TEAM 6 NWARAMBILLI UGBODE

Similar documents
Park Gate. Dubai, United Arab Emirates

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

PENNSYLVANIA. Downloaded

(DC1) Direct Development Control Provision DC1 Area 4

Residential Care Facilities Requirements

SMEAL COLLEGE OF BUSINESS BUILDING University Park, PA

CITY OF VIRGINIA BEACH PLANNING COMMISSION DESIGN AWARDS PROGRAM 2012

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

For more information go to

DAYLIGHT AS A VISUAL EXPERIENCE

Residential Based Care Facility Guidelines

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL fpeschulte.

Design Guidelines - 1 -

BAINBRIDGE ISLAND MUSEUM OF ART

CHAPTER 7 ALTERATIONS LEVEL

Schematic Design Proposal Presentation

Jamie Devenger Senior Thesis Princeton University Sherrerd Hall 1 Lighting Proposal Memo September 11, 2009

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

Landscape and Streetscape Design 2.5

PD-32: Light Pollution

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

Adelaide Homes Design Guide 4 - Winter warming

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Schematic Design Presentation December 15, 2006 David Smith

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

Life Safety - Means of Egress/Exits NFPA 101

FRUITVALE TRANSIT VILLAGE (Phase 2) Residential Project

Proposed for Vic West Neighbourhood Plan. Design Guidelines for Intensive Residential Development - Townhouse and Attached Dwelling

The Village. Chapter 3. Mixed Use Development Plan SPECIFIC PLAN

Planning Board Hearing October 20th, 2016

Agency for Health Care Administration

Chapter 11. Industrial Design Guidelines 11.1 INTRODUCTION AND PURPOSE 11.3 SITE PLANNING GUIDELINES 11.2 GENERAL DESIGN OBJECTIVES

Open to Below: A Discussion of Allowed Floor Openings. Jay A. Ierardi, Ph.D., P.E., LEED AP. Kevin S. Hastings, P.E., LEED AP

1.3 TOWNHOUSES AND ROWHOUSES

DEVELOPMENT CONTROLS MEDICAL DISTRICT

North Elevation Existing trees along Pike Street were preserved and enhanced with extensive planting.

GUIDING LIGHT ASSEMBLY CHURCH MIXED-USE ARCHITECTURE

Revitalization Guidelines for Corridors, Villages and Town Centres

Precedent Studies. Hammarby Sjostad, Stockholm: The City of Stockholm s environmental goals for Hammarby Sjöstad:

Module 7. Control of Smoke & Highlights of Code Requirements

LIFE SAFETY CODE ESSENTIALS PRESENTED BY: LARRY VIGIL, RISK CONSULTANT

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Sustainable Strategies for School Development in Urbanizing Areas

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

A N A L Y S I S 1 : View of Geisinger Gray s Woods Ambulatory Care Campus from Gray s Woods Boulevard. Personal Photo.

TECHNICAL ASSIGNMENT #3: SCHEMATIC LIGHTING DESIGN

KAPSARC Competition Entry. Riyadh, Saudi Arabia

Chapter Nursing Homes

MULTI-LEVEL & COVERED BOOTH CONDITIONS

SITE SYSTEMS: FANNIE MAE EXPECTED USEFUL LIFE TABLES (FMEUL)

Sustainable Tower CHOICE 1

Sierra Springs Regional Commercial Master Site Plan Airdrie, Alberta Hopewell Development Corporation Project No May 26, 2010

HARRY RANSOM HUMANITIES RESEARCH CENTER

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

Garden edges provide vertical plantings to buffer the neighbors from the building facilities around the entire campus.

Lighting Existing Conditions and Design Criteria Report

Assignment 1: Narrative

Agency for Health Care Administration

Gas Works Site Land-Use Study

Main Lobby Area (North Vestibule thru South Vestibule):

CITY OF CLEVELAND GREEN DESIGN GUIDELINES

University Park, PA. The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr.

Franklin Square Hospital Center

The Bilco Company has partnered with industry pioneer Colt to bring dual purpose natural and smoke ventilation products to North America.

