TPLP PRE-ASSEMBLED LOW PROFILE EVAPORATORS

Similar documents
TPLP Pre-Assembled. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION. Air & Electric Defrost

High Profile Evaporator

KTL Two-Way Low Profile Unit Coolers

BTL Two-Way Low Profile Evaporators

KTL Two-Way Low Profile Evaporators

TLV Low Velocity Evaporators

ThermoSaver TM Hot Gas Defrost System

Half Round Evaporators

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Low Profile Unit Coolers

Installation, Operation, and Maintenance Information

Low Profile Unit Coolers

KR Series Air Defrost Unit Coolers Operating and Installation Manual

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

KR Electrical Defrost Unit Coolers (PN E108318_E)

LOW PROFILE UNIT COOLER

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR INDUSTRIAL COOLERS

Super-Flo Low Profile Unit Cooler

LOW PROFILE UNIT COOLER

Center Mount Unit Coolers

ThermoSaver TM Hot Gas Defrost System

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

InstructIon Manual KrEs EQuIPMEnt stands

Condensing Unit Installation and Operating Instructions

SM/SV-Space Master Unit Coolers (E R.0)

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

38TKB Air Conditioning Unit Installation and Start-Up Instructions

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

STC Series Twin Unit Coolers (E329630_A)

KCS-Line Air Cooled Condensers

IOM 410. Installation Operation Maintenance Information. UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Table of Contents

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS WALK-IN COOLERS SERIES LS-LP-LA-LV

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Low Flow Unit Coolers

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

Unit Coolers. Installation and Operations Manual. Table of Contents. H-IM-UC November 2017 Part No

T-Series Air Conditioner T53 Model

Electric Space Heater

T-Series Air Conditioner T15 Model

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Installation, Operation, and Maintenance Information

R E D I C O N T R O L S

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER

Condensing Unit Installation and Operating Instructions

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

KCC Centrifugal Fan Air Cooled Condensers

BALANCED PORT Q-VALVE

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

& MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION INDUSTRIAL COOLERS & FREEZERS WALK-IN COOLERS SERIES: EK, EM, EH, EI, EB, EF

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MCE4 Series. Electric Cooling Package Unit. Save these instructions for future reference

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Field Top Mounted Condensing Unit

T-Series Air Conditioner T20 Model

INSTRUCTIONS! DO NOT DISCARD!

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioners

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

38ASB/CCARS240~600 (036~060) AIR-COOLED CONDENSING UNIT

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

INSTALLATION AND OPERATING MANUAL

INSTRUCTIONS! DO NOT DISCARD!

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

INSTALLATION AND OPERATING MANUAL

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

INSTALLATION and OPERATION INSTRUCTIONS

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

Installation, Start-Up and Service Instructions

COMMERCIAL AIR COOLERS AIR AND ELECTRIC DEFROST

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Installation Instructions

COMMERCIAL AIR COOLERS AIR AND ELECTRIC DEFROST

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation & Maintenance Instructions

RPI Industries, Inc.

Transcription:

PRODUT DATA & INSTALLATION PRE-ASSEMBLED LOW PROFILE S N O W F E A T U R I N G Air & Electric DEFROST ELETRIAL POWER: 115/1/60, 208-230/1/60, 208-230/3/60, 460/1/60 See Page 16 for details Bulletin T30--PDI-6 1087152 For the latest product updates and further information, visit www.trentonrefrigeration.com ONTENTS Page Nomenclature... 2 Features & Options... 2 Pre-Assembled Features... 3 apacity Data... 4 Electrical Data... 7 Wiring Diagrams - Models with standard PS motors... 8-15 Wiring Diagrams - Models with optional E Motors / SmartSpeed... 16-20 Shipping Weights... 21 Dimensional Data... 22 Recommended Expansion Valve Selections... 23 Installation Instructions... 24-25 Generic Service Parts... 26 Warranty... 27 Project Information... 27 As Built Service Parts... Back 05/04/12

T = Trenton Pre-Assembled Low Profile Evaporator Number of Fans Nominal apacity: x 1000 @ 10 F TD, Btu/H, R404A NOMENLATURE T P LP 3 15 L E S2 B R6 - PS Application Range: M = Medium to High Temp 6 FPI (10 F to 45 F (-12 to 7 ) Evap Temp) L = Low Temp 6 FPI (-40 F to 0 F(-40 to -17 ) Evap Temp) V = Low Temp 4 FPI (-40 F to 0 F (-40 to -17 ) Evap Temp) Generation: B = 2 nd Voltage: S1 = 115/1/60 (air defrost models only) S2 = 208-230/1/60 S4 = 460/1/60 (2 to 6 fan models only) T3 = 208-230/3/60 Defrost*: A = Air Refrigerant Designation: R2 = R22 / R407 R6 = R404A E = Electric Motor Designation: PS = PS Permanent Split apacitor E2 = E Motor STANDARD FEATURES PS motors Streamlined cabinet style High efficiency, durable fan guard Front access ompact Internally enhanced tubing Spacious electrical and refrigeration compartments Low heater wattage Proven motor/fan/motor mount design Factory installed expansion valve, solenoid valve and room thermostat Schrader valve on suction header Positive slope, hinged drain pan entral drain connections (approximate) 3/4 ID Universal drain fitting for 3/4 MPT or 3/4 flare fitting Factory installed distributor nozzle 460/1/60 PS motor only OPTIONAL FEATURES E motors with SmartSpeed Technology (Patent Pending). See page 16 Heat exchanger - shipped loose Heresite oating opper or GW Aluminum Gold oat Fins Wire fan guard Painted abinet T30--PDI-6-2 - 05/04/12

PRE-ASSEMBLED FEATURES Thermostat Mounted on Front of Unit Solenoid Valve and TXV Mounted Solenoid Valve Wire pulled through and labeled on each end Schrader Valve Located Outside T30--PDI-6-3 - 05/04/12

