REC-8R Environmental Control. Operation and Installation Manual

Similar documents
Poultry House Control

Element. Controller. Manual for use and maintenance. Element. Climate Controller. Ag/MIS/UMGB /17 Rev 1.0 P/N:

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1.

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

ELECTRONIC COMMUNICATING THERMOSTAT

Platinum Touch/Rotem One Touch

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

ETN-24-SUPER-PROG (US Program - Celsius)

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

EXPERT TRI-STAR. Temperature controller. User s Manual

SAFETY INFORMATION AND WARNINGS

Smart Temp. Model

ELITE-600 DENTAL PORCELAN FURNACE

ECS-2M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Product Manual SZ1009

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Product Manual SZ1022/SZ1031/SZ1035/

PARAGON Commercial Refrigeration Controls

Electronic Pellet Burner Controller NPBC-V3M

Product Manual SZ1144

PTE0705 Electric Fence Monitor

Model: Touch-RS. 1 Touch-RS

Product Manual SZ1145

MULTI-STAGE CHILLER CONTROL

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Electronic Pellet Burner Controller NPBC-V3-1

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Installation Instructions & User Manual

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Carbon Monoxide Transmitter

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

CLEANROOM MONITOR CR3A Network - Installation Instructions

Model: PRT-TS / PRT-NTS

Dryer Controller M720

PRT-TS WiFi PRT-TS WiFi

ECS 5M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

USER MANUAL FOR OPERATING SYSTEM

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Duct and Rough Service Carbon Monoxide Sensor

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

HOG CONTROLLER SYSTEM

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

STORM PRO Model # - C-4014, C Storm Pro- Instruction Manual V.2. This instruction manual serves as a guide for the Storm Pro.

B-40/B-41 Modulating Temperature Controller

Model: Edge-HC. 1 edge-hc

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

XWA11V. Walk-In Temp / Door /Alarm / Light Module

User Manual. Dryer Controller M720

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Please read this manual carefully before installation and use.

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional

RCS Residential Control Systems Inc.

User manual and installation guide

Mark 25 Ultrapure Water Conductivity Analyzer

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Oakton TEMP 9500 Advanced Multiparameter Controller

: PRT / PRT PRT / PRT-N1

PL-1 Thermostat User s Guide

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Model: Touch-RF. 1 Wireless Series

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

ETN-24-SUPER-SF Series

OWNER S MANUAL Venstar Inc. 08/07

FPC-02 Series. Installation and Operating manual

Installation, Start-Up, and Operating Instructions

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

Operator: Save these instructions for future use!

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

EasyTronic III MANUAL SERVICE

Model: Available in: Sapphire Black and Glacier White. 1 Series

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

ECC-1 user manual and installation guide

CONTROLS INSTRUCTIONS MANUAL ENGLISH

M770 ph Controller Owner s Manual

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

Ammonia Leak Detector Manual

UNC100 Integra Manual

Automatic Lamp & Mat Heating Control

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

INSTALLATION AND OPERATION MANUAL

Transcription:

REC-8R Environmental Control Operation and Installation Manual

This manual is published by Rotem Computerized Controllers Ltd. All rights to this publication are reserved. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means. Rotem Computerized Controllers Ltd. reserves the right to make changes or improvements to the equipment, software, and documentation herein described at any time without notice. Copyright 1996 by Rotem Computerized Controllers Ltd. Warning: Rotem products are designed and manufactured to provide reliable operation. Strict tests and quality control procedures are applied to every product. However, there is the possibility that something may fail beyond our control. Since these products are designed to operate climate control and other systems in confined livestock environments, where failure may cause severe damage, the user should provide adequate back up and alarm systems. These are to operate critical systems even in case of a Rotem system failure. Neglecting to provide such back up will be regarded as the user s willingness to accept the risk of loss, injury and financial damage. Rotem Computerized Controllers Ltd. 23 Efal St, Kiriat Arie Petach-Tikva 49511, Israel Tel: 972-3-920-6200 Fax: 972-3-924-9834 E-mail: rotem@rotem.com web site: www.rotem.com 28/12/2003 Rev:1.2 Page 2