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Memo. B R A Y H e r i t a g e

6 STANDARDS THAT APPLY TO ALL

University of Illinois Business Instructional Facility LEED Gold Design. University of Illinois Business Instructional Facility

PLAN REVIEW SUBMITTAL GUIDE

Design Guidelines. Roosevelt. Mike Podowski DPD Design Guidelines Ordinance ATT 13 August 13, 2012 Version #1

Lighting Summary - Interior

PRESENTERS OVERVIEW COMMUNITY WORKSHOP OVERVIEW OF THE 2010 EDITION OF THE CALIFORNIA BUILDING STANDARDS CODE AND LOCAL AMENDMENTS

The following translation is for informative purposes only. The legally binding text is found in the Boverket s Code of Statutes (

Appendix. The following pages provide definitions of some of the more specialized terms used in the Design Guidelines.

CHAPTER 8. Mrs. Zimman s Class - Central Elementary

E25 (D) Automatic controls for general means of egress lighting

Thesis Proposal Update #2

Duke University Medical School. Duke School of Nursing

The SLL Lighting Handbook

Short-Term & Accessory Short-Term Rental Safety Certification

BUFFERS, TREE PROTECTION AND LANDSCAPING. Sec Purpose and Intent.

August 15, 2013 Page 1 of 19

Carpenter Center Cambridge, MA DAYLIGHT AS A DESIGN FACTOR Anahita Anandam

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

4 C OMMUNITY D ISTRICTS

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

MISSION To prevent the loss of life and property and to reduce injury by providing emergency response, education and prevention services.

lot flankage Y street 16m 6m landscape strip for large site 3m landscape strip for small medium site

(c) DH-3 - Dixie Highway High Intensity Mixed-Use District (i) DH-3 - Dixie Highway High Intensity Mixed-Use District Use Table.

Diamond Schmitt Architects MEDIA RELEASE November 24, 2011

Executive Summary. Houston Museum of American Art New York, New York

Windo-w Planning Principles

CONTROL SYSTEM. How to design daylight into your building using electronically tintable glazing.

City of Green Administration Building. Brian Koze November 12, Lighting Schematic Design Presentation

Lindsey Beane. Executive Summary

Jennifer Mers. Rio Hondo Library and Learning Resource Center. Executive Summary. General Building. Lighting/Electrical Option

4 Semi-Private & Private Open Spaces

Transcription:

ATRIUMS OVERVIEW PRECEDENTS SCHEMATIC DESIGN GREEN ROOFS ATRIUMS TEAM 6 NWARAMBILLI UGBODE EKATERINA SIGAL SERGIO ZAPATA

ATRIUMS OVERVIEW PRECEDENTS SCHEMATIC DESIGN GREEN ROOFS Atrium of the basilica of Sant'Ambrogio, Milan, 1088 1128. Alinari/Art Resource, New York IN AN ANCIENT ROMAN HOUSE, AN OPEN CENTRAL COURT THAT CONTAINED THE IMPLUVIUM, A BASIN WHERE RAINWATER COLLECTED. IT ORIGINALLY CONTAINED THE HEARTH AND FUNCTIONED AS THE CENTER OF FAMILY LIFE. THE TERM LATER CAME TO BE USED FOR THE OPEN FRONT COURTYARD OF A CHRISTIAN BASILICA,, WHERE CONGREGANTS COLLECTED BEFORE SERVICES. THE ATRIUM WAS REVIVED IN THE 20TH CENTURY IN THE FORM OF GLASS-COVERED, GREENERY-FILLED MULTISTORY SPACES SOMETIMES FOUND IN SHOPPING CENTERS, OFFICE BUILDINGS, AND LARGE HOTELS. - http://www.merriam-webster.com/dictionary/atrium IN ARCHITECTURE, AN ATRIUM (PLURAL: ATRIA OR ATRIUMS) IS A LARGE OPEN SPACE LOCATED WITHIN A BUILDING. ATRIA WERE A COMMON FEATURED IN ANCIENT ROMAN DWELLINGS, PROVIDING LIGHT AND VENTILATION TO THE INTERIOR. MODERN ATRIA, AS DEVELOPED IN THE LATE 19TH AND 20TH CENTURIES, ARE OFTEN SEVERAL STORIES HIGH AND HAVING A GLAZED ROOF AND/OR LARGE WINDOWS, AND OFTEN LOCATED IMMEDIATELY BEYOND THE MAIN ENTRANCE DOORS. ATRIA ARE A POPULAR DESIGN FEATURE BECAUSE THEY GIVE THEIR BUILDINGS A "FEELING OF SPACE AND LIGHT". FIRE IS AN IMPORTANT ASPECT OF CONTEMPORARY ATRIUM DESIGN DUE TO CRITICISM THAT POORLY DESIGNED ATRIA COULD ALLOW FIRE TO SPREAD TO A BUILDING'S UPPER STORIES MORE QUICKLY. THE 19TH CENTURY BROUGHT THE INDUSTRIAL REVOLUTION WITH GREAT ADVANCES IN IRON AND GLASS MANUFACTURING TECHNIQUES. COURTYARDS COULD THEN HAVE HORIZONTAL GLAZING OVERHEAD, ELIMINATING SOME OF THE WEATHER ELEMENTS FROM THE SPACE AND GIVING BIRTH TO THE MODERN ATRIUM. - http://en.wikipedia.org/wiki/atrium_%28architecture%29

