V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

Similar documents
VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

Product Line Introduction. Karl Zhang Technical support engineer

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

All DC Inverter Multi VRF

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

DC inverter VRF presentation

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

DC Inverter Smart VRF Products(R410A)

Air Conditioning System

VARIABLE REFRIGERANT FLOW SYSTEMS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Variable Refrigerant Flow (VRF) Multi-Zone Systems

VRV IV i-series heat pump

Air-cooled modular Chiller. Nick Technical Engineer

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Variable Refrigerant Flow

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Ultimate VRF System R410A, 50Hz

Air Conditioning. Air Conditioning. VRF systems

Inverter Ducted Air Conditioners

Air Cooled Scroll Chiller

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner

2017 LINE UP MINI SPLITS CATALOG

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

LG VRF Systems. Air Conditioning Technologies

Part 5. Troubleshooting. 1. Normal Air Conditioner Phenomenon Air Conditioner Protection in Common

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Working With DHPS and Other Variable Capacity Heat Pumps. October 05, 2017

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Variable Refrigeration Flow Systems Overview 10/11/2016

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

3 rd Generation of VRV. The professional solution for your professional project

Business. The business range. The most advanced solutions for larger buildings.

YMGI HVAC Line Card VRF Outdoor Units

HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG. Variable Refrigerant Flow Solutions. TOSOT VRF Catalog 1

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Air conditioning. VRF systems

Advance Split

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

. Creating Maximum Comfort

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

A more comfortable, safe and sustainable world

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

LG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.

Residential and Light Commercial Ductless Systems Catalog

Just feel well. 2017/2018 Air conditioning

Compact design & easy maintenance

Mitsubishi Electric's

Submitted to Reference Approval Construction Unit Designation Schedule #

air systems Roomtop RTC-RTH 15 to 30 - L

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

The Energy Solutions of Withair Full DC Inverter Ducted Split Air conditioning Catalogue 2017 Take Control of Your Energy Future!

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Contents. Introduction. Full DC Inverter VRF 2. Small Capacity Units 5. Advantage 7. Benefits 12. DX-LINE Mini 28. Indoor Units 32

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

Inverter Ducted Air Conditioners

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Product Launch SHRMi

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

Chiller Vs VRF Comparison

Product Brochure Smart Power. Low Profile Ducted

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

NFZP Variable Refrigerant Flow Guide Specification

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Engineering Data Book

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

SUPER FREE MATCH. Smart Zone Controller. It can directly control 16 indoor units in the network without extra communication module.

Inverter Wall Mounted Series

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Submitted to Reference Approval Construction Unit Designation Schedule #

Increase your flexibility.

AHU Plus. DX Air Handling Units

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Service manual. MIV V4+ Mini

R410A VRF Indoor Unit 50Hz AC Series

Engineering Data Book

INVERTER 9-12 DC INVERTER 9 SF

YDS Variable Refrigerant Flow System. Digital Scroll Technology 3rd Generation

PRODUCT LINE-UP Residential & Light Commercial air conditioners

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

PANASONIC INDUSTRIAL VRF SYSTEMS

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

Transcription:

V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer

VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top) 25-90kW V4+W 8-30HP Mini VRF 8-18kW V4+R 8-64HP Largest capacity: 246kW (88HP) per system Heat pump, heat recovery, zone-by-zone mode control

COOL WARM

High efficiency Wide application High reliability Enhanced comfort Heat recovery operation High EER and COP All DC inverter technology Adjustable outdoor HE Energy-saving startup Easy installation Brand-new MS Comparisons

Heat recovery operation More efficient heat recovery operation than individual heating and cooling only Heat pump system 4HP 4HP 2HP 2HP 2HP 2HP Heat recovery system 4HP 2HP 2HP 2HP 2HP

Heat recovery operation A heat recovery system realizes heat transfer between the indoor units and offers high energy efficiency by drawing heat from the rooms to be cooled, and effectively using it as a heat source for the rooms to be heated MS MS MS Heat absorption C H H OFF C OFF H Heat release Heat absorption Heat release Internal transfer

