PLC / HMI Modbus (Slave) Addressing

Similar documents
Sequence of operation

READ AND SAVE THESE INSTRUCTIONS

OTC, OTM and OTI Series Options Index for PLC Control Systems:

SEQUENCE OF OPERATIONS

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

I/O ZONE 560/583 USERS GUIDE

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Modbus protocol REGO I

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

Tasman Sea Control System

opti-visor ultra-efficient chiller plant automation Typical specification

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Sales and Engineering Data Sheet ED

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Reference Guide for Microprocessor Controller

NQ Series Portable Chillers

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

IntesisBox BACnet/IP Server - Notifier ID3000 series

MicroTech Series-200 Flooded Screw Chiller

CONTROL PANEL OPERATING MANUAL AIR-COOLED SCREW CHILLER MICROTECH III CONTROLLER D EOMAC00A10-12EN

SCA 620C AIR COOLED SCREW CHILLER

For Complete Fire and Gas Solutions

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Lift Station Monitoring & Control The process begins here

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

F Technical Bulletin SC 370 SMART Modbus Interface

AIS750 Series Alarm Annunciator

RS485 MODBUS Module 8AI

SA Series Start up Report

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Air-Cooled SEMIHERMETIC

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Pre-Cool and Free- Cool Fan Control

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

LV CONTROLLER

Touch Screen Room Thermostat with Modbus Communication

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

1.1 Remote Annunciator Controller (RAC) and 1 Switch (ATC-600/800) via Modbus TCP/IP Ethernet Gateway

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

MicroTech Rooftop/RMC


The Book of AERMEC NRL Sequence of Operation

Mission Critical. Fuel Supply Systems

LUFKIN WELL MANAGER MODBUS MAP

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

RSMSD Technical Guide

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

Outstanding Performance; Application Flexibility

CONTROL PANEL OPERATING MANUAL WATER-COOLED SCREW CHILLER MICROTECH III CONTROLLER D EOMWC00A07-16EN

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

EC-BOS-602/616 AX Security

Touchscreen & PLC Control System

Kitchen Ventilation & HVAC Efficiency Solutions. Click to download presenta1on

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

Modbus RTU RS485 Manual

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

Application Manual LT-6617 Rev. 1 July 2017

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

ADAC. Advanced Deaerator Control

OPERATING MANUAL Enertronic Control System 2

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX

Case Study: New York Marriott Marquis BAS & Commissioning. Bill Michell, RPA, FMA, CEOE Director of Engineering

Modular Air Cooled Scroll Chillers

1.1 Ethernet Remote Annunciator Controller (RAC) using the up to 4 ATC-300+ connected via RS-485 to TCP/IP gateway

Super WISE. System product for Swegon s system for demand-controlled ventilation

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Manual for the integration in BMS/GTC

Tri-Stack Smart System

LCF Touch Modbus Datasheet Application Security Advice Caution

FPC-02 Series. Installation and Operating manual

Networkable Fan Coil Controller Specification and Installation Instructions

SPECTRACOOL Air Conditioner. N36 Model INSTRUCTION MANUAL. Rev. N 2014 Pentair Equipment Protection P/N

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

MEDICAL CHILLER SYSTEMS

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

MicroTech Series 200 Centrifugal Chiller

Open Protocol Data Communications

REMOTE CONTROL FOR CHILLER MYCHILLER

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

ModBus DE-1 INSTALLATION AND USER MANUAL

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

Refrigerated Incubator Model and Operating Instructions

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

DAP III Zone Master User s Guide

Process glycol chillers

Process Alarm Solutions

Operation Manual. Programmable Logic Controller

Energy Savings with Direct Digital Control

Hydronic & HVAC Control Systems

Transcription:

Made in the USA PLC / HMI Modbus (Slave) Addressing Legacy - HMI touch screen with built in Legacy - Pentra PLC with Expandable I/O Legacy Chiller Systems, Inc.

General Information IMPORTANT READ BEFORE STARTING WORK EQUIPMENT MUST BE INSTALLED BY QUALIFIED PERSONNEL IN ACCORDANCE WITH ALL LOCAL AND NATIONAL CODES. REMOTE (EXTERNAL) DATA COMMUMICATION WITH LEGACY PROCESS CHILLERS EQUIPPED WITH THE IDEC PENTRA PLC AND IDEC TOUCH SCREEN HMI IS POSSILE USING MODBUS COMMUMICATION PROTOCOL (ONLY) OVER A TCP ETHERNET NETWORK OR SERIAL (RTU) PROVIDED THE PENTRA PLC IS EQUIPPED WITH AN OPTIONAL SERIAL INTERFACE CARD. IN THE CASE OF ETHERNET COMMUNICATIONS, AN OPTIONAL MOXA ETHERNET SWITCH MUST BE INSTALLED IN THE CHILLER OR FIELD MOUNTED. THIS SWITCH WILL PROVIDE AN ADDITIONAL NETWORK PORT MAKING REMOTE COMMUNICATIONS POSSIBLE. THERE ARE A VARITY OF WAYS TO CONNECT LEGACY PLC / HMI EQUIPPED CHILLERS TO A LOCAL NETWORK. IN MANY CASES, A SPECIAL STATIC IP (MATCHING THE BUILDING NETWORK SUBNET) MUST BE INSTALLED BY THE FACTORY TO MAKE REMOTE COMMUNICATIONS POSSIBLE. FOR MORE INFORMATION ON IP ADDRESSING AND NETWORK COMMUNICATION OPTIONS, CONSULT THE LEGACY CHILLER SYSTEMS KNOWLEDGE BASE. BUILDING AUTOMATION SYSTEMS (BAS) MUST POINT AT THE PENTRA PLC AND BE CAPABLE OF CONTROLLING MODBUS SLAVE DEVICES OVER A TCP (ETHERNET) OR SERIAL (RTU) NETWORK. LEGACY CHILLER SYSTEMS DOES NOT PROVIDE NETWORK SUPPORT AS PART OF ITS STANDARD LIMITED MANUFACTURERS WARRANTY. NETWORK SUPPORT IS AVAILABLE AS A FEE BASED SERVICE UPON REQUEST. USERS ATTEMPTING MODUS COMMUNICATION WITH THE PENTRA PLC TAKE FULL RESPONSIBILITY FOR THEIR ACTIONS. PENTRA IS SET TO SLAVE MODE MEANING USER HAS THE ABILITY TO READ OR RIGHT TO ANY ONE OF THE ADDRESSES PROVIDED. ERRORS WRITING TO A PLC CAN CAUSE CATASTROPIC DAMAGE TO THE PROCESS CHILLER, CONNECTED LOAD, GENERAL PROPERTY DAMAGE AND PERSONAL INJURY EVEN DEATH. Page 2