APAITY DATA - R404A ALL MODELS Medium Temperature Models - apacity @ 6 F.P.I. Medium Temp. Models 104M 106M 107M 209M 211M 214M 317M 320M 423M 426M 532M 639M Number Of Fans 1 1 1 2 2 2 3 3 4 4 5 6 25/20 4300 5500 6800 8600 11000 14000 17000 20000 23000 26000 32000 39000 (-4/-7) (1260) (1610) (1990) (2520) (3220) (4100) (4980) (5860) (6740) (7610) (9370) (11400) apacity Evap 15 4260 5450 6730 8510 10890 13860 16830 19800 22770 25740 31680 38610 BTUH Temp. (-9) (1249) (1597) (1972) (2494) (3192) (4062) (4933) (5803) (6674) (7544) (9285) (11316) (WATTS) F ( ) 10 4210 5390 6660 8430 10780 13720 16660 19600 22540 25480 31360 38220 (-12) (1234) (1580) (1952) (2471) (3159) (4021) (4883) (5744) (6606) (7468) (9191) (11202) Air Flow FM (L/S) 1010 950 900 2020 1910 1800 2860 2700 3810 3600 4500 5400 (470) (450) (430) (950) (900) (850) (1350) (1270) (1800) (1700) (2120) (2550) Refrigerant harge LB. 0.7 1.0 1.3 1.3 1.9 2.5 2.8 3.7 3.7 4.9 6.1 7.2 R404A (KG) (0.3) (0.5) (0.6) (0.6) (0.9) (1.1) (1.3) (1.7) (1.7) (2.2) (2.7) (3.3) Low Temperature Models - apacity @ 6 F.P.I. Low Temp. Models 104L 105L 106L 207L 209L 211L 314L 317L 419L 422L 527L 631L Number Of Fans 1 1 1 2 2 2 3 3 4 4 5 6 0 (-18) 3930 (1150) 5200 (1520) 6090 (1780) 7930 (2320) 9720 (2850) 11500 (3370) 15100 (4420) 18100 (5300) 20000 (5860) 23000 (6740) 29000 (8490) 34400 (10100) -10 3870 5020 5960 7690 9400 11300 14600 17600 19600 22500 28100 32900 (-23) (1130) (1470) (1750) (2250) (2750) (3310) (4280) (5160) (5740) (6590) (8230) (9640) apacity Evap -20 3800 4800 5800 7400 9000 11000 14000 17000 19000 22000 27000 31000 BTUH Temp. (-29) (1110) (1410) (1700) (2170) (2640) (3220) (4100) (4980) (5570) (6440) (7910) (9080) (WATTS) F ( ) -30 3550 4410 5380 6820 8280 10200 12900 15700 17600 20400 24900 28400 (-34) (1040) (1290) (1580) (2000) (2430) (2990) (3780) (4600) (5160) (5980) (7290) (8320) -40 (-40) 3270 (960) 3980 (1170) 4920 (1440) 6180 (1810) 7470 (2190) 9340 (2740) 11700 (3430) 14300 (4190) 16100 (4720) 18800 (5510) 22500 (6590) 25300 (7410) Air Flow FM (L/S) 1010 950 900 2020 1910 1800 2860 2700 3810 3600 4500 5400 (480) (450) (430) (950) (900) (850) (1350) (1270) (1800) (1700) (2120) (2550) Refrigerant harge R404A @-20 F(-29 ) LB. (KG) 0.7 (0.3) 1.0 (0.5) 1.3 (0.6) 1.3 (0.6) 1.7 (0.8) 2.5 (1.1) 2.8 (1.3) 3.7 (1.7) 3.7 (1.7) 4.9 (2.2) 6.1 (2.7) 7.2 (3.3) Refrigerant harge R22 @ -20 F(-29 ) LB. (KG) 0.8 (0.3) 1.1 (0.5) 1.4 (0.6) 1.4 (0.6) 2.1 (0.9) 2.8 (1.2) 3.1 (1.4) 4.1 (1.8) 4.1 (1.8) 5.4 (2.4) 6.7 (3.0) 7.9 (3.6) Low Temperature Models - apacity @ 4 F.P.I. Low Temp. 4 FPI Models 103V 104V 105V 206V 208V 209V 312V 315V 416V 419V 523V 627V Number Of Fans 1 1 1 2 2 2 3 3 4 4 5 6 0 (-18) 3070 (900) 4340 (1270) 5170 (1510) 6720 (1970) 8240 (2410) 9610 (2820) 12600 (3690) 15700 (4600) 16600 (4860) 19600 (5740) 24200 (7090) 29100 (8520) -10 3040 4230 5100 6570 8040 9480 12300 15400 16300 19300 23600 28100 (-23) (890) (1240) (1490) (1920) (2360) (2780) (3600) (4510) (4770) (5650) (6910) (8230) apacity Evap -20 3000 4100 5000 6400 7800 9300 12000 15000 16000 19000 23000 27000 BTUH Temp. (-29) (880) (1200) (1470) (1880) (2290) (2720) (3520) (4390) (4690) (5570) (6740) (7910) (WATTS) F ( ) -30 2820 3790 4660 5930 7220 8680 11100 13900 14900 17800 21300 24900 (-34) (830) (1110) (1370) (1740) (2120) (2540) (3250) (4070) (4360) (5210) (6240) (7290) -40 (-40) 2620 (770) 3460 (1010) 4310 (1260) 5430 (1590) 6590 (1930) 8020 (2350) 10200 (2990) 12800 (3750) 13700 (4010) 16400 (4800) 19500 (5710) 22500 (6590) Air Flow FM (L/S) 1070 1010 950 2140 2020 1910 3030 2860 4040 3810 4770 5720 (510) (480) (450) (1010) (950) (900) (1430) (1350) (1910) (1800) (2250) (2700) Refrigerant harge R404A @-20 F(-29 ) LB. (KG) 0.7 (0.3) 1.0 (0.5) 1.3 (0.6) 1.3 (0.6) 1.7 (0.8) 2.5 (1.1) 2.8 (1.3) 3.7 (1.7) 3.7 (1.7) 4.9 (2.2) 6.1 (2.7) 7.2 (3.3) Refrigerant harge R22 @ -20 F(-29 ) LB. (KG) 0.8 (0.3) 1.1 (0.5) 1.4 (0.6) 1.4 (0.6) 2.1 (0.9) 2.8 (1.2) 3.1 (1.4) 4.1 (1.8) 4.1 (1.8) 5.4 (2.4) 6.7 (3.0) 7.9 (3.6) apacities rated using R404A with 10 F (5.6 ) TD & 100 F (38 ) liquid temperature. apacities at other TD within a range of 8 to 15 F (4.4 to 8.3 ) are directly proportional to TD, or use formula: apacity = Rated capacity 10 x TD. For capacities at TD outside of range 8 to 15 F (4.4 to 8.3 ), or liquid temperature lower than 75 F (24 ), consult factory. orrection Factors for Other Refrigerants Use R404A Values Multiplied By: R22 R134a R507 R407 * 0.95 0.90 1.00 0.90 * When using R407, the factor above is to be used when matching to condensing units with Dew Point ratings. This factor will ensure that proper system balancing will occur to compensate for glide to fit the application. If the system is sized correctly, one may expect a slight increase in system capacity, along with slightly higher saturated suction temperatures. T30--PDI-6-4 - 05/04/12

ELETRIAL DATA 115/1/60 - AIR DEFROST MODELS MODEL FPI QTY. HP FLA TOTAL PS MOTORS WATTS MIN. IR. AMPAITY (A) MOTORS MAX. FUSE (AMPS) HP E MOTORS FLA TOTAL WATTS MIN. IR. AMPAITY (A) MAX. FUSE (AMPS) 104MAS1 1 1/15 1.0 100 1.3 15 1/15 1.0 60 1.3 15 106MAS1 1 1/15 1.0 100 1.3 15 1/15 1.0 60 1.3 15 107MAS1 1 1/15 1.0 100 1.3 15 1/15 1.0 60 1.3 15 209MAS1 2 1/15 2.0 200 2.3 15 1/15 2.0 120 2.3 15 211MAS1 2 1/15 2.0 200 2.3 15 1/15 2.0 120 2.3 15 214MAS1 2 1/15 2.0 200 2.3 15 1/15 2.0 120 2.3 15 6 317MAS1 3 1/15 3.0 300 3.3 15 1/15 3.0 180 3.3 15 320MAS1 3 1/15 3.0 300 3.3 15 1/15 3.0 180 3.3 15 423MAS1 4 1/15 4.0 400 4.3 15 1/15 4.0 240 4.3 15 426MAS1 4 1/15 4.0 400 4.3 15 1/15 4.0 240 4.3 15 532MAS1 5 1/15 5.0 500 5.3 15 1/15 5.0 300 5.3 15 639MAS1 6 1/15 6.0 600 6.3 15 1/15 6.0 360 6.3 15 MODEL FPI QTY. ELETRIAL DATA 208-230/1/60 - AIR DEFROST MODELS HP FLA TOTAL PS MOTORS WATTS MIN. IR. AMPAITY (A) MOTORS MAX. FUSE (AMPS) HP FLA TOTAL E MOTORS WATTS MIN. IR. AMPAITY (A) MAX. FUSE (AMPS) 104MAS2 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.8 15 106MAS2 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.8 15 107MAS2 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.8 15 209MAS2 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 211MAS2 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 214MAS2 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 6 317MAS2 3 1/15 1.5 300 1.6 15 1/15 1.8 180 2.0 15 320MAS2 3 1/15 1.5 300 1.6 15 1/15 1.8 180 2.0 15 423MAS2 4 1/15 2.0 400 2.1 15 1/15 2.4 240 2.6 15 426MAS2 4 1/15 2.0 400 2.1 15 1/15 2.4 240 2.6 15 532MAS2 5 1/15 2.5 500 2.6 15 1/15 3.0 300 3.2 15 639MAS2 6 1/15 3.0 600 3.1 15 1/15 3.6 360 3.8 15 MODEL ELETRIAL DATA 460/1/60 - AIR DEFROST MODELS FPI QUANTITY HP FLA TOTAL MOTORS PS MOTORS WATTS MIN. IR. AMPAITY (A) MAX. FUSE (AMPS) 209MAS4 2 1/15 0.8 200 0.9 15 211MAS4 2 1/15 0.8 200 0.9 15 214MAS4 2 1/15 0.8 200 0.9 15 317MAS4 3 1/15 1.2 300 1.3 15 320MAS4 6 3 1/15 1.2 300 1.3 15 423MAS4 4 1/15 1.6 400 1.7 15 426MAS4 4 1/15 1.6 400 1.7 15 532MAS4 5 1/15 2.0 500 2.1 15 639MAS4 6 1/15 2.4 600 2.5 15 T30--PDI-6-5 - 05/04/12

