Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Similar documents
Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

PAJ3. Product Specifications

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp.

13 SEER PACKAGE GAS / ELECTRIC UNIT (575V -3 Ph -60Hz) 36 to 61 MBtuh

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

C13-Series Engineering Guide

PAR5. Product Specifications

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

WJH4 Product Specifications

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Advanced Product Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Commercial High-Efficiency Condensing Units

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

VertiCool Aurora Engineering Guide

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

Commercial High-Efficiency Condensing Units

Product Data. Fig. 1 - Unit 50VG -A

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

MAC N-407 Air-Cooled Chiller

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

ASHRAE 90.1 EFFICIENCY PACKAGE GAS / ELECTRIC UNIT MBtuh

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION

50TM COMBINATION HEATING/COOLING UNITS

High Heat COP. High/Low Stage

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

WPH4 Product Specifications

PHD3. Product Specifications

50TM TFF COMBINATION HEATING/COOLING UNITS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PGS SERIES 15 to 20 Ton

STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT MBtuh

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Ruud Commercial Achiever Series Package Gas Electric Unit

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HJ Single-Package Rooftop High-Efficiency Electric Cooling Units. 3 to 12 1 / 2 Nominal Tons

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Installation, Start-Up and Service Instructions

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Roof Top Packaged Unit (RTU-1) Specification

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

RGE 13 A T - 1 A

Advance Release September 2009

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Model 581B Sizes to12 1 2Tons

MAC-120HE-03 Air-Cooled Chiller

50TJM 60Hz Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons

Transcription:

007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option), combining installation flexibility with efficient performance. Features / Benefits Higher Cooling Capacity. Standard cooling operation at outdoor ambient temperature as high as 50 C (122 F). Galvanized steel cabinet with powder paint coat. 2-inch (51 mm) return-air filters. Commercial strength base rails (full perimeter). Corrosion-resistant sloped condensate pan. Single power entry to the unit. Commercial duty motors with permanently lubricated bearings. All units feature sloped condensate drain pans in accordance with ASHRAE Standard 62. Also, the new sloped condensate pan permits either an external drain (outside the roof curb) or an internal bottom drain (inside the roof curb). Both options require an external, field supplied disconnect, if desired. Field installed electrical heaters are available in a wide range of capacities. Singe point wiring kit makes installation simple. Simple electrical connections: Terminal boards, located in the base unit control box, facilitate connections to room thermostat, outdoor thermostat (s), economizer, and electrical heat permitting easy servicing. Thru-the-curb service connections accessory allow power and control wiring to be routed through the curb, minimizing roof penetrations. Both power and control connections are made on the same side of the unit to simplify installation. Quite and efficient operation is provided by belt-driven evaporator fans. The belt-driven evaporator fan with variable pitch pulleys allows adjustment to available static pressure to meet the job requirements of even the most demanding applications. -04 PD 50Hz 2011

Model Number Nomenclature 50 TJ S 008 9 3 3 SR 50 Cooling Only/Cooling with Optional Electric Heat (Field Installed) LJ Size 007 & 008. TJ Size 008-014. NE Standard Unit, 50LJS Series. SR Standard Unit, Series. Packaging 1 Standard. 3 Export. S -High Ambient Design Series 3 With Fixed Orifice Expantion. Nominal Capacity in Tons (kw) 50LJS007-6 Tons (21 kw) 50LJS008-6.5 Tons (23 kw) Voltage 008-7 Tons (24.6 kw) 9 400/420-3-50 009-9 Tons (31.7 kw) 012-10 Tons (35 kw) Coil Fin Option 014-12 Tons (44 kw) AL Evaporator, AL Condenser. P Pre-Coated Condenser Coil ( Aluminum Fins ). LEGEND AL Aluminum

