IRceL CH4 Methane (CH 4

Similar documents
4P75 CiTipeL Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

VQ500 Series Combustible Gas Detector Elements

IR15 Dual Gas Series Datasheet

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR25 Dual Gas Series Datasheet

Lamp Supply (Recommended)

IR1 Single Gas Series Datasheet

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

4) Intrinsic Safety Certification

Technical data sheet TDS0034

PREMIER PLATINUM INFRARED GAS SENSOR

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Technical data sheet TDS0060

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

P R O D U C T D ATA S H E E T

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Installation and Wiring 1.

Key Features. General Description

APPLICATION DATA SHEET

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Safe Operation Manual. Honeywell IQ Force Gas Detector

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

INSTRUCTION MANUAL (ATEX)

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Explosion-protected actuator Page 259 of 292

Tank Gauging System Special Safety Instruction

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Integrated IR Datasheet

E2S Datasheet v10a

Annubar Flowmeter Series

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Operation and Maintenance Manual

Dräger Polytron Pulsar 2 Open Path Gas Detector

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Model D12-IR. Digital Gas Transmitter...

icountms Range Fluid Condition Monitoring Moisture Sensors

THE BELGIAN PIONEER IN GAS DETECTION

ALTAIR 5X Multigas Detector Product Specification

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

SIMRAD GD10 IR GAS DETECTOR

VQ600 Series Combustible Gas Sensing Head

Guide for hazardous areas

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

VERSAFLOW VORTEX Supplementary instructions

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

Certificate of Compliance

1. GENERAL TECHNICAL INFORMATION

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

INSTRUCTION MANUAL (ATEX / IECEx)

testo 316-EX gas leak detector Instruction manual

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

GAS PLUS ALARM SYSTEM

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

INSTRUCTION MANUAL (ATEX / IECEx)

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Approvals, Certificates and Conditions

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Certificate of Compliance

Overview of Hazardous Locations as They Relate to Solenoid Valves

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Official Journal of the European Union

SENSOR O2 O2-A

HFID Heated Total Hydrocarbon Analyzer Module

IECEx Certificate of Conformity

SIMRAD GD10PE IR GAS DETECTOR

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

Explosion protection Marijan Gorše, dipl. ing.

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

Understanding Hazardous Locations Concepts

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

ExplorIR -W CO2 Sensor

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Transcription:

Product Datasheet IRceL CH4 Methane Sensor Document Purpose The purpose of this document is to present the performance specification of the IRceL CH4 Methane gas sensor. This document should be used in conjunction with the Operating Principles (OP17) and the Product Safety Datasheet (PSDS 21). The data provided in this document are valid at 20 C, 50% RH and 1013 mbar for 3 months from the date of sensor manufacture. Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles OP17. Doc. Ref.: ircelch4.innd Issue 5 ECN I 4769 Page 1 of 5

Key Features & Benefits: Integrated thermistor for accurate temperature compensation EEPROM programmed with sensor specfic performance characteristics Compact Size Technical Specifications Product Dimensions Operating Principle Measurement Range Accuracy (-20 C to +50 C) Response Time (T 90 )* Repeatability: Zero 5% CH 4 Linearity MEASUREMENT Non-Dispersive Infra-Red (NDIR) 0-5% vol. Methane Within ± (0.1% vol CH 4 + 4% of concentration) < 35 Seconds < ±0.015% CH 4 < ±0.05% CH 4 See Operating Principles OP17 ELECTRICAL Supply Voltage 3-5 VDC, 3.3 V to utilise EEPROM calibration Power Consumption <100 mw at 3.3 V Recommended Lamp Frequency 2 Hz, 50% duty cycle Minimum Resolution 0.03% CH 4 at zero 0.10% CH 4 at range Warm-up Time < 10 Seconds Housing Material Weight Orientation MECHANICAL Stainless Steel (see back page) 23 g Any All dimensions in mm All tolerances ±0.15mm unless otherwise stated Operating Temperature Range Operating Humidity Range Operating Pressure Range ENVIRONMENTAL -20 C to +50 C 0 to 99% RH (non-condensing) 700 to 1300 mbar with compensation LIFETIME Long Term Zero Drift < ±0.05% CH 4 per month Recommended Storage Temp -20 C to +50 C MTBF > 5 years Pin Function 1 Lamp Return 2 Lamp +5V 3 +5V Pyro Supply 4 Connector Output 5 Reference Output 6 Thermistat Output 7 0V Pyro Supply IMPORTANT NOTE: Connection should be made via PCB sockets only. Soldering to the pins will seriously damage your sensor. * Specifications are valid at 20 C, 50% RH and 1013 mbar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time. Doc. Ref.: ircelch4.innd Issue 5 ECN I 4769 Page 2 of 5

