HILTI SUBMITTAL PACKAGE OSHA TABLE 1, SECTIONS vi AND vii

Similar documents
DUST REMOVAL SYSTEM SUBMITTALS

DUST REMOVAL SYSTEM SUBMITTALS

DUST REMOVAL SYSTEM SUBMITTALS

Use saw equipped with integrated water delivery system that continuously feeds water to the blade.

Silica Exposure Control Plan

Crystalline Silica Control Methods

OSHA Table 1

RESPIRABLE CRYSTALLINE SILICA PARAGRAPHS (C) THROUGH (J)

Silica Dust Specified Exposure Control Methods

Engineering and Work Practice Control Methods

TABLE 1: SPECIFIED EXPOSURE CONTROL METHODS. Required Respiratory Protection and Minimum Assigned Protection Factor (APF)

Specified Exposure Control Methods When Working With Materials Containing Crystalline Silica

or with a higher exposure potential than the processes, types of material, control methods, work

Respirable Crystalline Silica Exposure Control Plan

Table 1. Exposure Control Methods for Selected Construction Operations

HILTI VACUUM PORTFOLIO

Silica Exposure Control Matrix

ENGINEERING CONTROLS FOR SILICA DUST (DUST COLLECTION SYSTEM)

Application Concrete Drilling & Anchoring

CONCRETE AND MASONRY SYSTEMS MADE IN GERMANY MOST ADVANCED INTEGRATED DUSTLESS SYSTEMS OSHA COMPLIANT

Dust. Solutions that increase working comfort, safety and productivity. Less dust. More productivity. Hilti. Outperform. Outlast.

CONTRACTOR GUIDE What You Need to Know About the New OSHA Silica Dust Standard

Application Concrete Drilling & Anchoring

DD 200. Printed: Doc-Nr: PUB / / 000 / 02

CONCRETE AND MASONRY SYSTEMS

VC VC English

MAKE DUST HISTORY REFERENCE GUIDE: PRO+GUARD DUST SOLUTIONS FOR CONCRETE DRILLING, DEMOLITION, GRINDING AND CUTTING

73. MEDICAL SURVEILLANCE - Triggers 74. 1)Exposure AL > 30 days/year 75. 2)Exposure > PEL 76. Wearing a Negative Pressure Respirator - 30 days/year

DD 30-W. English. Printed: Doc-Nr: PUB / / 000 / 04

TE 60-AVR TE 60-ATC/AVR

Powertools Ecoline. Ecoline Powertool set 5pcs. Ecoline Cordless screwdriver. Ecoline Mouse sander. High quality reliable tools.

TE 2 TE 2-M TE 2-S English

TE 60-AVR TE 60-ATC/AVR

MAKE DUST HISTORY REFERENCE GUIDE: PRO+GUARD DUST SOLUTIONS FOR CONCRETE DRILLING, DEMOLITION, GRINDING AND CUTTING

DD 500-CA Operating instructions Mode d emploi Manual de instrucciones Manual de instruções

TE 60-ATC/AVR English

TE 2 TE 2-M TE 2-S. English Français Español Português

Printed: Doc-Nr: PUB / / 000 / 00 VC X

Guidelines for Earthquake Bracing of Residential Water Heaters

VC 20 U VC 40 U VC 40-UE

Industrial Contractors Supplies

Milwaukee Introducing NEW Dust Extraction System for the Professionals.

MAKE DUST HISTORY MOVE TOWARD OSHA COMPLIANCE WITH PRO+GUARD DUST SOLUTIONS

Installation and use of Strong Central Vacuum Cleaning System

THE BUZZ Electrical Training Institute Newsletter November 2017

WARNING USER S MANUAL. Model iq 2000 Series Dust Collector with manual shaker

As mandatory dust collection

Portable Dust Collection Systems

SERIES CATALOGUE C & G. Shavings Collection System

ANGULAR TILE DRILL BEAST FB750W OPERATING MANUAL

Freestanding Treatment Console Installation

TE DRS-M. Bedienungsanleitung Operating instructions Mode d emploi Manual de instrucciones Istruzioni d uso Gebruiksaanwijzing Bruksanvisning

Operating instructions Mode d emploi zh ja ko cn ar

SAVE THESE INSTRUCTIONS

Attach the drain tube through the hole.

RVAC-100 VACUUM CLEANER MANUAL. For Household Use Only

TE 1000-AVR. English. Printed: Doc-Nr: PUB / / 000 / 04

Lead Safety for Renovation, Repair, and Painting. Requirements in the EPA RRP Rule:

VACUUM TUBE LIFTERS. The end result? operators never have to over-exert themselves when lifting loads.