High EER and COP EER up to 4.4 (8HP); COP up to 4.5 (8HP) EER COP 4,6 4,6 4,2 4,2 3,8 3,8 3,4 3,4 3,0 8 10 12 14 16 HP 3,0 8 10 12 14 16 HP

High EER and COP EER is up to 7.0 at 50% cooling and 50% heating EER 7,5 7,0 6,5 6,0 5,5 5,0 4,5 4,0 8HP 10HP 12HP 14HP 16HP 3,5 3,0 100% cooling 75% cooling 25% heating 50% cooling 50% heating 25% cooling 75% heating 100% heating

All DC inverter technology Round 1 DC + fixed compressors DC1 Fix1 Fix2 30Hz ON OFF DC + DC compressors DC1 DC2 50Hz 48Hz Round 2 DC + fixed compressors DC1 Fix1 Fix2 80Hz ON OFF DC + DC compressors DC1 DC2 60Hz 58Hz All DC inverter compressors Capacity output of each compressor is balanced automatically Always work in the 40 to 70 Hertz high-efficiency range

Partitioned outdoor heat exchanger Heat pump VRF Heat recovery VRF Two independent outdoor heat exchanger sections Each heat exchanger section is controlled separately Two independent circuits in a single outdoor unit

Energy-saving startup in heating mode Midea V4+R Competitor 1 Patented design 1 2 3 Patented high pressure balance pipe design enables the four-way valve to switch cooling/heating without starting the slave outdoor units Competitor products need to start all the outdoor units even when the load is lower than a single ODU s capacity

High efficiency Wide application High reliability Enhanced comfort Easy installation Wide outdoor range Wide indoor unit range Wide operation range Long piping length Hydro-box connection Brand-new MS Comparisons

Wide outdoor unit capacity range 8-16 HP 18-32 HP 34-48 HP 50-64 HP

Wide indoor unit range Cassette 1.8-7.1kW 1.8-7.1kW 1.5-4.5kW 1.8-7.1kW Duct Wall-mounted 1.5-14kW 7.1-56kW 2.8-9.0kW 2.8-9.0kW Floor Standing Ceiling & Floor Console Fresh Air Processing Unit 2.2-8.0kW 2.8-9.0kW 2.8-4.5kW 12.5-28kW

Wide indoor unit range Two-way Cassette Four-way Cassette Ceiling & Floor Wall-mounted High ESP Duct For narrow spaces and corners For open spaces, air supply balance For spaces already decorated For small spaces with low-noise requirements ESP up to 196Pa - specially designed for large spaces

Wide operating range -5 C Cooling mode 48 C -5 C Heat recovery mode 24 C -20 C Heating mode 24 C -20 C -15 C -10 C -5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C Cooling mode: -5 C to 48 C Heating mode: -20 C to 24 C Heat recovery mode: -5 C to 24 C

Long piping length Piping length Longest length actual (equivalent) 175m (200m) 70m (110m) 30m 175m (200m) 40m (90m) Longest length after first branch Largest height difference between IDU and ODU ODU up (down) Largest height difference between IDUs 40m (90m) 70m (110m) 30m Total piping 1000m

Connectable to hydro box Hydro-box Under floor heating Hot water: 25 C - 45 C Domestic hot water Mode Switch (MS) box can also be connected to a hydro box to produce hot water Free heating provided by transferring heat from areas requiring cooling to areas requiring heating or hot water

High efficiency Wide application High reliability Enhanced comfort Easy installation Brand-new MS Duty cycling Precise oil control Air-cooled PCB Phase protection Anti-corrosion protection Comparisons

Duty cycling 1 st Cycle 2 nd Cycle 3 rd Cycle 1 2 3 4 5 6 5 6 1 2 3 4 3 4 5 6 1 2 Variable Variable Variable Variable Variable Variable Each module and compressor priority is changed sequentially Equalizes the lifespan of the outdoor units and compressors

Precise oil control technology 2nd stage 4th stage 5th stage 1st stage 3rd stage Five stages of oil control technology Ensures all outdoor compressor oil is always kept at a safe level

Patented air-cooled PCB Patented CN 202792288 U Decreases the average temperature of electrical control components by about 8 C Guarantees the stable and safe running of the control system