IRceL Cross Sensitivity IMPORTANT NOTE : The cross sensitivity data shown below does not form part of the product specification and is supplied for guidance only. Values quoted are based on tests conducted on a small number of sensors and any batch may show significant variation. For the most accurate measurements, an instrument should be calibrated using the gas under investigation. Methane sensor cross sensitivity 120 Methane sensor reading (%LEL) 100 80 60 40 20 0 Propane Pentane Butane Heptane Methanol Methane 0 5 10 15 % LEL of Test Gas Typical Response of IRceL CH4 to common Alkanes and Methanol. Note that cross sensitivity is device to device variable and temperature dependant. Doc. Ref.: ircelch4.innd Issue 5 ECN I 4769 Page 3 of 5

Product Approval Approval Body: UNDERWRITERS LABORATORIES INC Test Standard: UL913 CSA.C22.2 No 157 Product Categories: Class 1, Division 1, Groups A, B, C, D File Number: E180262 Approval Body: Test Standard: SIRA CERTIFICATION SERVICE EN 60079-0:2009 General Requirements EN 60079-1:2007 Flameproof Enclosures "d" EN 60079-31:2009 Explosive atmospheres. Equipment dust ignition protection by enclosure "t" Product Categories: Certificate Number: ExdI/IIC T4 (T amb -20 C to +55 C), Pmax = 1.4W MbGb ExtIIICT135 CIP6xDb II2GD/IM2 0518 Sira 04ATEX1084X Instructions specific to hazardous area installations (reference European ATEX Directive 94 / 9/ EC, Annex II, 1.0.6.) The following instructions apply to equipment covered by certificate number Sira 04ATEX1084X; 1. The equipment may be used with flammable gases and vapours with apparatus groups IIA, IIB and IIC and with temperature classifications T1, T2, T3 and T4. 2. The equipment is certified for use in ambient temperatures of -20ºC to +55ºC. 3. The equipment has not been assessed as a safety related device (as referred to by Directive 94 / 9 / EC Annex II, clause 1.5). 4. Installation of the equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice (e.g. EN 60079-14) 5. Inspection and maintenance of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice (e.g. EN 60079-17). 6. Repair of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice (e.g. EN 60079-19). 7. Special conditions for safe use 7.1. The IRceL is designed to be connected to a gas detector which shall provide an intrinsically safe supply and having a maximum output power (P max ) not greater than 1.4 watt. 7.2. Because the IRceL has not been proven to withstand the impact and drop tests prescribed in EN 60079-0:2009, clauses 26.4.2 and 26.4.3, additional protection shall be provided to ensure that it cannot be subjected to such mechanical stresses. Doc. Ref.: ircelch4.innd Issue 5 ECN I 4769 Page 4 of 5

8. The certification of this equipment relies upon the following materials used in its construction; Enclosure material: either 303 stainless steel, which contains less than 6% magnesium or 304 stainless steel, which contains less than 6% magnesium Flame arrester: 316 stainless steel mesh Cement: CW2248/HY956EN Manufacturer Ciba-Geigy Type of compound Epoxy resin Colour Beige (natural) Filler type and % 55.2% trihydrated Al 2 O 3 Other additives 8.3% Surface treatments None Temperature index 170 C City Tech reference RM 497 If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. Aggressive substances: e.g. acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. Suitable precautions: regular checks as part of routine inspections or establishing from the material's data sheet that it is resistant to specific chemicals. 9. The IRceL is available in several formats depending upon the optical filter and components employed. The Certification marking is shown below using the IRceL CH4 label as an example: SAFETY NOTE This sensor is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before each use of the sensor and/or instrument. Failure to carry out such tests may jeopardize the safety of people and property. Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company s policy of continued product improvement City Technology Limited reserves the right to make product changes without notice. The products are always subject to a programme of improvement and testing which may result in some changes in the characteristics quoted. As the products may be used by the client in circumstances beyond the knowledge and control of City Technology Limited, we cannot give any warranty as to the relevance of these particulars to an application. It is the clients responsibility to carry out the necessary tests to determine the usefulness of the products and to ensure their safety of operation in a particular application. Doc. Ref.: ircelch4.innd Issue 5 ECN I 4769 Page 5 of 5