FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

Similar documents
FIREMASTER CONCERTINA TM

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

FIRE & SMOKE CURTAINS

FIRE & SMOKE CURTAINS

PRODUCT SPECIFICATION FireMaster Plus Concertina

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

PRODUCT SPECIFICATION FireMaster Plus

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

PRODUCT SPECIFICATION FireMaster Concertina

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

A REVOLUTIONARY APPROACH TO FIRE SAFETY

CI/Sfb ( ) smoke stop. Smoke Barriers for all applications... Swiss Re London. Lane Crawford Singapore. London.

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

Smoke and Fire Curtains

The Passive Fire Protection Handbook

Firetex steel fire shutters

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

Dublin airport - Dublin, Ireland

The Passive Fire Protection Handbook

TILT AND SLIDE WINDOW

Disabled persons toilet alarm kit from Cameo Systems

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Fixing points M6 (1/4 )

The Downs Portsdown Hill Road Cosham

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Fire and Smoke Curtains

FM MEDICOL. Cableflow International Limited. The FLUSH MEDICOL (FM) Patient Care Services. Column has evolved from a market requirement for a

PANEL. Cableflow International Limited

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

fire resistance testing

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

Conventional & Twin-wire Fire System

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments.

HART XL High Sensitivity Smoke Detection

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

Evacuate everyone Sonos Pulse & Nexus Pulse

Passenger Lifts: finishes & options. A guide to the wide variety of finishes and options available on our passenger lifts

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

Welcome to the. Firestop Seminar. Hilti Technical and Engineering Support

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Aspirating Smoke Detection for Large Area Coverage Applications

freedom residential flush pendent sprinkler vk476 (K4.9)

All by design. ASSA ABLOY Door Controls

Fire Suppression Systems

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

Range brochure. Beam detection. others look up to.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

NUAIRE POSITIVE INPUT VENTILATION SYSTEMS DRIMASTER-ECO LOFT MOUNTED POSITIVE INPUT VENTILATION SYSTEMS

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Hold-open magnets DORMA

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

This document is a preview generated by EVS

Smoke Vent Control Panel PCB4 V4 Installation Manual

Soldeu 4 Portsea View Bedhampton Hampshire

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

Design Guidelines Fire Safety in New and Refurbished Buildings

Operation & Maintenance Manual

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

Fire Protection. Intumescent fire and smoke seals for door assemblies

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

education seating solutions

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Uniclass L442 CI/SfB (34) X. Architectural Handrail and Balustrade. Architectural metalwork systems

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

KoolthermTM. Technical Data. HVAC & Building Services Pipe Insulation

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Welcome to ambus. About Sven Christiansen. Why Choose Sven Christiansen?

Loss Prevention Standards

IS-ORANGE Envirograf. Orange Book. Ventilation. T +44 (0) F +44 (0)

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

Intelligent Security & Fire Ltd

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

ACTIVE FIRE CURTAINS INTISI7

Denco has been producing and installing. equipment specifically designed for the precise. control of air temperature, humidity and quality

lindab ventilation Lindab Comfort Waterborne indoor climate solutions Product overview

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Transcription:

W W W. C O O P E R S F I R E. C O M FireMaster CONCERTINA THE INVISIBLE ACTIVE FIRE CURTAIN BARRIER ASSEMBLY Cl/Sfb (31.5) Fire Doors The Fire Curtain Barrier WITHOUT CORNER POSTS Inspiring design, maximising floor space and increasing income. Approved as a 4 Hour Active Fire Curtain Barrier Assembly.

DESIGN SOLUTIONS THAT WORK FOR YOU OPEN SPACE Virtual compartments with unlimited width for maximum design flexibility STAIRWELLS No need for non-loadbearing fire-rated walls ESCALATORS No need for non-loadbearing fire-rated walls LOBBIES ATRIA No need for non-loadbearing fire-rated walls and doors Allows multi-floor concourse openings for large atria Case study: Oil Search, Sydney Australia Ensuring you remain protected from fire without compromising the intended architectural open plan design can be problematic, especially when you re protecting stairwells and atria. Such a situation led Oil Search Australia to employ Coopers Fire to develop and manufacture a unique circular 18-sided Concertina that ensures the office complies with stringent Building Code requirements whilst permitting an imposing and more efficient office space overlooking Sydney Harbour. The revolutionary Concertina design arrangement protects the open plan spiral staircase whilst removing the need for side guides and columns to provide the full fire rating. The end product provided a uniform look across all 3 levels, mirroring the spiral staircase opening. We have also installed L shaped and four/sided configurations of the Concertina into Selfridges, Oxford St and Bovis Lend Lease, London. Benefits Only one product/system is required to achieve the required fire rating. No side guides, no columns and no posts. A curved ceiling interface panel fits in with the look and feel of the building. No compromise on the fire performance. Interfaces with the zone smoke control system. Modular construction that s quick to install. No secondary steelwork required. Multi-functional operation.