ELETRIAL DATA - 208-230/1/60 & 208-230/3/60 ELETRI DEFROST MODELS MODEL FPI QTY. HP PS MOTORS FLA MA WATTS TOTAL (A) MOTORS MAX. FUSE (AMPS) HP E MOTORS FLA MA WATTS TOTAL (A) MAX. FUSE (AMPS) TOTAL WATTS TOTAL AMPS DEFROST HEATERS 208-230/1/60 208-230/3/60 MA (A) MAX. FUSE (AMPS) 104ME* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.8 15 1060 4.6 5.8 15 3.0 3.8 15 106ME* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.8 15 1060 4.6 5.8 15 3.0 3.8 15 107ME* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.8 15 1060 4.6 5.8 15 3.0 3.8 15 209ME* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 211ME* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 214ME* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 6 317ME* 3 1/15 1.5 300 1.6 15 1/15 1.8 180 2.0 15 2730 11.9 14.8 15 7.7 10 15 320ME* 3 1/15 1.5 300 1.6 15 1/15 1.8 180 2.0 15 2730 11.9 14.8 15 7.7 10 15 423ME* 4 1/15 2.0 400 2.1 15 1/15 2.4 240 2.6 15 3560 15.5 19.3 20 10 12 15 426ME* 4 1/15 2.0 400 2.1 15 1/15 2.4 240 2.6 15 3560 15.5 19.3 20 10 12 15 532ME* 5 1/15 2.5 500 2.6 15 1/15 3.0 300 3.2 15 4400 19.1 23.9 25 12 15.1 20 639ME* 6 1/15 3.0 600 3.1 15 1/15 3.6 360 3.8 15 5230 22.7 28.4 30 15 18 20 104LE* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.75 15 1060 4.6 5.8 15 3.0 3.8 15 105LE* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.75 15 1060 4.6 5.8 15 3.0 3.8 15 106LE* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.75 15 1060 4.6 5.8 15 3.0 3.8 15 207LE* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 209LE* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 211LE* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 6 314LE* 3 1/15 1.5 300 1.6 15 1/15 1.8 180 2.0 15 2730 11.9 14.8 15 7.7 10 15 317LE* 3 1/15 1.5 300 1.6 15 1/15 1.8 180 2.0 15 2730 11.9 14.8 15 7.7 10 15 419LE* 4 1/15 2.0 400 2.1 15 1/15 2.4 240 2.6 15 3560 15.5 19.3 20 10 12 15 422LE* 4 1/15 2.0 400 2.1 15 1/15 2.4 240 2.6 15 3560 15.5 19.3 20 10 12 15 527LE* 5 1/15 2.5 500 2.6 15 1/15 3.0 300 3.2 15 4400 19.1 23.9 25 12 15.1 20 631LE* 6 1/15 3.0 600 3.1 15 1/15 3.6 360 3.8 15 5230 22.7 28.4 30 15 18 20 103VE* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.75 15 1060 4.6 5.8 15 3.0 3.8 15 104VE* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.75 15 1060 4.6 5.8 15 3.0 3.8 15 105VE* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.75 15 1060 4.6 5.8 15 3.0 3.8 15 206VE* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 208VE* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 209VE* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 4 312VE* 3 1/15 1.5 300 1.6 15 1/15 1.8 180 2.0 15 2730 11.9 14.8 15 7.7 10 15 315VE* 3 1/15 1.5 300 1.6 15 1/15 1.8 180 2.0 15 2730 11.9 14.8 15 7.7 10 15 416VE* 4 1/15 2.0 400 2.1 15 1/15 2.4 240 2.6 15 3560 15.5 19.3 20 10 12 15 419VE* 4 1/15 2.0 400 2.1 15 1/15 2.4 240 2.6 15 3560 15.5 19.3 20 10 12 15 523VE* 5 1/15 2.5 500 2.6 15 1/15 3.0 300 3.2 15 4400 19.1 23.9 25 12 15.1 20 627VE* 6 1/15 3.0 600 3.1 15 1/15 3.6 360 3.8 15 5230 22.7 28.4 30 15 18 20 * = S2 or T3. Refer to Nomenclature for details TOTAL AMPS MA (A) MAX. FUSE (AMPS) T30--PDI-6-6 - 05/04/12

ELETRIAL DATA - 460/1/60 ELETRI DEFROST MODELS MODEL FPI QTY. HP FLA TOTAL MOTORS PS MOTORS WATTS MA (A) MAX. FUSE (AMPS) TOTAL WATTS DEFROST HEATERS TOTAL AMPS MA (A) MAX. FUSE (AMPS) 209MES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 211MES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 214MES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 317MES4 3 1/15 1.2 300 1.3 15 2730 5.9 7.4 15 320MES4 6 3 1/15 1.2 300 1.3 15 2730 5.9 7.4 15 423MES4 4 1/15 1.6 400 1.7 15 3560 7.7 9.7 15 426MES4 4 1/15 1.6 400 1.7 15 3560 7.7 9.7 15 532MES4 5 1/15 2.0 500 2.1 15 4400 9.6 12.0 15 639MES4 6 1/15 2.4 600 2.5 15 5230 11.4 14.2 15 207LES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 209LES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 211LES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 314LES4 3 1/15 1.2 300 1.3 15 2730 5.9 7.4 15 317LES4 6 3 1/15 1.2 300 1.3 15 2730 5.9 7.4 15 419LES4 4 1/15 1.6 400 1.7 15 3560 7.7 9.7 15 422LES4 4 1/15 1.6 400 1.7 15 3560 7.7 9.7 15 527LES4 5 1/15 2.0 500 2.1 15 4400 9.6 12.0 15 631LES4 6 1/15 2.4 600 2.5 15 5230 11.4 14.2 15 206VES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 208VES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 209VES4 2 1/15 0.8 200 0.9 15 1890 4.1 5.1 15 312VES4 3 1/15 1.2 300 1.3 15 2730 5.9 7.4 15 315VES4 4 3 1/15 1.2 300 1.3 15 2730 5.9 7.4 15 416VES4 4 1/15 1.6 400 1.7 15 3560 7.7 9.7 15 419VES4 4 1/15 1.6 400 1.7 15 3560 7.7 9.7 15 523VES4 5 1/15 2.0 500 2.1 15 4400 9.6 12.0 15 627VES4 6 1/15 2.4 600 2.5 15 5230 11.4 14.2 15 T30--PDI-6-7 - 05/04/12

WIRING DIAGRAM - 115/1/60, 208-230/1/60 STANDARD PS MOTORS AIR DEFROST MODELS PS WITH DEFROST TIME LOK WITHOUT DEFROST TIME LOK REFER TO NAMEPLATE FOR ELETRIAL REQUIREMENTS REFER TO NAMEPLATE FOR ELETRIAL REQUIREMENTS DEFROST LOK PARAGON # 8145 OR EQUIVALENT L1 L2(N) L1 L2(N) 1 3 2 TM 4 X N NOTE #3 OMIT 2ND FUSE IF(N) NOTE #3 F 4 OMIT 2ND FUSE IF(N) TO MULTIPLE S (IF APPLI) F 4 TO MULTIPLE EVAPS (IF APPLI) PUMP DOWN SPAE SWITH THERMOSTAT (IF USED) LIQUID LINE SOLENOID VALVE SPAE THERMOSTAT LIQUID LINE SOLENOID VALVE N.. N.. 4 F TERMINAL BOARD 4 F TERMINAL BOARD. MOTOR POWER PLUGS. MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY REFER TO DATA PLATE FOR MOTOR QUANTITY NOTES 1). USE OPPER ONDUTORS ONLY 2). USE 75 WIRE (OR HIGHER) 3). OVERURRENT PROTETION FOR MOTORS AND DEFROST HEATERS MUST NOT EXEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4). MAY BE FATORY INSTALLED-MOUNTED AND WIRED ON. 1-LP AIR 09/06 TERMINALS -OMPONENT TERMINAL -TERMINAL BLOK TERMINAL ONDUTORS/WIRING FATORY WIRING WIRING BY OTHERS OPTIONAL FATORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN OMPLIANE WITH ALL APPLIABLE LOAL AND NATIONAL ODES. T30--PDI-6-8 - 05/04/12