AHRI Capacity Rating* UNIT NOMINAL TONS STANDARD CFM GROSS COOLING CAPACITY (Btuh) Bels - Sound Levels (1 bel = 10 decibels) EER - Energy Efficiency Ratio *AHRI - Air Conditioning, Heating and Refrigeration Institute. NET COOLING CAPACITY (Btuh) TOTAL kw EER SOUND RATING (Bels) 50LJS007 6 2200 67,600 65,000 6.6 9.8 8.4 50LJS008 6.5 2200 78,600 76,000 7.05 10.8 8.4 008 7 2800 85,300 82,200 9.8 8.4 8.6 009 9 3000 106,600 103,200 10.9 9.5 8.6 012 10 4000 122,500 118,350 13.4 8.8 8.8 014 12 4750 146,700 138,050 14.1 9.8 8.8 1. Rated in accordance with ARI Standards 210/240-89 or 360-86 and 270-84. 2. Net values reflecting the effects of circulating fan heat. 3. Ratings are based on: Cooling Standard: 80 F db, 67 wb indoor entering-air temperature and 95 F db air entering outdoor unit, Horizontal Discharge, 0.4 iwg External Static.

Physical data (50 Hz) English UNIT MODEL LJS007 LJ008 TJS008 TJS009 TJS012 TJS014 Electrical Configuration V-PH-Hz 400-3 50 (+/- 10%) Nominal Cooling Capacity OPERATING WEIGHT TR 6 6.5 7.0 9.0 10 12.0 Kbtu/hr 72 78 84 108 120 144 Unit lbs 520 529 755 760 915 930 Economizer lbs 34 44 Roof Curb lbs 115 143 COMPRESSOR type Scroll Hermetic, Reciprocating Scroll Quantity no. 1 2 Oil (per compressor) oz 53 53 55 65 53 REFRIGERANT type R -22 Operating Charge Circuit 1 lbs-oz 8-0 9-6 5-4 6-3 6-5 7-12 Circuit 2 lbs-oz - - 5-4 6-3 6-5 7-12 CONDENSER FAN type Propellar Quantity. Diameter no.in. 1. 26 2. 22 Nominal CFM CFM 4300 8650 8650 9225 9225 Motor* hp rpm hp rpm 1/3.960 1/3. 1100 CONDENSER COIL type Enhanced Copper Tubes, Aluminum Double-Wavy Fins Rows Fins/inch no.per in. 2 17 1 17 2 17 Total Face Area sq. ft 12.25 13.1 20.5 18 17.42 25 EVAPORATOR FAN type Centrifugal Type Quantity. Size no.in. 1 10 x 10 1. 15 x15 Drive Type type Belt Driven Nominal CFM CFM 2200 2800 3000 4000 4750 Input Watts @ Nominal CFM Watts 800 900 1000 1500 2000 Motor** hp, rpm hp, rpm 1.5, 1425 2, 1425 3, 1425 Max. Continuous Bhp hp 2.4 2.4 2.9 3.7 Motor Pulley Pitch Dia. in. 4.4 3.4 4.4 5 Fan Pulley Pitch Dia. in. 5.19 5.5 7 EVAPORATOR COIL type Enhanced Copper Tubes, Aluminum Double-Wavy Fins Rows Fins / inch no per in. 4 15 3.15 4. 15 Total Face Area sq. ft 5.5 8 10 11.1 HIGH PRESSURE SWITCH Psig Standard Compressor IPRV setting Cutout / Reset (Auto) LOW PRESSURE SWITCH Psig Cutout / Reset (Manual) 27 / 44 FREEZE-PROTECTION SWITCH Opens / Closes * Condenser Motor Efficiency: 80%. **Evaporator Motor Efficiency: LJS007,008 = 81%. TJS008-014 = 85%. 0 F OUTDOOR AIR INLET SCREENS type Cleanable (With Optional Economizer) Quantity. Size no.in. 1.20x24x1 1 20x25x1 + 1.16x25x1 RETURN AIR FILTERS type Throw away Quantity. Size no.in. 2.16x25x2 4. 16x20x2 4 20x20x2 426 320 30 ± 5 / 45 ± 5

