ROPER Consulting. Subject: Bonsall High School Project. Dear Mr. Medcalf and Members of the Board of Trustees,

Similar documents
STAFF REPORT SAUSALITO CITY COUNCIL

Fire Adapted Communities Background

Travis County Emergency Services District #1 Standard Operating Guidelines

San Mateo County Fire. In Cooperation with

Fire FY Performance Plan

Department of Community Development. Planning and Environmental Review Division Revised Notice of Preparation

SOUTH SANTA CLARA COUNTY FIRE PROTECTION DISTRICT INTRODUCTION

City of Los Angeles January FIRE PROTECTION

INTERNAL DRAFT - NOT FOR DISTRIBUTION

Wildfire in Travis County

Nevada County. Fire Prevention. Programs. BOS Workshop January 25, 2018

Community Wildfire Safety Program. June 26, 2018

OXNARD FIRE DEPARTMENT Fire Watch Guidelines

MCPS School Safety & Security Presentation

SECTION 5.9 Fire Protection

Town/Village of Waterford Multi-Hazard Evacuation Plan

ATTACHMENT A. California Health and Safety Code Section Findings

READY, SET, GO! A Wildfire Readiness Guide for Property Owners

Police Services & Campus Safety/Emergency Preparedness. Anne P. Glavin, Chief of Police Department of Police Services

Preliminary Summary Report of Serious or Near Serious CAL FIRE Injuries, Illnesses and Accidents GREEN SHEET. Firefighter Burn Injury.

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

MCPS School Safety and Security Presentation

JAMES F. McMULLEN CURRICULUM VITAE

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

MCPS School Safety and Security Presentation at Damascus High School

South Elgin & Countryside Fire Protection District

Pebble Beach Community Services District Fire Department 3101 Forest Lake Road, Pebble Beach, CA

IV. ENVIRONMENTAL IMPACT ANALYSIS J. PUBLIC SERVICES 1. FIRE PROTECTION

COMMUNITY WILDFIRE PROTECTION PLAN POWELL RIVER REGIONAL DISTRICT

Emergency Notification Plan. Developed By: Cleveland State University Police Department Office of Emergency Management

Parks, Open Space and Trails

3.0 CARSON CITY FIRE HISTORY & FIRE RESOURCES

UCLA Policy 130: Emergency Notifications (BruinAlert) DRAFT FOR PUBLIC REVIEW

AGENDA ITEM # 9.1

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

TAHOE DOUGLAS FIRE PROTECTION DISTRICT JOB DESCRIPTION Fire Inspector Fire Prevention

Community Development Planning Division

PURPOSE AND NEED FOR ACTION PUBLIC SCOPING LETTER SILVER GLEN SPRINGS RECREATION ENHANCEMENT PROJECT. Ocala National Forest

Enter Department Name Emergency Action Plan

Low Rise Residential occupancies are required to perform one fire safety training and one evacuation drill annually

Branch Fire Rescue Services

Describing the Integrated Land Management Approach

STANDARD OPERATING PROCEDURES RESPONDING TO EMERGENCIES DEPARTMENT RESPONSE PROCEDURES EFFECTIVE: AUGUST 2007

Midlothian Fire Department 2015 Annual Report

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Evacuation and Lockdown Plan

Public Hearing. Preliminary Draft Development Plans (zoning plans) Dutch Quarter and Middle Region. June 28, 2016

TETON COUNTY FIRE PROTECTION RESOLUTION FOR NEW SUBDIVISIONS 2008 Edition. Chapter I General Provisions

SCALES NW EMERGENCY ACTION PLAN

STONY HILL RURAL FIRE DEPARTMENT OPERATING GUIDELINES

BERKELEY FIRE DEPARTMENT (141 FTE)

Fire Drill Policy. Facilities Manager DCD. Statutory. Principal. Staff. REVIEW DATE 20 th August Owner. Version Number: 8 Legal Sign:

