BULLETIN. Permitting Tips (11/10)

Similar documents
FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

Commercial Rules and Regulations

Bold items are particular to the City of Euless

Commercial Remodel/ Add On Rules and Regulations

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

FIRE & LIFE SAFTEY STANDARD

Fire Alarm, Water Flow Alarm & Signaling Systems

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Fire Sprinkler Submittal Requirements and Acceptance Testing

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Fire Inspection Frequently Asked Questions

Site Address: Bldg./Suite #: Departments Phone Date Approval Signature A) Planning COMMENTS:

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

SAWGRASS MILLS BULLETIN

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Department of Planning & Community Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

HIGH-RISE RETROFIT ORDINANCES - NO and NO

BULLETIN. Temperature Controls (VAV) (3/11/2010)

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

September 30, Dear Fire Suppression System Contractor/Designer:

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Tenant Heat Pump Bulletin Temperature Controls Buildings A1, C1, and H1

2.11 Submittal Guidelines for Emergency Evacuation Signs (2016)

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

City of Boynton Beach Building Division

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Large Family Daycare Guideline

ADDENDUM NO. 3 March 19, 2018

BULLETIN. Temperature Controls (10/2013)

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

AUTOMATIC FIRE SPRINKLER SYSTEMS

The following information shall become and form part of the contract documents.

DONALD H. BERG, ARCHITECT

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

New School Construction: Safe School Opening. OAR and IOR Joint Training February 17, 2005

Fire Sprinkler Plan Submittal Form

a) Establishment of emergency procedures to be followed at the time of an emergency;

You are required to READ ALL PAGES. of this application

Electronic Safety and Security

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

WEST VIRGINIA UNIVERSITY

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

Fire Prevention Coffee Break Training. February 2017

CITY OF PASADENA FIRE DEPARTMENT

Medical Gas and Vacuum Systems

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

CITY OF LOS BANOS LANDSCAPE PLAN REVIEW PROCEDURE. Public Works Department 411 Madison Avenue, Los Banos, CA FOR ALL PROJECTS:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

BULLETIN. Temperature Controls (Chilled Water) Phase III only (3/11/2010)

FIRE ALARM PLAN REVIEW PERMIT REQUIREMENTS

For additional information regarding R-3.1 residential care facilities please contact (951)

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

TOWNSHIP OF WEST WINDSOR 271 CLARKSVILLE ROAD, P.O. BOX 38 WEST WINDSOR, NJ (609) FAX (609)

Brighton Area Fire Authority

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

FIRE ALARM SYSTEMS INFORMATION PACKET. Des Moines Fire Department Fire Prevention Bureau

Design & Construction Standards, Revised January

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

FIRE AND SAFETY PROJECT REVIEW REPORT

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

FIRE SUPPRESSION SPRINKLER SYSTEM

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

Web Pages for Construction and Traveler Information Condition Reporting System 511 Phone Power. Data Processing and Response Formulation

LOS ANGELES UNIFIED SCHOOL DISTRICT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY PROCEDURE

Design & Construction Standards, Revised January

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

The Owner will provide the QEI inspection and certification services.

Residential Care Facilities Requirements

SECTION WET-PIPE SPRINKLER SYSTEMS

Commercial Application/Plan Review Submittal Checklist

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Community Development Department Commercial Permit Application

New Construction Fire Inspection Process

Title: Fire Sprinkler System Permit Requirements

(3) Chart. The following chart illustrates the above hours: TABLE INSET:

Residential-based Care Facility R-4 Guideline

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

City of Attleboro, Massachusetts WATER DEPARTMENT Government Center, 77 Park Street Attleboro, Massachusetts Phone Fax

Winnipeg Fire Department Fire Prevention Branch

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

Fire Prevention Coffee Break Training. February 2016

CITY OF DANIA BEACH Local Business Tax Receipt Division 100 W Dania Beach Blvd. Dania Beach, FL Phone: ext 3644 / Fax

McMAHON FP200 OUTAGAMIE COUNTY ADMINISTRATION CENTER S. WALNUT & W. 8TH, APPLETON, WI ALTERATION / ADDITION

GARCIA GALUSKA DESOUSA Consulting Engineers

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

APPLICATION CERTIFICATE OF OCCUPANCY $50.00 FEE (non-refundable)

Note: An OFM occupancy load permit is required prior to receiving a special event license through the Liquor Licensing Board.

