P0WER SUPPLY & OUT AUX PWR INPUTS IN O O O O O O RELAYS 1-4 RELAYS 5-8

Similar documents
Challenger V8 4-Way Relay Card TS0840 TECOM. Installation Guide. Revised! see Protective Earthing Addendum O O O O. Relays: Dimensions ( PCB Card )

Challenger Version 8 Programming Relays.

IEI NETWORK INTERFACE MODEL TS2040

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Power Wave Zone Alarm Panel V8.5. Installation Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Installation, Operating and Maintenance Manual

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

General Routing Interface

MTRA-FSP Level Control Relay. Installation & Operation Manual

MEDI-MINDER USER MANUAL

Fratech Multipath-IP

The EN54 Part 2 & 4 Fire System

FEC400 Series. Installation Manual

TECOM SYSTEMS NETWORK MASTER

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

(Updated Defaults) (Covers Ver: 8.64 and above)

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

EXTINGUISHING AGENT RELEASE MODULE

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Beacon 800 Gas Monitor Operator s Manual

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

KT-100 Door Controller

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

Planning Elevator Relay Groups Programming Millenium for Windows Software

Challenger10 Users Manual

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

INSTALLATION AND PROGRAMMING MANUAL

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd

HRX Technical Manual. Version 1.2

Networked Access Control Panel. Installation Guide

IDP-Zone-6 Six Zone Interface Module

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Model 17A00 Expansion Enclosure

MEDI-MINDER USER MANUAL

Excel-EN Conventional Fire Control Panel

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates.

10yr O2NE & Safe-Ox. User Manual

Operation and Installation Guide. Fire Alarm Control Panel

WM3000 WIRELESS MODULES

AS DIGITAL FIRE PUMP CONTROLLER

Application, Installation, Operation & Maintenance Manual

Interface Modules for SENTRI

MD12-2 Vehicle Loop Detector

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

SMARTWALK DEMENTIA WANDERING SYSTEM

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

AL800ULADA. NAC Power Extender. Installation Guide

LUX Hardwired - Installation Notes

MD12-1 Vehicle Loop Detector

20 Light Remote Annunciator

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Medi-Minder Guardian USER MANUAL

OPERATION AND INSTALLATION MANUAL

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

OPERATION / INSTALLATION

SC-6 Six Supervised Control Module

The Remote alarm Panel, TYPE RAPv2

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

RS Pro Infrared Temperature Sensor

Installation Guide for models:

Challenger Series Users Manual

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

Booster Power Supply Manual

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Alarm Panel Operating Instructions

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

TECHNICAL DATA OBSOLETE

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Brivis Touch Controller. Installer Manual

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Quality Endorsed Company ISO 9001 Lic. No. 5403

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

5000 INSTALLATION GUIDE

AL600ULADA. NAC Power Extender. Installation Guide

Operating Instructions

Heat Sensor Cable Alarm Units DT650L / DT950L

Transcription:

Revised! see Protective Earthing Addendum P0WER SUPPLY & OUT AUX PWR INPUTS IN O O Relays: O O O O RELAY CONTACTS RELAY CONTACTS RELAYS 1-4 RELAYS 5-8 An 8 way Clocked Relay Controller provides eight single pole Relays with connection terminals to the Common (C), Normally Open (NO), and Normally Closed (NC) contacts. The Relay contacts are rated at 1 Amp @ 0 to 30V DC; reducing to 300mA @ 48V DC. Relay Controllers can be connected together to provide up to 16 relays when connected to a Data Gathering Panel, 64 relays in a Single Lift Controller, or 256 relays when connected to the Challenger Alarm Panel. Mounting: ( See table on page 3 ) TS0816: TS0841 Relay Cards must be mounted in a separate enclosure and are connected with the cable supplied. All 8-32 I/P DGPs: Up to two TS0841 can mount on existing standoffs in all 8-32 Input Data Gathering Panels, depending on what other modules are fitted. TS0015: TS0304: If connected to Version 6 Challenger Alarm Panels, a separate enclosure is required. Separate Enclosure. V6 DGP Box 360 x 260 x 75mm with mounting for 1 Size "A" PCB, and 4 Size "B" PCBs or 2 Size "Double B" PCBs. Note: The TS0841 is a Size "Double B" PCB. Dimensions ( PCB Card ): Size Double B PCB: 176 x 52 mm Current consumption: The Clocked Relay controller requires 50mA standby current and 250mA with all 8 relays active. Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August 1994 1