WIRING DIAGRAM - 460/1/60 STANDARD PS MOTORS AIR DEFROST MODELS PS WITH DEFROST TIME LOK WITHOUT DEFROST TIME LOK 460-1-60 Hz 380/400-1-50Hz L1 L2 ONTROL VOLTAGE 460-1-60 Hz 380/400-1-50Hz ONTROL VOLTAGE DEFROST LOK PARAGON # 8145 OR EQUIVALENT L1 L2(N) L1 L2 L1 L2(N) 1 3 2 TM 4 X N NOTE #3 OMIT 2ND FUSE IF(N) NOTE #3 OMIT 2ND FUSE IF(N) M2 M1 TO MULTIPLE S (IF APPLI) M2 M1 TO MULTIPLE S (IF APPLI) PUMP DOWN SPAE LIQUID LINE SWITH THERMOSTAT SOLENOID VALVE (IF USED) N.. SPAE THERMOSTAT LIQUID LINE SOLENOID VALVE N.. M1 M2 TERMINAL BOARD 4 N M1 M2 TERMINAL BOARD 4 N. MOTOR POWER PLUGS. MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY REFER TO DATA PLATE FOR MOTOR QUANTITY NOTES 1). USE OPPER ONDUTORS ONLY 2). USE 75 WIRE (OR HIGHER) 3). OVERURRENT PROTETION FOR MOTORS AND DEFROST HEATERS MUST NOT EXEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4). MAY BE FATORY INSTALLED-MOUNTED AND WIRED ON. 6-LP 460 AIR 09/06 TERMINALS -OMPONENT TERMINAL -TERMINAL BLOK TERMINAL ONDUTORS/WIRING FATORY WIRING WIRING BY OTHERS OPTIONAL FATORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN OMPLIANE WITH ALL APPLIABLE LOAL AND NATIONAL ODES. T30--PDI-6-9 - 05/04/12

PS WIRING DIAGRAM - 208-230/1/60 STANDARD PS MOTORS ELETRI DEFROST MODELS - SINGLE 10A MAX. FOR ALL MODELS WITHOUT DEFROST HEATER ONTATOR USING MAXIMUM 15A HEATER OVERURRENT PROTETION DEFROST LOK PARAGON # 8145 OR EQUIVALENT REFER TO NAMEPLATE FOR ELETRIAL REQUIREMENTS L1 L2 TM 3 4 X 1 2 N 15A OMPR INTERLOK (IF USED) SPAE THERMOSTAT N.. WARNING EVAP FIELD MODIFIATION MUST BE MADE PUMP DOWN SWITH (IF USED) LIQUID LINE SOL VALVE SEE NOTE: 1 RELOATE WHITE WIRE FROM N TO H1 AS SHOWN 2 INSTALL ORANGE JUMPER (SUPPLIED LOOSE) FROM H2 TO N 2 ORANGE JUMPER 4 F X N 3 H1 H2 H3. BK BN DT FD RD 1 DEFROST TERMINATION & DELAY ONTROL DT-DEFROST TERM FD- DELAY WH HEATER LIMIT SWITH YL DEFROST HEATERS 1 2 6 MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY NOTES 1). USE OPPER ONDUTORS ONLY 2). USE 75 WIRE (OR HIGHER) 3). OVERURRENT PROTETION FOR MOTORS AND DEFROST HEATERS MUST NOT EXEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4.) MAY BE FATORY INSTALLED-MOUNTED AND WIRED ON TERMINALS -OMPONENT TERMINAL -TERMINAL BLOK TERMINAL ONDUTORS/WIRING FATORY WIRING WIRING BY OTHERS OPTIONAL FATORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN OMPLIANE WITH ALL APPLIABLE LOAL AND NATIONAL ODES. 2-LP ED 12/07 T30--PDI-6-10 - 05/04/12

WIRING DIAGRAM - 208-230/1/60 STANDARD PS MOTORS ELETRI DEFROST MODELS - SINGLE PS DEFROST LOK PARAGON # 8145 OR EQUIVALENT FOR ALL MODELS USING DEFROST HEATER ONTATOR REFER TO NAMEPLATE FOR ELETRIAL REQUIREMENTS L1 L2 TM 3 4 X 1 2 N NOTE #3 NOTE #3 OMPR INTERLOK (IF USED) L1 T1 L2 T2 DEFROST HEATER ONTATOR SPAE THERMOSTAT N.. PUMP DOWN SWITH (IF USED) LIQUID LINE SOL VALVE 4 F X N 3 H1 H2 H3. BK BN DT FD RD WH YL DEFROST TERMINATION & DELAY ONTROL DT-DEFROST TERM FD- DELAY HEATER LIMIT SWITH DEFROST HEATERS 1 2 6 MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY NOTES 1). USE OPPER ONDUTORS ONLY 2). USE 75 WIRE (OR HIGHER) 3). OVERURRENT PROTETION FOR MOTORS AND DEFROST HEATERS MUST NOT EXEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4.) MAY BE FATORY INSTALLED-MOUNTED AND WIRED ON 3-LP ED ONTATOR SINGLE 12/07 TERMINALS -OMPONENT TERMINAL -TERMINAL BLOK TERMINAL ONDUTORS/WIRING FATORY WIRING WIRING BY OTHERS OPTIONAL FATORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN OMPLIANE WITH ALL APPLIABLE LOAL AND NATIONAL ODES. T30--PDI-6-11 - 05/04/12

WIRING DIAGRAM - 208-230/3/60 STANDARD PS MOTORS ELETRI DEFROST MODELS - SINGLE PS FOR ALL MODELS USING 3 PHASE DEFROST HEATER ONTATOR DEFROST LOK PARAGON # 8145 OR EQUIVALENT REFER TO NAMEPLATE FOR ELETRIAL REQUIREMENTS L1 L2 L3 TM 3 4 X 1 2 N NOTE #3 NOTE #3 L1 L2 L3 DEFROST HEATER ONTATOR OMPR INTERLOK (IF USED) T1 T2 T3 SPAE THERMOSTAT N.. PUMP DOWN SWITH (IF USED) LIQUID LINE SOL VALVE. 4 F X BK BN DT FD DEFROST TERMINATION & DELAY ONTROL DT-DEFROST TERM FD- DELAY RD N WH 3 YL HEATER LIMIT SWITH H1 H2 H3 DEFROST HEATERS 1 2 6 MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY NOTES 1). USE OPPER ONDUTORS ONLY 2). USE 75 WIRE (OR HIGHER) 3). OVERURRENT PROTETION FOR MOTORS AND DEFROST HEATERS MUST NOT EXEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4.) MAY BE FATORY INSTALLED-MOUNTED AND WIRED ON 3A-LP ED 3ph.ONTATOR SINGLE 12/07 TERMINALS -OMPONENT TERMINAL -TERMINAL BLOK TERMINAL ONDUTORS/WIRING FATORY WIRING WIRING BY OTHERS OPTIONAL FATORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN OMPLIANE WITH ALL APPLIABLE LOAL AND NATIONAL ODES. T30--PDI-6-12 - 05/04/12

