Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Similar documents
Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data Ducted Three Phase Split System Air Conditioner

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Ducted Split System Air Conditioners Technical Data

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Ducted Split System Air Conditioners Technical Data

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

EC Motor Fan Coil Units. IMD-Y Series l/s

Packaged Air Conditioning Custom Build Solutions

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

EC Motor Fan Coil Units. IMDL-Y Series l/s

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

PRODUCT RANGE: ROOFTOP PACKAGE

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

OPA RKTG-P (ECO) c/w UC8 Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Condensing Units CUS 15-60

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

Remote Air Cooled Condensers C2 Series

Air Cooled Packaged Units

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

ROOFTOP PACKAGED AIR CONDITIONERS

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

Modular Air Cooled Scroll Chillers

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Roof top SPACE RPC 450Z R407C M011

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

PAJ3. Product Specifications

Water Cooled Air Conditioners Applications Manual

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Pool heating, efficiently

LZA High efficiency air to water heat pumps with HP compressor

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Ducted inverter reverse cycle air conditioning

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

R4H4. Product Specifications

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Braemar superior range of reverse cycle air conditioning

50TM TFF COMBINATION HEATING/COOLING UNITS

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

MAC N-407 Air-Cooled Chiller

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Air Cooled Chillers & Heat Pumps WinPACK HE-A

50TM COMBINATION HEATING/COOLING UNITS

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

MACH N-407 Heat Pump Air-Cooled Chiller

LZT High efficiency air to water heat pumps with E.V.I. compressors

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Kirby Commander Condensing Unit

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Roof top SPACE RPC 315Z R407C MA00

Commercial COMMERCIAL DUCTED. The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron.

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Commercial COMMERCIAL DUCTED. The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron.

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

EC Motor Fan Coil Units. IMDL-Y Series l/s

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

WALL-MOUNT HEAT PUMPS - (60HZ)

Heat Pump Air Conditioning Systems

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Product Data. Fig. 1 - Unit 50VR -A

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

GUIDE SPECIFICATIONS AQUARIUS ii

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

next DX.U.S* 052.Z2.H6.DC

Transcription:

Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013

, 340, 370 DUCTED PACKAGED ROOF TOP CONDITIONERS General This, 340 and 370 models are reverse cycle (heat pump) packaged roof top air conditioners designed and developed to comply with and exceed AS/NZS 3823. The systems have been successfully tested at 50 C ambient. Applications These units have been specifically developed for air conditioning of commercial premises, e.g. banks, offices, motels, shops, food outlets and restaurants. Air Flow Selection If the air returning to the indoor coil is regularly expected to be above 50%RH, then the coil face velocity should be limited to be 2.5 m/s or less (refer Air Handling graph). High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. Applications using full or high proportions of fresh air should be referred to your nearest temperzone sales office to establish the correct selection of units. Features Refrigerant R410A. Each complete system uses refrigerant R410A which is deemed to have zero ozone depletion potential. Economy. The /370 units have two independent refrigeration circuits to provide the flexibility and economy of two stage operation, i.e. utilising one or two circuits as conditions vary, plus the advantage of staggered starting. An economiser option is available to lower operating costs during the cooling cycle on all models. Efficient. Each unit incorporates high efficiency scroll compressors. Heat exchange coils incorporate inner grooved (rifled) tube for better heat transfer. Performance. An adjustable pulley on the indoor air fan motor enables fine tuning to match the supply air requirements. Each system includes a temperature sensing head pressure control which enables the system to compensate for outdoor ambient temperatures below 20 C on cooling cycle, and above 15 C on heating cycle. Quiet. Generous use of insulation also ensures a quiet unit. Insulation. Closed cell foam insulation has been used in the indoor air section to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 1530.3 (1989) and BS 476 parts 6 & 7. Durable. The cabinet is constructed from high grade galvanised steel - polyester powder coated (colour Grey) for all weather protection. External fasteners are stainless steel. The units include a polyester powder coated drain tray. Heat exchange coils comprise aluminium corrugated plate fins on mechanically expanded rifled copper tube. Both the indoor and outdoor air coil fins are epoxy coated for extra protection in corrosive environments, e.g. salt laden sea air. Coil protection guards are supplied. The has a louvred hail guard. Fan motor bearings are sealed for life so as not to incur regular maintenance. Self Diagnostics. The OPA's Outdoor Unit Controller (OUC)* has a display of LEDs to indicate faults and running conditions. A non-specific fault indicator is included for interface to external systems. * UC6 Controller on. Conrol Options. The is compatible with all BMS control systems via ethernet cable or internet, eg. Modbus, BACnet or LonWorks. Refer to temperzone for details. CONFIGURATIONS There is also choice of two supply air configurations: a. Horizontal supply/return air with box mounting channel (OPA RKTH), or b. Downward supply/return air with box mounting channel (OPA RKTU). (Note: Not yet available on.) Optional Equipment 1., 370: temperzone TZT- Controller kit, or SAT-2 (24V) Controller kit. : temperzone TZT- Wall Plaque for direct connection to UC6. 2. Filters (rated EU4). 3. Economiser (factory fitted) - includes dampers, weatherhood. 4. Manually adjustable fresh air damper and weatherhood. 5. Electronic control systems - available by special arrangement. 6. 6 kw Electric booster heat (factory fitted) complete with heater safety cutout required to meet AS/NZS 3350.2.40 1997. 7. BMS control adaptors for. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice switch prevents icing up of the outdoor coil during heating cycle. 5. Frost protection on cooling cycle. 6. Sensor fault indication. 7. Crankcase heater prevents liquid refrigerant condensing in the compressors during the 'off' cycle. 8. Compressor minimum run time to ensure oil return. 9. Phase rotation protection device. 10. 24V control circuit CompressorS Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. Refrigeration SYSTEM Each OPA unit is factory charged with HFC-410A (R410A) refrigerant. Accurator expansion devices control the flow of refrigerant. Wiring The electrical supply required (including voltage fluctuation limits) is: 3 phase 342-436 V a.c. 50 Hz with neutral and earth. The compressor crankcase heater requires a 24 hour power supply. A control panel, with 24V control circuit, is located in the outdoor unit and is fully wired ready to accept the main power supply. ECONOMISER OPTION If the outdoor air heat content or wet bulb temperature (dry bulb not recommended) is below that of the return air, the fresh air damper opens and the return air damper closes to provide the first stage of cooling. Operating costs are reduced as free cooling is obtained. (Note: A spill air facility in the building may be necessary for when the return air damper is closed.) Fresh air dampers close to a minimum setting and return air dampers open before normal compressor operation resumes. The manufacturer operates a quality management system that conforms to AS/NZS ISO 9001:2008. Also available: OPA 440 960 models (43 96 kw)