Concept Master Plan. for. Draft of. Wildlife Management Area. Prepared for. June, 2008

4.1.3 LAND USE CATEGORIES

Lassen Community College Course Outline

San Rafael Fire Dept. Vegetation Management

Paul Amundson Evergreen Fire Rescue Wildland Fire Coordinator work

Nature as a Classroom As an agriculture student majoring in Forest Science, concentrating originally on crop and soil sciences, I devoted my time

The Vision. Photo provided by The Minervini Group. 46 Vision, Objectives & Strategies

3.10 LAND USE SETTING PROJECT SITE EXISTING LAND USE DESIGNATIONS AND ZONING. General Plan Land Use Designations.

APPENDIX D Evacuation Planning Guidelines

Preventing Catastrophe: the Firewise Approach to Community Design. Denise Laitinen Firewise Communities Hawaii September 24, 2009

COLLABORATION & TECHNOLOGY TO IMPROVE ACTIVE SHOOTER RESPONSE

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

2011 ASLA Design Awards

Department of Plant Biology Emergency Action Plan

High-Rise Active Shooter Building Owners and Managers Association Emergency Preparedness Committee Workshop

REQUIREMENTS. For FIRE DEPARTMENTS. State of West Virginia. Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY

FIRE SAFETY AND PREVENTION POLICY

EMERGENCY PREPAREDNESS: EVACUATIONS

Physics Department. Emergency Action Plan & Evacuation Guide. In compliance with: California Code of Regulations. Title 8, Section 3220

Proposed Safety Element Amendments

The Planner will identify the information required for the review to obtain a Development Permit from the following list:

Annex 2 - Shelter-in-Place

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: March 15, 2012

CIRRICULUM VITAE MICHAEL A. GINN

WHAT IS FIRE DISASTER? Fire Disaster is an occurrence or an incident of such magnitude which creates a situation in which the normal life is suddenly

BCGEU JOB DESCRIPTION MINISTRY OF FORESTS

SANTA CLARA COUNTY FIRE DEPARTMENT CENTRAL FIRE PROTECTION DISTRICT INTRODUCTION

Humboldt No. 1 Fire Protection District

EMERGENCY LOCK DOWN PROCEDURE

PEMBROKE PINES FIRE DEPARTMENT ISO Class 1 Department

Series 3000: Students Procedure Emergencies 3432P

The Contra Costa EMS System and Fire Station Closures: Impact and Mitigation

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

THE UNIVERSITY OF TEXAS AT SAN ANTONIO. Special Event Planning Considerations

2007 TAC SUSTAINABLE URBAN TRANSPORTATION AWARD SUBMISSION. Bridge Over Highway 401 for Pedestrians and Cyclists in Waterloo Region

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT

Facility Emergency Action Plans

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

The Cannabis Industry: Fire Department Requirements

Thomasville fire rescue

ORDINANCE NO

Emergency Procedures Overview

Fire Safety Plan Information. For Construction and Demolition Sites

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

LexisNexis (TM) New Jersey Annotated Statutes

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Transcription:

