FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Similar documents
INPUT / OUTPUT MINI MODULES

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Interface Modules for SENTRI

Addressable Loop Modules

Input/Output Modules Data Sheet

Intelligent addressable fire alarm control panel

FireNET Plus Wiring Instructions

The complete conventional fire warning system

Analogue addressable devices

Addressable and Conventional Fire Protection

Vega Devices.

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Conventional Fire Detection

General Routing Interface

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

DS7400Xi Addressable Control/ Communicator

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

MINERVA MX. 800 Series Ancillary Equipment

Multiple Input and Output Modules

MODEL B2 INSTALLATION MANUAL

Sita200plus. 200detectors. Single loop analogue addressable System

Installation, Operating and Maintenance Manual

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Touch Screen 1 loop Addressable Fire Alarm Panel

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

VAMP 120 & 121. Arc flash detection units. Product picture

ECO N DATE DESCRIPTION OF CHANGE CHG

Input module, input/output module

Power Supply Display Module PSDM. Installation and Operation Manual

EFBW series - BiWire Ultra control panel

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

NETWORK FIRE ALARM CONTROL PANEL. Features

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Control Panel Engineering and Commissioning Instructions

IGD.CO.UK

Control Relay Modules

An introduction to... Sigma

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

30.45 Electric Release PDRP-2001

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Conventional Smoke Detectors KFAPO

Intelligent Security & Fire Ltd

XP95 Sounder VAD Base

DATASHEET. Burner control unit FDA 601x

System 800 Addressable Fire Detection & Alarm System

TECHNICAL DATA OBSOLETE

RELEASE DEVICE CONTROLS

Remote NAC Power Supply D7038

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Reliably Advanced Extinguishing Control

Conventional Fire Alarm System Product Range Guide

Xenex Conventional Fire Detection & Alarm System

Excel-EN Conventional Fire Control Panel

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Conventional Fire Alarm System 2014 V1.2

Speed and Frequency Seite 1 von 7

Commercial and Light Industrial Fire Alarm Control Panel

AU MX Digital Loop Card Installation Instructions

Input module, input/output modules

Process Alarm Module RTA 421

Addressable NAC Output Module D327A

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Application, Installation, Operation & Maintenance Manual

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

OPERATION AND INSTALLATION MANUAL

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Notification Appliance Circuit Module

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

MODEL 5100 VOTING LOGIC MODULE

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

LDM-519-DIM LHDC MONITOR Digital Line Heat Detector Interface

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

KT-100 Door Controller

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

INTELLIGENT FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

SOUNDER CONTROL MODULE SCM-AS4

Fire control panel detect 3004 plus and accessories

Engineering Guideline. pac- Carriers Type Universal

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

CODESEC FIRE ALARM SYSTEMS. security technologies

Solution F2. Fire Alarm Control Panels one step ahead.

Industries. As a premier global manufacturing company, we believe that great brands are

Fire Control/Communicator

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

UEI-1 UNIVERSAL END-OF-LINE / ISOLATOR TESTER

Interface and EOL Modules 8

FEC400 Series. Installation Manual

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

The EN54 Part 2 & 4 Fire System

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Synova TM product catalog.

Transcription:

Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points, without the need for any external power supply. It can be supplied in five versions: >> FDMM10 Single input mini module >> FDMM01S Single output mini module >> FDMM02 Dual output (Form C) mini module >> FDMM11S Single input/output mini module >> FDMM12 Single input/dual output (Form C) mini module The vast combination of configuration makes the module to meet the demand of wide range of application such as Lift Control, AHU handling, Sprinkler Systems and Fire Fighting Integration, Door Controls or any other application where hard wired monitoring or control are required. Approvals & compliance with standards Technology The entire TELEDATA range confirms to BS5839 part 1&4, EN54 Standards. The Mini addressable modules are approved to EN-17 and EN-18. This only means enhanced reliability and precision performance. The mini modules embedded with the latest ATEIS digital protocol technology. The patented communication protocol has a unique design of. This new technology allows the data packets to be transmitted on the Fire Detection Loop for a long distances and does not gets affected with the Cable Characteristics. This technology clubbed with the DIN Rail configuration shall help a healthy communication at the worst site installation conditions or even during the sever fire conditions and especially in the industrial application. Features >> Complies to EN54-18 standards >> Connected and powered from the same loop >> Soft Addressing >> Safe Addressing >> Short Circuit Isolators complying to EN54-17 >> Up to 240 devices per loop >> Twin Bi-color LED driven from the control panel Physical construction & assembly The mini modules is constructed from high impact ABS designed to be fitted in any standard electrical box or in a weather box to enhance the IP rating. All the wires can be terminated on the screw channel, which is marked with numbers; depending on part number a full diagram is provided to insure proper installation. The unit is supplied with Bi-Color LED that provides status and alarm (Green / Red) indications and can be connected directly on the loop. Up to 240 devices can be connected and powered from the loop, each device shall have inbuilt isolator allowing the unit to be isolated in case of short circuit on the line, without affecting the other device on the loop. The Soft Addressing, Safe Addressing feature allows the commissioning team to set new address not necessary in the same sequence, this excellent feature shall allow the addressing to match site conditions or even allows the user to add more detectors to the loop at later stage without the need to change the addresses of all the devices. Each devise is supplied with in-built short circuit isolator complying to EN54-17, in case of a single fault; no device shall be lost on the loop. This shall only provide higher reliability to the performance as well easy of installation to comply with the latest standards and regulations. Two types of output modules provided. The supervised output can drive up to 2Amp of 30VDC or AC of a resistive type load, hence Open, Short and Earth conditions are fully monitored. This can be used to drive any conventional sounders, bells, Relays or any other Resistive Load type. The unsupervised relay output is of SPDT relay type; each module shall be supplied with two double throw relays of C form which drives the same type of load. The input modules shall supervise any input for Alarm, Short, Open and Earth conditions and can be used for the different types of monitoring such as, Sprinkler Systems, Fire Pumps or any other inputs from key switches, doors, alarms or fans.

