B. Shop Drawings: Include diagrams for power, signal, and control wiring.

Similar documents
B. Shop Drawings: Include diagrams for power, signal, and control wiring.

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. Section Joint Sealants: Seal fixtures to walls and floors.

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

SECTION PLUMBING FIXTURES

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

A. This Section includes the following emergency plumbing fixtures:

A. This Section includes the following domestic water piping specialties:

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN AND CONSTRUCTION STANDARDS July 2011

SECTION PLUMBING

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

University of Rochester October 17, 2008 Brooks Landing Business Center

SECTION DOMESTIC WATER PIPING SPECIALTIES

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Lasco # Description Picture Lasco # Description Picture

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

This Product MasterSpec Section is licensed by AVITRU, LLC to Haws Corporation ("Licensee").

CHILD DEVELOPMENT & LITERACY CENTER H17-N104-CB SGA 17002

2. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

B. Product Schedule: For appliances. Use same designations indicated on Drawings.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

DOMESTIC WATER PACKAGED BOOSTER PUMPS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Willoughby Industries - Security Products

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

GENERAL PLUMBING REQUIREMENTS

SECTION DRY-PIPE SPRINKLER SYSTEMS

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

SECTION ELECTRIC WATER HEATERS

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION (15530) - REFRIGERANT PIPING

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

University of Missouri St. Louis UMSL Project #S7628 Campus Police Building Building Modifications & Renovations R&B Project # Building Upgrades

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

SECTION ELECTRIC WATER HEATERS

PROJ. NO SECTION REFRIGERANT PIPING

University of New Hampshire Scholars' Repository

TOILET HANDLE STYLE FINISHES AVAILABLE: CLASSIC LEVERS: WHITE CHROME PLATED PVD BRASS PLATED SATIN NICKEL ELITE STYLE LEVERS: WHITE CHROME PLATED

SECTION PLUMBING SPECIALTIES

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

PLUMBING FIXTURES CHAPTER 27

FIRE SUPPRESSION SPRINKLER SYSTEM

Construction Standards Page

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

PLUMBING FIXTURES Reserved

CLINICAL SERVICES ADMINISTRATION (214)

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DOMESTIC WATER PIPING SYSTEMS. 0. Pipe and pipe fittings are specified in the following sections:

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

SECTION FIRE EXTINGUISHER CABINETS

ARCHERTM ORDERING INFORMATION NOTES T01-C INSTALLATION INSTRUCTIONS VITREOUS CHINA ONE-PIECE TOILET K-3639T/K-3639T-C

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

GENERAL PLUMBING REQUIREMENTS

SECTION SPRINKLER SYSTEMS

Hinesville First United Methodist Church SECTION RESIDENTIAL APPLIANCES

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

PRICE BOOK CONTENTS 010 PIPE

SECTION (15530) - REFRIGERANT PIPING

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

B. Related Sections: The following Sections contain requirements that relate to this Section.

NATURAL GAS PIPING

PARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW

TROCADERO ORDERING INFORMATION NOTES T01-H INSTALLATION INSTRUCTIONS

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

The Water Efficiency Company. Vitreous China Fixtures

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

SECTION WET-PIPE SPRINKLER SYSTEMS

Karess ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS

Transcription:

SECTION 224213.13 - COMMERCIAL WATER CLOSETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Water closets. 2. Flushometer valves. 3. Toilet seats. B. Related Requirements: 1. Section 224100 "Residential Plumbing Fixtures" for residential water closets. 2. Section 224300 "Medical Plumbing Fixtures" for healthcare water closets. 3. Section 224600 "Security Plumbing Fixtures" for security water closets. 1.3 ACTION SUBMITTALS A. Product Data: For each type of product. 1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for water closets. 2. Include rated capacities, operating characteristics, electrical characteristics, and furnished specialties and accessories. B. Shop Drawings: Include diagrams for power, signal, and control wiring. 1.4 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For electronic sensors to include in operation and maintenance manuals. 1.5 MAINTENANCE MATERIAL SUBMITTALS A. Furnish extra materials that are packaged with protective covering for storage and identified with labels describing contents. COMMERCIAL WATER CLOSETS 224213.13-1

1. Flushometer-Valve Repair Kits: Equal to 10 percent of amount of each type installed, but no fewer than one of each type. PART 2 - PRODUCTS 2.1 FLOOR-MOUNTED, BOTTOM-OUTLET WATER CLOSETS A. Water Closets WC-1: Floor mounted, bottom outlet, top spud. product by one of a. American Standard America. b. Crane Plumbing, L.L.C. c. Ferguson Enterprises, Inc.; ProFlo Brand. d. Kohler Co. e. Mansfield Plumbing Products LLC. f. Zurn Industries, LLC; Commercial Brass and Fixtures. 3. Bowl: a. Standards: ASME A112.19.2/CSA B45.1 and ASME A112.19.5. b. Material: Vitreous china. c. Type: Siphon jet. d. Style: Flushometer valve. e. Height: Handicapped/elderly. f. Rim Contour: Elongated. g. Water Consumption: 1.28 gal. per flush. h. Spud Size and Location: NPS 1-1/2 top. i. Color: White. 4. Bowl-to-Drain Connecting Fitting: ASME A112.4.3. 5. Flushometer Valve: Zurn. 6. Toilet Seat: Church. B. Water Closets WC-2: Floor mounted, bottom outlet, back spud. product by one of COMMERCIAL WATER CLOSETS 224213.13-2

