Revised! see Protective Earthing Addendum P0WER SUPPLY & OUT AUX PWR INPUTS IN O O Relays: O O O O RELAY CONTACTS RELAY CONTACTS RELAYS 1-4 RELAYS 5-8 An 8 way Clocked Relay Controller provides eight single pole Relays with connection terminals to the Common (C), Normally Open (NO), and Normally Closed (NC) contacts. The Relay contacts are rated at 1 Amp @ 0 to 30V DC; reducing to 300mA @ 48V DC. Relay Controllers can be connected together to provide up to 16 relays when connected to a Data Gathering Panel, 64 relays in a Single Lift Controller, or 256 relays when connected to the Challenger Alarm Panel. Mounting: ( See table on page 3 ) TS0816: TS0841 Relay Cards must be mounted in a separate enclosure and are connected with the cable supplied. All 8-32 I/P DGPs: Up to two TS0841 can mount on existing standoffs in all 8-32 Input Data Gathering Panels, depending on what other modules are fitted. TS0015: TS0304: If connected to Version 6 Challenger Alarm Panels, a separate enclosure is required. Separate Enclosure. V6 DGP Box 360 x 260 x 75mm with mounting for 1 Size "A" PCB, and 4 Size "B" PCBs or 2 Size "Double B" PCBs. Note: The TS0841 is a Size "Double B" PCB. Dimensions ( PCB Card ): Size Double B PCB: 176 x 52 mm Current consumption: The Clocked Relay controller requires 50mA standby current and 250mA with all 8 relays active. Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August 1994 1
Wiring: Interconnection between the Relay Controller and the different Challenger equipment is detailed below. Version 8. Challenger Alarm Panel. TS0816 OR Version 8. 8 Input Data Gathering Panel. TS0820, TS0822, TS0823, TS0824 Cable: LEV8-10-500P ( Supplied ) V8 Chall Panel J14 OR V8. 8 I/P DGP J8 1 +12 Volts 1 2 Data 2 4 Latch 4 5 Clk 5 10 0 Volts 10 Version 6 Challenger Alarm Panel. TS0015 OR 8 Input Data Gathering Panel. TS0020, TS0022, TS0023, TS0024 Cable: LEV6-CLK ( Ordered separately ) V6 Chall Panel J8 OR 8 I/P DGP J6 1 Data 7 2 Latch 6 3 Clk 5 6 +12 Volts 2 7 0 Volts 1 Version 5 Challenger Alarm Panel. TS0010 to TS0014, TS05?? Cable: LEV5-CLK ( Ordered separately ) V5 Chall Panel J8 1 Data 3 2 Latch 4 3 Clk 5 6 +12 Volts 10 7 0 Volts 1 16 Input Data Gathering Panel or Access Controller. TS0016, TS0017, TS0067, TS0069 Cable: LEDGP16-CLK ( Ordered separately ) 16 I/P DGP J8 1 Data 6 2 Latch 7 3 Clk 8 6 +12 Volts 10 7 0 Volts 1 Interconnection between two TS0841 Relay Controllers. Cable: LEV8-10-500P ( Supplied ) Relay Controller Out 1 +12 Volts 1 2 Data 2 4 Latch 4 5 Clk 5 10 0 Volts 10 2 TS0841IN.P65: Issue I, Revision I: August 1994
Maximum 8 Way Relay Cards per Challenger product: Maximum Cards. Maximum Usable Relays. Alarm Panels: (All versions) 32 255 DGPs: (All versions) 2 16 Lift Controller: (TS0069) 8 64 Note: Clocked Relay Cards and 4 Way Relay Cards cannot be used together on the same product. Installation Summary: TS0841 CAN CONNECT TO CABLE INSTALLATION TS0816 V8 Alarm Panel. TS0820/TS0822 V8 DGPs. TS0841/TS0842 interconnection. TS0015 Alarm Panel (V6 / V7). TS0020/TS0022 8 I/P DGP. TS0017 16 I/P DGP. TS0067 Door Controller. V5 Challenger Alarm Panels. TS0041/TS0042 Relay / Open Collector Card. Cable supplied Cable supplied Cable supplied LEV6-CLK LEV6-CLK LEDGP16-CLK LEDGP16-CLK LEV5-CLK LECLK-CLK Up to 2 TS0841s can be fitted in TS082? enclosure depending on what other cards fitted. Up to 2 TS0841s can be fitted in TS002? enclosure depending on what other cards fitted. Up to 2 TS0841s can be fitted in V5 enclosure, but extra standoffs required. Cable for interconnecting TS004? Clocked Relay/Open Collector Cards. Power Supply Connections: PWR +12 0V AUX + - Alternative +12 Volt and 0 Volt Power supply connection. This terminal is used when it is necessary to make the Supply connection using heavier guage cable (e.g. figure 8), or from a separate power supply, in order to minimise Voltage drop over longer distances or reduce current drain on the Panel or DGP. If using this power supply connection: - V8 Panel; Remove the "+12V" link near J14. - Other equipment; Ensure that the +12V wire in the "CLK" cable is NOT connected. The AUX + & - terminals are completely separate from the PWR connections and provide the facility to link the Common contacts of the 8 Relays to a positive or negative voltage source (48V DC maximum). Links 1 to 8 allow each of the Common contacts to be linked to Aux + or Aux - as required. Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August 1994 3
Enabling and Programming: Program Relay Assignments. Map relays to Event numbers and/or timezones as required. Relay function can also be inverted or programmed to be active or inactive during thetimezone. See: Challenger Programming Guide for more information. (Installer Menu Option 16) Version 6, 7 & 8 Challenger Alarm Panels. TS0015 & TS0816 Relay Controllers. Enter the number of 8 way Relay Controllers connected to the Challenger Alarm Panel. 8-32 Input Data Gathering Panel. TS0020 to TS0024 & TS0820 to TS0824 Switch DIP switch 6 on Data Gathering Panel to "ON". This enables up to two 8 way Relay Cards. Version 5.9 Challenger Alarm Panel. TS0010 to TS0014, TS05?? Remove Links RL5, RL6 & RL7 on the Alarm Panel PCB. Relays 5, 6, & 7 on the Alarm Panel become inoperative. Installer Menu Option 7 - Program System Options. Output Controllers. Enter the number of 8 way Relay Card Output Controllers connected to the Challenger Alarm Panel. On earlier Version 5 Alarm Panels the Output Controllers option is not enabled by programming. In this case it is necessary to switch DIP switch 6 on the Alarm Panel to "ON". 16 Input Data Gathering Panel. TS0016, TS0017. Switch DIP switch 6 on Data Gathering Panel to "ON". This enables up to two 8 way Relay Cards. 16 Input Access Controller Data Gathering Panel. TS0067, TS0069 Output Controllers. Enter the number of 8 way Relay Controllers connected to the Access Controller. Connection Diagram: PANEL OR DGP TS0841 TS0841 (See tables on p2) CLKOUT IN IN OUT OUT TO OTHER TS0841 RELAY CARDS IF CONNECTED TO CHALLENGER PANEL 4 TS0841IN.P65: Issue I, Revision I: August 1994
N4131 Please note, this product conforms to the standards set by Standards Australia on behalf of the Australian Telecommunications Authority (AUSTEL) and the Spectrum Management Agency (SMA). WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. The Challenger is designed and manufactured by: Interlogix Australia Pty Ltd 646 Whitehorse Rd MITCHAM VIC 3132 A.B.N. 84 086 771 404 PH: 03 9259 4700 FX: 03 9259 4799 C Interlogix Australia 2001 Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August 1994 5