FEATURES... 4 BASIC OPERATING PRINCIPLES... 4 OPERATION SUMMARY... 5 DISPLAY, EDIT FRONT PANEL ITEM... 5 VIEW OR SET CLOCK... 5 VIEW OR SET GROWTH DAY... 5 CALIBRATE SENSORS AND CLEAR FAILED SENSOR ALARM... 6 VIEW OR EDIT SYSTEM VARIABLES... 6 CLEAR ALARM RELAY... 6 TARGET TEMPERATURE SETTING... 7 AUTOMATIC TEMPERATURE ADJUSTMENT... 7 DETAILED DESCRIPTION OF OUTPUTS... 8 PROCEDURE TO ADJUST OUTPUT PARAMETERS... 8 HEATER 1 AND 2 OUTPUTS:... 8 Target Temperature, Heater Differential and Hysteresis... 9 FAN 1, 2, 3, 4, 5, 6, 7... 9 Fresh Air/Humidity Treatment... 9 COOLING... 9 ALARM... 9 Clearing Alarms... 9 CALIBRATION PROCEDURE... 9 MANUAL OPERATION... 9 SYSTEM VARIABLES... 9 CHECKING CURRENT VERSION OF SOFTWARE... 9 FACTORY DEFAULT SETTINGS... 9 INSTALLATION... 9 SPECIFICATIONS... 9 28/12/2003 Rev:1.3 Page 3

Features Multiple Stainless Steel Temperature Sensors Optional Humidity Sensor Four Digit Display Easy to Use Operator Control Panel with Four Digit Display Water and Dust Tight Enclosure Special Programs such as Fresh Air Treatment Basic Operating Principles The Environment Control REC-8R measures inside and outside temperatures with one or two inside-the-barn temperature sensors. It also uses an optional inside humidity sensor and outside temperature sensor. By activating fans, heaters and cooling systems, it brings the conditions inside the barn to pre-set parameters. These are target temperature and requested humidity. Target temperature is the most important parameter. It is a set point determined by you, the user. Heaters, fans, cooling system and alarm are set as independent differentials above or below target temperature. When you change the target temperature, the REC-8R automatically adjusts the other levels. Since the differentials are independent, you can use the outputs in various ways, as explained later. Requested humidity and the optional humidity sensor are important for three main reasons: 1. If the humidity is exceptionally high, the REC-8R will keep the cooling system off. Foggers, misters and cooling pads are not effective in extremely high humidity. 2. If the humidity is high, the REC-8R will periodically increase the ventilation level to bring in fresh air. The fresh outside air will be drier than the inside air due to transpiration by the birds. Cooler outside air dries out when it warms to inside temperatures, reducing humidity. 3. Ammonia levels correlate with humidity levels. When the REC-8R adjusts ventilation for humidity, it is also improving the ammonia condition. 28/12/2003 Rev:1.2 Page 4

Operation Summary 1 Display, Edit Front Panel Item Press Select repeatedly until the LED indicator beside the desired item illuminates. Note that you cannot edit sensor values, such as temperature or humidity readings, except with the calibration procedure. The LED indicator for items you can edit, such as target temperature, will flash. The standard display of Inside Temperature returns after a short while. To extend the viewing period, press one of the arrow keys. To edit, press the Program key. Then, use UP or DOWN arrow keys. Press Select to continue. 3 View or Set Clock Select standard display (Inside Temperature). Press and hold UP arrow key. While holding UP arrow key, press Program key. To set clock, press Program key again, or Select to continue with other items.. Use UP and DOWN arrow keys to change hours. Press Select, then UP and DOWN arrow keys to change minutes. 4 View or Set Growth Day Select standard display (Inside Temperature). Press and hold DOWN arrow key. While holding DOWN arrow key, press Program key. To change growth day, press Program key again. Use UP and DOWN arrow keys to change the growth day. 28/12/2003 Rev:1.3 Page 5