PERFORMANCE DATA MODEL INDOOR FAN SPEED l/s INDOOR COIL E.A.T. D.B. C W.B. C 21 15 23 17 27 19 31 21 21 15 23 17 27 19 31 21 21 15 23 17 27 19 Cooling Capacity (kw) Total = Total Capacity (kw) Sens. = Sensible Capacity (kw) E.A.T. = Entering Air Temperature = Nominal Capacity (kw) Note: Capacities are gross and do not include allowance for fan motor heat loss. COIL ENTERING TEMPERATURE C D.B. 23 27 31 35 39 43 Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. 28.9 229 28.6 22.8 27.7 22.4 26.4 21.7 24.7 20.5 22.5 18.9 30.5 22.3 30.1 22.3 29.3 22.0 28.0 21.3 26.2 20.2 24.0 18.7 32.0 25.6 31.6 25.6 30.8 25.2 29.5 24.5 27.8 23.3 25.6 21.7 33.5 30.3 33.1 30.3 32.3 29.9 31.0 29.1 29.3 27.8 27.1 26.0 33.4 26.4 33.0 26.4 32.0 25.9 30.5 25.0 28.5 23.7 26.0 21.8 35.2 25.8 34.7 25.8 33.8 25.4 32.3 24.6 30.3 23.3 27.8 21.6 36.9 29.6 36.5 29.6 35.5 29.1 34.0 28.3 32.1 26.9 29.5 25.1 38.7 35.0 38.3 35.0 37.3 34.6 35.8 33.6 33.8 32.1 31.3 30.1 38.4 30.3 37.9 30.3 36.8 29.8 35.1 28.8 32.8 27.2 29.9 25.1 40.4 29.7 39.9 29.6 38.8 29.2 37.1 28.2 34.8 26.8 31.9 24.9 42.5 34.0 42.0 34.0 40.9 33.5 39.1 32.5 36.9 31.0 34.0 28.9 31 21 44.5 40.2 44.0 40.3 42.9 39.8 41.2 38.6 38.9 36.9 36.0 34.6 Indoor Air Flow Correction Factors @ nominal conditions Indoor Air Flow (%) -20% -10% Rated +10% Total Capacity 0.95 0.975 1.0 1.025 Sensible Capacity 0.89 0.950 1.0 1.050 Reverse Cycle Systems MODEL 1600 1800 2 INDOOR ENTERING TEMP. C D.B. 15 20 25 15 20 25 15 20 25 heating capacity (kw) G = Gross Heating Capacity kw, based on nominal air flow. N = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw) outdoor coil ENTERING TEMPERATURE (e.a.t.) c d.b. 5 3 1 1 3 5 7 9 G N G N G N G N G N G N G N G N 18.6 16.8 20.1 18.1 21.5 19.2 22.9 19.7 24.3 20.8 26.1 24.8 27.8 27.8 29.2 29.2 18.3 16.4 19.8 17.8 21.1 18.8 22.5 19.3 23.8 20.4 25.6 24.3 27.2 27.2 28.6 28.6 17.6 15.8 19.0 17.1 20.3 18.1 21.6 18.6 23.0 19.6 24.7 23.2 26.2 26.2 27.5 27.5 20.6 18.5 22.3 20.0 23.8 21.2 25.4 21.8 26.9 23.0 28.9 27.4 30.7 30.7 32.3 32.3 20.2 18.2 21.8 19.7 23.3 20.8 24.9 21.4 26.4 22.5 28.3 26.9 30.1 30.1 31.6 31.6 19.4 17.5 21.0 18.9 22.5 20.0 23.9 20.6 25.4 21.7 27.3 25.6 29.0 29.0 30.5 30.5 25.8 23.2 27.9 25.1 29.9 26.6 31.8 27.3 33.7 28.8 36.2 34.4 38.5 38.5 40.5 40.5 25.3 22.8 27.4 24.7 29.3 26.1 31.2 26.8 33.1 28.3 35.5 33.7 37.8 37.8 39.7 39.7 24.4 21.9 26.4 23.7 28.2 25.1 30.0 25.8 31.8 27.2 34.2 32.1 36.4 36.4 38.2 38.2 l/s - Pa 820 RPM HANDLING Note: Airflows are for a dry coil. Reduce airflow by 5% in high moisture removal conditions. In a free blow or low resistance application, beware of exceeding indoor fan motor's full load amp limit (refer back page). As filters are optional, the fan air flows given are for units installed without filters. l/s - Pa 815 RPM 250 750 RPM 250 760 RPM AVAILABLE EXTERNAL PRESSURE (Pa) 200 680 RPM 150 50 1.5 kw MOTOR LIMIT 0 1300 1500 1700 1900 2 2300 FLOW (l/s) 2.0 m/s Face Velocity AVAILABLE EXTERNAL PRESSURE (Pa) 200 705 RPM 150 50 1.5 kw MOTOR LIMIT 0 1300 1500 1700 1900 2 2300 FLOW (l/s) 2.5 m/s Face Velocity

