Datasheet - AZM 161SK-12/12RK-024

Similar documents
Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM ZRK 24 VAC/DC

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Datasheet - TVS /B-M20

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - MZM 100 B ST2-SD2PREM-A

Datasheet - MZM 100 ST-SD2PREM-A

SLC 220 E/R RFBS

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

One giant leap for safety: AZM400.

Conformity Approvals Rated insulation voltage Ui

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

PROTECT SRB 200EXi-1A

ISIS SAFETY SYSTEM Installation guide

Switches compliant with ATEX directive

Overload relays. General descriptions. Configuration of the front

Original operating instructions Safety switch with guard locking AC901S AC902S

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Safety in system: Protection for man and machine Innovations 2016/2017

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Multifunctional Gate Box MGB. More than safety.

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Flameproof Manual Call Points Series MCP

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Stego accessories for cabinets

Technical Data. General specifications. Rated operating distance s n 5 mm

Earth-Rite II PLUS Static Earthing System

Easy installation Certified for zones 1 and 21 High IP degree of protection

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Technical Data. Dimensions

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Explosion Proof Manual Call Points Series MCP

Operating Manual MS220KA and MSR220KA

Soft Starter Centrifugal Pump Soft Starter Series

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Flameproof Manual Call Points

SECTION AUTOMATIC TRANSFER SWITCHES

Basics of Safety Applications

LOVAG TEST INSTRUCTION IEC/EN

Flameproof Manual Call Points Series MCP

Basics of Safety Applications

Engineering Guideline. pac- Carriers Type Universal

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Snifter ATEX22 VERSION. User Manual. Distributor

02/11/2015

Inductive slot sensor

ATEX Safety Switches. More than safety.

BKA-EN Fire Damper. Additional operating instructions according to

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

RSGD. Three phase AC motor soft starter. Benefits. Description

ExPolar Heating System

Flostop TS D7E and A8E. Operation Manual

Thermal Management Products & Accessories for Enclosures

Technical Data. Dimensions

Gas cylinder scale Model GCS-1

DICTATOR Hold-Open Systems for Hazardous Areas

FAST RESPONSE TEMPERATURE SENSORS 42.11a

INSTRUCTION MANUAL (ATEX / IECEx)

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

BC3250. Blowdown Controller

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

BSK-RPR Fire Damper. Additional operating instructions according to

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

MICRO SWITCH GSX Series

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Safety Rope Pull Switches SRM, SR. General information on safety rope pull switches

UL HAZARDOUS LOCATIONS SERVICES

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Integrated Solutions Low Voltage Systems

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

02/11/2015

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X)

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

BERNSTEIN Safety Rope Pull Switches SR and SRM

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

new new Industrial plugs and sockets

Packaging industry Food and Beverage Solutions

SensaGuard TM Integrated Latch Installation Instructions

TYPE APPROVAL CERTIFICATE

Latch key safety limit switches Technical data

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Instructions for the fan motor control system with integrated wiring terminals SILVER C

PRELIMINARY EDITION

Moulded case circuit brakers

REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC. April 2015

Transcription:

30.10.2017-13:15:19h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 Preferred typ Thermoplastic enclosure Double-insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x 30 mm 6 Contacts Long life Large wiring compartment Manual release cable entries 4 M 16 x 1.5 (Minor differences between the printed image and the original product may exist!) Ordering details Product type description AZM 161SK-12/12RK-024 Article number 101164207 EAN code 4030661205144 ecl@ss 27-27-26-03 Approval Approval BG USA/CAN CCC Classification Standards EN ISO 13849-1 B10d Opener (NC) 2.000.000 Mission time 20 Years notice Global Properties

Product name AZM 161 Standards EN 60947-5-1, BG-GS-ET-19 Compliance with the Directives (Y/N) Yes Number of actuating directions 3 piece Active principle electromechanical Duty cycle Magnet 100 % Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, self-extinguishing - Material of the contacts Silver Housing coating None Weight 500 g Mechanical data Actuating play in direction of actuation 5.5 mm Design of electrical connection Screw connection Cable section - Min. Cable section 1 x 0,25 mm² - Max. Cable section 1 x 1.5 mm² Mechanical life > 1.000.000 operations notice All indications about the cable section are including the conductor ferrules. Emergency unlocking device (Y/N) No Manual release (Y/N) Yes Emergency release (Y/N) No Latching force 30 N Positive break force 20 N positive break travel 10 mm Clamping force F 2000 N Max. Actuating speed 2 m/s Actuating frequency max. 1000 / h Ambient conditions Ambient temperature - Min. environmental temperature 25 C - Max. environmental temperature +60 C Protection class IP67 to IEC/EN 60529 Electrical data Design of control element Switching principle Number of auxiliary contacts Number of safety contacts Power to unlock Power to lock Rated control voltage Us Power consumption Rated impulse withstand voltage Uimp Rated insulation voltage Ui Thermal test current Ithe Normally open contact (NO), Opener (NC) Creep circuit element 2 piece 4 piece Yes No 24 VAC/DC max. 10 W 4 kv 250 V Utilisation category AC-15: 230 V / 4 A, DC-13: 24 V / 2,5 A Required rated short-circuit current 6 A 1000 A