5 Calibrate Sensors And Clear Failed Sensor Alarm Select standard display (Inside Temperature). Press and hold UP arrow key. While holding UP arrow key, press and hold Select key. Sensor 1 appears in display. To edit or clear a sensor 1 alarm, press the Program key. Use the UP and DOWN arrow keys to set the sensor to the correct reading. Press Select to continue. 6 View or Edit System Variables Select standard display (Inside Temperature). Press and hold Both arrow keys for about 2 or 3 seconds. System Variable A appears in display. Warning: Refer to your manual and review the meaning and use of each system variable, before changing it. Press Program to change it, then use the UP and DOWN arrow keys. Press Select to continue with the next system variable. 7 Clear Alarm Relay If a serious alarm occurs, the REC-8R activates the alarm relay, which generally turns on an alarm siren or bell. The alarm siren or bell may be distracting if you are working on the problem. Simply press the Select key to turn off the alarm relay. The alarm will still flash in the display. If a new alarm occurs, the relay will activate again. 28/12/2003 Rev:1.2 Page 6

Target Temperature Setting The REC-8R has an automatic temperature adjustment feature. This permits you to set the target temperatures for the entire flock growth period, and let the REC-8R adjust the temperatures for you each day. Figure 1 Temperature 36 First Day = 5 34.0ºC 34 32 24 Last Day = 21 21.0ºC 22 20 1 2 3 4 5 18 19 20 21 22 23 24 Growth Day Automatic Temperature Adjustment As shown in Figure 1, Target Temperature is constant up to the first day of automatic temperature adjustment. The REC-8R then automatically adjusts the temperature each day up to the last day of automatic adjustment. In Figure 1, the first day is 5 (F.dAY = 5), and target temperature is 34.0ºC. As long as the growth day is less than or equal to five, the REC-8R keeps a target temperature of 34.0ºC. Last day is set to 21 (L.dAY = 21) with target temperature at 21.0ºC. From growth day 21 and on the target temperature will be 21.0ºC. (These numbers are an example only; your settings may be different.) 28/12/2003 Rev:1.3 Page 7

Detailed Description of Outputs Each of the eight outputs has a corresponding indicator in the row at the top of the control. The REC-8R turns these on whenever the output is active. In order to set parameters for each output, first follow the Procedure to Adjust Output Parameters. Refer to the individual sections on each particular output for further details. Procedure to Adjust Output Parameters 1. Press and hold the Select key until the heater indicator (top left in the form of a flame) blinks. 2. Repeatedly press the Select key until the indicator for the output you wish to adjust blinks. If you pass it, you will need to start again. 3. Press the Program key. The first parameter will flash alternately with its name. Use the Up Arrow and Down Arrow keys to edit the value. 4. If there are more parameters, you must press the Program key to access them. Once you have pressed the Program key, the Select key will advance through all the parameters for this output, before going on to the next output. 5. Press the Select key to go to the next parameter or output. After the last output, or last parameter of the Alarm output, pressing on the Select key returns you to the standard display. 6. If you forget to finish editing with the Select key, the REC-8R automatically returns to the standard display after a short delay. Heater 1 and 2 Outputs: The heater outputs operate at a differential below target temperature. This automatically adjusts the heater set point. Besides the differential, you may adjust the hysteresis level for the heater output. Finally, you may choose to have the variable speed fan stop, or allow it to run at the minimum setting, when the heaters are on. The following diagram illustrates the relationship between target temperature, differential, and hysteresis for the heater output. The other outputs have similar parameters. The Sens option is to determine which sensors will activate heater 1 and which will activate heater 2. The Sens appears after Diff in Heaters (Press Prog. to enter the Heaters and Select to switch to sens. The options are 1,2,3 for a certain sensor or 12,13,23,123 for an average between the chosen sensors (12 is the average between sensor 1 and 2 etc.) Default: 1 for heater 1 and 2 for heater 2. 28/12/2003 Rev:1.2 Page 8