WIRING DIAGRAM - 460/1/60 STANDARD PS MOTORS ELETRI DEFROST MODELS - SINGLE PS FOR ALL 460V MODELS USING DEFROST HEATER AND ONTATORS DEFROST LOK PARAGON # 8145 OR EQUIVALENT REFER TO NAMEPLATE FOR ELETRIAL REQUIREMENTS L1 L2(N) L1 L2 TM 3 4 X 1 2 N NOTE #3 NOTE #3 OMPR INTERLOK (IF USED) L1 T1 L2 T2 DEFROST HEATER ONTATOR L1 T1 L2 T2 EVAP ONTATOR SPAE THERMOSTAT N.. PUMP DOWN SWITH (IF USED) LIQUID LINE SOL VALVE M1 M2 H1 H2 4 3 F X N. BN BK DT FD RD OIL DEFROST HEATERS DEFROST TERMINATION & DELAY ONTROL DT-DEFROST TERM FD- DELAY YL WH MOTOR POWER PLUGS REFER TO EVAPORTOR DATA PLATE FOR MOTOR QUANTITY HEATER LIMIT SWITH NOTES 1). USE OPPER ONDUTORS ONLY 2). USE 75 WIRE (OR HIGHER) 3). OVERURRENT PROTETION FOR MOTORS AND DEFROST HEATERS MUST NOT EXEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4.) MAY BE FATORY INSTALLED-MOUNTED AND WIRED ON 7-LP ED ONTATOR SINGLE 12/07 TERMINALS -OMPONENT TERMINAL -TERMINAL BLOK TERMINAL ONDUTORS/WIRING FATORY WIRING WIRING BY OTHERS OPTIONAL FATORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN OMPLIANE WITH ALL APPLIABLE LOAL AND NATIONAL ODES. T30--PDI-6-13 - 05/04/12

WIRING DIAGRAM - 208-230/1/60 STANDARD PS MOTORS ELETRI DEFROST MODELS - MULTIPLE S FOR ALL MODELS USING DEFROST HEATER ONTATOR PS DEFROST LOK PARAGON # 8145 OR EQUIVALENT REFER TO NAMEPLATE FOR ELETRIAL REQUIREMENTS L1 L2 TM 3 4 X 1 2 N NOTE #3 NOTE #3 OMPR INTERLOK (IF USED) L1 T1 L2 T2 DEFROST HEATER ONTATOR WARNING N.. NOTE #3 EVAP#2 FIELD MODIFIATION MUST BE MADE SEE NOTE: PUMP DOWN SWITH (IF USED) SPAE THERMOSTAT LIQUID LINE SOL VALVE 1 2 RELOATE WHITE WIRE FROM N AS SHOWN REMOVE AND INSULATE AS SHOWN 4 F X N 3 H1 H2 4 F X N 3 H1 H2. BK BN DT FD RD WH YL. 2 BK BN DT FD RD WH 1 YL DEFROST TERMINATION & DELAY ONTROL DT-DEFROST TERM FD- DELAY HEATER LIMIT SWITH DEFROST TERMINATION & DELAY ONTROL DT-DEFROST TERM FD- DELAY HEATER LIMIT SWITH DEFROST HEATERS * Remove & Insulate DEFROST HEATERS MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY PRIMARY MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY SEONDARY * Fan delay not used on second evap / use fan contactor if total fan amps exceeds 10A NOTES 1). USE OPPER ONDUTORS ONLY 2). USE 75 WIRE (OR HIGHER) 3). OVERURRENT PROTETION FOR MOTORS AND DEFROST HEATERS MUST NOT EXEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4.) MAY BE FATORY INSTALLED-MOUNTED AND WIRED ON 4-LP ED ONTATOR MULTI 12/07 TERMINALS -OMPONENT TERMINAL -TERMINAL BLOK TERMINAL ONDUTORS/WIRING FATORY WIRING WIRING BY OTHERS OPTIONAL FATORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN OMPLIANE WITH ALL APPLIABLE LOAL AND NATIONAL ODES. T30--PDI-6-14 - 05/04/12

WIRING DIAGRAM - 460/1/60 STANDARD PS MOTORS ELETRI DEFROST MODELS - MULTIPLE S PS FOR ALL 460V MODELS USING DEFROST HEATER AND ONTATORS DEFROST LOK PARAGON # 8145 OR EQUIVALENT REFER TO NAMEPLATE FOR ELETRIAL REQUIREMENTS L1 L2(N) L1 L2 TM 3 4 X NOTE #3 1 N NOTE #3 2 DEFROST HEATER L1 L2 ONTATOR OMPR INTERLOK (IF USED) T1 T2 L1 T1 L2 T2 EVAP ONTATOR PUMP DOWN SWITH (IF USED) SPAE THERMOSTAT N.. LIQUID LINE SOL VALVE NOTE #3 1 WARNING EVAP#2 FIELD MODIFI- ATION MUST BE MADE RELOATE WHITE WIRE FROM N AS SHOWN * M1 M2 H1 H2 4 3 F X N M1 M2 H1 H2 4 3 F X N. BN BK DT RD. BN DT BK RD 1 FD FD DEFROST TERMINATION & DELAY ONTROL DEFROST TERMINATION & DELAY ONTROL DEFROST HEATERS DT-DEFROST TERM FD- DELAY DEFROST HEATERS DT-DEFROST TERM FD- DELAY YL WH YL WH MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY HEATER LIMIT SWITH PRIMARY MOTOR POWER PLUGS REFER TO DATA PLATE FOR MOTOR QUANTITY HEATER LIMIT SWITH SEONDARY * Note: Fan Delay not used on second evap NOTES 1). USE OPPER ONDUTORS ONLY 2). USE 75 WIRE (OR HIGHER) 3). OVERURRENT PROTETION FOR MOTORS AND DEFROST HEATERS MUST NOT EXEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4.) MAY BE FATORY INSTALLED-MOUNTED AND WIRED ON 8-LP 460v ED ONTATOR MULTI 09/06 TERMINALS -OMPONENT TERMINAL -TERMINAL BLOK TERMINAL ONDUTORS/WIRING FATORY WIRING WIRING BY OTHERS OPTIONAL FATORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN OMPLIANE WITH ALL APPLIABLE LOAL AND NATIONAL ODES. T30--PDI-6-15 - 05/04/12

EM PATENT PENDING DESIGN FEATURES Standard on all E Motors NO special controls required. Refrigeration mode E motor operates at full speed. onsumption 60 W per motor Off ycle mode E motor operates at reduced speed. onsumption 13 W per motor. Energy saving benefit on motor and compressor wattage consumption: 20000 18000 16000 ENErGY consumption comparison: with PSc vs EcM vs SmartSpeed Evaporator Fan Motors ompressor w/ PS ompressor w/ EM Energy consumption (Watt-Hours) 14000 12000 10000 8000 6000 4000 2000 0 compressor w/ SmartSpeed ADDITIONAL ENERGY SAVINGS WHEN USING SMARTSPEED EVAPS EVAP w/ PS EVAP w/ EM EVAP with SmartSpeed 0 50 100 150 200 250 300 350 400 450 500 time (minutes) Note: Data collected on a typical freezer application with a 3HP low temp condensing unit and a 4 fan evaporator INSTALLATION NOTES E motors are factory wired for SmartSpeed operation on evaporators equipped with a factory installed thermostat. For SmartSpeed operation on Evaporators without a factory installed thermostat, a field wired SPDT type thermostat is required. T30--PDI-6-16 - 05/04/12

WIRING DIAGRAM - 115/1/60, 208-230/1/60 OPTIONAL E MOTORS with AIR DEFROST MODELS EM T30--PDI-6-17 - 05/04/12

WIRING DIAGRAM - 208-230/1/60 OPTIONAL E MOTORS with ELETRI DEFROST MODELS EM T30--PDI-6-18 - 05/04/12

WIRING DIAGRAM - 208-230/1/60 OPTIONAL E MOTORS with ELETRI DEFROST MODELS - MULTIPLE S EM T30--PDI-6-19 - 05/04/12

WIRING DIAGRAM - 208-230/1/60 OPTIONAL E MOTORS w/ + ELETRI DEFROST MODELS EM T30--PDI-6-20 - 05/04/12

Air Defrost Models SHIPPING WEIGHTS Electric Defrost Models MODEL NUMBER SHIPPING WEIGHT LB. (kg) 104MA 45 (20) 106MA 47 (21) 107MA 49 (22) 209MA 70 (32) 211MA 74 (33) 214MA 78 (35) 317MA 101 (46) 320MA 107 (48) 423MA 117 (53) 426MA 135 (61) 532MA 163 (74) 639MA 192 (87) MODEL NUMBER SHIPPING WEIGHT LB. (kg) 104ME 104LE 103VE 49 (22) 106ME 105LE 104VE 51 (23) 107ME 106LE 105VE 53 (24) 209ME 207LE 206VE 76 (34) 211ME 209LE 208VE 80 (36) 214ME 211LE 209VE 84 (38) 317ME 314LE 312VE 109 (49) 320ME 317LE 315VE 115 (52) 423ME 419LE 416VE 127 (58) 426ME 422LE 419VE 145 (66) 532ME 527LE 523VE 176 (80) 639ME 631LE 627VE 207 (94) T30--PDI-6-21 - 05/04/12