Electrical Data 50LJS007,008, 008 014 ( 50 Hz ) UNIT MODEL 50LJS 007 50LJS 008 008 009 012 014 NOMINAL V-Ph-Hz IFM TYPE VOLTAGE RANGE COMPRESSOR (ea) OFM (ea) IFM ELECTRIC HEAT* POWER SUPPLY DISCONNECT SIZE MIN MAX RLA LRA Qty Hp FLA FLA NOMINAL KW** FLA MCA MOCP FLA LRA - - 16.9 25 -- 4.2 6.1 16.9 25 -- 400-3-50 STD 342 440 10.3 100 1 1/3 1.6 2.4 8 11.5 18.4 30 -- 9.7 14 21.5 35 -- -- 16 23.2 33.0 55 -- 17.7 25.6 36.0 60 -- - - 17.8 25 -- 4.2 6.1 17.8 25 -- 400-3-50 STD 342 440 11 8 7 1 1/3 1.6 2.4 8 11.5 18.4 30 -- 9.7 14 21.5 35 -- -- 16 23.2 33 55 -- 17.7 25.6 36 60 -- 400-3-50 STD 342 440 6.6 53 2 1/2 1.8 3.4 400-3-50 STD 342 440 7.5 62 2 1/2 1.8 3.4 400-3-50 STD 342 440 9 82 2 1/2 1.8 3.4 400-3-50 STD 342 440 12 100 2 1/2 1.8 4.8 - - 18.8 20 19 9.7 13.9 21.7 20 19 11.5 16.5 24.9 25 22 19.3 27.8 39.1 40 35 22.9 33.1 45.6 45 41 29 41.8 56.5 60 51 - - 21.5 25 21 9.7 13.9 21.7 25 21 11.5 16.5 24.9 25 22 19.3 27.8 39.1 40 35 22.9 33.1 45.6 45 41 29 41.8 56.5 60 51 - - 23.2 30 24 9.7 16.5 23.9 30 24 19.3 27.8 38.1 40 35 22.9 33.1 44.6 45 41 29 41.8 55.5 60 51 34.7 50.1 65.9 70 61 - - 33.3 40 35 11.5 18 33.3 40 35 19.3 30.3 43.9 45 40 22.9 36.1 51.1 60 47 29 45.5 62.8 70 58 34.7 54.6 74.2 80 68 130 147 158 232 LEGEND AND NOTES FOR ELECTRICAL DATA TABLES LEGEND FLA Full Load Amps HACR Heating, Air Conditioning and Refrigeration IFM Indoor (Evaporator) Fan Motor LRA Locked Rotor Amps MCA Minimum Circuit Amps MOCP Maximum Overcurrent Protection NEC National Electrical Code OFM Outdoor (Condenser) Fan Motor RLA Rated Load Amps *Heater capacity (kw) is based on heater voltage of 208 v, 240 v, 480 v, and 600 v. Heaters are rated at 240 v, 480 v, or 600 v. If power distribution voltage to unit varies from rated heater voltage, heater kw will vary accordingly. To determine heater capacity at actual unit voltage, multiply 240 v, 480 v, or 600 v capacity by multipliers found in table on page 51. Used to determine minimum disconnect size per NEC. **Heaters are field installed only. Fuse or HACR circuit breaker. Fusing in single point box provides the required branch circuit protection. NOTES: 1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker. The Canadian units may be fuse or circuit breaker. 2. Unbalanced 3-Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance. % Voltage Imbalance max voltage deviation from average voltage = 100 x average voltage Example: Supply voltage is 460-3-60. AB = 452 v BC = 464 v AC = 455 v 452 + 464 + 455 Average Voltage = 3 1371 = 3 = 457 Determine maximum deviation from average voltage. (AB) 457 452 = 5 v (BC) 464 457 = 7 v (AC) 457 455 = 2 v Maximum deviation is 7 v. Determine percent of voltage imbalance. 7 % Voltage Imbalance = 100 x 457 = 1.53% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

Base unit dimensions 50LJS007,008

Base unit dimensions 008-014