Figure 2 26.5ºC Heater Automatic Set Point -1.5ºC Heater Differential 25ºC 30ºF 25.8 27.2 0.7ºC Hysteresis 28.0ºC Target Temperature Target Temperature, Heater Differential and Hysteresis For this example the target temperature is at 28.0ºC. The heater differential is -1.5ºC, which places the heater set point automatically at 26.5ºC. The grower set the heater hysteresis (system variable C) at 0.7ºC. The hysteresis level is a second type of differential about the heater set point. The heater first turns on at the lower hysteresis point or 25.8ºC, then stays on until the temperature climbs to the upper hysteresis point or 27.2ºC. Between these points the heater can be on or off, depending on the REC-8R. Below the lower hysteresis point the heater must be on, above the upper point the heater must be off. Fan 1, 2, 3, 4, 5, 6, 7 The fan 1 and 2 output is for ON/OFF cycle. The various settings, including the ON/OFF duty cycle settings for fan 1 and 2 are under the Fan icons on the front panel of the REC-8R. In case that ON=0 and OFF=0 the fans will operate as regular fan without the ON/OFF cycles (like fans 3,4 and 5). Fans 3, 4,5,6,7 do not have duty cycle parameters. However, Fan 5 is under the alarm icon if you have selected the fan option in lieu of the alarm option as explained in system parameters below. Fan 6 is under the Heater 1 icon if you have selected the fan option in lieu of the Heater 1 option as explained in system parameters below. Fan 7 is under the Heater 2 icon if you have selected the fan option in lieu of the Heater 1 option as explained in system parameters below. 28/12/2003 Rev:1.3 Page 9

If system parameter J = 1 than the controller will operate only one fan at a time. This mode is suitable for autotransformer used. The Sens option is to determine which sensors will activate Fan 1 and the rest of the fans and the Cooling will operate accordingly. The Sens appears after Diff in Fans (Press Prog. to enter Fans and select to switch to Sens The options are 1,2,3 for a certain sensor or 12,13, 23,123 for an average between the chosen sensors. Default: 12 Figure 3, Fan 1 and 2 Operation Fan on ON/OFF Duty Cycle Fan ON Full Duty 2.0ºC Diff 24 25 26 27 Target Temp 28 29 30 31 32 Fresh Air/Humidity Treatment The Fresh Air/Humidity Treatment feature turns on one additional fan, unless all the fans are running for a programmable amount of time. It performs this function whenever the humidity is higher than the target humidity for more than a preset time. Program these items in the system variable section. The humidity treatment is operating down to Heater 1 temperature even if Fan 6 is using instead of Heater 1. Note: If there is no humidity sensor in use than it s possible to have fresh air treatment by changing the requested humidity to 0. This will turns on one additional fan for a programmable amount of time (programmed by hidden parameters E and F. (The default is every 5 minute to 1 minute ) 28/12/2003 Rev:1.2 Page 10

Cooling The cool output has an independent differential with respect to target temperature, a cycle timer and a relative humidity setting. If the humidity level is above the relative humidity setting, the cooling system will not operate. Time 5 On 1 Off 9 12 Diff. 1 Diff. 2 Diff. Non-Active Cooling is now dynamic and has 2 diffs and 2 on/off times. Below dif 1 the cooling does not operate. From dif 1 to dif 2 the cooling will operate according to a curve. Above dif 2 will operate according to dif 2. Minimum on and off time is 0.1minute (6 sec.) if operation is in cycle. Dif 1 will always be smaller then dif 2. Default: Diff 1-9.0 On 1-1.0 Off 1-5.0 Diff 2-12.0 On 2-5.0 Off 2-1.0 Rh - 85 Example: Target is 70 and the temperature is 90. The On time will be 2:20min. and the Off time 3:20min. according to the curve. 28/12/2003 Rev:1.3 Page 11

Alarm The alarm output has two differentials, one for low temperatures and one for high temperatures. If the measured temperature goes below the low differential, or above the high differential from set point, the alarm output activates. The alarm output also activates if power fails, or if both temperature sensor 1 and sensor 2 fail. The display, however, flashes under any failure condition. Refer to the following alarm table. Alarm Table Condition Alarm Relay Display Power Failure Active Off High or Low Temperature Alarm Active Flashing Both Sensor 1 and 2 Failed Active Flashing One or more Sensors bad, but at least one of Sensor 1 or 2 Good Inactive Flashing All normal Inactive Steady Clearing Alarms 1. To clear only the alarm relay for an active alarm, press the Select key. The alarm relay will inactivate, but the display will continue to flash. If a new major alarm occurs, the alarm relay will activate again. This feature enables you to work on the problem without distraction by loud alarm sirens or bells. 2. To turn off the flashing display for a failed or removed sensor, use the calibration procedure. When you press the Program key at step 4 of the calibration procedure, the REC-8R will remove the sensor from the alarm list. You do not need to use the arrow keys to adjust the value in this case; simply leave the value at zero. 28/12/2003 Rev:1.2 Page 12