Modbus - Network Address Table MODBUS *Modbus TYPE DESCRIPTION ADDRESS Command DATA FORMAT Alarm Status CP-1 High Pressure Alarm 001009 01 Read Coil Status Alarm Status CP-1 Low Pressure Alarm 001011 01 Read Coil Status Alarm Status CP-2 High Pressure Alarm 001010 01 Read Coil Status Alarm Status CP-2 Low Pressure Alarm 001012 01 Read Coil Status Alarm Status CP- 1 Protection module 001119 01 Read Coil Status Alarm Status CP- 2 Protection module 001120 01 Read Coil Status Alarm Status System Pump 1 Flow Alarm 001069 01 Read Coil Status Alarm Status System Pump 2 Flow Alarm 001070 01 Read Coil Status Alarm Status Recirc Pump Flow Alarm 001015 01 Read Coil Status Alarm Status Tank Low Level Indicator 001016 01 Read Coil Status Alarm Status Fluid High Temp Alarm 001017 01 Read Coil Status Alarm Status Fluid Low Temp Alarm 001018 01 Read Coil Status Setpoint CP-1 Temperature Setpoint 401201:401202 03 Read Holding Register 32- Float Setpoint CP-1 Differential Temperature Setpoint 401205:401206 03 Read Holding Register 32- Float Setpoint CP-2 Temperature Setpoint 401203:401204 03 Read Holding Register 32- Float Setpoint CP-2 Differential Temperature Setpoint 401207:401208 03 Read Holding Register 32- Float Analog Value Ambient Temp (F) 401047:401048 03 Read Holding Register 32- Float Analog Value TO Process Temperature (F) 401051:401052 03 Read Holding Register 32- Float Analog Value FROM Process Temperature (F) 401049:401050 03 Read Holding Register 32- Float Run Status Compressor ONE run status 000003 01 Read Coil Status Run Status Compressor TWO run status 000027 01 Read Coil Status Run Status System Pump ONE run status 000002 01 Read Coil Status Run Status System Pump TWO run status 000036 01 Read Coil Status Run Status Recirc Pump run status 000025 01 Read Coil Status Run Status Chiller Run Status Master Switch 001003 01 Read Coil Status * As a Modbus slave, all PLC data registers are set up for full read/write access. In the table above, we have provided a column indicating Read/Write as a recommendation only. Great care must be taken by user when access data registers in the above table. Incorrect settings can result in equipment damage, property damage, personal injury even death. Please proceed with extreme caution. Page 3

Modbus - Network Address Table TYPE System Pump MAN/AUTO System Pump MAN/AUTO System Pump #1 System Pump #2 Recirc Pump MAN/AUTO Recirc Pump MAN/AUTO Recirc Pump DESCRIPTION Sets system pump ONE and TWO for MANUAL CONTROL Sets system pump ONE and TWO for AUTO CONTROL Sets SYSTEM PUMP 1 to on or off. Sets SYSTEM PUMP 2 to on or off. Sets Recirc pump for MANUAL CONTROL Sets Recirc pump for AUTO CONTROL Sets Recirc pump to on or off. Compressor 1 - HP-PSI CP1 - HIGH Pressure Transducer PSI - Compressor 1 - LP-PSI CP1 - LOW Pressure Transducer PSI - Compressor 2 - HP-PSI CP2 - HIGH Pressure Transducer PSI - Compressor 2 LP-PSI CP2 - LOW Pressure Transducer PSI - MODBUS *Modbus ADDRESS Command 001041 01 Read Coil Status 001042 01 Read Coil Status 001022 01 Read Coil Status 001023 01 Read Coil Status 001043 01 Read Coil Status 001044 01 Read Coil Status 001021 01 Read Coil Status DATA FORMAT 400161 03 Read Holding Register 32- Float 400163 03 Read Holding Register 32- Float 400165 03 Read Holding Register 32- Float 400167 03 Read Holding Register 32- Float * As a Modbus slave, all PLC data registers are set up for full read/write access. In the table above, we have provided a column indicating Read/Write as a recommendation only. Great care must be taken by user when access data registers in the above table. Incorrect settings can result in equipment damage, property damage, personal injury even death. Please proceed with extreme caution. Page 4

Legacy Chiller Systems, Inc. 4224 Fowler Lane #201 P.O. Box 1120 Diamond Springs, CA 95619 Email: support@legacychillers.com Toll-free: Fax: 240-214-8303