DIMENSIONAL DATA 15 7/8 [403].438 SLOTS IN MOUNTING BRAKETS AIR THROW APPROX 35' IN OPEN SPAE REFRIGERATION ONNETIONS. SUTION & LIQUID. 6 1/2 [165] 4 [102] TYP A B 6 1/2 [165] ELETRIAL ONNETIONS. 1 3/8 3 [35] [76] 3/4 MPT / 3/4 FLARE DRAIN ONNETION 13 7/16 [341] MTG SLOTS 1, 2 AND 3 MODELS. (TOP VIEW) 12 [305] 11 7/8 [302] 3 1/8 [79] MINIMUM 6 1/2 [165] A B 13 7/16 [341] MTG SLOTS 4, 5 AND 6 MODELS. (TOP VIEW) MODEL NO. OF S A B SUTION LIQUID ONNETION (ID) ONNETION SWEAT IN (mm) IN (mm) IN (mm) (ID) SWEAT R22 R404A 104M^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 106M^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 107M^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 209M^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 211M^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 214M^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 317M^ 3 62 1/4 (1581) 49 1/4 (1251) N/A N/A 7/8 3/8 3/8 320M^ 3 62 1/4 (1581) 49 1/4 (1251) N/A N/A 7/8 3/8 3/8 423M^ 4 78 1/4 (1988) 32 5/8 (829) 32 5/8 (829) 1 1/8 3/8 3/8 426M^ 4 78 1/4 (1988) 32 5/8 (829) 32 5/8 (829) 1 1/8 3/8 3/8 532M^ 5 94 1/4 (2394) 32 5/8 (829) 48 5/8 (1235) 1 3/8 3/8 3/8 639M^ 6 110 1/4 (2800) 48 5/8 (1235) 48 5/8 (1235) 1 3/8 3/8 3/8 104L^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 105L^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 106L^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 207L^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 209L^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 211L^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 314L^ 3 62 1/4 (1581) 49 1/4 (1251) N/A N/A 7/8 3/8 3/8 317L^ 3 62 1/4 (1581) 49 1/4 (1251) N/A N/A 1 1/8 3/8 3/8 419L^ 4 78 1/4 (1988) 32 5/8 (829) 32 5/8 (829) 1 1/8 3/8 1/2 422L^ 4 78 1/4 (1988) 32 5/8 (829) 32 5/8 (829) 1 1/8 3/8 1/2 527L^ 5 94 1/4 (2394) 32 5/8 (829) 48 5/8 (1235) 1 3/8 3/8 1/2 631L^ 6 110 1/4 (2800) 48 5/8 (1235) 48 5/8 (1235) 1 3/8 3/8 1/2 103V^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 104V^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 105V^ 1 30 1/4 (768) 17 1/4 (438) N/A N/A 5/8 3/8 3/8 206V^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 208V^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 209V^ 2 46 1/4 (1175) 33 1/4 (845) N/A N/A 7/8 3/8 3/8 312V^ 3 62 1/4 (1581) 49 1/4 (1251) N/A N/A 7/8 3/8 3/8 315V^ 3 62 1/4 (1581) 49 1/4 (1251) N/A N/A 1 1/8 3/8 3/8 416V^ 4 78 1/4 (1988) 32 5/8 (829) 32 5/8 (829) 1 1/8 3/8 1/2 419V^ 4 78 1/4 (1988) 32 5/8 (829) 32 5/8 (829) 1 1/8 3/8 1/2 523V^ 5 94 1/4 (2394) 32 5/8 (829) 48 5/8 (1235) 1 3/8 3/8 1/2 627V^ 6 110 1/4 (2800) 48 5/8 (1235) 48 5/8 (1235) 1 3/8 3/8 1/2 ^ = A or E. Refer to Nomenclature for details T30--PDI-6-22 - 05/04/12

REOMMENDED EXPANSION VALVE SELETIONS MEDIUM TEMPERATURE MODELS MODEL FATORY INSTALLED NOZZLE R404A R507 R22 R407 104M N/A TUAE-R404A-4-N TUAE-R22-4-N 106M L-1/2 TUAE-R404A-5-N TUAE-R22-5-N 107M L-1/2 TUAE-R404A-6-N TUAE-R22-5-N 209M L-3/4 TUAE-R404A-7-N TUAE-R22-6-N 211M L-1 TUAE-R404A-7-N TUAE-R22-6-N 214M L-1 TUAE-R404A-8-N TUAE-R22-7-N 317M L-1 1/2 TUAE-R404A-8-N TUAE-R22-8-N 320M L-1 1/2 TUAE-R404A-9-N TUAE-R22-8-N 423M L-2 TUAE-R404A-9-N TUAE-R22-8-N 426M L-2 TAE-R404A-T1-N TUAE-R22-9-N 532M L-2 1/2 TAE-R404A-T2-N TUAE-R22-9-N 639M G-3 TAE-R404A-T3-N TAE-R22-T1-N If using 407, superheat setting must be adjusted by turning 1-1.5 turns clockwise. Above selections based on: 1) 100 F (38 ) vapor free liquid entering expansion valve 2) 110 F (43 ) ondensing temperature 3) 8-12 F (4.4-6.7 ) evaporator TD If correct nozzle is not available, the proper orifice size can be drilled in the field using the following chart NOZZLE ORIFIE No. Drill SIZE IN. 1/2.070 3/4.086 1.0995 1-1/2.120 2.1406 2-1/2.157 3.172 4.199 5.211 6.242 8.266 10.281 MODEL LOW TEMPERATURE R404A R507 MODELS FATORY INSTALLED NOZZLE 0 F (-18 ) EVAP. -10 F (-23 ) EVAP. -20 F (-29 ) EVAP.* -30 F (-34 ) EVAP. -40 F (-40 ) EVAP. 104L L-1/2 TUAE-R404A-5-N TUAE-R404A-5-NM TUAE-R404A-6-NM TUAE-R404A-7-NM TUAE-R404A-6-NM 105L L-3/4 TUAE-R404A-6-N TUAE-R404A-6-NM TUAE-R404A-6-NM TUAE-R404A-7-NM TUAE-R404A-7-NM 106L L-1 TUAE-R404A-6-N TUAE-R404A-6-NM TUAE-R404A-7-NM TUAE-R404A-7-NM TUAE-R404A-7-NM 207L L-1 TUAE-R404A-7-N TUAE-R404A-7-NM TUAE-R404A-7-NM TUAE-R404A-8-NM TUAE-R404A-8-NM 209L 1-1/2 TUAE-R404A-8-N TUAE-R404A-8-NM TUAE-R404A-8-NM TUAE-R404A-9-NM TUAE-R404A-8-NM 211L L-2 TUAE-R404A-8-N TUAE-R404A-8-NM TUAE-R404A-9-NM TUAE-R404A-9-NM TUAE-R404A-9-NM 314L L-2 TUAE-R404A-9-N TUAE-R404A-9-NM TUAE-R404A-9-NM TAE-R404A-T1-NM TAE-R404A-T1-NM 317L L-3 TUAE-R404A-9-N TUAE-R404A-9-NM TAE-R404A-T1-NM TAE-R404A-T2-NM TAE-R404A-T1-NM 419L L-3 TAE-R404A-T1-N TAE-R404A-T1-NM TAE-R404A-T2-NM TAE-R404A-T2-NM TAE-R404A-T2-NM 422L G-4 TAE-R404A-T2-N TAE-R404A-T2-NM TAE-R404A-T2-NM TAE-R404A-T3-NM TAE-R404A-T2-NM 527L G-4 TAE-R404A-T2-N TAE-R404A-T3-NM TAE-R404A-T3-NM TAE-R404A-T3-NM TAE-R404A-T3-NM 631L G-5 TAE-R404A-T3-N TAE-R404A-T3-NM TAE-R404A-T3-NM TAE-R404A-T3-NM TAE-R404A-T3-NM 103V L-1/2 TUAE-R404A-4-N TUAE-R404A-4-NM TUAE-R404A-5-NM TUAE-R404A-6-NM TUAE-R404A-6-NM 104V L-3/4 TUAE-R404A-5-N TUAE-R404A-5-NM TUAE-R404A-6-NM TUAE-R404A-7-NM TUAE-R404A-6-NM 105V L-1 TUAE-R404A-6-N TUAE-R404A-6-NM TUAE-R404A-6-NM TUAE-R404A-7-NM TUAE-R404A-7-NM 206V L-1 TUAE-R404A-7-N TUAE-R404A-7-NM TUAE-R404A-7-NM TUAE-R404A-8-NM TUAE-R404A-8-NM 208V L-1 1/2 TUAE-R404A-7-N TUAE-R404A-7-NM TUAE-R404A-8-NM TUAE-R404A-8-NM TUAE-R404A-8-NM 209V L-2 TUAE-R404A-8-N TUAE-R404A-8-NM TUAE-R404A-8-NM TUAE-R404A-9-NM TUAE-R404A-9-NM 312V L-2 TUAE-R404A-8-N TUAE-R404A-9-NM TUAE-R404A-9-NM TUAE-R404A-9-NM TUAE-R404A-9-NM 315V L-2 1/2 TUAE-R404A-9-N TUAE-R404A-9-NM TUAE-R404A-9-NM TAE-R404A-T1-NM TAE-R404A-T1-NM 416V L-2 1/2 TUAE-R404A-9-N TAE-R404A-T1-NM TAE-R404A-T1-NM TAE-R404A-T1-NM TAE-R404A-T1-NM 419V G-3 TAE-R404A-T1-N TAE-R404A-T1-NM TAE-R404A-T1-NM TAE-R404A-T2-NM TAE-R404A-T2-NM 523V G-4 TAE-R404A-T2-N TAE-R404A-T2-NM TAE-R404A-T2-NM TAE-R404A-T3-NM TAE-R404A-T3-NM 627V G-5 TAE-R404A-T3-N TAE-R404A-T3-NM TAE-R404A-T3-NM TAE-R404A-T3-NM TAE-R404A-T3-NM Above selections based on: 1) 100 F (38 ) vapor free liquid entering expansion valve 2) 110 F (43 ) ondensing temperature 3) 8-12 F (4.4-6.7 ) evaporator TD * Note: Pre-selected models based on these conditions T30--PDI-6-23 - 05/04/12