Calibration Procedure 1. Start with the display on Inside Temperature. Press the Select key repeatedly if needed until inside temperature is in the display. 2. Press and hold the up arrow key, then also press and hold the Select key until the Sensor 1 temperature reading blinks alternately with -1- in the display. This requires holding both keys for about 2 seconds. (Note, that if your finger slips off the up arrow key, the heater icon in the top row will begin to blink. If this happens, simply press Select several times until no icons are blinking in the top row and start again.) 3. Repeatedly press Select until the sensor you wish to calibrate appears in the display. The temperature sensors are numbered 1, 2 and 3. The humidity sensor is labeled rh. 4. Press the Program key. Prog appears momentarily in the display. Use the arrow keys to adjust the value to the correct value. Ensure you have used an accurate sensor for your calibration standard, and that it is at the same temperature or relative humidity as the sensor to be calibrated. Manual Operation 1. To operate any output manually, set system variable I to a value other than 0. Any value from 1 to 98 automatically sets a safety timer of ten minutes, after which the REC-8R returns to automatic operation. If you set variable I to 99, then the REC-8R remains in manual operation until you change variable I. 2. Press and hold Select until the heater 1 icon blinks. Press Select repeatedly until you reach the output you wish to control manually. 3. Press PROG, and then the UP and DOWN arrow keys to turn the output on and off. 28/12/2003 Rev:1.3 Page 13

System Variables System Variable Table Variable Default Description Value C.F Fahrenheit 0 => Celsius, 1 => Fahrenheit F.HyS 1ºF, 0.5ºC Fan Hysteresis H.Hys 1ºF, 0.5ºC Heater Hysteresis rh.hy 2% Humidity Hysteresis rh.on 1.0 Minutes Humidity Treatment Duration rh.dl 5.0 Minutes Humidity Treatment Delay AL.F5 ALr (alarm) Relay 8 Setting: ALr - Alarm FAn5 Fan 5 t.dly 2 Sec Stage Autotransformer Delay while parameter F.OP=1 r.op 0 (Auto) Auto/Manual Relay Operation 0 Auto, 1 Manual for 10 minute F.OP 0 (Normal) Fans Operation Mode 0-Normal 1- Suitable for Autotransformer. H1.F6 HEA1 (Heater 1) Relay 1 Setting: HEA1 - Heater 1 Fan6 - Fan 6 H2.F7 HEA2 (Heater 2) Relay 2 Setting: HEA2 - Heater 2 Fan7 - Fan 7 HOUS 0 House number baud 9600 Communication Baud rate PASS 0 Passward HIS 1 (Hour) Data logging interval time. (1,2,3,4,6,8,12,24 Hours) Checking current version of Software In order to check what is the current version of software installed, press Program and Select simultaneously, while the unit displays the inside temperature. The display will show the version with 3 or 4 digit, for example 297 is version February 1997. To return to the main display, press Select again. 28/12/2003 Rev:1.2 Page 14

Communication In order to communicate via a remote P.C., using Windows environment RotemNet communication software (3.11, windows 95,98,2000), do the following: 1. Install the Rotem-Net Communication Program under windows. 2. Connect the REC-8R Communication port to the PC with supplied cables according to one of the two following options: a. If the REC-8R controller is situated at less then 8 meters from the PC, than you can connect the REC-8R directly to the P.C. (to the RS232 serial port free COM) and set the jumpers on the controller power board, to DIR. b. If the REC-8R controller is situated at more then 8 meters from the PC, you need to use Rotem Mux-2 box for communication. The MUX-2 should be installed near the P.C. and the REC-8R jumpers should be set to MUX. 3. After having set all the hardware connections, please enter the house communication number (HOUS), and the baud rate (baud) and start the communication software and set the same baud rate in the local setting. Factory Default Settings To restore factory default settings perform a cold start : 1. Remove power from the REC-8R. 2. Press and hold the Select key and both Arrow keys. 3. While holding the three keys, restore power. 4. The REC-8R will restore the following settings. 28/12/2003 Rev:1.3 Page 15

