XLFE-4/1. Borosilicate glass globe

Similar documents
High bay LED lighting fixture

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

EWL. Supporting bracket

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

GUB. Ex d. Screw-on lid. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66. Polyester coating. Cast mounting feet

Luminex Series ATEX LED lighting

Ex LED light fittings

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Illumination unit For sight glass level indicator Model LGI

Dräger Polytron 5700 IR Detection of flammable gases and vapours

HAZARDOUS AREA SOLUTIONS

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Segnalatori acustici AW-ETH12MD AW-ETH12MD audible warning

DTS Light fittings for explosive atmospheres

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Dräger Polytron 5720 IR Toxic Gas Detection

Segnalatori acustici AW-ETH20MD Audible warning devices

Manual Power relay SR853

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Operating Instructions

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

The value of experience

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Hazardous Area Portable Fan Heater The Bulldog

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

standards: standards:

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

INSTRUCTION & SERVICE MANUAL

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Dräger Polytron 8700 IR Detection of flammable gases and vapors

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

WHO WE ARE AND WHAT WE DO

SOLUZIONI PER ATMOSFERA ESPLOSIVA

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

INSTRUCTION MANUAL (ATEX / IECEx)

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

INTRINSICALLY SAFE LIGHTING RANGE

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Dräger Polytron 5720 IR Detection of carbon dioxide

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

Flameproof Manual Call Points Series MCP

LED Explosion proof Por table light

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Dräger Polytron 8000 Stationary gas detector (EC)

Explosion-proof Immersion Heater Type D-8660

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

Dräger Polytron 8720 IR Detection of carbon dioxide

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

manual addendum DELPHI Ex

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8310 Stationary gas detector (DSIR)

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

Hazardous Area Portable Fan Heater The Bulldog

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Basic Ex products / Zone 1, 21

POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

TYPE APPROVAL CERTIFICATE

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

Hazardous Area Portable Fan Heater The Bulldog

IECEx Certificate of Conformity

Performance Data. curus Component Recognized; File No. E IP 20

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Vigilant LED Based Obstruction Lights

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Transcription:

XLFE-4/1 Borosilicate glass globe - Zone 1, 2, 21, 22 - Obstruction warnings - LOW INTENSITY LED technology - Lamp lifespan more than 10 years - Complies with ICAO, FAA Painted aluminium body Ex e terminal box for fast connection 105 ED.2018

Low intensity XLFE-4/1 LED Obstruction lighting fixtures XLFE-4... /1 series low intensity lighting fixtures are suitable to be installed on towers or high buildings as obstacle signaling devices thanks to the high power and luminous efficiency light source developed by Cortem Group making full use of the experience gained in the world of LED lighting in the recent years. The XLFE-4... /1 lighting fixture, red in color with a luminous intensity of more than 32 candles, complies with the ICAO Annex 14 standard for low intensity aviation warning lamps type A and type B (corresponding to the FAA L-810). The XLFE-4... /1 series is equipped with an internal reflector in chromium-plated anticorodal aluminium alloy and it can be provided with double circuit (main/spare). They are also available for industrial signaling in flashing operation and with different light colors upon request. Application sectors: Oil refineries Chemical Onshore and plants petrochemical plants Offshore plants Oil loading/ unloading jetties Combustible liquid depots High buildings Aircraft storage facilities Hangars CERTIFICATION DATA Classification: Installation: EN 60079.14 Gruppo II Categoria 2GD zona 1 - zona 2 (Gas) zona 21 - zona 22 (Polveri) Marking: Certification: II 2GD Ex de IIC T6 Gb; Ex tb IIIC Db IP66 ATEX CESI 03 ATEX 046 IECEx CES 12.0020 TR CU Standards: Class temperature: Ambient temperature: Degree of protection: ED.2018 All IEC Ex and TR CU certification data can be downloaded at www.cortemgroup.com AVAILABLE CENELEC EN 60079-0: 2009, EN 60079-1: 2007, EN 60079-7: 2007, EN 60079-31: 2009, EN 60598-1:2008+A11:2009, EN60598-2-1:1989 and EUROPEAN DIRECTIVE 2014/34/UE IEC 60079-0: 2011, IEC 60079-1: 2007-04, IEC 60079-31: 2008, IEC 60079-7:2006 European Directive 2006/95 Low voltage European Directive 2004/108 Electromagnetic compatibility European Directive 2003/108 WEEE Waste electrical and electronic equipment European Directive 2011/64 RoHS 100 C (T5) -20 C +55 C Special -50 C +55 C IP66 106

Low intensity XLFE-4/1 LED Obstruction lighting fixtures ORIGINAL PRODUCT MECHANICAL FEATURES Body: Globe: Internal reflector: Gaskets: Heat dissipater: Mounting: Bolts and screws: Entries: Coating: ELECTRICAL FEATURES LEDs: Low copper content aluminium alloy Shock and temperature resistant borosilicate glass sealed with aluminium shade ring In chromed aluminum Silicone acid/hydrocarbon and high temperatures resistant Internally fitted in extruded aluminium See XLFE-4/1 series dimensional drawings Stainless steel 2 ISO M25 entries Epoxy coating Ral 7035 (light grey) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot/humid cycles) and EN60068-2-11 (salt mist tests) 4 x LEDs fitted to electronic plate with single circuit 8 x LEDs fitted to electronic plate with double circuit High resistance to vibration (longer lifespan if installed in severe operating conditions) Estimated lifespan 100,000 hours (12 hours per day for 20 years) Obstruction lighting fixtures Rated voltage Rated frequency Working current Peak current XLFE..024.. 24 Vdc ±10% - 0.145 A 0.45 A XLFE..110.. 110 Vac ±10% 50/60 Hz XLFE..230.. 230 Vac ±10% 50/60 Hz ACCESSORIES AVAILABLE / SPECIAL REQUESTS Special markings in II 2GD Ex d IIC T5 Gb; Ex tb IIIC T.. Db IP66. (sample code: XLF-4V1101/1) Cable gland: NAV25IB for armoured cable or NEV25IB for non-armoured cable Yellow light (XLFE-4G../1), blue light (XLFE-4B../1), green light (XLFE-4V../1) Ex or watertight protected control panel 107 ED.2018

