Installation and operation manual for mixing modules FH-MJB and FH-MJC

Similar documents
Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

FHM-Cx Mixing Shunts for Floor Heating

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

FHM-Cx Mixing Shunts for Floor Heating

2.A MANIFOLD SHUNTS MINI SHUNTS

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Metering systems 0548EN April 2014

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS

T. +44 (0) E.

ModuSat TP. Energy. Heat Interface Units

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

7002K. art.7002k/2. art.7002k/1 DESCRIPTION. Complete mixing kit with circulation pump (ErP Ready 641/2009/EC - 622/2012/EC), thermostatic valve with

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

ModuSat TP. Energy. Heat Interface Units

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS

Herz York Direct Heat Interface Unit

Fits into compatible switch frames from manufacturers such as Busch-Jaeger, Gira, Berker and Merten.

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Lowara ecocirc and ecocirc PREMIUM

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Heating Control Danfoss Link & Connect Thermostats

LK Heat Exchanger Pack 10 -n

Lowara ecocirc and ecocirc PREMIUM

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

ELECTRIC CENTRAL HEATING FLOW BOILER

Automatic balancing valves ASV-PV (new generation) DN 32-50

Heat Interface Units for decentralised water heating in district heating systems

RA 2000 Series RA 15/6T & TB Conversion Valve

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

Systems for central heating

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

AVTI Multifunctional self - acting controller

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

Radiator Trap Radiator Valve

6 PIPING ARRANGEMENTS

RA15/6T & TB Conversion Valve

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

heat interface units A BOILER WITHOUT A FLAME

Introduction. Application. Technical data

Planning guide. (2010/09) en

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Technical Product Guide

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

product overview ProControl

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

TURBINE OIL FILTRATION AND DEHYDRATION UNIT - technical documentation - MODEL T1250

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

MAKING MODERN LIVING POSSIBLE. Akva Lux II TDP-F. Instructions for installation and use. Danfoss District Energy

Instructions for installation and use Akva Lux II VX substations 1. Contents

Radiator Valve Program

Indirect Expansion. USER MANUAL FOR OPERATORS AND PLUMBERS HEAT INTERFACE UNITS

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

ThermoDual Domestic hot water charging system

Renewable energies. Ready-made OEM systems for manufacturers of Solar thermal systems Solid fuel boilers (pellets, split logs, wood chips ) Heat pumps

Assessment Schedule - TS.6

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

- Data Brochure Universal Reset Module 422

Pivot Stove Hydronic Installation Guide

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

MONITRON II MODEL EH-M2 ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS. Four stage electronic control with energy saving and other features.

KOSPEL S.A. UL. OLCHOWA KOSZALIN

Mercury Mixing Kit (Code: ME1053)

SEALED THERMAL STORE

T. +44 (0) E.

The electrical wattage needed by the circulator is:

HW 22 District heating substation for indirect heating and domestic hot water systems

Components for solar heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

MODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Stored Water District Heating Interface Units. Heat Interface Units

Circulators high efficiency ECM Circulators

Installation, Operating and Servicing Instructions

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems

- Data Brochure Universal Reset Module 423

Transcription:

40 30 20 50 60 Installation and operation manual for mixing modules FH-MJB and FH-MJC Application The FH-MJB and FH-MJC mixing shunts are designed to supply floor heating areas up to approx. 40 m 2 (from pipe 16x2 mm onwards) in one- or two-pipe-systems. The connection of up to 2 floor heating circuits is possible. The FH-MJB and FH-MJC mixing shunts are provided with a temperature protection system that restricts the supply temperature in the floor heating circuit to max. 55 C. 1 8 3 4 10 5 6 11 2 9 7 1. Thermoelectric drive, pre-wired with pump, including a constant temperature control (A1-121 R, 20-70 C) for the connection of a room thermostat (not included in delivery). 2. Laing circulating pump with spherical motor A1-121 resp. A1-121 R. 3. Venting device. 4. Supply radiator-/boiler circuit. 5. Return radiator-/boiler circuit. 6. Supply floor heating circuit. 7. Return floor heating circuit. 8. Adjustable mixing valve. 9. Adjustable bypass for the radiator-/boiler circuit (recommended to be closed). 10. ON-OFF-switch for pump. 11. Flow temperature setting (KR version only). Mounting instructions FH-MJB / FH-MJC are connected directly to the existing radiator-/boiler circuit. When two circuits are connected to the FH-MJB / FH-MJC, the shortest circuit must be balanced by using an adjustable return screw connection. FH-MJB is pre-mounted in a flush mounted cabinet for wall opening (WxHxD: 40x33x11 cm). FH-MJC is pre-mounted in a surface mounted cabinet. FH-MJB / FH-MJC must be installed on a higher level than the floor heating installation. Ensure that the pre-pressure to FH-MJB / FH-MJC from the radiator-/vessel circuit is minimum 10 kpa (1 m). Before running FH-MJB / FH-MJC please check, that the floor heating system is filled, completely vented, and proved against leakage. Since the circulation pump might create under certain circumstances some flow noise, the FH-MJB / FH-MJC should be placed away from noise sensitive areas (i.e. sleeping rooms). The water temperature in the supply radiator-/ boiler circuit should be at least 10 K higher than in the floor heating supply. The maximum length of each pipe must not be longer than 100 m for floor heating design with spread of 10 K, when using pipes 12 mm i.d. (i.e. pipe 16x2). Smaller diameter pipe results in a shorter pipe length. Danfoss HES VI.SP.O2.02 Danfoss 06/2009 1