MK-MANTA III OWNER S MANUAL PARTS LIST & OPERATING INSTRUCTIONS


Operating instructions Mode d emploi Manual de instrucciones Manual de instruções

DD 110-D. Operating instructions Mode d emploi Manual de instrucciones Manual de instruções. Printed: Doc-Nr: PUB / / 000 / 02

STEP BY STEP INSTALLATION INSTRUCTIONS. Natural Woven Shades. Standard Top Down/Bottom Up Slim Headrail Operable Lining

Clearance of PCB-laden sealants in buildings Operating guidelines recommended by the trade associations

TE 40 TE 40-AVR English

The Bose 151 SE Environmental Speakers. Owner s Guide

Installation Plan Washing Machine PW 811 PW 814 PW 818

ENCLOSED UNIT TECHNICAL MANUAL Items # &

Hilti HIT-HY 200 System. One giant leap. Hilti. Outperform. Outlast.

TE 70-AVR TE 70-ATC/AVR TE 80-ATC/AVR

TE 3-M TE 3-C. English Français Español. Printed: Doc-Nr: PUB / / 000 / 01

Installation plan Commercial Washing Machine PW 413 PW 418

Curb Inlet Filter INSTALLATION MANUAL. Bio Clean Environmental Services, Inc. 398 Via El Centro Oceanside, CA 92058

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

TILE SAW RODIA 207RS OPERATING MANUAL

BEAST RAIL SAWS RS34 RS48 RS59 OPERATING MANUAL

Set & $ave. Model Programmable Thermostat. installation and operation manual

PATTERSON FAN MANUAL. Operating, Installation & Parts Manual (OIPM) Patterson Fan Company, Inc Blythewood, SC

Cyclone Dust Collection & Separation INSTALLATION & OPERATION MANUAL

Instructions for the BASIC Air Handling System, Sizes General 1.1 Description of the System

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

Package Content. Decor Star 1 2. PL-011-GS Rev. A

DD 250 DD 200/HD 30 DD 200/ST 200

Safety Message to Installers of Federal Signal Siren Speakers

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

PRODUCT FULL NAME. dust control featuring tool & vacuum system

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

OSHA Subpart F Fire Protection and Prevention

E-CDR48-PL-0413 REVISED STARTING SERIAL # PARTS LIST MANUAL 48 CORE DRILL RIGS. EdcoParts.com

TE DRS-S. Printed: Doc-Nr: PUB / / 000 / 00

Handshower, Hose & Handshower Accessories

Patterson Fan Manual. Operating, Installation & Parts Manual (OIPM) Patterson Fan Company, Inc Blythewood, SC

Installation. Please keep this manual for future reference.

2000 Lincoln Town Car V8-4.6L VIN W Copyright 2013, ALLDATA Page Remove the screws and the RH cowl vent screen.

SYLLABUS. DIVISION: Business & Engineering Technologies REVISED: Spring CURRICULA IN WHICH COURSE IS TAUGHT: Automotive Analysis and Repair

INSTALLATION GLYDEA MOTORIZED TRACK PRODUCT OVERVIEW. 1. Glydea Motor 2. Motorized Drapery Track. 3. Wall Brackets 4. One Touch Ceiling Bracket

Active Thermal Management. SEC-1 Installation Instructions

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

TSS 15/55 Hi-Lift Vacuum

Transcription:

HILTI SUBMITTAL PACKAGE OSHA 1926.1153 TABLE 1, SECTIONS vi AND vii Section vi: r ig-mounted core saws or drills Section vii: h andheld and stand-mounted drills (including impact and rotary hammer drills) Current Hilti handheld and rig-mounted core drills DD 30-W DD 150-U DD 250 DD 350 DD 500 DBS 05/18 or instructions on how to assemble F these systems, please refer to the Hilti North America Youtube page

TABLE 1 REQUIREMENTS These systems fall under either Table 1, section vi: Rig-mounted core saws or drills or section vii: handheld and standmounted drills (including impact and rotary hammer drills). In order to be Table 1 compliant, the below requirements must be met: Section vi Use tool equipped with integrated water delivery system that supplies water to cutting surface Operate and maintain tool in accordance with manufacturer s instructions to minimize dust emissions OR Section vii Use drill equipped with commercially available shroud or cowling with dust collection system Operate and maintain tool in accordance with manufacturer s instructions to minimize dust emissions Dust collector must provide the air flow recommended by the tool manufacturer, or greater Have a filter with 99% or greater efficiency and a filter-cleaning mechanism Table 1 states that no respirator is required if the above controls are fully and properly implemented. Equipment / Task Engineering and work practice control methods Required respiratory protections and minimum Assigned Protection Factor (APF) 4 hours / shift > 4 hours / shift (vi) Rig-mounted core saws or drills Use tool equipped with integrated water delivery system that supplies water to cutting surface. None None Operate and maintain tool in accordance with manufacturer s instructions to minimize dust emissions. (vii) Handheld and stand-mounted drills (including impact and rotary hammer drills) Use drill equipped with commercially available shroud or cowling with dust collection system. Operate and maintain tool in accordance with manufacturer s instructions to minimize dust emissions. Dust collector must provide the air flow recommended by the tool manufacturer, or greater, and have a filter with 99% or greater efficiency and a filter-cleaning mechanism. Use a HEPA-filtered vacuum when cleaning holes. When used outdoors None None When used indoors or in an enclosed area None None 2