ATRIUMS OVERVIEW THE FOUR FLOOR ATRIUM OF GOULD HALL 3949 15th Avenue NE Seattle, WA USA COLLEGE OF ARCHITECTURE AND URBAN PLANNING, AT THE UNIVERSITY OF WASHINGTON PRECEDENTS SCHEMATIC DESIGN GREEN ROOFS FIRST FLOOR PLAN - https://digital.lib.washington.edu/architect/structures/6068/

ATRIUM OF MEYERS PEDIATRIC HOSPITAL Florence, Italy ATRIUMS OVERVIEW PRECEDENTS SCHEMATIC DESIGN GREEN ROOFS THE MEYERS PEDIATRIC HOSPIAL IN FLORENCE, ITALY IS AN EXCEPTIONAL DESIGN THAT HARNESSES ARCHITECTURE TO HELP THE HEALING PROCESS. THE COMPLEX IS LOCATED IN A PARK-LIKE SETTING AND CONSISTS OF AN EARLY 20TH CENTURY BUILDING UPDATED WITH A NEW WING. WITH AN EXTENSIVE GREEN ROOF, ROBUST DAYLIGHTING, AND COPIOUS ART AND OPEN SPACE THE HOSPITAL PROVIDES AN IDEAL ENVIRONMENT FOR HEALING. - http://inhabitat.com/stunning-green-roofed-hospital-heals-through-green-design/ atrium-at-night/

ATRIUM OF KURAYOSHI PARK SQUARE Kurayoshi, Japan ATRIUMS * ALSO FOUR FLOORS OVERVIEW PRECEDENTS SCHEMATIC DESIGN GREEN ROOFS http://www.cecobois.com/repertoire/index.php?option=com_rea&view=fiches&id=217&itemid=1

ATRIUMS OVERVIEW PRECEDENTS SCHEMATIC DESIGN GREEN ROOFS

ATRIUMS OVERVIEW PRECEDENTS SCHEMATIC DESIGN GREEN ROOFS BUILDING A GREEN ROOFTOP INVOLVES INSTALLING A WATERPROOF BARRIER OVER THE ROOF, THEN OVERLAYING ONE TO SIX INCHES OF SOIL. THERE ARE TWO SYSTEMS OF GREEN ROOF DESIGN: EXTENSIVE AND INTENSIVE. BOTH SYSTEMS INCLUDE RAINWATER CATCHMENTS THAT SEND THE FILTERED RUNOFF INTO BARRELS FOR LANDSCAPE IRRIGATION, EITHER FEEDING BACK TO THE ROOF GARDEN DURING DROUGHTS OR TO SURROUNDING YARDS AND PREVENTING RUNOFF THAT TYPICALLY POLLUTES WATERWAYS AND GROUNDWATER. EXTENSIVE ROOF DESIGN IS THE MOST LIGHTWEIGHT WITH THE LEAST AMOUNT OF SOIL. IT SUPPORTS WATER-RETENTIVE PLANTS SUCH AS SUCCULENTS, WHICH NEED LITTLE MAINTENANCE ONCE ESTABLISHED. INTENSIVE DESIGN USES A DEEPER SOIL LEVEL TO SUPPORT VEGETABLES AND EVEN TREES FOR A GARDEN. - http://drive2.subaru.com/win11/greenrooftops.htm

