provides air flow resistance and efficient heat transfer. Low Ambient Operation Matched Ameristar ductless products, have cooling capabilities at outdoor ambient temperatures as low as 0 F and heating capabilities at outdoor ambient temperatures as low as -13 F. Mini-Split Indoor High Wall General The High Wall mounted type air handler shall be completely factory assembled including coil, condensate drain pan, fan motor, washable filter, air purifying filter and electric controls to be used with a wireless remote controller. Unit shall be shipped with a unit mounting plate. Unit shall be matched with an Ameristar outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed. Unit Casing Casing shall be provided with knockouts on the right, and left of the unit to facilitate piping and electrical connection on either side of the unit. An electrical service cover shall be provided to permit easy access to the electrical terminal strip. Discharge Airflow and Distribution System Unit shall have auto swing, dual horizontal blades to optimize the aperture outlet for vertical airflow and air distribution. Blade shall close automatically when the air conditioner is turned off to minimize dust entering the unit. Five-Step preset program on the remote controller shall be available to control the blade angle. Manually adjusted wide-angle louvers shall be provided to adjust the coverage and direction of airflow. Controls Units shall have the capability to be controlled remotely through wall-mounted wired options (sold separately) as well as a wireless remote option. Remote Controller The unit shall have a wireless infrared remote controller with easy reading digital display panel to start, stop and regulate the air conditioner from a distance. The wireless controller is included with all units. Healthy Filters The unit shall have an active carbon and catechin filter with the unit.the filters need to be cleaned at least once a year. 01/18 The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.