INSTALLATION The installation and start-up of evaporators should only be performed by qualified refrigeration mechanics. This equipment should be installed in accordance with all applicable codes, ordinances and local by-laws. INSPETION Inspect all equipment before unpacking for visible signs of damage or loss. heck shipping list against material received to ensure shipment is complete. IMPORTANT: Remember, you, the consignee, must make any claim necessary against the transportation company. Shipping damage or missing parts, when discovered at the outset, will prevent later unnecessary and costly delays. If damage or loss during transport is evident, make claim to carrier, as this will be their responsibility, not the manufacturer s. Should carton be damaged, but damage to equipment is not obvious, a claim should be filed for concealed damage with the carrier. IMPORTANT: The electrical characteristics of the unit should be checked at this time to make sure they correspond to those ordered and to electrical power available at the job site. Save all shipping papers, tags and instruction sheets for reference by installer and owner. APPLIATION evaporators are designed for walker-in cooler and freezer applications used with refrigerant R22 or R404A. For room temperatures above 35 F (2 ) AND evaporating temperatures above 26 F (-3 ), positive defrosting means (electric) may not be required, otherwise, electric defrost defrost models should be used. Electric defrost models come with defrost termination and fan delay as standard to control the defrost cycle termination and fan delay, while defrost initiation means (e.g. defrost timer) is not included. The coil must not be exposed to any abnormal atmospheric or acidic environments. This may result in corrosion to the cabinet and possible coil failure (leaks). (onsult manufacturer for optional baked on phenolic protective coatings). LOATION The unit location in the room should be selected to ensure uniform air distribution throughout the entire space to be refrigerated. Be sure that the product does not obstruct the free circulation of air. Allow a minimum of 24 clearance at each end. Do not locate evaporators over doors. onsideration should be given to the coil location in order to minimize the piping run length to the condensing unit and floor drain. INSTALLATION INSTRUTIONS EXPANSION VALVE (TXV) PRE-SELETED Locate the expansion valve bulb on a horizontal length of suction line preferably 3 to 6 inches from the suction header. Locate the bulb at 4 or 8 clock position and insulate with a waterproof type of insulation. lamp the bulb to ensure 100% contact of the bulb with the suction line. After following the manufacturer s installation instructions and after the room has reached the desired temperature the valve superheat should be checked. This will confirm that the evaporator is operating properly and performing to maximum efficiency. The superheat should be around 6 (3.3 O ) to 8 O F (4.4 O ) for a 10 to 12 O F T.D (5.6 to 6.7 O ). Too high or low a super heat will result in unsatisfactory system performance and possible compressor problems. MOUNTING Refer to dimensional drawing for recommended mounting arrangements. Ensure adequate clearance is provided behind the coil as well as each end. The evaporators may be mounted flush with ceiling with bolts, or hanging down with rod hangers. When using rod hangers, allow adequate space between the top of the unit and the ceiling for cleaning to comply with NSF Standard 7. Ensure that the ceiling is level since the drain pan has been sloped for drainage during the defrost cycle. DRAIN LINE The drain line should be run from the drain connection, sloping at least 1 (25 mm) per foot and should have the size at least as large as the drain connection. A P-Trap in a warm area outside the room must be provided to allow proper draining through the tubing. onnection should be made to proper drainage facilities that comply with local regulations. To prevent freeze-up when the temperature of the refrigerated space is 35 o F (2 ) or lower, the drain line should be heated along its run inside the cold room. The heated drain line should be insulated. It is recommended that the heater be energized at all times. A heat input of 20 watts per foot in a 28 F (-2 ) room and 30 watts per foot for -20 F (-29 ) rooms, is satisfactory. Drain line heaters are not required for constant room temperature above 35 F (2 ). Always trap evaporator drain line individually to prevent vapor migration. Ensure that the drain line has sufficient slope for proper drainage (prevention of ice build up/blockage in pan). T30--PDI-6-24 - 05/04/12