Phase sequence protection Power supply terminal on E-box A B C N Power supply terminal on E-box A B C N Normal Incorrect L1 L2 L3 N Power supply 3Phase, 380-415V Voltage (A N): 220V L1 L2 L3 N Power supply 3Phase, 380-415V Voltage (A N): 380V Protection against wrong-phase connections is fitted as standard in the outdoor PCB Protects all the electrical components from damage in the event of accidental wrongphase wiring

Anti-corrosion protection Grill Heat exchanger Fan motor E-box Sheet metal painted parts Screws / bolts / gaskets Anti-corrosion treatment standard on exterior metal parts and heat exchanger Heavy anti-corrosion treatment for extreme conditions available as a customization option

High efficiency Wide application High reliability Enhanced comfort Easy installation Brand-new MS Continuous heating Multi silent mode Auto mode Comparisons

Continuous heating during defrosting Defrosting ODU HE ODU HE HP VRF IDU H H IDU OFF OFF Defrosting ODU L R ODU L R ODU L R HR VRF IDU H H IDU H H IDU H H Either side of the outdoor heat exchanger can operate as a condenser for defrosting while the other side operates as an evaporator to maintain heating output to achieve continuous heating during defrosting

Continuous heating during defrosting Heating capacity curve during defrosting Heating capacity Heat pump VRF Heat recovery VRF Time Heating capacity only drops a little during defrosting Enhances system efficiency and makes the indoor environment more confortable

Multiple silent modes 7:00 14:00 22:00 8:00 Mode Running noise Mode Running noise No silent mode Normal running Super silent mode 12dB(A) lower Silent mode 8dB(A) lower Night silent mode (default) 15dB(A) lower

Auto mode Heating or cooling is automatically selected based on the difference between the room temperature and the temperature setting Keeps the indoor temperature at a constant level

High efficiency Wide application High reliability Enhanced comfort Easy installation Space saving Rotatable control box 360 pipe connection Simple wiring Easy system design Brand-new MS Comparisons

Space saving and economical V4 Plus R (64HP) Competitor (54+10HP) COST Extra Piping Larger footprint Fewer units need to be combined together for a given capacity requirement Saves space and reduces piping requirements

Rotatable control box Patented design Rotatable up to 150 degrees Perform maintenance of the piping system without the need to remove the control box

360 pipe connection Front, rear, right and left orientations are all possible for copper piping, power cables, and communication cables, providing installation flexibility

Simple communication wiring X Y E X Y E PQE PQE H1 H2 E PQE PQE PQE PQE PQE PQE PQE PQE PQE PQE Indoor centralized controller can be connected to either the indoor or the outdoor units Connecting the controller to the outdoor units means that only PQE wiring is required for indoor units (no indoor XYE wiring is required)

Easy system design Windows AutoCAD Two kinds of selection software a Windows version and an AutoCAD version The Windows version is designed to help sales engineers propose configurations and prepare project quotations The AutoCAD version contains engineering drawings and placement guidance

High efficiency Wide application High reliability Enhanced comfort Easy installation Brand-new MS MS lineup Flexible selection Solenoid valve design Sub-cooling technology Operating principle Comparisons

MS lineup Applicable IDUs Appearance Model Max. number of IDU groups Max. number of IDUs in each group Max. total number of IDUs Max. total IDU capacity MS01/N1-C 1 4 4 16kW All IDUs except high static pressure duct MS02/N1-C 2 4 8 28kW MS04/N1-C 4 4 16 45kW MS06/N1-C 6 4 24 45kW Only high static pressure duct MS02E/N1-C 1 1 1 20/25/28kW MS04E/N1-C 1 1 1 40/45/56kW

Flexible selection and installation MS04E MS02E MS04 C H OFF C OFF H H Multiple MS boxes can be used in a system The MS boxes provide the flexibility needed to adapt to the specific requirements of individual projects Pipes in MS boxes can be blocked if not required

Solenoid valve design Compared to 4-way valve switching, running noise is reduced and the risk of leakage is reduced, leading to increased reliability Sub-cooling circuit design for each MS box

Sub-cooling technology 37⁰C High pressure liquid pipe Sub-cooling pipe Low pressure gas pipe MS 22⁰C ODU IDU Enables larger temperature differences to enhance indoor heat-exchange efficiency