Max. fuse rating 6 A gg D-fuse To DIN EN 60269-1 ATEX Explosion protection categories for gases Explosion protected category for dusts None None Miscellaneous data Applications sliding safety guard, removable guard, hinged safety guard Dimensions Dimensions of the sensor - Width of sensor 130 mm - Height of sensor 90 mm - Length of sensor 30 mm notice Manual release For maintenance, installation, etc. For manual release using M5 triangular key, available as accessory Diagram Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact Switch travel diagram

Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel Ordering suffix The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: AZM 161SK-12/12RK-024G...G Protected against incorrect polarity and voltage spikes. limited terminating space 0,75 mm² Diagram 14 guard open 13 +24 VDC 63 0 VDC 64 unlocked Ordering code AZM 161 (1)-(2)(3)K(4)-(5)-(6)(7) (1) SK CC ST Screw connection Cage clamps male connector M12, 8- and 4-poles (Only for Us: 24 VAC/DC) (2) 12/12 2 Normally open contact (NO) / 4 Opener (NC) 12/11 2 Normally open contact (NO) / 3 Opener (NC) (Plug-in connection) 11/12 2 Normally open contact (NO) / 3 Opener (NC) (Plug-in connection) (3) without R Latching force 5 N Latching force 30 N

(4) without A (5) without ED EU T TD TU N Power to unlock Power to lock Manual release lateral Manual release cover-side Manual release rear Emergency exit lateral Emergency exit cover-side Emergency exit rear Emergency release (6) 024 Us: 24 VAC/DC 110/230 Us: 110/230 VAC (7) G with LED (Only for Us: 24 VAC/DC) Documents Operating instructions and Declaration of conformity (sv) 423 kb, 15.08.2012 Code: mrl_azm161_sv Operating instructions and Declaration of conformity (es) 566 kb, 09.03.2016 Code: mrl_azm161_es Operating instructions and Declaration of conformity (de) 439 kb, 29.01.2016 Code: mrl_azm161_de Operating instructions and Declaration of conformity (pt) 402 kb, 10.07.2014 Code: mrl_azm161_pt Operating instructions and Declaration of conformity (en) 443 kb, 29.01.2016 Code: mrl_azm161_en Operating instructions and Declaration of conformity (pl) 424 kb, 24.03.2014 Code: mrl_azm161_pl Operating instructions and Declaration of conformity (fr) 444 kb, 28.04.2016 Code: mrl_azm161_fr Operating instructions and Declaration of conformity (cs) 425 kb, 15.08.2012 Code: mrl_azm161_cs Operating instructions and Declaration of conformity (jp) 728 kb, 23.08.2016 Code: mrl_azm161_jp Operating instructions and Declaration of conformity (it) 438 kb, 19.04.2016 Code: mrl_azm161_it Operating instructions and Declaration of conformity (nl) 425 kb, 15.08.2012 Code: mrl_azm161_nl BG-test certificate (de) 140 kb, 20.05.2015 Code: z_m16p01

BG-test certificate (en) 134 kb, 20.05.2015 Code: z_m16p02 CCC certification (en) 1 MB, 13.06.2017 Code: q_371p02 CCC certification (cn) 1 MB, 13.06.2017 Code: q_371p03 EAC certification (ru) 809 kb, 05.10.2015 Code: q_6040p17_ru notice (de, en) 88 kb, 27.09.2007 Code: s_161p01 Images Dimensional drawing (basic component) Dimensional drawing (basic component)

Operating principle System components Actuator 101145117 - AZM 161-B1 101144416 - AZM 161-B1E 101171859 - AZM 161-B1ES 101175431 - AZM 161-B1F 101171125 - AZM 161-B1S 101173089 - AZM 161-B1-2053 WITH BALL LATCH

101164100 - AZM 161-B1-1747 WITH MAGNETIC LATCH 101178199 - AZM 161-B1-2024 101176642 - AZM 161-B1-2177 WITH CENTERING GUIDE 101174113 - AZM 161-B6-2177 WITH CENTERING GUIDE For very smal actuating radii 101170375 - AZM 161-B6S 101144420 - AZM 161-B6 For very smal actuating radii Door-handle system AZM 161-STS30 Latching handle Suitable for all types of guard suitable in combination with EX-AZM 161 Max. 110 C

Accessories 101100887 - TRIANGULAR KEY TK-M5 For manual release using M5 triangular key, available as accessory For maintenance, installation, etc. 101149213 - Mounting set MS AZM 161 R/P 101150376 - Mounting set MS AZM 161 P K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 30.10.2017-13:15:20h Kasbase 3.2.7.F.64I