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

Transcription:

BULLETIN Permitting Tips (11/10) This bulletin is to make you aware of issues that have been identified by the City or other retailers and suggests Tenant s architect and engineer pursue further as it relates to Tenant s contract documents. Plans will need to be sent to both the Indiana Plan Review Branch of the Division of Fire and Building Safety and to the City of Noblesville in order to obtain a building permit. The City of Noblesville will not issue a permit until the State of Indiana does. You can submit to all agencies at the same time. Landlord approval IS NOT required to submit for a construction permit. The State of Indiana must issue a Construction Design Release (CDR) prior to the Noblesville Department of Planning and Development issuing the permit. Any changes made to the plans after CDR approval must be resubmitted to the state as an addendum and also submitted to the city. The city will not release the revised plans without the approved addendum from the state. Tenant plans must be kept current with construction. Failure to resubmit revisions will cause issue with inspectors, and Tenant will experience failed inspections. The State will automatically notify the City of Noblesville that they have approved your plans and can release your permit. The City of Noblesville will not release the permit until: 1. Received State CDR approval. 2. Received Health Department approval, if required. 3. All fees are paid. State of Indiana Review The web site contains detailed information on the following: 1. Contact Information 2. Electronic Filing Information 3. Downloadable Applications 4. Frequently Asked Questions 5. Project Activity (Includes real time plan submissions and releases) Web site: http://www.in.gov/dhs/fire/branches/plan_review/

City of Noblesville Review Submit plans to the Noblesville Department of Planning and Development to obtain the permit. Every sheet must be signed and wet sealed by an Architect and Engineer licensed in Indiana. Submit a copy of the State Release. A key plan highlighting the exact location of the space within the development is acceptable for site plan submittal. A Letter of Commencement, on Tenant s corporate letterhead, signed by the Tenant s representative with the following specific use information outlined in the letter: Information requested must include number of employees, number of seats (restaurant), number of clients (health club or spa uses), etc. Use information shall be consistent with IDEM 327 Table 11-1. If the applicant is unclear as to the required information, contact Brian Gray, Department of Engineering (317-776-6330 or bgray@noblesville.in.us) Each plan review cycle, if re-submittal is required, is approximately 7 10 days. Comments from each review will be faxed back to the person that submitted the plans. Fire Department reviews plans submitted to the building department. A separate submittal is not required. Sprinkler shop drawings are not required for submittal, but must be submitted prior to first inspection. General contractor s information and signature required on application. For more detailed information visit the web site or contact: Noblesville Department of Planning and Development 16 S. 10 th Street, City Hall Noblesville, Indiana 46060 317-776-6325 http://www.cityofnoblesville.org/planning Note: All applications/ forms are available on line IF APPLICABLE: Health Department submittal is separate from the city submittal. You can submit to the Health Department at the same time you submit to the city; however, the city will not release the building permit without approval from the health department. For more detailed information contact: Hamilton County Health Department 317-776-8500 Separate Sign Permit application needs to be filled out. This takes 5-7 days for review. Paperwork needed is outlined on City of Noblesville website. Landlord stamped approved sign drawings are required prior to submission to the city. Grease interceptors The city of Noblesville will only allow grease traps outside the space. The city requires a 1000 gallon minimum trap. They test them annually. Refer to the City s website to obtain the Grease Interceptor Sizing Worksheet.

Duct Detectors Per the Fire Marshall with the City of Noblesville, remote duct detector test switches are required for all required duct detector installation. The test switches can be grouped together in one location and/or mounted in a drop ceiling. All installations must conform to the manufacturer s recommendations. Additionally, upon activation, the duct detectors are required to shut down the affected HVAC unit and send an audible and visible signal in a normally occupied area within the tenant space (i9f a fire alarm system is NOT present). If a fire alarm system is present, the duct detector shall send a supervisory signal to the fire alarm panel per the Hamilton Town Center Fire Alarm Matrix. If the Test button assemblies also house the audible and visible functions, then the test switch locations will have to be installed in a normally occupied area. For additional information, please contact the Fire Marshall. Firestop Sealant All Tenant Contractors are required to use the attached Firestop sealant by Hilti. This system is existing throughout the project and will need to be used to ensure a U.L. rated wall assembly project wide. Please keep an empty tube on the job site and the cut sheets for the Building Inspectors.

Exterior emergency lighting is required at all exit doors. See specifications below: The Noblesville s building department is requiring an emergency egress light fixture be placed above the storefront entrance doors. The tenant is to furnish and install the fixture which must be tied into your existing emergency lighting system. Attached are the Type E2 and Type E3 lighting fixture cut sheets for the emergency egress lighting. Type E2 is to be used on storefronts that do not have a canopy. Type E3 is to be used where a canopy occurs. Type Mnfr Catalogue # Lamping E2 Lithonia AFN-volt-finish-ext xenon lamping by mnfr Note: Finish: Tenant can pick the color that goes with their storefront. Standard colors are: W-White; B-Black; BN-Brushed nickel; BD-Dark bronze. E3 (fixture) Winona PE-14-12V-LO-IVS-FO-SHO-C1 1-35MRC16/FL36 E3 (battery pack) Lithonia ELM 1272-RT-RO Note: Finish: Ivory. The remote battery pack for the Type E3 fixture should be located in an adjacent accessible ceiling within the tenant space. The Type E2 and E3 fixtures will be normally off/emergency fixtures. The tenant s electrical engineer is to verify quantity and locations as required. Tenant or tenant s GC may contact Aaron McNeal at Kirby-Risk, (317) 687-0015 to purchase these fixtures.