Core Drill Submittal Check below to see how your system can be compliant with 1926.1153 Table 1. To verify the generation of your tool, check the rating plate, or call Hilti at 800-879-8000 with your serial number. Tool name Accessory (any one) Method of compliance DD 30-W (rig mounted) DD 150-U (rig mounted) DD 250 DD 350 DD 500 DWP 10 (365595) Gardena connector with supplied water (4297) WMS 100 (3575546) DD 150-U Any SPX-Masonry corebit* Vacuums (can use any) VC 125-6 VC 125-9 VC 20-U VC 40-U VC 40-UE VC 150-6 X VC 150-10 X VC 150-6 XE VC 150-10 XE VC 300-17 X all Table 1 DD 30-W (handheld) DD 150-U DWP 10 (365595) Gardena connector with supplied water (4297) WMS 100 (3575546) Exposure assessment *Hilti s interpretation is that dust control core bits with a vacuum are categorized under Table 1 section vii: handheld and stand-mounted drills (including impact and rotary hammer drills). 3

SYSTEM OVERVIEW Core drills from Hilti use either a water delivery system or a shrouded core bit hooked up to a Hilti vacuum. Hilti currently offers the below systems with this configuration: Tool Accessory DD 30-W (rig mounted) DD 150-U (rig mounted) WMS 100 DD 250 DWP 10 handheld water pump DD 350 Any gardena connector with a supplied water attached to Hilti tool DD 500 Note: previous generations of tools may have different item numbers or nomenclature. Check with your local Hilti representative or product instruction manual to verify. Table 1 does not address handheld core drills being used wet. For this reason, the only way to comply with handheld wet core drilling is to utilize objective data or exposure assessment procedures. 4

Core Drill Submittal Tool Accessory Vacuum (use any) VC 125-6 VC 125-9 VC 20-U VC 150-6 X DD 150-U (handheld) Any SPX-Masonry corebit** VC 150-6 XE VC 40-U DD 150-U (rig mounted) VC 150-10 X VC 40-UE VC 150-10 XE VC 300-17 X DD 30-W* (handheld) * DWP 10 handheld water pump WMS 100 DD 150-U (handheld)* Any gardena connector with a supplied water attached to Hilti tool * Table 1 does not address handheld core drills being used wet. For this reason, the only way to comply with handheld wet core drilling is to utilize objective data or exposure assessment procedures. ** Hilti interprets dust control coring systems as being in Table 1, section vii handheld and stand mounted drills (including impact and rotary hammers) 5

CORING WET Diamond Dust Control OSHA Hilti developed diamond coring systems are equipped with a water connection which is to be attached to a pressurized water source. When rig mounted, these systems are compliant with OSHA 1926.1153, Table 1. Set-up 1. If required, attach the drill stand to the drilling surface using the appropriate anchoring accessories. 2. Attach the water source to the tool. 3. Insert the bit and ensure its tightened by turning the chuck to the closed position. 4. Turn on the water. 5. Verify you have the appropriate amount of water for the application. Verify the water delivery system operates properly with no leaks, delivering water freely inside the bit. See instructions for core machines. Drilling 1. Start the water before beginning to drill. 2. Begin drilling, applying the required amount of pressure. 3. Adjust water flow rate to minimize visible dust. Cleaning and maintenance See instructions for core rigs. Clean up of slurry before it dries can help minimize secondary exposure. Ensure that cleanup and disposal of concrete slurry is done in accordance with relevant state/local regulations. 6

Core Drill Submittal CORING DRY CORING DIA Dust Control OSHA Hilti developed dry diamond core drills and bits to be attached to a Hilti vacuum with a filter cleaning mechanism and 99% filter efficiency. Hilti considers these coring applications to fit in, and be in compliance with, OSHA 1926.1153, Table 1, (vii) handheld and stand mounted drills (including impact and rotary hammer drills). Set-up 1. If using as rig mounted, attach the drill stand to the drilling surface using the appropriate anchoring accessories. 2. Attach the vacuum hose to the drill s vacuum hose connector. 3. Insert the bit and ensure its tightened by turning the chuck to the closed position. 4. Start vacuum. 5. Verify proper operation of the dust collection system, including suction at the end of the bit. Check for damage or leaks in the vacuum, hose, and hose connector. See instructions for vacuum. Drilling 1. Start the vacuum before beginning to drill. 2. Begin drilling, applying the required amount of pressure. 3. To maximize dust collection, after the hole is drilled, slowly withdraw bit from the hole, and keep the drill and vacuum running until the bit is fully withdrawn. Cleaning and maintenance See instructions for vacuum. 7