Factory Settings Item Value Target Temperature 80ºF, 26.6ºC Requested Humidity 55% Growth Day 1 Time no change Heater 1 Differential -1.0ºF, -0.5ºC Heater 2 Differential -4.0ºF, -2.0ºC Fan 1 Differential 0.0ºF, 0.0ºC Fan 1 ON Time 1.0 Minutes Fan 1 OFF Timer 1.0 Minutes Fan 2 Differential 3.0ºF, 1.6ºC Fan 2 ON Time 0 Minutes Fan 2 OFF Timer 0 Minutes Fan 3 differential 4.0ºF, 2.2ºC Fan 4 Differential 5.0ºF, 2.7ºC Fan 5 Differential 6.0ºF, 3.3ºC Fan 6 Differential 7.0ºF, 3.9ºC Fan 7 Differential 8.0ºF, 4.4ºC Cooling Differential 9.0ºF, 5.0ºC Cooling ON Time 1.0 Minutes Cooling OFF Time 5.0 Minutes Humidity Limit for Cooling 85% Alarm High Differential 7.0ºF, 3.0ºC Alarm Low Differential -5.0ºF, -2.0ºC System Variable A 1 System Variable B 1.0ºF, 0.5ºC System Variable C 1.0ºF, 0.5ºC System Variable D 2.0% System Variable E 1.0 Minutes System Variable F 5.0 Minutes System Variables G through n 0 28/12/2003 Rev:1.2 Page 16

Installation An authorized electrician must install the REC-8R. Power must be disconnected to avoid electrical shock and damage. To avoid exposing the REC-8R to harmful gases or high humidity, it is recommended to install it in the service room. Installation Category (Over voltage Category) III 5 Amps should protect the power supply to the controller Circuit breaker 1. Open the enclosure lid by unfastening the two screws to the left-hand side in the front. 2. Mount the REC-8R on the wall, using the 4 supplied screws through the mounting holes. (FIG 2) 3. Place the required cables through the cable holders at the bottom of the unit. Connect the wires according to the wiring diagrams: 3.1. Fig. 3 for Single-phase 110 volt fans, USA and Canada Only. 3.2. Fig. 4 for Two-phase 230 volt fans, USA and Canada Only. 3.3. Fig. 5 for Single-phase 240 volt fans, outside the USA and Canada. 4. To connect temperature and humidity sensors use shielded two or four conductor #18-#24 gauges cable. Connect the shields to the Ground terminal. Do not connect the shields at more than one point, or you may induce ground loop currents. Connect the red power supply wire of the humidity sensor to the VC terminal on the COMMUNICATION terminal block. 5. Close the REC-8R enclosure lid carefully and tightly. Use RTV silicon or equivalent sealant to seal the cable holders. 6. After installation is completed, operate the REC-8R for a few hours and re- check for proper operation. 28/12/2003 Rev:1.3 Page 17

Specifications Input Voltage Supply: Single-phase 110 VAC (USA & CANADA). Two phase 230 VAC (USA & CANADA). Single phase 240 VAC (Outside the US & CANADA). 0.315 Amp, 50-60 Hz Heaters, Fans, and Cooling: 5 Amp. Normally Open Relays. Alarm Output: NO and NC Pilot Duty Operating Temperature Range: -10 to 50 C ( 14 to 125 F ) Enclosure: Water and dust tight. (IP55) Fuses: Main Fuse: 0.315 Amp Slow Secondary Fuse: 1.25 Amp Slow. Relays Fuse: 5 Amp. Slow 28/12/2003 Rev:1.2 Page 18

Wiring Diagram CO Protected RPLP-1 Unprotecte Heat 1 Humidity sensor GND Neutra Line Heat 2 Fan 1 Fan 2 Fan 3 Fan 4 Cooling 12V Black Red Outside temp sensor Inside temp Inside temp Neutral Alarm Fan 5 Relay 8 can be connected to an alarm system using COM and N.C terminals, or to Fan 5 using COM and N.O terminals. Note: alarm system can be also connected between COM and N.O in case alarm in open circuit is required. 28/12/2003 Rev:1.3 Page 19