Wiring: Interconnection between the Relay Controller and the different Challenger equipment is detailed below. Version 8. Challenger Alarm Panel. TS0816 OR Version 8. 8 Input Data Gathering Panel. TS0820, TS0822, TS0823, TS0824 Cable: LEV8-10-500P ( Supplied ) V8 Chall Panel J14 OR V8. 8 I/P DGP J8 1 +12 Volts 1 2 Data 2 4 Latch 4 5 Clk 5 10 0 Volts 10 Version 6 Challenger Alarm Panel. TS0015 OR 8 Input Data Gathering Panel. TS0020, TS0022, TS0023, TS0024 Cable: LEV6-CLK ( Ordered separately ) V6 Chall Panel J8 OR 8 I/P DGP J6 1 Data 7 2 Latch 6 3 Clk 5 6 +12 Volts 2 7 0 Volts 1 Version 5 Challenger Alarm Panel. TS0010 to TS0014, TS05?? Cable: LEV5-CLK ( Ordered separately ) V5 Chall Panel J8 1 Data 3 2 Latch 4 3 Clk 5 6 +12 Volts 10 7 0 Volts 1 16 Input Data Gathering Panel or Access Controller. TS0016, TS0017, TS0067, TS0069 Cable: LEDGP16-CLK ( Ordered separately ) 16 I/P DGP J8 1 Data 6 2 Latch 7 3 Clk 8 6 +12 Volts 10 7 0 Volts 1 Interconnection between two TS0841 Relay Controllers. Cable: LEV8-10-500P ( Supplied ) Relay Controller Out 1 +12 Volts 1 2 Data 2 4 Latch 4 5 Clk 5 10 0 Volts 10 2 TS0841IN.P65: Issue I, Revision I: August 1994

Maximum 8 Way Relay Cards per Challenger product: Maximum Cards. Maximum Usable Relays. Alarm Panels: (All versions) 32 255 DGPs: (All versions) 2 16 Lift Controller: (TS0069) 8 64 Note: Clocked Relay Cards and 4 Way Relay Cards cannot be used together on the same product. Installation Summary: TS0841 CAN CONNECT TO CABLE INSTALLATION TS0816 V8 Alarm Panel. TS0820/TS0822 V8 DGPs. TS0841/TS0842 interconnection. TS0015 Alarm Panel (V6 / V7). TS0020/TS0022 8 I/P DGP. TS0017 16 I/P DGP. TS0067 Door Controller. V5 Challenger Alarm Panels. TS0041/TS0042 Relay / Open Collector Card. Cable supplied Cable supplied Cable supplied LEV6-CLK LEV6-CLK LEDGP16-CLK LEDGP16-CLK LEV5-CLK LECLK-CLK Up to 2 TS0841s can be fitted in TS082? enclosure depending on what other cards fitted. Up to 2 TS0841s can be fitted in TS002? enclosure depending on what other cards fitted. Up to 2 TS0841s can be fitted in V5 enclosure, but extra standoffs required. Cable for interconnecting TS004? Clocked Relay/Open Collector Cards. Power Supply Connections: PWR +12 0V AUX + - Alternative +12 Volt and 0 Volt Power supply connection. This terminal is used when it is necessary to make the Supply connection using heavier guage cable (e.g. figure 8), or from a separate power supply, in order to minimise Voltage drop over longer distances or reduce current drain on the Panel or DGP. If using this power supply connection: - V8 Panel; Remove the "+12V" link near J14. - Other equipment; Ensure that the +12V wire in the "CLK" cable is NOT connected. The AUX + & - terminals are completely separate from the PWR connections and provide the facility to link the Common contacts of the 8 Relays to a positive or negative voltage source (48V DC maximum). Links 1 to 8 allow each of the Common contacts to be linked to Aux + or Aux - as required. Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August 1994 3

Enabling and Programming: Program Relay Assignments. Map relays to Event numbers and/or timezones as required. Relay function can also be inverted or programmed to be active or inactive during thetimezone. See: Challenger Programming Guide for more information. (Installer Menu Option 16) Version 6, 7 & 8 Challenger Alarm Panels. TS0015 & TS0816 Relay Controllers. Enter the number of 8 way Relay Controllers connected to the Challenger Alarm Panel. 8-32 Input Data Gathering Panel. TS0020 to TS0024 & TS0820 to TS0824 Switch DIP switch 6 on Data Gathering Panel to "ON". This enables up to two 8 way Relay Cards. Version 5.9 Challenger Alarm Panel. TS0010 to TS0014, TS05?? Remove Links RL5, RL6 & RL7 on the Alarm Panel PCB. Relays 5, 6, & 7 on the Alarm Panel become inoperative. Installer Menu Option 7 - Program System Options. Output Controllers. Enter the number of 8 way Relay Card Output Controllers connected to the Challenger Alarm Panel. On earlier Version 5 Alarm Panels the Output Controllers option is not enabled by programming. In this case it is necessary to switch DIP switch 6 on the Alarm Panel to "ON". 16 Input Data Gathering Panel. TS0016, TS0017. Switch DIP switch 6 on Data Gathering Panel to "ON". This enables up to two 8 way Relay Cards. 16 Input Access Controller Data Gathering Panel. TS0067, TS0069 Output Controllers. Enter the number of 8 way Relay Controllers connected to the Access Controller. Connection Diagram: PANEL OR DGP TS0841 TS0841 (See tables on p2) CLKOUT IN IN OUT OUT TO OTHER TS0841 RELAY CARDS IF CONNECTED TO CHALLENGER PANEL 4 TS0841IN.P65: Issue I, Revision I: August 1994

N4131 Please note, this product conforms to the standards set by Standards Australia on behalf of the Australian Telecommunications Authority (AUSTEL) and the Spectrum Management Agency (SMA). WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. The Challenger is designed and manufactured by: Interlogix Australia Pty Ltd 646 Whitehorse Rd MITCHAM VIC 3132 A.B.N. 84 086 771 404 PH: 03 9259 4700 FX: 03 9259 4799 C Interlogix Australia 2001 Version 8. 8 Way Clocked Relay Card - TS0841: Issue I, Revision I: August 1994 5