a. American Standard America. b. Crane Plumbing, L.L.C. c. Ferguson Enterprises, Inc.; ProFlo Brand. d. Kohler Co. e. Mansfield Plumbing Products LLC. f. Zurn Industries, LLC; Commercial Brass and Fixtures. 3. Bowl: a. Standards: ASME A112.19.2/CSA B45.1 and ASME A112.19.5. b. Material: Vitreous china. c. Type: Siphon jet. d. Style: Flushometer valve. e. Height: Handicapped/elderly. f. Rim Contour: Elongated. g. Water Consumption: 1.28 gal. per flush. h. Spud Size and Location: NPS 1-1/2 top. i. Color: White. 4. Bowl-to-Drain Connecting Fitting: ASME A112.4.3. 5. Flushometer Valve: Zurn. 6. Toilet Seat: Church. 2.2 FLUSHOMETER VALVES A. Battery-Powered, Solenoid-Actuator, Piston Flushometer Valves : product by one of a. Coyne & Delany Co. b. Gerber Plumbing Fixtures LLC. c. Hydrotek International, Inc. d. Kohler Co. e. Moen Incorporated. f. Sloan Valve Company. g. TOTO USA, INC. h. Zurn Industries, LLC; Commercial Brass and Fixtures. 3. Standard: ASSE 1037. 4. Minimum Pressure Rating: 125 psig. 5. Features: Include integral check stop and backflow-prevention device. 6. Material: Brass body with corrosion-resistant components. 7. Exposed Flushometer-Valve Finish: Chrome plated. 8. Panel Finish: Chrome plated or stainless steel. COMMERCIAL WATER CLOSETS 224213.13-3

9. Style: Exposed. 10. Actuator: Solenoid complying with UL 1951, and listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. 11. Trip Mechanism: Battery-powered electronic sensor complying with UL 1951, and listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. 12. Consumption: 1.28 gal. (4.8 L) per flush. 13. Minimum Inlet: NPS 1. 14. Minimum Outlet: NPS 1-1/4. 2.3 TOILET SEATS A. Toilet Seats: product by one of a. American Standard America. b. Bemis Manufacturing Company. c. Centoco Manufacturing Corporation. d. Church Seats. e. Kohler Co. f. Olsonite Seat Co. g. TOTO USA, INC. 3. Standard: IAPMO/ANSI Z124.5. 4. Material: Plastic. 5. Type: Commercial (Standard). 6. Shape: Elongated rim, open front. 7. Hinge: Check. 8. Hinge Material: Noncorroding metal. 9. Seat Cover: Not required. 10. Color: White. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine roughing-in of water supply and sanitary drainage and vent piping systems to verify actual locations of piping connections before water-closet installation. B. Examine walls and floors for suitable conditions where water closets will be installed. C. Proceed with installation only after unsatisfactory conditions have been corrected. COMMERCIAL WATER CLOSETS 224213.13-4

3.2 INSTALLATION A. Water-Closet Installation: 1. Install level and plumb according to roughing-in drawings. 2. Install floor-mounted water closets on bowl-to-drain connecting fitting attachments to piping or building substrate. 3. Install accessible, wall-mounted water closets at mounting height for handicapped/elderly, according to ICC/ANSI A117.1. B. Support Installation: 1. Install supports, affixed to building substrate, for floor-mounted, back-outlet water closets. 2. Use carrier supports with waste-fitting assembly and seal. 3. Install floor-mounted, back-outlet water closets attached to building floor substrate, onto waste-fitting seals; and attach to support. 4. Install wall-mounted, back-outlet water-closet supports with waste-fitting assembly and waste-fitting seals; and affix to building substrate. C. Flushometer-Valve Installation: 1. Install flushometer-valve, water-supply fitting on each supply to each water closet. 2. Attach supply piping to supports or substrate within pipe spaces behind fixtures. 3. Install lever-handle flushometer valves for accessible water closets with handle mounted on open side of water closet. 4. Install actuators in locations that are easy for people with disabilities to reach. 5. Install fresh batteries in battery-powered, electronic-sensor mechanisms. D. Install toilet seats on water closets. E. Wall Flange and Escutcheon Installation: 1. Install wall flanges or escutcheons at piping wall penetrations in exposed, finished locations and within cabinets and millwork. 2. Install deep-pattern escutcheons if required to conceal protruding fittings. 3. Comply with escutcheon requirements specified in Section 220518 "Escutcheons for Plumbing Piping." F. Joint Sealing: 1. Seal joints between water closets and walls and floors using sanitary-type, one-part, mildew-resistant silicone sealant. 2. Match sealant color to water-closet color. 3. Comply with sealant requirements specified in Section 079200 "Joint Sealants." 3.3 CONNECTIONS A. Connect water closets with water supplies and soil, waste, and vent piping. Use size fittings required to match water closets. COMMERCIAL WATER CLOSETS 224213.13-5

B. Comply with water piping requirements specified in Section 221116 "Domestic Water Piping." C. Comply with soil and waste piping requirements specified in Section 221316 "Sanitary Waste and Vent Piping." D. Where installing piping adjacent to water closets, allow space for service and maintenance. 3.4 ADJUSTING A. Operate and adjust water closets and controls. Replace damaged and malfunctioning water closets, fittings, and controls. B. Adjust water pressure at flushometer valves to produce proper flow. C. Install fresh batteries in battery-powered, electronic-sensor mechanisms. 3.5 CLEANING AND PROTECTION A. Clean water closets and fittings with manufacturers' recommended cleaning methods and materials. B. Install protective covering for installed water closets and fittings. C. Do not allow use of water closets for temporary facilities unless approved in writing by Owner. END OF SECTION 224213.13 COMMERCIAL WATER CLOSETS 224213.13-6