The unit is equipped with twin Bi-color LED, which can give indications for Normal Operation Green or Alarm Red for every channel. Each Input or output module shall occupy one address, if combined in one unit shall occupy two addresses. If the VPU is used to address mini module, then first addressed shall be assigned to the Input and the output shall take one address higher. If the Soft addressing is used by the control panel, then Fire Panel shall assign all the addresses automatically. Architectural & engineering Specifications The unit must be the ATEIS module addressable intelligent control / monitor module. Up to 240 devices can be connected on the same detector loop based on the load factor. The intelligence addressable module shall be equipped with the latest state of the art microprocessor which shall control the communication and monitoring of the software and hardware of the unit. The unit shall communicate over state of the art Variable Time Communication VTC digital protocol from ATEIS which shall allow the safe and fast communication between the unit and the Fire Alarm Control Panel. The Module shall be equipped with twin Bi-color LED in both Red Alarm and Green Normal / Presence indications, one per channel. These LED s can be controlled fully from the Fire Alarm Control Panel. Each Intelligent Module shall be as well equipped with inbuilt isolator allowing the device to isolate itself from either side if a short may happen on the detector loop line. This feature must be fully complying with EN54-17 to allow no device lost in case of a single short on the loop. The Input modules shall fully monitor the third party connected to it for Open, Short, Earth, Alarm and Normal Condition. The end of line resistor of 27Kohm shall monitor the line for Open, earth or short, where as a series of 10Kohm alarm resistor can provide and alarm condition to the line. This feature allows monitoring both Alarm / Condition with one device and with one address. The output module shall be either of supervised or nonsupervised. Both shall drive 2Amp of 30 Volt DC/AC resistive loads. The supervised output can drive conventional Sounders, Bells, Relays or any other third party devices, where as the un-supervised is equipped with two SPDT double Throw C format relays that can drive 2Amp at 30Volt AC/DC resistive load. By using the VPU100 programmer can assign address to the unit, this safe addressing feature allows the device to have address after the Soft Addressing to match site requirements or special addressing requirements. The unit comes in mini enclosure format suitable to be mounted in any standard electrical box to suit environment conditions. General overview - FDMM10 input mini-module 1 5 6 12 7 Not used 8 Not used 9 Not used 10 Not used The FDMM10 single channel supervised input mini-module provides monitoring of normally open contact fire alarm and supervisory devices. End of line resistor ():27 Kohm. - Alarm resistor ():10 Kohm.

General overview - FDMM01S output supervised mini-module 1 7 8 9 10 12 5 Not used 6 Not used 7 Load (+) Supervised output (+) 8 Load (-) Supervised output (-) 9 Load power (+) Load s power supply (+) Load Load s Power 10 Load power (-) Load s power supply (-) The FDMM01S single channel supervised output mini-module provides control, by closing contacts, of auxiliary devices such as fire shutters. End of line resistor ():27 Kohm. General overview - FDMM02 output free contacts module 1 7 8 9 10 11 12 5 Not used 6 Not used 11 9 12 10 7 8 7 Common 1 Relay contact terminal 8 Common 2 Relay contact terminal 9 Normally open 1 Relay contact terminal 10 Normally open 2 Relay contact terminal 11 Normally closed 1 Relay contact terminal 12 Normally closed 2 Relay contact terminal TheFDMM02 single channel relay output mini-module provides pole changeover contacts for the control of auxiliary devices such as fire shutters.

General overview - FDMM11S input/output supervised mini-module 1 5 6 7 8 9 10 12 Load 7 Load (+) Supervised output (+) 8 Load (-) Supervised output (-) 9 Load power (+) Load s power supply (+) 10 Load power (-) Load s power supply (-) The FDMM11S input and output supervised DIN rail module combine in a single device supervised input and output characteristics. End of line resistor ():27 Kohm. - Alarm resistor ():10 Kohm. General overview - FDMM12 input/output free contacts mini-module 1 5 6 7 8 9 10 11 12 7 Common 1 Relay contact terminal 11 9 12 10 7 8 8 Common 2 Relay contact terminal 9 Normally open 1 Relay contact terminal 10 Normally open 2 Relay contact terminal 11 Normally closed 1 Relay contact terminal 12 Normally closed 2 Relay contact terminal When switching an inductive load, in order to protect the mini-module from surges caused by counter-emf, it is important to protect the relay contacts. A diode with a reverse breakdown voltage of at least ten times the circuit voltage (DC applications only) or a varistor (AC or DC applications) should be connected in parallel to the load.

Contac t 75 mm S Diode (D C only ) or Va ristor Lo ad VMMxxxx 40 Technical specifications Specification FDMM10 FDMM01S FDMM02 FDMM11S FDMM12 Standard EN54-18 / 17 Fault Protection Connection on the loop No of Devices per loop Power supply Aver Current Consumption LED s Current Consumption Operating Temp Dimensions Weight Max wire gage Ingress Protection In - built Isolator Loop Powered As per load calculator 15-40VDC I-120μA (@24VDC) 6mA (@24VDC) - 30 C to +70 C 75x52x28mm 180 grams 2.5mm² IP21C or higher when mounted in weather boxes Supervised Input 1 - - 1 1 Supervised Output - 1-1 - Un - supervised output - - 2-2