1 PRODUCT DESCRIPTION The Coopers FireMaster Concertina Fire Curtain Barrier provides the same protection as 4 hour Steel Fire Shutters but at a fraction of the size and weight, with no need for columns, corner posts, side guides and intrusive ceiling interfaces, giving architects, consultants, specifiers and owner/occupiers a whole new way to approach building design, maximising floor space and increasing rental income. The Concertina is a revolution in active fire separation. Split drop deployment offers safe escape and preliminary smoke control as well as Gravity Fail-Safe* deployment and auto-retract enabling easy integration with a dedicated fire alarm or building management system. 2 PRODUCT ADVANTAGES NO MORE COLUMNS AND CORNER POSTS With no visible support posts required, the Concertina offers open plan environments. NO MORE INTRUSIVE SIDE GUIDES No corner posts and columns mean that there is no longer the need for side guides to compromise design. NO MORE INTRUSIVE CEILING INTERFACES Our ceiling interfaces are designed to blend with your existing ceiling, resulting in a discrete and aesthetically pleasing finish. INCREASE FLOOR SPACE Free up space that s usually occupied by insulated, fire glass or non-loadbearing compartment walls. INCREASE INCOME Maximising floor space by opening up spaces will increase square meter yield and rental income. ANY SHAPE Every Concertina is bespoke and is manufactured to meet your specific requirements. ANY SIZE Unlimited widths; heights up to 8m* for 2 hour (120 minutes) integrity. 3 TAILOR MADE BESPOKE PRODUCT CONFIGURATIONS Developed to provide a bespoke alternative to fixed non-loadbearing fire walls, partitions and fire shutters, the Concertina can be used as part of a fire engineering solution in commercial and industrial applications such as airports, shopping centres, offices and hotels or where the need for maintaining open areas for access is vital. Faceted curve Multisided Square L shape corner * Curtains up to 5m in height have been approved as a 4 hour (240 minutes) integrity Active Fire Curtain Barrier Assembly. Trapezoid

4 STANDARD HEADBOX SIZES We have a design solution for any size requirement. For queries about special size requirements, please contact our technical department on 02392 454405 or email at cooperstech@coopersfire.com Model No Maximum barrier width Maxiumum barrier drop FM Concertina 45/22 Unlimited Up to 8M (Based on a 5m drop. Larger headboxes are available upon request.) 5 HOW ARE THE HEADBOXES INSTALLED? There are many fixing options to suit all types of ceiling configurations developed to integrate with both solid and suspended ceilings that enable total project flexibility. Soffit Suspended with unistrut Fix Canter levered I beam

6 HOW ARE THE BARRIERS CONCEALED? We can provide a range of ceiling interfaces developed to conceal the Curtain Barrier in the ceiling whilst still allowing access for service and maintenance. All our systems remain totally concealed when non-operational. SLAT TM Ceiling Interface Alternative Ceiling Interface Flush fit tray down Suspended ceiling 7 WHAT IF I NEED SIDE CHANNELS? With open shapes it s also possible to install the Concertina to work with traditional side retention systems whereby the barrier terminates against a fixed surface. The following diagrams illustrate both Recessed and Face Fix options. Recessed Fix Face Fix Traditional side retention system Recessed Face Fix

CONTROL OPTIONS Every Coopers Fire product is produced using Drives and Control systems specifically developed and manufactured by us at our factory in the UK. Every one of our Drives and Control Systems has been developed using the Coopers Fire patented Gravity Fail-Safe* system, leaving you safe in the knowledge that your Fire Protection system is 100% Coopers Fire. CONTROLS SPECIFICATION Power Supply: Battery: Alarm Signal: 230V AC 50Hz dedicated supply via 13Amp un-switched fused spur 2 x 12V 12A/h lead acid batteries Normally closed volt-free contacts. Open on activation Test Facility: Display: Power Supply Size: Motor Control Unit Size: Key switch and Reset button on PSU Power On, Alarm Active and Alarm Off 400mm(w) x 500mm(h) x 210mm(d) 300m(w) x 200mm(h) x 80mm(d) PRODUCT SPECIFICATION The complete system has 240 minutes (4 hrs) Fire Integrity to BS EN 1634-1:2008 and meets the relevant requirements of BSi PAS 121:2007 and BS 8524-1(Draft). The curtain has National Class 0 in accordance with A13 (b) Approved Document B 2006 Edition Fire Safety to England & Wales Building Regulations 2010, tested for fire propagation to BS 476-6:1989+A1:2009 and surface spread of flame to BS 476-7:1997. DON T BE LIABLE! Fire Curtain Barriers MUST have a Total Fail-Safe by Gravity* System in the event of total mains, wiring and/or system corruption. Coopers Fire, with their unique patented TFSG system, are the only Curtain Barriers with Independent Third Party Certification by a UKAS approved certification body, and are fully tested as compliant with BS EN 1634-1:2008, BSi PAS 121:2007 and BS 8524-1 (Draft). For information, to get a quote or to book a CPD workshop please call +44 23 9245 4405 or email us at info@coopersfire.com Coopers Fire Ltd has a policy of continuous product improvement. As such we reserve the right to change design and specifications without prior notice. Please check our website www.coopersfire.com for the latest information. 2012 Coopers Fire Ltd. All content and products are copyright of Coopers Fire Ltd. * Multiple patents granted and pending. The paper used in this brochure is from sustainable sources and promotes responsible management of the world s forests Series 1. V Feb 2013. Registered Office: Coopers Fire Ltd, Edward House, Penner Road, Havant, Hampshire, PO9 1QZ United Kingdom Registered in England Number: 2010274 Phone: +44(0) 23 9245 4405 Fax: +44(0) 23 9249 2732 Email: info@coopersfire.com Web: www.coopersfire.com Assessed to ISO 9001:2008 FM 22356 Assessed to ISO 14001:2004 LQR 4007272