ATRIUMS OVERVIEW PRECEDENTS SCHEMATIC DESIGN GREEN ROOFS DESPITE THE UP-FRONT COST FROM $5 TO $35 PER SQUARE FOOT GREEN ROOFS PROVIDE MULTIPLE BENEFITS THAT OFFSET THEIR EXPENSE WITHIN A FEW YEARS. THE U.S. ENVIRONMENTAL PROTECTION AGENCY ESTIMATES A FIVE-YEAR AVERAGE TO RECOUP COSTS. COVERING BUILDING TOPS WITH SOIL, SOD, AND GARDENS PROVIDES A PLEASANT PLACE TO SPEND TIME, PARTICULARLY IN URBAN ENVIRONMENTS; PROCESSES CO 2 IN THE ATMOSPHERE; AND PRODUCES OXYGEN, PROVIDES FOOD, AND HELPS INSULATE BUILDINGS SO THEY DON T USE AS MUCH ENERGY TO HEAT OR COOL. THE PLANTS ALSO HELP FILTER THE AIR AS THE BREEZE MOVES THROUGH THEM, PULLING OUT PARTICULATES THAT CAN CAUSE RESPIRATORY ILLNESS. GREEN ROOFS INTERCEPT THE SOLAR RADIATION THAT WOULD STRIKE DARK ROOF SURFACES AND BE CONVERTED INTO HEAT, THEREBY IMPROVING ENERGY CONSERVATION, SAID HITESH MEHTA, A LANDSCAPE ARCHITECT WHO HAS DESIGNED MANY RESORTS AROUND THE WORLD. BECAUSE GREEN ROOFS REDUCE THE SURFACE TEMPERATURE OF A ROOF BY MINIMIZING HEAT- ABSORBING SURFACES, A GREEN ROOF HELPS TO REDUCE ENERGY COSTS INSIDE THE BUILDING AS WELL. LIKE URBAN FORESTS AND REFLECTIVE ROOFING SURFACES, THEY ABSORB AND/OR DEFLECT SOLAR RADIATION SO THAT IT DOES NOT PRODUCE HEAT. THE URBAN HEAT ISLAND EFFECT INCREASES THE USE OF MORE ELECTRICITY FOR AIR CONDITIONERS, AND IT INCREASES THE RATE AT WHICH CHEMICAL PROCESSES GENERATE POLLUTANTS SUCH AS GROUND-LEVEL OZONE. IT ALSO EXACERBATES HEAT-RELATED ILLNESSES. - http://drive2.subaru.com/win11/greenrooftops.htm

TEAM 6 NWARAMBILLI UGBODE EKATERINA SIGAL SERGIO ZAPATA

ATRIUM A central hall or court in a modern building, with rooms or galleries opening off it, often glass-covered

HISTORY An open-roofed entrance hall or central court in an ancient Roman house One particular feature of the early Christian Communities Houses - the atrium, or courtyard with a colonnade surrounding it. atrium

Today the term atrium is associated with commercial or public buildings. The atrium space type includes glazed courtyard spaces and multistoried spaces. Atria are used as key architectural features in main entries, public circulation areas or as special destinations within a building. Atrium design often involves skylights and generous glazing areas that provide an infusion of natural light which make them a prominent building areas well suited to serve ceremonial and social functions. TODAY

Simple Types: FUNDAMENTALS geometry 1. Two sided: Atrium abuts two sides of the occupied portion of the structure. 2. Three sided: Atrium abuts three sides of the occupied portion of the structure. 3. Single sided: Atrium abuts one side of the occupied portion of the structure. 4. Four sided: Atrium abuts four sides of the occupied portion of the structure. 5. Linear: Atrium sandwiched between two occupied portions of structure.

Complex types: 1. Bridging: Atrium connects several occupied portions of structure. FUNDAMENTALS geometry 2. Podium: Atrium sits at the bottom or below an occupied portion of structure. 3. Multiple Lateral: Atrium spaces scattered throughout plan on single or multiple stories. 4. Multiple Vertical: Atrium spaces scattered throughout height of tower structure.