Hydraulic connection of two-pipe systems Bypass valve closed (Allen key 2.5 mm) Filling of the system It is mandatory to flush the floor heating loops before putting the system in operation, because otherwise malfunction or damage to the pump may result. We recommend using two fill valves on the primary side of the FH-MJB / FH-MJC, as shown in picture 2. Alternatively, the system can be filled using fill valves installed elsewhere in the system. In any case, it is necessary to positively flush the system since otherwise the air in the system will not be purged completely. Filling the system via the integrated manual air vent (see picture 4) is not possible! Please observe the position of the ball valve in the bypass. If this is in the vertical position, the floor heating loops are hydraulically uncoupled from the boiler loop. This position is ideal for normal operation (see picture 1), since the pump in the heating loop does not influence the floor heating loop. With the valve in this position, however, the floor heating system cannot be filled from the primary side. To fill the floor heating loops from the heating loop side, this ball valve must be closed (horizontal) see pictures 2 and 3. After filling, the valve must be opened again (vertical position). Please observe that when filling from the primary side radiator valves on that side should be closed in order to have maximum pump pressure available for purging the floor heating loops. Picture 1. Normal operation. Ball valve position open (vertical).!!! 2 VI.SP.O2.02 Danfoss 06/2009 Danfoss HES

Picture 2. Recommended filling of the system. Two fill valves on the primary side of the FH-MJB / FH-MJC allow for an easy filling and purging of air in the floor heating loops. The ball valve position must be closed (horizontal).!!! Picture 3. Good filling option. Two existing fill valves on the primary side allow for good filling and air purging. The ball valve position must be closed (horizontal).!!! Picture 4. Filling the system in this way is impossible since no forced flushing can be assured. Danfoss HES VI.SP.O2.02 Danfoss 06/2009 3

Hydraulic connection of one-pipe systems This pipe system is not longer standard. Connection scheme on request. Starting of operation without given values Remove protection cap / thermostatic head / electric drive from the FH-MJB / FH-MJC - see page 14, picture 1. Increase the supply temperature from the radiator-/boiler circuit to the designed value (normally 55-60 C). To perform the adjustment check, the room temperature has to be at least 20 C. If not, the system has to be run until the temperature increases. Check the floor heating supply temperature. It should be about 35-40 C. If it is too high, the flow from the primary supply has to be adjusted (reduced) - see page 14 picture 3. The FH-MJB / FH-MJC will be delivered from factory with fully opened mixing valve. We recommend an adjustment in small steps (1/2 turn). After each adjustment the floor heating supply temp Starting of operation with given values (pre-setting) Example: Given values: Heat requirement of underfloor heating system........................ 2000 Watt Supply temperature of radiator-/boiler system.............................70 C Return temperature of underfloor heating system.......................... 40 C Difference pressure of the radiator-/boiler circuit.......................... 10 kpa Specific heat capacity of water................................. 1.163 W / (Kg x K) Wanted values: Flow from the radiator-/boiler circuit: m = Q/(c x T) = 2000 W / (1.163 W / (kg x K) x 30 K) = 58 l/h Pre-setting: If the differential pressure from the radiator-/boiler circuit at the inlet and outlet of the FH-MJB / FH-MJC is 10 kpa and the flow requirement of the FH-MJB / FH-MJC is about 60 l, the mixing valve presetting has been opened by 1.6 turns. Turns to open N 4 VI.SP.O2.02 Danfoss 06/2009 Danfoss HES

Replacing the valve insert 1. Remove protection cap / actuator. 2. Remove valve insert. 3. Use enclosed tool to adjust the pre-setting of the mixing valve. 4. Screw valve insert in again. Dimensions FH-MJB FH-MJB is supplied pre-mounted into a cabinet for flush mounting. Dimensions (WxHxD), cm: 44,5 x 38,5 x 11,5 Wall opening (W x H x D), cm: 40,0 x 33,0 x 11,0 FH-MJC FH-MJC is supplied pre-mounted into a cabinet for surface mounting. Dimensions (WxHxD), cm: 41,5 x 31,5 x 11,5 Pump curve Danfoss HES VI.SP.O2.02 Danfoss 06/2009 5

Electrical connections Continous operating of pump Thermal electrical actuator (230 V, NC) brown blue Electronic RET 230P NO NC N L 1 2 3 Output: 1 = ON 2 = OFF 3 = COM Link terminals L and COM/3 for 230V output Pump brown blue yellow/green L 230 V~ N Pump also switched off by room thermostat Thermal electrical actuator (230 V, NC) brown blue Electronic RET 230P NO NC N L 1 2 3 Output: 1 = ON 2 = OFF 3 = COM Link terminals L and COM/3 for 230V output Pump brown blue yellow/green L 230 V~ N 6 VI.SP.O2.02 Danfoss 06/2009 Danfoss HES

Danfoss HES VI.SP.O2.02 Danfoss 06/2009 7

8 VI.SP.O2.02 Danfoss 06/2009 Danfoss HES