ROPER Consulting 806 Canada St. Ojai, CA 93023 Phone: (805) 377-0493 E-Mail: boz806@gmail.com To: Bonsall Unified School District Date: March 20, 2018 Facilities, Maintenance and Transportation Attn: David Medcalf 31505 Old River Road Bonsall, CA 92003 Subject: Bonsall High School Project Dear Mr. Medcalf and Members of the Board of Trustees, I have been asked by Save Gird Valley citizen s group to review and evaluate the planning conditions for the Bonsall High School project. I have reviewed aerial photography of the site and surrounding areas on Google Maps and reviewed the proposed site plan. I have been in the fire service for 40 years serving as the Ventura County Fire Chief, from 1998 to 2012, and as the Nevada State Forester, from 2015 to 2016. I was part of the team that developed California s response to major emergencies, which included policy development at the local, State and Federal level. I also helped create the National Wildland Fire Cohesive Strategy. While serving in all-hazard emergency response role, I focused on the wildland fire topic. Development will naturally occur in fire prone wildland areas in the future. The goal should be to design a project that is fire safe, even if first responders cannot immediately respond to an emergency, a contingency that is increasingly likely when large, and wind driven, multi-fire events occur in Southern California. A Fire Safe project can be accomplished through proper planning, building codes, public education and involved residents. Some of my recommendations may have already been accepted in the Planning process, but I want to put forward a comprehensive list of considerations as they are often fundamentally interrelated. This project is located in an area that has a repetitive fire occurrence history as evidenced by the Cal Fire Very High Fire Hazard Severity Zone maps (2012). It is not a matter of if a fire will start, it s a matter of when. Fire history indicates a five-ten year repetitive cycle that is primarily fueled by flashy vegetation and very strong Santa Ana winds. The combination of fuels, winds and population density create public safety concerns for first

2 responders, public officials and residents. When a wildland fire occurs, the rate of spread can be extreme (Cedar Fire, 2003), thus causing public anxiety and safety concerns. The proposed project site is located approximately 0.3 miles north of Hwy. 76 on Gird Road. It is currently a rolling hill site with native grasses, brush and assorted trees. It is bordered by the Golf Club of California on the west, urban housing tracts on the north and undisturbed native vegetation on the south/east. It must be noted that until the south/east border areas are developed, this project side is especially impacted by destructive Santa Ana wind conditions Below are bullet points that must be addressed for this project in addition to the general public safety topics: Access (ingress & egress public & FD/Law access) The project s use and daily population numbers must be aligned with a traffic engineer s study for evacuation purposes. This requires a study that reviews daily static traffic flows and then overlaid with accelerated evacuation traffic flows. This traffic study must account for residents leaving during duress and first responders gaining entry. Consideration should also be given to egress roads that dump onto existing public streets and whether these access points cause a choke point. Standard planning conditions dictate two public access points designed specifically for evacuation flows for a project of this type/size. Multiple ingress and egress points are also becoming more important beyond the requirements for fire evacuation as school districts and law enforcement are addressing active shooter practices. Some fire agencies allow Fire Department (FD) restricted access points, but these restricted access points may have design flaws. The primary concern is that they require a fire department representative to hand manipulate the access controls (gate). The drawback is that these access points are a second thought and require special knowledge to operate, thus limiting law enforcement, medical personnel and the public access. There are work arounds to access these controls, but they must be addressed during design. The proposed project currently has only one access point off Gird Road, which causes a choke point. Consideration should be given to a secondary Gird Road connection or at least a road design to eliminate a single choke point. (CFC 503.1.2 Additional Access The fire code official is authorized to require more than one fire apparatus access road if a single access could limit access based upon

3 several factors. ) Emergency Response Part of North County Fire s operational design is to establish a "standards of cover," which provides a timely response for medical and structure fire responses. A wildland fire under high wind situations causes extreme rates of fire spread, thereby dictating that new development projects be designed to withstand a fire in the advent no first responders resources are available. The speed with which wildfires can reach the site needs to be carefully evaluated in this context as fire spread arrival times in a wildland area can easily be shorter than evacuation time requirements. The proposed project will be served primarily by the two nearest fire stations, North County Fire Protection District #4 & 5. Both fire station response times will be impacted by Hwy. 76 traffic flows during peak traffic periods. Fire Station #2 will be the third-in resource via remote residential access to Gird Road. North County Fire is a full service fire department with excellent performance and relationships with partner agencies. ( BEHAVE fire modeling program can display various fire spread/speed models in relation to time periods that affect evacuation needs) Emergency Notification Due to the rapid spread of wildland fires, some type of localized emergency notification system should be designed to quickly prompt students, faculty and parents about an emerging fire. Wildland fire case studies show most fatalities occur as people are trying to escape fast moving fires. (http://www.readysandiego.org/alertsandiego/) Water Supply A water supply system must be designed to meet hillside elevation demands for volume and pressure. If a local elevated gravity fed supply system is not possible, then backup electrical power must be incorporated into the pump-pressurized system. (Backup pressure systems - https://www.epa.gov/sites/production/files/201503/documents/planning_for_an_emergenc y_drinking_water_supply.pdf & https://www.awwa.org/portals/0/files/publications/documents/m31lookinside.pdf)