FIRE PROTECTION AND SMOKE Requirements : An engineered smoke control system should be combined with an automatic fire sprinkler system Some form of boundary is required to assist the smoke control system in containing smoke to just the atrium area The Life Safety Code and IBC require that the atrium space be separated from adjacent areas by fire barriers having a fire rating of 1 hour or equivalent The sprinklers are to be located to wet the entire surface of the glass walls Means of escape, emergency egress is a fundamental plan issue and must be integral with the circulation concept of the building Emergency egress must be incorporated from day one Smoke control strategies must be part of the initial ventilation concepts Fire control and fire fighting provisions must be integrated in to the original concepts Sections through atrium

EXAMPLE OF AN ATRIUM AIR FLOW

The key elements that the design engineer should consider in the atrium comfort system design are space temperature, energy efficiency and air system type Space Temperatures- Energy Efficiency- System Type- MAINTENANCE

SKIN OF THE ATRIUM : WALLS ROOFS SLOPING SURFACES * keep water and wind out of the interior space and control the amount and quality of daylight penetrating the space 0penings in the atrium skin should be limited to those required for ventilation and smoke evacuation at the top and bottom and pedestrian access or exit at the bottom Exterior glazing should be of a high performance curtain wall system designed and constructed for the purpose of spanning large distances Glazing in a horizontal application requires protecting atrium occupants from falling glass either by utilizing wired glazing, laminated glazing or providing safety screening below the glazing Sloping skin elements maintain a weather tight seal, accommodate movement in multiple directions and tie into adjacent systems at difficult angles

Students with the most day lighting in their classrooms progressed 20% faster on math tests and 26% faster on reading tests in one year than those with the least day lighting East or west glazing difficult to control glare because direct sun at low angles will be admitted at some point during the day Horizontal glazing at the roof should also be carefully considered because direct light is inevitable from this orientation Diffuse natural light generally is the preferred form of natural lighting The lighting level should be maintained in the range of 15 foot-candles either thru day-lighting or artificial means If indirect schemes are possible, they should be considered If the atrium is used as an egress, the lighting must be capable of immediate restart should normal power be lost Planting and vegetation needs should be addressed. Point source lighting may be necessary. Develop a plan for lamp replacement in high ceilings

Include accessible elevators and ramps in addition to stairways ACCESSIBLE

Highlight or soften the verticality of the space by delineating horizontal bands (such as at floor or ceiling levels) with windows, lighting, wall coverings, and signage. Specify appropriate finishes for open stairways, pedestrian bridges, and other transitional spaces that match finishes in adjacent spaces. Include glazing system materials or detailing that emits natural light, but prevents glare and light reflection.

Design appropriate spaces for the unique requirements of plant species, including attention to lighting, temperature, and air flow. Specify plants with comfort levels similar to occupant comfort levels. Accommodate flexibility and storage of furniture and equipment for ceremonial events and exhibits. Design for maintainability of hard to reach areas, such as re-lamping of high light fixtures and periodic cleaning of dust gathering surfaces. Consider use of portable lifts over scaffolding. Design as an informal meeting space where intellectual/social exchange can take place. Specify durable finishes to accommodate maximum pedestrian traffic.

Specify HVAC equipment that will ensure a comfortable and reliable temperature. For more information see WBDG High- Performance HVAC. If the atrium will be used for performances or ceremonies, study its acoustic properties and include sound absorptive materials as needed. Atria can be used as light courts. Utilize day lighting to reduce energy use through skylights and window walls. Create a vertical "chimney" effect with low intakes and high outlets to facilitate natural ventilation. Provide for smoke control/fire protection engineering requirements In high-risk buildings, such as government or public assembly areas, incorporate blast-resistive design in atria structural system and glazing Design for safety in balconies overlooking atria: Glass railings can become dangerous as breaking/falling objects in terrorism or seismic event Design to prevent/discourage falls and suicide attempts

http://en.wikipedia.org/wiki/atrium_(architecture) http://www.wbdg.org/design/atrium.php http://custo.buildingmedia.com/crs.php?l=180&c=815 http://www.docstoc.com/docs/31455958/atrium-smoke- MANAGEMENT-SYSTEM-DESIGN-Reputation-Resources-Results ASHRAE 1999 Applications, chapter 4.8