Operating principle Cooling Heating High pressure liquid pipe Low pressure gas pipe High pressure gas pipe MS box SVA SVB SVA SV A SV SVB B Indoor unit EXV MS box MS boxes enable heat recovery operation

High efficiency Wide application High reliability Enhanced comfort Easy installation Brand-new MS Comparisons Capacity range Efficiency Piping length MS boxes

Capacity range comparison Capacity 5HP 8HP 10HP 12HP 14HP 16HP 18HP 20HP Midea - - - Brand D Brand M - - Midea has 5 models, up to 4 units can be combined, up to 64HP Brand D has 8 models, up to 3 units can be combined, up to 54HP Brand M has 6 models, up to 2 units can be combined, up to 36HP

Efficiency comparison Efficiency comparison with Brand D EER COP Midea Brand D Midea Brand D 5,0 5,5 4,5 5,0 4,0 4,5 3,5 4,0 3,0 3,5 2,5 3,0

Efficiency comparison Efficiency comparison with Brand M EER COP Midea Brand M Midea Brand M 5,0 5,5 4,5 5,0 4,0 4,5 3,5 4,0 3,0 3,5 2,5 8HP 10HP 12HP 14HP 16HP 18HP 3,0 8HP 10HP 12HP 14HP 16HP 18HP

Refrigerant piping length comparison Midea Brand D Brand M 120 110 100 90 90 80 60 40 70 50 60 40 30 30 60 60 40 40 40 20 15 0 H between IDU & ODU (ODU up) H between IDU & ODU (ODU down) H between IDUs 1st branch to farthest IDU MS to farthest IDU

MS comparison MS lineup comparison Midea Brand D Brand M MS01/N1-C BS1Q(10/16/25)A CMB-P104/5/6/8/10V-G1 MS02(E)/N1-C BS4Q14A CMB-P1013/16V-G1 MS04(E)/N1-C BS6/8Q14A MS06/N1-C BS10/12Q14A BS16Q14A 4 sizes 6 models 5 sizes 9 models 2 sizes 7 models

MS comparison MS comparison with Brand D Brand Midea Brand D Model Max. number of connected IDUs Dimensions WxDxH (mm) Weight (kg) MS01 4 18 630x605x225 MS02 8 19.5 MS04 16 31 960x605x225 MS06 24 35 MS02E 1 630x605x225 19.5 MS04E 1 960x605x225 31 BS1Q10A 5/6 BS1Q16A 8 388x326x207 12 BS1Q25A 8 15 BS4Q14A 20 370x430x298 17 BS6Q14A 30 24 580x430x298 BS8Q14A 40 26 BS10Q14A 50 35 370x430x298 BS12Q14A 60 38 BS16Q14A 64 1060x430x298 50 12

MS comparison MS comparison with Brand M Brand Midea Brand M Model Max. number of connected IDUs Dimensions WxDxH (mm) Weight (kg) MS01 4 18 630x605x225 MS02 8 19.5 MS04 16 31 960x605x225 MS06 24 35 MS02E 1 630x605x225 19.5 MS04E 1 960x605x225 31 CMB-P104V-G1 4 CMB-P105V-G1 5 27 CMB-P106V-G1 6 648x432x284 28 CMB-P108V-G1 8 33 CMB-P1010V-G1 10 38 CMB-P1013V-G1 13 45 1098x432x284 CMB-P1016V-G1 16 52 24

MS comparison MS features comparison Midea Brand D Brand M System 3-pipe heat recovery VRF system 3-pipe heat recovery VRF system 2-pipe heat recovery VRF system Valves Multi solenoid valves control refrigerant flow direction One EXV is used for subcooling All valves are EXVs, some EXVs control refrigerant flow direction Some EXVs are used for sub-cooling 3-way valves and some EXVs control refrigerant flow direction Two EXVs are used for sub-cooling

Quiz What type of compressors does Midea s latest V4+R series VRF use? A. All inverter B. Inverter and fixed speed C. Fixed speed What is the maximum number of indoor units that can be connected to a MS06/N1-C? A. 1 B. 16 C. 24 D. 36

Thank you