4 Evacuation Plans Given the fire history of this geographical area, a detailed evacuation plan template should be developed before the actual emergency as well as a re-entry plan. North County Fire has such a plan on their website and it needs to be incorporated into the school s emergency readiness plans. These plans are great tools in educating the occupants about preparation and of course helpful to local fire authorities. As a general rule, the higher the density of a proposed project, the higher the evacuation risks. (www.northcountyfireprotectiondistrict.org/pdf/bureau/evacuation_map_fallbrook.pdf) Temporary Safe Refuge Areas North County Fire has developed a Temporary Shelter plan/map and displays it on their website. These shelters are temporary in nature and this project should be considered part of this plan once construction is completed. These areas can be large park settings with non-combustible landscaping and/or be large public assembly structures that are fire safe. The school district should also train their bus drivers about evacuation plans and the location of these temporary shelters. (www.northcountyfireprotectiondistrict.org/pdf/bureau/evacuation_map_fallbrook.pdf) (Reference to subject in principle www.fireadapted.org) Public Education Every student, faculty and parent must be made aware of the serious wildland fire threat and fire history. They need to receive and understand the tenets of the Ready, Set, GO! (RSG) program. This program teaches occupants about wildland fire basics, how to harden your home, situational awareness, what to do when a fire starts, evacuation and what to do if you cannot escape. Students, faculty and parents must learn and accept their personal responsibility for living in a dangerous wildland environment. RSG needs to be taught as an integral part of the school s emergency readiness plan. North County Fire has adopted RSG and should be a key partner with this new school. (http://www.readyforwildfire.org/ready-for-wildfire-app/) (http://wildlandfirersg.org/resident)

5 Building Codes The use of modern building/fire codes and local ordinances are a requirement of any new development designed to harden structures and reduce life loss. North County Fire has adopted the latest edition of the State Building/Fire Code. The Office of the State Architect should also govern design of the school, so Building/Fire code compliance should be granted. Buffer Zones This project will be putting occupants into the wildland fuel zone; therefore a defensible space zone must be created and maintained by the school district. These zones may be irrigated landscapes, natural landscape that uses native fire resistance vegetation and/or use of selected clearing. The size and scope of the Buffer Zone/s will depend upon the slope of the land surrounding school structures and neighboring fuel type. The minimum zone should be 100 feet wide between structures and native fuels and may be greater if slope dictates. The buffer zone is an absolute condition and must be maintained even during drought conditions. (http://www.readyforwildfire.org/defensible-space/) (Note: The annotations to each bullet point may be contained within NCFPD s adopted codes, ordinances or be recognized as an industry best practice. Wildland fire planning aspects are not wholly contained in one specific code or ordinance, but must be interpreted to each project in the design phase.) Population growth and associated functions (i.e. schools) within these wildland fire prone areas must be addressed as a holistic, systematic approach. Each component listed above must be addressed in its entirety; failure to do so may compromise public safety success. The primary responsibility public officials have is life safety, therefore egress issues as they pertain to evacuations are the #1 priority. If egress decisions are altered, then secondary factors are even more important in the planning phase. The challenge before us is how to allow safe and responsible growth in fire prone areas, especially schools. Growth in these wildland fire prone areas can normally be done safely, but it takes a good planning and public/private partnerships for success. Sincerely, Bob Roper Roper Consulting