PERFORMANCE DATA l/s - Pa FILTERS - Pressure Drop Based on Koch Multi-Pleat HC filter. Max. final pressure drop 250 Pa. AVAILABLE EXTERNAL PRESSURE (Pa) 250 1.9kW 200 150 1.6kW 50 1.8kW 650 RPM 1.7kW 2.2kW 2.0kW 700 RPM 2.1kW 740 RPM 2.5kW 3 kw MOTOR LIMIT 0 1900 2000 2 2200 2300 2400 FLOW (l/s) 2.4 m/s Face Velocity PRESSURE DROP (Pa) 75 50 25 INITIAL (Clean Filter) 0 1.5 2.0 2.5 3.0 FILTER FACE VELOCITY (m/s) Model : Std Motor Size kw 1.5 1.5 3 Max. D.O.L. Motor kw 3.0 3.0 4.0 Max. Fan Speed RPM 1500 1400 850 Std Pulley Range RPM 660 820 660 820 650 850 Factory Setting RPM 725 725 750 SOUND LEVELS RADIATED MODEL FAN SPEED SWL db(a) 73 81 81 Sound Power Levels (SWL) Measured in decibels re 1 picowatt, at nominal airflow. OCTAVE BAND FREQUENCY Hz 125 250 500 1 k 2 k 4 k SOUND POWER LEVELS (SWL) db 80 73 68 68 62 60 82 79 79 76 71 64 82 79 79 76 71 64 Sound Pressure Levels (SPL) Measured in decibels re 20 µpa, at nominal airflow. MODEL FAN SPEED SPL @ 3 m db(a) 57 65 65 OCTAVE BAND FREQUENCY Hz 125 250 500 1 k 2 k 4 k SOUND PRESSURE LEVELS (SPL) db 64 57 52 52 46 44 66 63 63 60 55 48 66 63 63 60 55 48 OUTLET MODEL INDOOR FAN SPEED 680 RPM 750 RPM 820 RPM 760 RPM 740 RPM SWL db(a) 74 81 82 87 87 Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. OCTAVE BAND FREQUENCY Hz 125 250 500 1 k 2 k 4 k SOUND POWER LEVELS (SWL) db 71 69 72 69 67 65 75 73 78 76 73 71 75 74 79 78 75 73 82 81 83 83 80 77 82 81 83 83 80 77

DIMENSIONS (mm) Fig. 1 RKTBH Horizontal Supply & Return Air Not to Scale PROJECTION 55 1670 55 W X 1490 RETURN POINT Loads (kg) W X Y Z 121 119 176 Note : A 2 m clearance is required above the exhaust air fans Z ELECTRICAL BOX 0 MIN. CLEARANCE 2000 MIN. CLEARANCE Y FILTER 105 440 420 95 600 60 1500 405 770 540 265 88 1605 MOUNTING CENTRES 1780 O/A DRAIN 1" BSP FEMALE 35 1402 MOUNTING CENTRES Fig. 2 RKTBH Horizontal Supply & Return Air 1950 55 FLOW FRESH COWL 0 MIN. CLEARANCE 1625 U V W RETURN 0 MIN. CLEARANCE FOR FILTER POINT Loads (kg) U V W X Y Z 110 96 82 106 115 122 Note : A 2 m clearance is required above the exhaust air fans. Z Y X FLOW 60 FILTER 145 155 383 390 525 FRESH COWL 1500 456 675 515 310 941 MTG CTR 2058 O/A 941 MTG CTR DRAIN 1" BSP FEMALE 1554 MOUNTING CENTRES 35 DRAIN 1" BSP FEMALE

Fig. 3 RKTBH Horizontal Supply & Return Air 1970 55 FLOW U V W 0 MIN. CLEARANCE 1685 RETURN 0 MIN. CLEARANCE FOR FILTER POINT Loads (kg) U V W X Y Z 110 105 101 111 115 120 Note : A 2 m clearance is required above the exhaust air fans. Z Y X FLOW 60 FILTER 42 155 490 420 95 600 1555 535 772 565 340 953 MTG CTR 2080 O/A 953 MTG CTR DRAIN 1" BSP FEMALE 1613 MOUNTING CENTRES 35 Fig. 4 Downward Supply & Return Air OPA RKTBU R S MODEL R S T U V W X T 745 110 180 375 140 240 405 745 155 440 180 115 482 365 Note: Downward version not yet available on U V Note: Refer to Fig.1 or 2 for overall dimensions and clearances. X W 60 & RETURN NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Certified data is available on request.