PIPING Refrigeration grade piping must be used for all field refrigeration piping. Refrigerant line sizes are important and may not be the same size as the coil connections. onsult ASHRAE handbook or other similar reference book for proper line sizing. Refrigerant piping and control system should be designed to prevent possible liquid slugging (from oil or refrigerant) of the compressors on start-up after the defrost cycle. Also, it should prevent oil logging and minimize refrigerant pressure drop. WIRING Wire system in accordance with governing standards and local codes. See data and wiring diagrams on pages 4 to 20 for typical wiring arrangement. Electrical wiring is to be sized in accordance with minimum circuit ampacity rating (MA). Size fuses used must not exceed the Maximum Fuse Size ratings. For ease of identifying the proper wiring terminal, unit wiring is color coded and terminal block connections are identified. When fan delay thermostats (combination fan delay and defrost termination) are installed, on start-up, the fans do not operate until the coil temperature is reduced to approximately 25 o F (-4 ). It is normal for the fans to cycle a few times until the room temperature is brought down. At higher evaporating temperatures this control may not close and therefore should either be by-passed temporarily or replaced with an adjustable type. (set for a higher temperature cut-in point). MAINTENANE The unit should be periodically inspected for any dirt or ice build-up on the fin surface and cleaned if necessary with a soft whisk or brush. Also ensure coils inner (and outer) drain pans do not have any ice build-up from improper defrost operation. When replacing heater elements first remove heater retainer brackets and heater clips. INSTALLATION INSTRUTIONS SYSTEM HEK Before Start-Up: 1. All wiring should be in accordance with local codes. 2. Refrigerant lines should be properly sized. 3. Thorough evacuation and dehydration has been performed. 4. The suction, discharge, and receiver service valves must be open. 5. The system preferably include a liquid line filter drier moisture indicator and suction filter. 6. Pour enough water into the drain pan to allow a good check on drainage and seal the trap. After Start-Up: 1. heck the oil level to be sure the oil charge is correct. 2. On initial start up the fans do not start until coil temperature is pulled down to approximately 25 F (-4 ) on the coil. Also, it is normal for the fan to cycle a few times until the room temperature is pulled down. 3. If necessary, temporarily by-pass fan delay control (to run fans until room temp is lowered). 4. Be sure that the expansion valve is properly set to provide the correct amount of superheat. 5. After the box temperature is close to reaching the desired temperature, the evaporator superheat must be checked and adjustment made if necessary. In general, evaporators running with a TD of 10 F (5.6 ) should have a superheat reading of 6 to 8 F (3.3 to 4.4 ). For evaporators with another T.D., the general rule is that the superheat should be around 60 to 80% of T.D. 6. Heavy moisture loads are usually encountered when starting the system for the first time. This may cause a rapid build-up of frost on the evaporator. During the initial pull down, we suggest that the frost build-up be watched and defrosted manually as required. 7. Observe that the system goes through at least one complete DEFROST YLE. T30--PDI-6-25 - 05/04/12

Miscellaneous GENERI SERVIE PARTS DESRIPTION PART # DESRIPTION PART # MOTOR 115V (PS) 1047778 TERMINAL BOARD: AIR DEFROST (115v, 208-230V) 1048825 MOTOR 208-230V (PS) 1047779 TERMINAL BOARD: AIR DEFROST (460V) 1045017 MOTOR 460V (PS) 1082684 INSULATOR, for 460V terminal board #1045017 171159 MOTOR 115V (E) 1090455 TERMINAL BOARD: ELETRI DEFROST (208- MOTOR 208-230V (E) 1090456 230V) 1070060 MOTOR MOUNT 1092340 TERMINAL BOARD: ELETRI DEFROST (460V) 1082728 BLADE (PS MOTOR) 1043667 HINGE ASSY #8820-16GA-2 X2 OP-STAINLESS BLADE (E MOTOR) 1087023 STEEL 160401 GUARD (PLASTI) 1081182 DRAIN FITTING 1085310 GUARD (WIRE) 1081272 LOKNUT - DRAIN FITTING 1081102 AORN NUT #N1/4-20 PANTONE GREY#429-1082950 GASKET - DRAIN FITTING 1081103 LOKNUT 1/4-20-UN for use with WIRE GUARD 1043768 HANGER BRKT LP 1081033 HEATER RETAINER LIP-OIL (WIRE LIP) 1081810 SREWS: #12 x 5/8 lg. 1081100 HEATER HOLD DOWN BRKT-DRAIN PAN 1081183 DELAY DETROST TERMINATION 1071280 HEATER SAFETY SWITH - ALL ED MODELS 1084158 Defrost Heaters MODELS OIL FAE HEATER (3 REQUIRED) PART NUMBER DRAIN PAN HEATER (1 REQUIRED) 208-230V 460V 208-230V 460V 104ME 104LE 103VE 269W / 1081185-001 269W / 1081186-001 253W / 1081187-011 253W / 1081188-001 106ME 105LE 104VE 269W / 1081185-001 269W / 1081186-001 253W / 1081187-011 253W / 1081188-001 107ME 106LE 105VE 269W / 1081185-001 269W / 1081186-001 253W / 1081187-011 253W / 1081188-001 209ME 207LE 206VE 495W / 1081185-002 495W / 1081186-002 408W / 1081187-012 408W / 1081188-002 211ME 209LE 208VE 495W / 1081185-002 495W / 1081186-002 408W / 1081187-012 408W / 1081188-002 214ME 211LE 209VE 495W / 1081185-002 495W / 1081186-002 408W / 1081187-012 408W / 1081188-002 317ME 314LE 312VE 721W / 1081185-003 721W / 1081186-003 564W / 1081187-013 564W / 1081187-013 320ME 317LE 315VE 721W / 1081185-003 721W / 1081186-003 564W / 1081187-013 564W / 1081188-003 423ME 419LE 416VE 947W / 1081185-004 947W / 1081186-004 719W / 1081187-014 719W / 1081188-004 426ME 422LE 419VE 947W / 1081185-004 947W / 1081186-004 719W / 1081187-014 719W / 1081188-004 532ME 527LE 523VE 1174W / 1081185-005 1174W / 1081186-005 875W / 1081187-015 875W / 1081188-005 639ME 631LE 627VE 1400W / 1081185-006 1400W / 1081186-006 1031W / 1081187-016 1031W / 1081188-006 Drain Pan Assemblies NUMBER OF S AIR DEFROST - MA MODELS ELETRI DEFROST - ME, LE & VE MODELS 1 1081011-002 1081011-001 2 1081012-002 1081012-001 3 1081013-002 1081013-001 4 1081014-002 1081014-001 5 1081015-002 1081015-001 6 1081016-002 1081016-001 Drain pan assemblies include drain fitting, hinge and heater hold down brackets when applicable. Drain pan assemblies do not include heaters or hot gas loops. T30--PDI-6-26 - 05/04/12

Finished Goods Warranty The terms and conditions as described below in the General Warranty Policy cover all products manufactured by National Refrigeration. GENERAL WARRANTY POLIY Subject to the terms and conditions hereof, the ompany warrants all Products, including Service Parts, manufactured by the ompany to be free of defects in material or workmanship, under normal use and application for a period of one (1) year from the original date of installation, or eighteen (18) months from the date of shipment from the ompany, whichever occurs first. Any replacement part(s) so supplied will be warranted for the balance of the product s original warranty. The part(s) to be replaced must be made available in exchange for the replacement part(s) and reasonable proof of the original installation date of the product must be presented in order to establish the effective date of the warranty, failing which, the effective date will be based upon the date of manufacture plus thirty (30) days. Any labour, material, refrigerant, transportation, freight or other charges incurred in connection with the performance of this warranty will be the responsibility of the owner at the current rates and prices then in effect. This warranty may be transferred to a subsequent owner of the product. THIS WARRANTY DOES NOT OVER (a) Damages caused by accident, abuse, negligence, misuse, riot, fire, flood, or Acts of God (b) damages caused by operating the product in a corrosive atmosphere (c) damages caused by any unauthorized alteration or repair of the system affecting the product s reliability or performance (d) damages caused by improper matching or application of the product or the product s components (e) damages caused by failing to provide routine and proper maintenance or service to the product (f) expenses incurred for the erecting, disconnecting, or dismantling the product (g) parts used in connection with normal maintenance, such as filters or belts (h) products no longer at the site of the original installation (i) products installed or operated other than in accordance with the printed instructions, with the local installation or building codes and with good trade practices (j) products lost or stolen. No one is authorized to change this WARRANTY or to create for or on behalf of the ompany any other obligation or liability in connection with the Product(s). There is no other representation, warranty or condition in any respect, expressed or implied, made by or binding upon the ompany other than the above or as provided by provincial or state law and which cannot be limited or excluded by such law, nor will we be liable in any way for incidental, consequential, or special damages however caused. The provisions of this additional written warranty are in addition to and not a modification of or subtraction from the statutory warranties and other rights and remedies provided by Federal, Provincial or State laws. System PROJET INFORMATION Model Number Serial Number Refrigerant Electrical Supply Date of Start-Up Service ontractor Phone Fax T30--PDI-6-27 - 05/04/12

AS BUILT SERVIE PARTS LIST Service Parts List Label To Be Attached HERE NATIONAL REFRIGERATION & AIR ONDITIONING ANADA ORP. 159 Roy Blvd. Brantford Ontario anada N3R 7K1 PHONE: (519) 751-0444 800-463-9517 FAX (519) 753-1140 www.t-rp.com Due to National Refrigeration s policy of continuous product improvement, we reserve the right to make changes without notice. 05/04/12