Low intensity XLFE-4/1 LED Obstruction lighting fixtures EXPLODED DIAGRAM OF XLFE-4/1 OBSTRUCTION LIGHTING FIXTURE Aluminium ring with borosilicate glass globe The unit is pre-wired and consists of a light source housing containing the following: LED plate, heat dissipater, electronic power supply unit for the LED modules, support frame, terminal board, chromed aluminum reflector and sealed diaphragm The outside of the lighting fixture body is painted with RAL7035 Ex de protective housings containing the terminal board ICAO, FAA standard. The red XLFE-4/1 unit with light intensity more than 32 candles complies with ICAO Annex 14 Aerodromes vol I. June 2016 (corresponding to the FAA model of code L-810). In compliance with this standard, the luminous flux of the lighting fixture on the horizontal plane is 360 while it is less than 10 on the vertical plane. Single and double A board with a second circuit can be supplied therefore with 4 + 4 LEDs fitted. This innovative system guarantees the correct management with an external panel in the event of a failure in the first circuit thus eliminating the need for costly 2 fixtures applications. For order codes, see the selection chart (not available for flashing lights). ED.2018 Single LED circuit XLFE...1/1 - fixed light and flash - Double LED circuit XLFE...2/1 - fixed light and flash - 108

Dimensional designs low intensity XLFE-4/1 DIMENSIONAL DRAWING Close up of mounting Low intensity XLFE-4...1/1 Close up of mounting Low intensity XLFE-4...2/1 Dimensions in mm 109 ED.2018

Selection chart low intensity XLFE-4/1 Code Colour light Power supply Type of light Type of circuit Weight kg mm XLFE-4R024F1/1 Red 24 Vdc Fixed Individual 3,0 190x170x390 XLFE-4R024F2/1 Red 24 Vdc Fixed Doble 3,0 190x170x390 XLFE-4R024L1/1 Red 24 Vdc Flash Individual 3,0 190x170x390 XLFE-4R110F1/1 Red 110 Vdc Fixed Individual 3,0 190x170x390 XLFE-4R110F2/1 Red 110 Vac Fixed Doble 3,0 190x170x390 XLFE-4R230F1/1 Red 230 Vac Fixed Individual 3,0 190x170x390 XLFE-4R230F2/1 Red 230 Vac Fixed Doble 3,0 190x170x390 XLFE-4R230L1/1 Rossa 230 Vac Flash Individual 3,0 190x170x390 DON T FORGET TO ORDER THE ACCESSORIES Example: Type of lighting fixture + Cable gland + XLFE-4R024F1 NAV25IB other...see key ACCESSORY ED.2018 110

Accessories and spare parts available on request XLFE-4/1 ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY Globe with shade ring XLFE-4..1/1 XLFE-4..2/1 Borosilicate glass globe Threaded aluminium shade ring G50-0440CM G60-0440CM XLFE-4..1/1 OR-4512SH70S O-ring Material: silicone XLFE-4..2/1 K21-131S Ex e type structure mounting 2 x entries ISO M25 G-0439 XLFE-4..024F1 1 circuito, fixed, 24 Vdc EC-32/..024F1 Kit complete with LED plate, heat dissipater, reflector and power supply. For colour LEDs enter the letter: R: red V: green B: blue G: yellow es. EC-48/R024F1 XLFE-4..024F2 2 circuito, fixed, 24 Vdc EC-32/..024F2 XLFE-4..024L1 1 circuito, flash, 24 Vdc EC-32/..024L1 XLFE-4..110F1 1 circuito, fixed, 110 Vac EC-32/..110F1 XLFE-4..110F2 1 circuito, fixed, 110 Vac EC-32/..110F2 XLFE-4..230F1 1 circuito, fixed, 230 Vac EC-32/..110F1 XLFE-4..230F2 1 circuito, fixed, 230 Vac EC-32/..110F2 XLFE-4..230L1 1 circuito, flash, 230 Vac EC-32/..024L1 + 6E24AL6W-F Cable gland For cable gland models and codes see www.cortemgroup.com NAV25IB NEV25IB ACCESSORY 111 ED.2018

Features, installation and mounting methods The double fixtures system requested in the event of an emergency failure, is more expensive due to the installation of 2 applications complete with terminal block and fitting it is also less functional as the beam of light is inevitably covered by the second beam. As can be seen in the diagram below, the luminous flux of the new XLFE-4...2/1 obstruction lighting fixture reaches a full 360 on the horizontal plane with no hindrances thus eliminating the problem of illumination and making installation easier. Obsolete 2 fixture system New XLFE-4...2/1 obstruction lighting fixture 1 beam 2 beam Luminous flux over a 360 Examples of structure fitting. Refer to ICAO and FAA standards for all installation specifications or contact the sales offices ED.2018 112