Fig. 5 /370 Economiser Option INDOOR SECTION MOTORISED FRESH DAMPER 600 FRESH INTAKE 250 mm MINIMUM ROOF RETURN MOTORISED RETURN DAMPER Fig. 6 /370 Fresh Air Damper Option ADJUSTABLE FRESH DAMPER 335 FRESH INTAKE NOMENCLATURE O P A 2 9 4 R K T B H e.g. Series Size Type O - Outdoor P - Packaged A - Air Cooled Divide by 10 to get approx. nominal Capacity in kilowatts R - Reverse cycle K - Refrigerant R410A T - Three phase power supply B - Twin compressor system (twin circuit) H - Horizontal discharge supply air fan U - Downward discharge supply air fan P - Plug fan c/w EC motor Z - Economiser

SPECIFICATIONS Model opa 294RKTB RKTB RKTB Nominal Cooling Capacity * 1 kw 29.5 34.0 39.1 Net Cooling Capacity kw 28.3 32.5 36.9 Heating Capacity * 2 kw 27.2 30.1 35.6 EER / AEER (Cooling) 3.21 / 3.20 3.31 / 3.29 3.23 / 3.22 Air Flow * 3 l/s 1600 1800 2 Power Source * 4 3 phase 342 436 V a.c. 50 Hz Indoor Fan Full Load Amps A/ph. 3.1 4.6 6.2 Running Amps (Total System) A/ph. 18 / 15 / 15 17 / 20 / 17 24 / 20 / 20 Max. Running Amps (Total Sys.) A/ph. 23 25 31 Finish Grey polyester powder coat Net Weight kg 516 631 662 Shipping Weight (approx.) kg 595 740 775 Notes: * 1 Nominal Cooling Capacity at AS/NZS 3823 conditions: Indoor Entering Air Temperature 27 C D.B., 19 C W.B.; Outdoor Entering Air Temperature 35 C D.B. Net Cooling Capacity at AS/NZS 3823 includes an allowance for indoor fan motor heat loss. * 2 Heating Capacity (reverse cycle units only) at AS/NZS 3823 conditions: Indoor Entering Air Temperature 21 C D.B.; Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Power source includes voltage limits. Available from temperzone limited Head Office, Auckland : 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Website: www.temperzone.biz temperzone australia pty ltd Head Office, Sydney : 14 Carnagie Place, Blacktown, NSW 2148 PO Box 8064, Seven Hills West, NSW 2147, AUSTRALIA. Email sales@temperzone.com.au AUCKLAND SYDNEY Ph. 0-9-279 5250 Ph. (02) 8822-5700 Fax 0-9-275 5637 Fax (02) 8822-5711 WELLINGTON ADELAIDE Ph. 0-4-569 3262 Ph. (08) 8340-0607 Fax 0-4-566 6249 Fax (08) 8340-2118 CHRISTCHURCH SINGAPORE Ph. 0-3-379 3216 Ph. SNG 6733 4292 Fax 0-3-379 5956 Fax SNG 6235 7180 MELBOURNE Ph. (03) 8769-7600 Fax (03) 8769-7601 BRISBANE Ph. (07) 3308-8333 Fax (07) 3308-8330 NEWCASTLE Ph. (02) 4962-1155 Fax (02) 4961-5101 PERTH Ph. (08) 9314-3844 Fax (08) 9314-3855 TOWNSVILLE Ph. (07) 4773-9566 Fax (07) 4773-9166 HOBART Ph. (03) 6331-4209 Fax (03) 6333-0224 10/13 Pamphlet No. 3916a temperzone limited 2013